Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cascade of Lower Vistula" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Hydropower potential of the lower Vistula
Potencjał hydroenergetyczny dolnej Wisły
Autorzy:
Szydłowski, M.
Gąsiorowski, D.
Szymkiewicz, R.
Zima, P.
Hakiel, J.
Powiązania:
https://bibliotekanauki.pl/articles/397485.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
hydropower potential
cascade of dams
lower Vistula
energy production
potencjał hydroenergetyczny
kaskada stopni wodnych
dolna Wisła
produkcja energii
Opis:
This paper presents an estimate analysis of the hydropower potential of the lower Vistula River from Warsaw to Gdańsk Bay. The calculations were made for a hydraulic model of the lower Vistula which takes into account potential development of barrages in a cascade system. Results obtained from the model simulations and from hydrological calculations were used to estimate the power of hydropower plants and the average annual energy output from the entire cascade system. The results of calculations indicate significant energy benefits resulting from the development of a cascade of hydropower plants in the lower Vistula. This study does not discuss the cascade project’s economic viability or other aspects of its development (inland waterways, flood control, etc.).
W artykule przedstawiono szacunkową analizę potencjału hydroenergetycznego dolnej Wisły na odcinku od Warszawy do Zatoki Gdańskiej. Obliczenia wykonano, przyjmując model hydrauliczny dolnej Wisły, w którym uwzględniono potencjalną zabudowę stopniami wodnymi pracującymi w układzie kaskady zwartej. Uzyskane wyniki symulacji z modelu wraz z przeprowadzonymi obliczeniami hydrologicznymi posłużyły do oszacowania mocy elektrowni wodnych oraz średniej rocznej produkcji energii całego układu kaskady. Otrzymane wyniki obliczeń wskazują na znaczące korzyści energetyczne wynikające z budowy kaskady elektrowni wodnych na dolnej Wiśle. W pracy nie podjęto ekonomicznej kwestii opłacalności wykonania analizowanej kaskady, jak również innych aspektów istnienia kaskady (żegluga śródlądowa, ochrona przeciwpowodziowa i inne).
Źródło:
Acta Energetica; 2015, 1; 18-32
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Barrage in Włocławek
Stopień wodny we Włocławku
Autorzy:
Tersa, A.
Powiązania:
https://bibliotekanauki.pl/articles/396901.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
Lower Vistula Cascade
Włocławek Barrage
Włocławek Power Plant
Hydroprojekt Warszawa
barrage operation
barrage repairs
operation of power plant
failure rate of power plant equipment
maintenance costs for barrage structures
Kaskada Dolnej Wisły
stopień wodny
stopień wodny Włocławek
elektrownia Włocławek
eksploatacja stopnia wodnego
remonty stopnia wodnego
eksploatacja elektrowni
awaryjność urządzeń elektrowni
koszty utrzymania obiektów stopnia wodnego
Opis:
The barrage (SW) in Włocławek was designed as one of eight barrages in the Lower Vistula Cascade, located at 674.85 km of the river. It was designed and built entirely by Polish companies. Only turbines were manufactured by the Soviets. The next barrage (in Ciechocinek) has not been constructed, high damming waters passing through the barrage have eroded the bottom at the lower position, whereas the power plant, which has been in peak operation for many years, also contributed to accelerated erosion of the river bed below the barrage, to a reduction of the bottom levels of the river, and, as a consequence, also to a reduction of low water level. Subsequent decisions on water management permits have banned operation of the plant at varying levels of upper water as prevention against the destructive influence of peak operation of the plant by making the conditions for further operation of the barrage stricter. The most significant effects of the 43-year plus operation of Włocławek Barrage, the first in the uncompleted cascade, should include the following: erosion and reduction of water level at the lower position, loosening of the body of the earth dam and the bottom of the weir, damage to concrete structures, damage to steel structures or accumulation of load in Włocławek Reservoir. In the first period of operation of both the barrage and the power plant no major failures were observed, and the operation was smooth, excluding the year 1982, when a powerful ice jamming near Płock contributed to flooding. This also meant quite low costs of barrage operation. The last fifteen years has been a period of increased failure rate of barrage structures and equipment due to a long period of operation, resulting in necessary repairs and modernisation. It has also been a period of increased expenditure.
Stopień wodny (SW) Włocławek był zaprojektowany jako jeden z ośmiu stopni Kaskady Dolnej Wisły, zlokalizowany na 674,85 km rzeki. Zaprojektowany i zbudowany całkowicie przez polskie firmy. Jedynie turbiny były produkcji radzieckiej. Kolejny stopień (w Ciechocinku) nie powstał, wielkie wody wezbraniowe przechodzące przez stopień erodowały dno na dolnym stanowisku, a elektrownia, pracując szczytowo wiele lat, przyczyniała się również do przyspieszonej erozji koryta rzeki poniżej stopnia, obniżania się z roku na rok poziomów dna rzeki, a w konsekwencji również zwierciadła wody dolnej. Kolejne decyzje o pozwoleniu wodnoprawnym, jako przeciwdziałanie destrukcyjnemu oddziaływaniu szczytowej pracy elektrowni, zakazały pracy elektrowni przy zmieniającym się poziomie wody górnej, wprowadzając dodatkowe obostrzenia warunków dalszej pracy stopnia. Do najistotniejszych skutków ponad 43-letniej eksploatacji SW Włocławek, pierwszego w niezrealizowanej kaskadzie, należy zaliczyć: erozję i obniżenie poziomu wody na dolnym stanowisku, rozluźnienie korpusu zapory ziemnej i podłoża jazu, niszczenie konstrukcji betonowych, niszczenie konstrukcji stalowych czy akumulację niesionego rumowiska w zbiorniku włocławskim. W pierwszym okresie eksploatacji zarówno stopnia wodnego, jak i elektrowni nie notowano znaczących awarii, a eksploatacja przebiegała bez zakłóceń, wyłączając rok 1982, kiedy to potężny zator lodowy w okolicach Płocka przyczynił się do powodzi. Oznacza to również niewysokie koszty eksploatacji stopnia. Ostatnie piętnastolecie to okres zwiększonej awaryjności obiektów i urządzeń stopnia wynikającej z długiego okresu eksploatacji, a za tym konieczności remontów i modernizacji. To również okres zwiększonych nakładów.
Źródło:
Acta Energetica; 2013, 3; 79-98
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies