Tytuł:
Phenomena leading to asymmetry of phase–to–earth voltages in MV networks
Autorzy:
Lorenc, J.
Staszak, B.
Powiązania:
https://bibliotekanauki.pl/articles/97461.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
earth faults
MV network
voltage asymmetry
earth fault protection
Opis:
When analysing the earth–fault phenomena, the longitudinal impedance of individual elements is neglected, and the capacitances and conductivities of individual phases to ground are only taken into account. Such a procedure is well–founded for resonant earthed networks and the faults accompanied by a significant resistance at the disturbance’s location (called high–resistance faults). However, in such a case, the possibility of occurrence of voltage differences between the network neutral point and the earth should be considered. The voltage is the effect of natural asymmetry in the network’s phase admittances or in the supply voltages. Level of such a voltage asymmetry significantly affects the flawless of the earth–fault protections and the accurate tuning of Petersen coils in the earth–fault compensation process. In the paper, the results of research work on how different phenomena affect the level of the network phase voltage asymmetry are presented. The investigations have been carried out on the PSCAD software–based MV network model, and investigations take into account the relations between asymmetries in the phase capacitance and conductance of the network as well as the load asymmetry degree in the individual power lines.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 158-167
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of High-resistance Earth Faults in Medium Voltage Networks Using Higher Harmonics
Identyfikacja zwarć doziemnych wysokorezystancyjnych w sieciach średnich napięć z wykorzystaniem wyższych harmonicznych
Autorzy:
Marciniak, L.
Piątek, M.
Powiązania:
https://bibliotekanauki.pl/articles/397117.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
high non-linear short-circuit resistance
higher harmonics
earth fault protection
duża nieliniowa rezystancja zwarcia
wyższe harmoniczne
zabezpieczenie ziemnozwarciowe
Opis:
One way to detect line-to-earth arc faults and high-resistance faults in compensated medium voltage networks is based on the criterion of reactive power of higher harmonics in zero sequence voltage and current components. The harmonic content of currents and voltages was evaluated as a function of non-linear short-circuits resistance parameters. This criterion-based earth fault protection’s model is described. Examples of high-resistance fault detection are attached.
Jeden ze sposobów wykrywania zwarć doziemnych łukowych i zwarć wysokorezystancyjnych w kompensowanych sieciach średnich napięć jest oparty na zastosowaniu kryterium mocy biernej wyższych harmonicznych składowych symetrycznych zerowych prądu i napięcia. Oceniono zawartość harmonicznych w prądach i napięciach w funkcji parametrów nieliniowej rezystancji zwarcia. Opisano model zabezpieczenia ziemnozwarciowego z zastosowaniem tego kryterium. Załączono przykłady detekcji zwarć wysokorezystancyjnych.
Źródło:
Acta Energetica; 2017, 1; 50-57
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ground Fault Compensation Effectiveness Conditions in MV Grids with Significant To-Ground Unbalance
Autorzy:
Lorenc, J.
Staszak, B.
Handke, J.
Powiązania:
https://bibliotekanauki.pl/articles/397642.pdf
Data publikacji:
2018
Wydawca:
ENERGA
Tematy:
to-ground unbalance
earth fault compensation
automatic protection systems
asymetria doziemna
kompensacja ziemnozwarciowa
EAZ
Opis:
Operating algorithms of automatic power protection and regulation devices in compensated MV grids often must consider the effect of natural to-ground unbalance. The unbalance degree is determined primarily by the voltage defined by the difference between potentials of the grid’s neutral point and the ground. This voltage has a significant impact on the ground fault protection effectiveness and often limits the possibility of Petersen coils’ fine tuning in the ground fault compensation process. This paper presents results of an analysis of the operating conditions of an MV grid with a significant to-ground unbalance. In the practice of the operation of field grids with a large share of overhead lines, the method based on increasing the ground fault compensation detuning factor is often used. According to the authors, a better solution in this respect is the exact compensation while increasing the attenuation factor. By degrading the coil quality factor, the attenuation factor can be increased by up to four times of its natural value. This solution is also supported by the coil’s arc-suppression efficiency increase.
Źródło:
Acta Energetica; 2018, 4; 81-87
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electric shock hazard in circuits with variable-speed drives
Autorzy:
Czapp, S.
Guzinski, J.
Powiązania:
https://bibliotekanauki.pl/articles/199800.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
variable speed drives
earth fault currents
power electronics converters
protection against electric shock
residual current devices
napędy o zmiennej prędkości
prądy ziemnozwarciowe
zabezpieczenia przed porażeniem elektrycznym
przekształtnik energoelektryczny
Opis:
The conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50‒60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives without inverter output (motor) filter and with one of the two types of inverter output filters being used. The details of both filters are presented, and the effect of harmonics of earth fault current on ventricular fibrillation is evaluated. Furthermore, the effect of harmonics, which occurs in circuit of variable-speed drive, on the tripping current of residual current devices is presented. Residual current devices may be utilized to ensure protection against direct and indirect contact, but limitations in their proper operation, due to harmonics, may exist. Operational characteristics of a proposed residual current device dedicated to circuits with earth fault current containing harmonics, as in the variable-speed circuits, are presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 3; 361-372
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies