Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "chłodnia" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Strength analysis of insulated body with the use of FEM
Badania wytrzymałościowe MES konstrukcji naczepy chłodni
Autorzy:
Marcinkiewicz, J.
Bieńczak, A.
Dembicki, D.
Dudziński, P.
Mac, J.
Szczepaniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/334878.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
modeling
trailer
insulated body
FEM analysis
loads
modelowanie
naczepa
chłodnia
analiza MES
obciążenie
Opis:
The paper presents the results of the computer analysis of strength of insulated body. Mathematical model was described. The analysis included the development of load characteristics based on exploitation conditions. Based on construction data computational models of the analyzed construction were developed. Their simulation tests and result analysis carried information about stress distribution in the semi-trailer construction. In particular, actions were focused on presenting the load implementation of trailer during driving on a bend of the road.
W pracy przedstawiono wyniki komputerowych analiz wytrzymałościowych konstrukcji naczepy chłodni. Opisano model matematyczny zestawu transportowego. Analiza obejmowała opracowanie charakterystyk obciążeniowych na podstawie danych dotyczących warunków eksploatacyjnych. Na podstawie danych konstrukcyjnych zostały opracowane modele obliczeniowe analizowanej konstrukcji. Ich badania symulacyjne i analiza wyników dostarczyły informacji o rozkładzie naprężeń w konstrukcji naczepy chłodni. W szczególności skupiono się na przedstawieniu implementacji obciążeń dla przypadku jazdy naczepy na łuku drogi.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2015, 60, 1; 44-49
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variants of strengthening of shells of reinforced concrete cooling towers depending on constructional features and actual technical condition
Opcje wzmocnienia powłok żelbetowych chłodni kominowych w zależności od cech konstrukcyjnych i rzeczywistego stanu technicznego
Autorzy:
Gladyshev, D.
Powiązania:
https://bibliotekanauki.pl/articles/2068363.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
reinforced concrete
cooling tower
prestressed construction
composite
żelbet
chłodnia kominowa
konstrukcja sprężona
kompozyt
Opis:
The article provides design solutions of strengthening of reinforced concrete shells of the cooling towers with the usage of conventional and prestressed outer reinforced concrete ribs and composite materials, which are applied to actual objects in Ukraine and Poland.
Przedstawiono warianty rozwiązań konstrukcyjnych wzmocnienia powłok żelbetowych chłodni kominowych z wykorzystaniem wstępnie sprężonych i zwykłych zewnętrznych żelbetowych żeber lub z materiałów kompozytowych, które są stosowane na rzeczywistych obiektach Ukrainy i Polski.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2015, 21 (171); 75--84
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspects of adapting the cooling installation in a food cold storage system to the applicable f-gas regulations
Autorzy:
Brański, Filip
Ruciński, Adam
Powiązania:
https://bibliotekanauki.pl/articles/1537320.pdf
Data publikacji:
2021
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
cold store
cooling installation
F-Gas Act
refrigerant
chłodnia
instalacja chłodząca
ustawa F-gazowa
chłodziwo
Opis:
The paper presents the methodology of the analysis of the cooling system reconstruction in a food cold store under the regulations applicable from the beginning of 2020. They result from the so-called the F-Gas Act concerns the use of refrigerants with a low environmental impact. First, the elements of the existing regulations on the use of refrigerants were discussed. This part of article focus mainly on the F-Gas Act and the regulations it entails. Then, the refrigerants used so far in refrigeration systems were compared with substitutes, which were the only ones that have been approved for use since 2020, thanks to the low GWP index. Their properties are briefly described, along with the benefits (primarily for the environment) of their use. The main part of the work is the analysis of the reconstruction of the cooling system to use an alternative refrigerant. During the work, the construction of the cold storage was analyzed together with the system currently working in analysed location. Then, the heat balance was calculated, thanks to which it was possible to determine the demand for cold. Than, several refrigerants that meet the latest standards and application regulations were selected. Their operating parameters were examined, the possible variants of use were compared in relation to the determined demand for cooling and the most important operational features were summarized.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2021, 2; 30-42
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of guide vane positions in bended inflow of mechanical draft wet-cooling tower
Autorzy:
Klimanek, A.
Musioł, T.
Stechman, A.
Powiązania:
https://bibliotekanauki.pl/articles/240167.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chłodnia wody obiegowej
optymalizacja
projekt mechaniczny
przepływ wielofazowy
mechanical draft wet-cooling towers
multiphase flow
optimization
Opis:
Optimization of vane positions in a mechanical draft wet-cooling tower is presented in this paper. The originally installed, equally spaced, vanes produced non-uniform air velocity distribution reducing the performance of the fill of the cooling tower. A 2D CFD model of the tower has been created. The model has then been used to determine the objective function in the optimization procedure. The selected objective function was the standard deviation of the velocity of air entering the fill. The Goal Driven Optimization tools of the ANSYS Workbench 2.0 have been used for the optimization and the ANSYS Fluent 13.0 as a flow solver. The optimization allowed reduction of the objective function and producing a more uniform air flow.
Źródło:
Archives of Thermodynamics; 2011, 32, 3; 263-272
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of hyperboloid cooling tower projection on 2D shape
Autorzy:
Kwinta, Andrzej
Bac-Bronowicz, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/2029287.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Rolniczy im. Hugona Kołłątaja w Krakowie
Tematy:
tower measurement
tower analysis
cartographic projection
laser scanning
chłodnia kominowa hiperboidalna
pomiar wieży
projekcja kartograficzna
skanowanie laserowe
Opis:
This paper undertakes the problem of mapping a hyperboloid cooling tower on a single plane. Measurements performed by ground-based laser scanning technology quickly deliver substantial amounts of geometric data of the tower’s outer wall. The essence of the article is projection of the rotational hyperboloid on a plane. The shape of the hyperboloid cooling tower is not directly expandable to a single plane. Mapping a hyperboloid shape on a plane is, therefore, associated with distortions. This paper presents a comparison between cylindrical and conic projection of a hyperboloid cooling tower. The most popular method of mapping hyperboloid is cylindrical projection. The cylinder’s side surface is easily developed on the drawing sheet. For the hyperboloid cooling tower, the biggest distortions occur in the latitudinal direction and reach the highest values at the top and bottom edges. The equation (13) describe distortion for the cylindrical projection. The equation (18) describe distortion for the conical projection. This paper presents results obtained from the performed measurement. The analysis found that cone mapping produces less distortion than cylindrical projection for the hyperboloid cooling tower. We think, that in conical projection, the shape of a hyperboloid cooling tower and theoretical conic shape have better corresponding together than in cylindrical projection.
Źródło:
Geomatics, Landmanagement and Landscape; 2021, 3; 25-40
2300-1496
Pojawia się w:
Geomatics, Landmanagement and Landscape
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal-flow Study of Closed Cooling System with Cooling Towers
Badania cieplno-przepływowe zamkniętego układu chłodzenia z chłodniami kominowymi
Autorzy:
Regucki, P.
Lewkowicz, M.
Krzyżyńska, R.
Powiązania:
https://bibliotekanauki.pl/articles/1813715.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
power plant
closed cooling system
counter flow wet cooling tower
elektrownia
zamknięty układ chłodzenia
przeciwprądowa mokra chłodnia kominowa
Opis:
The paper presents the thermal-flow study of closed cooling system with special emphasis on the working parameters of the cooling tower. The uniqueness of the analysis lays in measurement done inside the working cooling tower to identify thermal-flow processes across its radius. Next, the analysis of a cooling water temperature drop, in the cooling system cooperated with a set of cooling towers, is considered. As an example of these studies there are proposed the optimal cooling water flow rates between two cooling towers to achieve the highest possible water temperature difference in cooling system.
W pracy przedstawiono cieplno-przepływowe badania zamkniętego układu chłodzenia ze szczególnym uwzględnieniem parametrów pracy chłodni kominowych. Unikalność analizy polega na pomiarze wykonanym wewnątrz pracującej chłodni kominowej w celu identyfikacji procesów wymiany ciepła i masy wzdłuż jej promienia. Następnie przeanalizowano stopień schłodzenia wody cyrkulującej w układzie chłodzenia współpracującym z zespołem chłodni kominowych. Jako przykładowy wynik tych badań zaproponowano dobór optymalnych strumieni przepływu wody chłodzącej w układzie dwóch chłodni kominowych, pozwalający uzyskać możliwie najwyższy spadek temperatury (stopień schłodzenia) cyrkulującej wody.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 1; 342-357
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water management at CCGT unit
Optymalizacja gospodarki wodą w bloku gazowo-parowym
Autorzy:
Szaban, J.
Wawrzyński, I.
Powiązania:
https://bibliotekanauki.pl/articles/276594.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
optymalizacja
Ovation
SmartProcess
chłodnia wentylatorowa
Cykl Kombinowany w Wysokosprawnej Kogeneracji
optimization
power plant
cooling towers
Combined Cycle Gas Turbine
Opis:
This paper discusses a water management optimization of cooling towers. Description of a problem solution as well as its industrial application is included. The used software belongs to Emerson's SmartProcess products. It has been applied to two power plants as a part of the Ovation DCS (distributed control system).
W artykule omówiono optymalizacje gospodarki wodnej w chłodni wentylatorowej. Podano opis rozwiązania problemem jak również jego zastosowania w przemyśle. Zastosowano część oprogramowania z pakietu SmartProcess dostarczanego przez Emerson. Pakiet użyto w dwóch elektrowniach, jako uzupełnienie rozproszonego systemu sterowania Ovation.
Źródło:
Pomiary Automatyka Robotyka; 2013, 17, 2; 250-253
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
General energy balance of cold store buildings for food products
Uogólniony bilans energii chłodni do przechowywania żywności
Autorzy:
Bogusławska, Ż
Powiązania:
https://bibliotekanauki.pl/articles/336467.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
żywność
przechowalnictwo
chłodnia
temperatura
wilgotność
właściwości fizyczne
bilans energii
food
storage
cold store
temperature
humidity
physical properties
energy balance
Opis:
The paper discusses the general energy and mass balance of refrigeration systems of food storage objects. To obtain the universality of the description allowing the use of the balance for different kinds of cold store buildings the variability of energy flux as a function of time was taken into account. The presented balance takes into account the possibility of maintaining of the set temperature and air humidity in cold store buildings at variable ambient temperatures (with a daily or annual resolution).
W pracy przedstawiono podstawowy bilans energii i masy opisujący system chłodzenia dowolnego obiektu do przechowywania żywności. W celu uzyskania uniwersalności opisu umożliwiającego jego adaptacje do różnych obiektów w bilansie uwzględniono możliwość zmienności strumieni energii w funkcji czasu. Przedstawiony bilans uwzględnia możliwość utrzymania założonych temperatur i wilgotności powietrza w obiektach chłodniczych przy zmiennych temperaturach otoczenia w okresie dziennym lub rocznym.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2012, 57, 1; 18-20
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies