Tytuł:
Magnetizing current effect minimization in current transformers
Autorzy:
Dusza, D.
Rzepecki, B.
Powiązania:
https://bibliotekanauki.pl/articles/1813967.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current transformer
value converter
ratio
error minimization
magnetizing current effect
current transformer's error
current measurement
Opis:
Magnetizing current effect minimization in current transformers is considered in this paper. Double-core current transformer operation is described in the following text. The influence of the magnetizing current, which is a significant element of current transformer's error, has been minimized in a new type of double-core current transformer connection. The accuracy evaluation of built double-core current transformer has been carried out according to obtained transformation precision.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2013, 69, 33; 469--476
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differential protection with better stabilization for external faults
Zabezpieczenie różnicowe z lepszą stabilizacją dla zwarć zewnętrznych
Autorzy:
Solak, K.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410581.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current differential criterion
current transformer
fuzzy logic
saturation
Opis:
This paper presents a new differential protection scheme for transmission lines with application of fuzzy signal processing and support of phase comparison criterion. Traditional differential relays may have problems with proper classification of external faults with CT saturation. Better protection stabilization for such cases is obtained with support of fuzzy signal processing. In proposed solution the input signals as well as the standard percentage characteristic are fuzzified. The performance of presented fuzzy protection scheme has been tested with the signals generated with use of EMTP-ATP program and compared to the traditional solution.
W artykule zaprezentowano nowe zabezpieczenie różnicowe, w którym zastosowano rozmyte przetwarzanie sygnałów oraz dodatkowe kryterium porównawczo-fazowe. Proponowane zabezpieczenie jest bardziej odporne na zwarcia zewnętrzne z nasyceniem przekładników prądowych, co potwierdziły przeprowadzone testy. Proponowany algorytm testowany był na sygnałach pochodzących z symulacji w EMTP-ATP, a wyniki porównano ze standardowym przekaźnikiem różnicowym.
Źródło:
Present Problems of Power System Control; 2011, 1; 39-48
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototype of an Integrating Current Transformer for Beam Intensity Measurements in the Large Hadron Collider
Autorzy:
Krupa, M
Napieralski, A
Powiązania:
https://bibliotekanauki.pl/articles/398102.pdf
Data publikacji:
2013
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
diagnostyka wiązki
pomiar natężenia wiązki
transformator
ICT
FBCT
beam diagnostics
beam intensity measurements
Integrating Current Transformer
Fast Beam Current Transformer
Opis:
The beam intensity (number of particles forming the beam) in the Large Hadron Collider (LHC) is measured by eight current transformers. The average beam current is monitored by the four DC Current Transformers (DCCTs) and the range from a few hundred hertz to over a gigahertz is covered by the four Fast Beam Current Transformers (FBCTs). During the early run of the LHC the beam intensity measured by the FBCTs was observed to be correlated to the beam position and charge distribution. To address the consequential limitations a prototype of an Integrating Current Transformer (ICT) has been developed at CERN as a possible future replacement of the FBCTs. In this article, its design, principle of operation along with results of first beam tests are presented. The measured beam-position-dependency of the ICT has been improved, compared to the FBCT, by a factor of 35 and 50 in the vertical and horizontal planes, respectively.
Źródło:
International Journal of Microelectronics and Computer Science; 2013, 4, 1; 32-36
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of the inductive current transformer derating for operation with distorted currents
Autorzy:
Kaczmarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/201060.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer
distorted current
derating conditions
composite errors
transformer correction factor
accuracy class
Opis:
The aim of the paper is to present a new method for estimation of the CT (Current Transformer) rated primary current and / or load of the secondary winding derating levels for transformation of distorted current in relation to the rated values fixed for transformation of sinusoidal current. This ensures the values of the CT composite errors/transformer correction factors as resulting from its IEC 60044-1/IEEE C57.13 accuracy class in condition of distorted currents transformation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 2; 363-366
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A complex current ratio device for the calibration of current transformer test sets.
Autorzy:
Çayci, H.
Powiązania:
https://bibliotekanauki.pl/articles/221001.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer test set
ratio error
phase displacement
current comparator
compensation
Opis:
A practical method with high accuracy in generation and application of error values for calibration of current transformer test sets is described. A PC-controlled three-phase power source with a standard wattmeter is used for generating the nominal and error test currents while an electronically compensated current comparator is used to provide summation and subtraction of them, precisely. With this method, any ratio error and phase displacement values could be generated automatically and nominal and test currents could be grounded on the test set safely. Because of its high accurate ratio and phase error generating capability, any type of test set regardless of its operating principles could be calibrated.
Źródło:
Metrology and Measurement Systems; 2011, 18, 1; 159-164
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Universal Current Transformer for Accurate Measurement of Short-circuit Currents
Uniwersalny przekładnik prądowy do dokładnego pomiaru prądów zwarciowych
Autorzy:
Przybysz, J.
Olak, J.
Piątek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397436.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
current transformer
aperiodic time constant
short circuit tests
przekładnik prądowy
aperiodyczna stała czasowa
badania zwarciowe
Opis:
The paper presents the design of a special current transformer developed by the Institute of Power Engineering in cooperation with TRANSFORMEX sp. z o.o. The aim of the project was to obtain current transformers allowing not only a thorough transformation of symmetrical currents – which is characteristic for typical current transformers, but also of asymmetrical shortcircuit currents containing an aperiodic component, which are not reproduced by classic current transformers. A current transformer has been developed with a range of short-circuit currents established from 1 kA to 50 kA, and short-circuit currents with an aperiodic component with a decay time constant up to 200 ms, peak value from 2.5 kA to 125 kA, assuming the possibility of five-fold repetition of short circuits with the same value and the same constant component polarity, with the assumed transformation accuracy.
W artykule przedstawiono konstrukcję specjalnego przekładnika prądowego opracowanego we współpracy Instytutu Energetyki z firmą TRANSFORMEX sp. z o.o. Celem pracy było uzyskanie przekładników prądowych umożliwiających nie tylko dokładną transformację prądów przemiennych ustalonych – co jest znamienne dla typowych przekładników prądowych, ale również niesymetrycznych prądów zwarciowych zawierających składową bezokresową, których klasyczne przekładniki prądowe nie odtwarzają. Opracowano przekładnik prądowy o zakresie prądów zwarciowych ustalonych od 1 kA do 50 kA oraz prądów zwarciowych ze składową bezokresową o stałej czasowej zanikania do 200 ms, o wartości szczytowej od 2,5 kA do 125 kA, przy przyjęciu możliwości pięciokrotnego powtarzania zwarć tej samej wartości i tej samej biegunowości składowej stałej, przy założonej dokładności transformacji.
Źródło:
Acta Energetica; 2017, 1; 101-106
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using G.652 telecommunication single-mode optical fiber for a measurement coil of the interferometric current sensor
Zastosowanie jednomodowego światłowodu telekomunikacyjnego g.652 do realizacji cewki pomiarowej w interferometrycznym czujniku natężenia prądu
Autorzy:
Torbus, S. A.
Powiązania:
https://bibliotekanauki.pl/articles/194116.pdf
Data publikacji:
2010
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
stała Verdeta
zjawisko magnetooptyczne Faradaya
interferometryczny czujnik natężenia prądu
światłowodowy przekładnik prądowy
światłowód jednomodowy
światłowód wielomodowy
Verdet constant
mangeto-optical phenomenon
interferometric current sensor
optical fiber current transformer
single-mode optical fiber
multi-mode optical fiber
Opis:
This article describes benefits of using a G.652 telecommunication optical fibre instead of a multi-mode optical fibre for a measurement coil of the interferometric current sensor. The simulation results were presented for coils with various numbers of turns and made of various optical fibres - a single-mode and multi-mode fibre.
W artykule pokazano, że preferowane jest stosowanie standardowego światłowodu telekomunikacyjnego G.652 do wykonania cewki pomiarowej interferometrycznego czujnika natężenia prądu, zamiast światłowodu wielomodowego. Przedstawiono wyniki symulacji dla cewek o różnej liczbie zwojów i różnych wartości natężenia prądu dla dwóch różnych typów włókien światłowodowych - jednomodowego i wielomodowego.
Źródło:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy; 2010, 15; 67-74
0209-0570
Pojawia się w:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Numerical Model of 2G YBCO Superconducting Tape in the Windings of the Transformer
Autorzy:
Woźniak, Ł.
Surdacki, P.
Jaroszyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/117874.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
YBCO 2G tape
superconducting transformer
current limitation
Opis:
Computer assisted calculations consists in applying software for the simu-lation of models of certain devices and later analysing their behavior under given conditions corresponding to real working conditions in a specific environment.The paper proposes a circuit model of 2G YBCO super-conducting tape created in the PSpice program. The model consists of passive blocks and active user blocks of analogue behavioural modelling (ABM). ABM blocks calculate the conductances, the currents of the indi-vidual layers of the superconducting tape, its thermal capacity, the heating power, the cooling power and resulting temperature of the tape. The model uses table of thermal power density passed to the liquid nitrogen vs. temperature. Smooth transition of the YBCO superconductor layer into the resistive state is described by Rhyner’s power law. The developed model was used for generating waveforms of thermal and electrical quantities.
Źródło:
Applied Computer Science; 2017, 13, 2; 23-38
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long lasting transients in power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97714.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
inrush current
arc fumace transformer
harmonic filter
switching transient
Opis:
The practice of operating AC electrical arc fumace power supply systems has shown that energizing unloaded fumace transformer can cause long lasting transients in filter circuits of static VAR compensators used in the supply systems. Examination of the supply system configuration impact on switching transient behaviour has been carried out by example of a 50 MVA arc fumace unit. The transient analysis has been carried out through simulating by Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 324-333
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computation of electromagnetic forces in the windings of amorphous core transformers
Autorzy:
Thanh, Bao Doan
Tung, Doan Duc
Le, Tuan-Ho
Powiązania:
https://bibliotekanauki.pl/articles/24202732.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
amorphous transformer
electromagnetic force
leakage flux
magnetic vector potential formulation
short-circuit current
Opis:
Electromagnetic forces generated by the short circuit current and leakage flux in low- and high-voltage windings of distribution transformers as well as amorphous core transformers will cause the translation, destruction, and explosion of the windings. Thus, the investigation of these forces plays a significant role for researchers and manufacturers. Many authors have recently used the finite element method to analyze electromagnetic forces. In this paper, an analytic model is first developed for magnetic vector potential formulations to compute the electromagnetic forces (i.e., axial and radial forces) acting on the low- and high-voltage windings of an amorphous core transformer. The finite element technique is then presented to validate the results obtained from the analytical model. The developed model is applied to an actual problem.
Źródło:
Archives of Electrical Engineering; 2023, 72, 2; 521--539
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study on the Low Frequency Transients in Power Transformers and Some Protection-Related Issues
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/1203944.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
transformer cores
inrush current
protection
transients
modeling
equivalent circuit
low frequency
nonlinear model
simulation
Opis:
This paper presents typical results for the non-linear low frequency transients following the energization of power transformers. The three operating conditions of no-load, full-load and internal faults are considered. A direct analytical procedure is applied for solving the corresponding set of differential equations describing the transformers equivalent circuit. The core representation is based on the use of curve fitting applied to their magnetization curves. The results include plots versus time for the supply current, the core flux, the magnetizing current as well as the internal induced voltage. Moreover, graphs for the hysteresis loops relating the instantaneous values of both the excitation current and the core flux are given. An approach is also presented for the numerical determination of the amplitudes of the different harmonics existing in any of these signals utilizing the corresponding equidistant samples. As examples, the DC offset as well as harmonics up to the fourth order are considered. It is shown that several useful features can be extracted from the results in both the time and harmonic domains that can assist in differentiating between overcurrents resulting from short-circuits or inrush phenomena.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2014, 17, 2; 9-16
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element analysis of eddy current losses in pulse transformer
Analiza strat wiroprądowych w transformatorze impulsowym metodą elementów skończonych
Autorzy:
Łyskawiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/159946.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
transformator impulsowy
straty wiroprądowe mocy
metoda elementów skończonych
pulse transformer
eddy current losses
FEM analysis
Opis:
In the paper an algorithm for power loss determination in pulse transformers using a field-circuit model is described. The software based on the algorithm is used to calculate eddy current losses and determine efficiency of a pulse transformer. Eddy current power losses and efficiency of a pulse transformer for different load resistances, input signal shapes and lengths of the central leg of the core are analysed. Selected results of simulations are shown.
Wiroprądowe straty mocy ΔP w transformatorze impulsowym można wyznaczyć na podstawie czasowego przebiegu oraz przestrzennego rozkładu wektora gęstości prądu z zależności (1). Obliczanie tych strat jest jednak zagadnieniem trudnym, ponieważ w ogólnym przypadku przy wymuszeniu napięciowym w układach zawierających elementy nieliniowe nie jest znany a priori przebieg i rozkład gęstość prądu w uzwojeniach i prądów wirowych w rdzeniu. W celu wyznaczenia tych prądów posłużono się modelem polowo-obwodowym transformatora impulsowego. Model ten obejmuje równania pola elektromagnetycznego (3) i równania opisujące rozpływ prądów w obwodach elektrycznych (2). Ze względu na nieliniowość, szybką zmienność pola w czasie oraz złożoną strukturę równań tych nie można rozwiązać analitycznie. W tym celu wykorzystuje metodę elementów skończonych, polegającą na dyskretyzacji przestrzeni i czasu. W wyniku uzyskuje się układ nieliniowych równań algebraicznych (4). Do rozwiązania tego układu równań wykorzystuje się iteracyjną metodę Newtona-Raphsona. Na podstawie obliczonych rozkładów gęstości prądów z zależności (1) wyznacza się wiroprądowe straty mocy w rdzeniu i straty mocy w uzwojeniach. Na podstawie przedstawionego algorytmu opracowano program do wyznaczania wiroprądowych strat mocy i sprawności w transformatorze impulsowym. Rozpatrzono transformator o mocy 240 W z rdzeniem ETD 44 wykonanym z ferrytu N 67 o strukturze przedstawionej na rys. 1. W rozważaniach uwzględniono nieliniowe właściwości materiałów magnetycznych oraz prądy wirowe indukujące się w rdzeniu i uzwojeniach. Transformator obciążono rezystancją Ro. Dla Ro = Rn uzyskano znamionowy prąd obciążenia. Ze względu na szeroki zakres zmian względnej rezystancji obciążenia r = Ro/Rn na zamieszczonych w artykule wykresach posłużono się skalą logarytmiczną. Badano wpływ zmian względnej rezystancji obciążenia r i kształtu sygnału zasilającego na względne straty mocy w uzwojeniach pu = ΔPu /ΔPun (rys. 2) i w rdzeniu pr = ΔPr /ΔPrn (rys. 3) oraz sprawność η transformatora (rys. 6). Przy obliczaniu sprawności uwzględniono straty histerezowe wyznaczone w sposób przybliżony na podstawie danych katalogowych. Sprawność tą porównano w pewnym zakresie obciążeń ze sprawności transformatora pracującego w zasilaczu impulsowym (rys. 4). Opracowane oprogramowanie umożliwia analizę wiroprądowych strat mocy w uzwojeniach i rdzeniu transformatorów impulsowych. Zatem może być przydatne w projektowaniu i optymalizacji rozpatrywanych transformatorów.
Źródło:
Prace Instytutu Elektrotechniki; 2006, 229; 75-85
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A dual inductor-fed boost converter with an auxiliary transformer and voltage doubler
Autorzy:
Dawidziuk, J.
Powiązania:
https://bibliotekanauki.pl/articles/201526.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC/DC boost converter
current-fed
dual inductor-fed
auxiliary transformer
voltage doubler
photovoltaic systems
Opis:
This paper presents a dual inductor-fed boost converter with an auxiliary transformer and voltage doubler for sustainable energy power converters. The new topology integrates a two-phase boost converter and a dual inductor-fed boost converter. The energy stored and transferred by both inductors can attain a wide input-voltage and load range which uses a constant switching frequency, by controlling the time duration of the simultaneous conduction of the two switches. Among other current-fed type boost converters the presented topology is attractive due to the high voltage conversion ratio, less stress on the components and less switch conduction loss. To verify the feasibility of this topology, the principles of operation, theoretical analysis, and experimental waveforms are presented for a 1 kW prototype.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 787-791
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The new concept of the 2G HTS superconducting transformer
Nowa koncepcja transformatorów nadprzewodnikowych z taśm HTS 2G
Autorzy:
Wojtasiewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/159138.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
superconducting transformer
2G HTS tape
transformer windings
parallel tapes
current distribution
power losser
transformator nadprzewodnikowy
taśma HTS 2G
uzwojenia transformatorów
taśmy równoległe
Opis:
The new 2G HTS tapes with high critical current and high resistivity in the normal state allow to build low-cost transformers with high short-circuit strength for the low and medium power distribution substations. The authors consider that currently the best chance of building have transformers, which rated currents of their windings do not exceed or slightly exceed the critical current of used superconducting tapes. Such units could be the low or medium voltage transformers with power less than 10 MVA, where the high voltage winding can be made with single HTS tape while the low voltage winding can also be made of single HTS tape or two – three tapes connected in parallel. This eliminates the need of tape transposition or application of the Roebel’s cable. Superconducting transformers could stabilize the low or medium power network and increase the connectivity of renewable and dispersed energy sources. The article presents an analysis of the possibility of using the low and medium voltage superconducting transformers. Such units could be e.g transformers working with renewable energy sources.
Nowe taśmy nadprzewodnikowe 2G HTS o wysokim prądzie krytycznym i wysokiej rezystywności w stanie rezystywnym pozwalają na budowę transformatorów o wysokiej odporności na zwarcia dla sieci dystrybucyjnych niskich i średnich energii. Obecnie największe szanse na budowę mają transformatory, których znamionowe prądy uzwojeń nie przekraczają lub nieco przekraczają wartości prądu krytycznego zastosowanych taśm nadprzewodnikowych. Takimi jednostkami mogą być transformatory niskiego lub średniego napięcia o mocy poniżej 10 MVA, gdzie uzwojenie wysokonapięciowe może być wykonane pojedynczą taśmą HTS, a uzwojenie niskonapięciowe może być również wykonane z pojedynczej taśmy HTS lub dwóch - trzech taśm połączonych równolegle. Eliminuje to konieczność transpozycji taśm a tym samym zastosowania kabla Roebel. Zastosowanie transformatorów nadprzewodnikowych mogłoby ustabilizować sieć energetyczną niskiego i średniego napięcia i zwiększyć zdolność łączeniową odnawialnych i rozproszonych źródeł energii.
Źródło:
Prace Instytutu Elektrotechniki; 2017, 277; 43-54
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of higher harmonics generation by non-linear loads
Analiza wytwarzania wyzszych harmonicznych przez odbiorniki nieliniowe
Autorzy:
Necka, K.
Powiązania:
https://bibliotekanauki.pl/articles/793595.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
nonlinear load
distortion factor
higher harmonics
oscillogram
low-voltage grid
transformer station
supply voltage
supply current
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-15 z 15

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies