Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "discharges" wg kryterium: Temat


Tytuł:
A mobile system for measurements of partial discharges controlled by electroencephalographic waves
Autorzy:
Błachowicz, A.
Paszkiel, Sz.
Powiązania:
https://bibliotekanauki.pl/articles/384381.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
EEG
mobile robot
partial discharges
Opis:
The article presents the concepts of a mobile system for measurements of partial discharges controlled by brain waves. In order to describe that, a robot, which takes measurements of partial discharges, has been worked out. The discharges may occur in an isolator of electrical devices such as capacitors and transformers. What is more, a concept of a link between the robot and a human brain is described, in order to ensure a direct communication on the level of the human brain and the robot.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 3; 31-35
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pilot implementation of the on-line partial discharge monitoring system for heads of the high voltage cable lines
Autorzy:
Konarski, Michał
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/220896.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cable lines diagnostics
partial discharges
unconventional methods of partial discharges measurement
UHF electromagnetic method
Opis:
The article presents the assumptions, characteristics and description of the implementation of a pilot system for on-line monitoring of partial discharges in heads of the high-voltage cable lines. The main purpose of the implementation was to increase the reliability of cable line heads by equipping them with a system of continuous assessment of technical condition with direct transmission of measurement data and alarms to the SCADA system. In order to achieve the assumed goal, unconventional methods for measuring partial discharges were used, the application of which does not require disconnecting the line from the voltage. The implementation was carried out on an active 110 kV high voltage cable line in the area of activity of one of the Distribution System Operators.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 373-382
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ionizing radiation as a component of energy balance in electrical discharges in air and mineral oil
Autorzy:
Nagi, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/114669.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ionizing radiation
electrical discharges
scintillator
energy balance
Opis:
The paper presents the results of research concerning electrical discharges generating ionizing radiation in air and oil. Ionizing radiation is an important component of energy balance in electrical discharges. In energetics and all other engineering sciences, the energy balance shows the flow of energy for a given technological process. Within it, the energy needs of the process and its effect are collated.
Źródło:
Measurement Automation Monitoring; 2016, 62, 4; 146-148
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototyping of UHF antennas using simulation software
Autorzy:
Polak, F.
Sikorski, W.
Siodła, K.
Powiązania:
https://bibliotekanauki.pl/articles/97315.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
partial discharges
UHF antenna
antenna design
simulations
Opis:
The method of ultra high frequency is being increasingly applied in the power transformer diagnostics. Using the probe (antenna) mounted inside the transformer tank it is possible to detect partial discharges occurring in defects of high–voltage insulation system. Such probes must be designed and optimized on several factors, such as frequency band, directivity, or the geometrical design etc. This paper presents parameters of two types of antennas (discone and microstrip patch) obtained through simulation. Calculations and simulations results will provide basis to comnstruct the prototypes of the antennas, which will eventually find application in the measurement system used for localisation of partial discharges inside power transformers.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 168-176
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of a supply voltage value on the UV light generated by PD on HV cap insulators – a comparative analysis
Autorzy:
Urbaniec, I.
Frącz, P.
Powiązania:
https://bibliotekanauki.pl/articles/114117.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
corona discharges
optical emission
HV insulator testing
Opis:
The paper presents results of research works whose aim was to determine and indicate characteristics of optical signals emitted by corona discharges occurring in the vicinity of two types of high-voltage (HV) cap insulators. The experimental studies were performed under laboratory conditions using an ultraviolet (UV) camera. Two types of cap insulators were analyzed: one made of glass and the second one made of porcelain. For both considered insulating devices, the influence of supply voltage on the intensity of optical radiation was determined. The obtained results were analyzed and compared. Based on the results, it was stated that both cap insulators indicated similar characteristics but the most significant difference lied in the existence of the punch-through on the glass cap.
Źródło:
Measurement Automation Monitoring; 2015, 61, 10; 470-474
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of Partial Discharges in Cable Insulation and Cable Head Using Acoustic Method
Autorzy:
Ranachowski, Zbigniew
Wieczorek, Krzysztof
Ranachowski, Przemysław
Dębowski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2141672.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
medium voltage insulation
acoustic emission
Opis:
The article presents the application of Acoustic Emission (AE) method for detection and registration of partial discharges (PD) generated in medium voltage (MV) cable isolation and MV cable head. The insulation of the high voltage cable is made of a flexible material whose properties are characterised by a high coefficient of attenuation of the acoustic signals. For this reason, the AE method has not been used so far to detect PD in energetic cables. The subjects of the research were the MV cable and the standard T-type cable head. The cable contained defects which were the source of partial discharges. In case of cable head the PD were provoked by thin grounded electrode which was introduced into connector opening. The results of AE measurements are presented in the form of spectrograms. Acoustic Emission was evoked when the applied voltage level reached the value of 7.5 kV for the cable and 4 kV for the cable head. The authors used the acoustic instrumentation of their own design intended for future field use. Obtaining successful results of partial discharges measurements using the acoustic method in the cable insulation makes an original contribution of the presented work.
Źródło:
Archives of Acoustics; 2022, 47, 2; 259-265
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The combined approach to solving issues of the flood hazard assessment using water gauge records and spatial data
Lączone podejście do rozwiązywania zagadnień oceny zagrożeń powodziowych z wykorzystaniem danych wodowskazowych i danych przestrzennych
Autorzy:
Korbutiak, V.
Stefanyshyn, D.
Lahodniuk, O.
Lahodniuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/2083854.pdf
Data publikacji:
2020
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
water discharges
channel transformations
anthropogenic impact
hydrological data
Opis:
The research deals with the combined approach to boost the reliability of hydrological estimates based on a series of observations being supported by spatial data. In particular, the application of various theoretical curves of probability distribution or situations that may occur at submountain sections of rivers (for example, alluvium accumulation or river bed erosion) is considered. Because of the obsolete cadastral data on the riverbeds and catchments, the necessity of the use of remote sensing is substantiated. Assessment of the dynamics of changes in the river cross-section profiles allows making conclusions concerning the direction of the channel deformations – deepening and straitening the river channels or increasing their cross dimensions. This information may complement the assessment of flood protection of the territories.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2020, 19, 1; 111-118
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of diaphragms on measurements of ions emitted from dense magnetized plasmas
Autorzy:
Skladnik-Sadowska, E.
Sadowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/146562.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
diagnostic of ions
energy distribution
plasma discharges
separate ions
Opis:
The paper concerns the diagnostics of ions escaping from dense magnetized plasma (DMP) discharges. Particular attention is paid to the basic problem of the separation of such ions from the investigated plasma, under the condition that this process should not disturb the velocity (and energy) distribution functions of the measured ions.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 57-60
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Clustering Methods for the Identification of Acoustic Emission Signals Generated by the Selected Form of Partial Discharge in Oil-Paper Insulation
Autorzy:
Borucki, S.
Łuczak, J.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/177657.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
insulation
power transformer
Opis:
The article presents the results concerning the use of clustering methods to identify signals of acoustic emission (AE) generated by partial discharge (PD) in oil-paper insulation. The conducted testing featured qualitative analysis of the following clustering methods: single linkage, complete linkage, average linkage, centroid linkage and Ward linkage. The purpose of the analysis was to search the tested series of AE signal measurements, deriving from three various PD forms, for elements of grouping (clusters), which are most similar to one another and maximally different than in other groups in terms of a specific feature or adopted criteria. Then, the conducted clustering was used as a basis for attempting to assess the effectiveness of identification of particular PD forms that modelled exemplary defects of the power transformer’s oil-paper insulation system. The relevant analyses and simulations were conducted using the Matlab estimation environment and the clustering procedures available in it. The conducted tests featured analyses of the results of the series of measurements of acoustic emissions generated by the basic PD forms, which were obtained in laboratory conditions using spark gap systems that modelled the defects of the power transformer’s oil-paper insulation.
Źródło:
Archives of Acoustics; 2018, 43, 2; 207-215
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time and frequency domain analysis of partial discharges using electrical method
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/973070.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
partial discharges
electrical method
IEC 60270
frequency domain
time domain
Opis:
Partial discharge (PD) measurement results with particular consideration of time domain and frequency domain analysis of pulses generated by PD model sources are presented in the paper. Three different PD generation model sources are selected for the research: surface type, point to point and multi-point to plate. All measurements are proceeded under laboratory conditions using electrical method of a PD detection, according to the IEC60270 standard. Various amplitude and power density spectrum descriptors are proposed, as well as PD source type identification abilities on grounds of the selected descriptors are considerated. Electrical power transformers on-line PD detection and evaluation systems improvement and development are the main purpose of the presented research. Laboratory experiment results gives a solid base for further research focused on verification of the proposed methodology on a real life apparatus.
Źródło:
Measurement Automation Monitoring; 2016, 62, 2; 72-77
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High voltage harmonics induced modifications of PD phase-resolved patterns
Autorzy:
Florkowski, M.
Florkowska, B.
Zydroń, P.
Powiązania:
https://bibliotekanauki.pl/articles/141372.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical insulation system
diagnostics
harmonics
partial discharges
phase-resolved patterns
Opis:
Partial discharges (PD) are influencing electrical insulating systems of high voltage electrical devices. Typically, in laboratory and diagnostics AC tests focused on measuring and analysis of PD, a pure sinusoidal voltage waveform is assumed. However, in practice the spectral content of the working voltage is rarely so ideal and additional spectral components have a significant impact on the discharge behaviour in electrical insulation systems. In this paper the influence of voltage harmonics on PD behaviour and phase-resolved PD patterns evolution is analysed. The presented experiments were conducted on a specimen representing a gaseous inclusion embedded in electrical insulation. The experimental results showed that various harmonic compositions superimposed on the fundamental sinusoidal waveform have a significant impact on PD intensity and maximum charge. In consequence, the derived patterns of PD phase, and magnitude distributions are distorted, and statistical parameters calculated on their basis are changed. In certain environments, neglecting harmonic content in the testing voltage may lead to a misleading interpretation and assessment of PD severity.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 231--246
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of UV camera for PD detection on long rod HV insulator
Autorzy:
Urbaniec, I.
Frącz, P.
Powiązania:
https://bibliotekanauki.pl/articles/114242.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
surface partial discharges
PD measurements
optical method
HV insulator diagnosis
Opis:
The aim of the research works, results of which are presented in this paper, was to determine the feasibility and to indicate the application scope of optical method in the diagnosis of high-voltage (HV) long rod insulators. Diagnosis of technical condition of HV insulators is critical, because the insulation system undergoes aging processes, which cause deterioration of the insulating properties. The measurements were performed during test under laboratory conditions using an UV camera. Corona partial discharges occurring on the long rod insulator were registered, while the supply voltage value was increased. The presented analyses consider dependencies of the supply voltage value on the count number of UV photons emitted by partial discharges occurring in long rod insulator made of porcelain.
Źródło:
Measurement Automation Monitoring; 2015, 61, 3; 64-67
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafast X-ray introspective imaging of metallic objects using a Plasma Focus
Autorzy:
Moreno, C. H.
Clausse, A.
Martínez, J. F.
Llovera, R.
Tartaglione, A.
Powiązania:
https://bibliotekanauki.pl/articles/146595.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasmas
electrical discharges
plasma focus
X-ray imaging
X-rays
Opis:
A compact-chamber 4.7 kJ, 30 kV, Plasma Focus operated in deuterium was used as a ultrafast high intensity radiation source for introspective radiographic imaging of metallic objects. The samples to be imaged were located outside the Plasma Focus chamber, about 1 m away from the chamber wall. A high-sensitivity, fast-response commercial radiographic film was used as a X-ray detector. Experimentally obtained images are presented showing a very high penetration power of the X-ray beam, demonstrating that the presented compact-chamber Plasma Focus is suited for introspective visualisation of pieces manufactured on metal.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 33-34
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method to determine solar-blind ultraviolet energy and electrical corona loss relation
Autorzy:
Coetzer, Casper J.
Myburgh, Hermanus C.
West, Nicolas
Walker, Jerry
Powiązania:
https://bibliotekanauki.pl/articles/2174850.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
AC voltage
algorithm corona cameras
electrical discharges
optical energy
radiometric measurements
Opis:
Solar-blind ultraviolet cameras as part of high-voltage electrical inspections until recently have mostly been used for pure observations. These observations only imply the presence of corona discharges and not the severity thereof. A radiometric algorithm together with a calibration algorithm to perform an optical energy measurement were presented earlier. This is a guide on how to apply the algorithm to determine the total optical measurement from corona discharges, plus additional processing. This guide and additions are used to compare the electrical and optical domains with actual examples. The main objective is to illustrate how to determine the electrical and optical relation for the IEC 60720 high-voltage electrical test configurations using a standard open procedure.
Źródło:
Opto-Electronics Review; 2022, 30, 4; art. no. e143433
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors
Autorzy:
Mišák, S.
Hamacek, Š.
Bartłomiejczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/221694.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault trees
partial discharges
fault diagnosis
power engineering
power overhead lines
Opis:
This paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the above mentioned faults was developed. After having tested its operation, the system has already been implemented to protect mediumvoltage overhead lines built of covered conductors.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 277-288
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies