Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "breath analysis" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Improving the accuracy of the NDIR-based CO2 sensor for breath analysis
Autorzy:
Prokopiuk, Artur
Bielecki, Zbigniew
Wojtas, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2052156.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
NDIR
CO2 sensors
breath analysis
absorption spectroscopy
Opis:
The paper presents an analysis and practical study of the temperature and pressure influence on a non-dispersive infrared (NDIR) sensor for measuring the concentration of carbon dioxide in human breath. This sensor is used for monitoring patients’ carbon dioxide (CO2) in the exhaled air. High precision and accuracy of CO2 concentration measurements are essential in air sampling systems for breath analysers. They, however, require an analysis of the influence of the human exhaled air pressure and temperature on the NDIR CO2 sensor. Therefore, analyses of the changes in concentration were carried out at a pressure from 986 mbar to 1027 mbar and a temperature from 20°C to 36°C. Finally, corresponding correction coefficients were determined which allow to reduce the relative uncertainty of CO2 sensor measurements results from 19% to below 5%.
Źródło:
Metrology and Measurement Systems; 2021, 28, 4; 803-812
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exhaled breath analysis by resistive gas sensors
Autorzy:
Chludziński, Tomasz
Kwiatkowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/221713.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resistive gas sensors
data processing
exhaled breath analysis
Opis:
Breath analysis has attracted human beings for centuries. It was one of the simplest methods to detect various diseases by using human smell sense only. Advances in technology enable to use more reliable and standardized methods, based on different gas sensing systems. Breath analysis requires the detection of volatile organic compounds (VOCs) of the concentrations below individual ppm (parts per million). Therefore, advanced detection methods have been proposed. Some of these methods use expensive and bulky equipment (e.g. optical sensors, mass spectrometry - MS), and require time-consuming analysis. Less accurate, but much cheaper, are resistive gas sensors. These sensors use porous materials and adsorption-desorption processes, determining their physical parameters. We consider the problems of applying resistive gas sensors to breath analysis. Recent advances were underlined, showing that these economical gas sensor scan be efficiently employed to analyse breath samples. General problems of applying resistive gas sensors are considered and illustrated with examples, predominantly related to commercial sensors and their long-term performance. A setup for collection of breath samples is considered and presented to point out the crucial parts and problematic issues.
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 81-89
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instrumental techniques used in the analysis of exhaled air
Autorzy:
Kalinowska, K.
Wojnowski, W.
Namieśnik, J.
Powiązania:
https://bibliotekanauki.pl/articles/1179564.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Breath analysis
Diagnosis
Disease-state monitoring
Lung disease
Metabolic disorder
Volatile organic compound
Opis:
Exhaled air composition changes depending on the health status of the patient, making it possible to use breath analysis for diagnosis and monitoring purposes. Despite the fact that it is not yet used in every day medical practice, it potential application could facilitate the diagnostics of various diseases such as metabolic disorders, respiratory tract and gastrointestinal diseases. Described in this paper are different application of exhaled air analysis. Additionally, currently available techniques of sample analysis are discussed, as well as their potential advantages and disadvantages.
Źródło:
World Scientific News; 2017, 75; 64-72
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exhaled breath analysis - quantifying the storage of lipophilic compounds in the human body
Analiza wydechu - oznaczanie zawartości związków lipofilowych w organizmie człowieka
Autorzy:
Amann, A.
King, J.
Kupferthaler, A.
Uterkofler, K.
Koc, H.
Teschl, S.
Hinterhuber, H.
Powiązania:
https://bibliotekanauki.pl/articles/126188.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
exhaled breath analysis
isoprene
proton transfer reaction mass spectrometry (PTR-MS)
analiza wydechu człowieka
izopren
metoda reakcji przeniesienia protonu wraz ze spektrometrią mas (PTR-MS)
Opis:
Real-time analysis of exhaled breath is a promising new method to get quantitative information on lipophilic compounds stored in the human body. Some pilot results are presented on isoprene, which is produced as a by-product of the cholesterol synthesis and appears in exhaled breath at concentrations of about 100 parts-per-billion (ppb). The results have been obtained using proton transfer reaction mass spectrometry (PTR-MS) from healthy volunteers undergoing an ergometer challenge test (with 75 W). Peak exhalation flow of isoprene is about 400 nmol/min shortly after start of the challenge. The setup holds great potential in capturing continuous dynamics of non-polar, low-soluble VOCs over a wide measurement range with simultaneous recording of physiological parameters affecting exhalation kinetics.
Przedstawiono wstępne wyniki oznaczenia stężenia izoprenu w wydechu zdrowego człowieka. Izopren jest produktem ubocznym reakcji syntezy cholesterolu. Do oznaczenia zastosowano metodę reakcji przeniesienia protonu przy wykorzystaniu spektrometrii mas (PTR-MS).
Źródło:
Proceedings of ECOpole; 2009, 3, 1; 9-13
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies