Tytuł:
Identification and evaluation of the characteristics of a selected commercial MEMS based vibration sensor for the machine condition monitoring
Autorzy:
Augustyn, Damian
Fidali, Marek
Powiązania:
https://bibliotekanauki.pl/articles/27313824.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
digital accelerometers
MEMS accelerometers
machine diagnostics
vibration measurements
CbM
akcelerometr
akcelerometr MEMS
diagnostyka maszyn
pomiar drgań
Opis:
With the emergence of the Industry 4.0 concept, machine vibration monitoring and diagnostics systems based on the so-called smart vibration sensors using MEMS accelerometers become very popular on the market. Many automation companies use specifically designed for CbM industrial vibration sensors based on electronic chips with enclosed MEMS accelerometers. However, in the commercial vibration sensors datasheets very often are not provided detailed metrological parameters like frequency response in the declared frequency band. The article presents the results of research concerned to identification of frequency response of an exemplary available on market digital accelerometer dedicated to machines condition monitoring. The determined characteristics indicate that the sensor can be used for basic diagnostics of machines in accordance to the series of vibration standards ISO 10816 and ISO 20816. On the basis of the determined characteristics, it can be concluded that there are some non-linarites of the frequency response functions at the boundaries of the declared measurement band. It shows that application of that sensor to precise measurements conducted during scientific research could be limited.
Źródło:
Diagnostyka; 2023, 24, 4; art. no. 2023404
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Principle of operation and use of accelerometry in assessing the musculoskeletal system – a narrative review
Zasada działania i zastosowanie akcelerometrii w ocenie układu ruchu – przegląd narracyjny
Autorzy:
Grzebień, Paweł
Szczygieł, Elżbieta
Król, Sylwia
Mazur, Tadeusz
Golec, Joanna
Szot, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1963030.pdf
Data publikacji:
2011
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
shock absorption
accelerometer
Gait
absorpcja wstrząsów
akcelerometr
chód
Opis:
Accelerometry is a relatively new but promising method of gait examination. It is based on the usage of sensors which measure linear acceleration at a certain material point. The purpose of this article is to review the literature on the subject from the point of view of applying this technique in assessing human gait, its advantages and shortcomings and the reliability of measurement. Papers by various authors have been reviewed and their results compared. Research concerned detection of the phases and events of gait, calculation of gait parameters such as speed and step length, balance evaluation and the monitoring of physical activity. In order to verify the correctness of the collected data, it was compared with the readings of the VICON system, force platforms and special electronic walkways. An analysis of the literature resulted in the following conclusions: the advantages of accelerometry is the low cost of devices, their small size and mass and measurement which is not limited to the laboratory. The disadvantage is first of all the necessity to use cables, which makes it harder to conduct the long-term monitoring of physical activity. The method is reliable if the experiment is properly planned and carried out. The most important conditions are the proper location of sensors, tight binding to the body, the most accurate alignment of the anatomical axis with the measurement axis and the usage of a proper algorithm for data processing. The authors of the majority of papers consider accelerometry to be a reliable and useful method of analyzing the parameters of gait. At present, accelerometers are used mainly for examining the model of gait and assessing dysfunctions, as sensors in FES assisted walking in patients with dropped foot and during physical activity monitoring.
Akcelerometria jest stosunkowo młodą, ale obiecującą metodą w dziedzinie badań nad chodem. Bazuje ona na zastosowaniu czujników mierzących przyspieszenie liniowe występujące w danym punkcie materialnym. Celem tego artykułu jest przegląd literatury pod kątem zastosowania tej techniki w ocenie lokomocji człowieka, zalet i wad oraz rzetelności pomiaru. Przeglądnięto prace różnych autorów i porównano ich wyniki. Badania dotyczyły wykrywania faz chodu, obliczania parametrów takich jak prędkość czy długość kroków, oceny równowagi oraz monitorowania aktywności fizycznej. W celu sprawdzenia poprawności zarejestrowanych danych, porównywano je z odczytami systemu VICON, platform dynamometrycznych oraz specjalnych elektronicznych ścieżek. Analiza literatury dostarczyła następujących wniosków. Zaletami akcelerometrii jest niski koszt urządzeń, ich niewielkie rozmiary oraz masa, a także brak ograniczenia pomiaru do wnętrza laboratorium. Wady to przede wszystkim konieczność stosowania kabli, co utrudnia długotrwały monitoring aktywności fizycznej. Metoda jest rzetelna, o ile eksperyment jest prawidłowo zaplanowany i przeprowadzony. Najważniejsze warunki to właściwe umiejscowienie czujników, zapewniające dobre przyleganie do ciała mocowanie, jak najdokładniejsze skoordynowanie osi anatomicznej z osią pomiaru oraz uŜycie właściwego algorytmu przetwarzania danych. Autorzy większości prac uznają akcelerometrię jako wiarygodną i przydatną metodę do oceny parametrów chodu. Obecnie akcelerometry znajdują zastosowanie głównie przy badaniu wzorca chodu i oceny dysfunkcji, jako czujniki FES u pacjentów z opadającą stopą oraz podczas oceny równowagi oraz monitorowania aktywności fizycznej.
Źródło:
Medical Rehabilitation; 2011, 15(1); 25-33
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Allan variance in gyroscopic sensor noise analysis
Autorzy:
Kotas, R.
Kamiński, M.
Marciniak, P.
Sakowicz, B.
Napieralski, A.
Kurzych, A.
Krajewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397740.pdf
Data publikacji:
2017
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
Allan variance
gyroscope
accelerometer
MEMS
wariancja Allana
żyroskop
akcelerometr
Opis:
The paper presents the investigation of gyroscopic sensor noise properties used in the construction of body position detection device for posturographic testing. The first part shows the sources of noise in gyro sensors and their measurement methods. In the second part of the paper, the authors describe their own research on the efficiency of the calculation of the Allan variance (one of the popular noise evaluation methods) and the wrong concept of calculations acceleration. The article concludes with an explanation of the reasons for the lack of theoretical research and the results of practical measurements of the sensors used in the project.
Źródło:
International Journal of Microelectronics and Computer Science; 2017, 8, 1; 10-15
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring the dynamic deformation of the bridge structures by accelerometers
Autorzy:
Lipták, I.
Powiązania:
https://bibliotekanauki.pl/articles/225618.pdf
Data publikacji:
2013
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
accelerometer
double integration
deformation
spectral analysis
akcelerometr
deformacja
analiza spektralna
Opis:
The paper presents current trends in determining the dynamic deformations of bridge structures through the exploitation of geodetic measurements by accelerometers. The main aim of the paper is to demonstrate the practical application of these measurements on the cycling bridge over the river Morava in Devínska Nová Ves. Possibilities for the processing and analysis of accelerometer measurements by spectral analysis are described. An evaluation of the results is realized based on the modal characteristics from a numerical model designed by the finite element method.
Źródło:
Reports on Geodesy; 2013, z. 1/94; 37-46
0867-3179
Pojawia się w:
Reports on Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory investigations of dynamic properties of fractional-order accelerometers
Badania laboratoryjne właściwości dynamicznych akcelerometrów niecałkowitych rzędów
Autorzy:
Luft, M.
Szychta, E.
Pietruszczak, D.
Powiązania:
https://bibliotekanauki.pl/articles/252402.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
akcelerometr
przetwornik pomiarowy
dynamika przetworników
accelerometer
measuring transducer
transducer dynamics
Opis:
The paper shows possibilities of using fractional calculus in dynamic measurements. It describes a laboratory measurement system for investigating dynamic properties of measuring transducers. Transducer’s dynamics are identified by the ARX method. Properties of the examined transducers of integral and fractional orders are compared. The authors indicate the fractional calculus advantages from the point of view of their dynamics description.
W artykule przedstawiono możliwości zastosowania rachunku różniczkowo-całkowego niecałkowitych rzędów w miernictwie dynamicznym. Przedstawiono układ pomiarowy do badań właściwości dynamicznych akcelerometrów W procesie identyfikacji przetwornika pomiarowego zastosowano metodę ARX. Porównano właściwości dynamiczne przetwornika pomiarowego całkowitego i niecałkowitego rzędu. Wskazano na zalety zastosowania rachunku różniczkowocałkowego niecałkowitych rzędów do opisu dynamiki przetworników pomiarowych.
Źródło:
TTS Technika Transportu Szynowego; 2013, 10; 423-436, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Saccadic eye movements and their influence on kinematics of several body segments in the elderly while standing
Autorzy:
Bizovska, Lucia
Vagaja, Milena
Mihalova, Diana
Janura, Miroslav
Powiązania:
https://bibliotekanauki.pl/articles/306872.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
akcelerometr
entropia
pierwiastek kwadratowy
accelerometer
sample entropy
root-mean-square
Opis:
It is well known that postural stability is influenced by visual stimuli. The influence of saccadic eye movement on postural control has been described, however, a specific response of different body segments has not been studied yet. Therefore, the aim of this study was to assess the effect of horizontal and vertical saccadic eye movements on postural stability with specific focus on upper trunk, lower trunk and lower limbs movement variability and complexity. Methods: Eighteen elderly participants (aged 70.3 ± 7.7 years) stood in bipedal stance in three visual conditions – horizontal saccades, vertical saccades and fixation. Accelerometers were attached to their lower back, sternum and shanks. Movement variability of each body segment was described by root-mean-square and sample entropy of acceleration. Results: The results of the present study revealed significant influence of saccadic eye movements on anterior-posterior and vertical shanks, and vertical lower trunk movement variability described by root-mean-square. Conclusions: The correlations between results of the observed segments showed segment-specific variability patterns but generalised complexity pattern.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 2; 121-126
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fall detection of the elderly using a smartphone
Autorzy:
Dobosz, K.
Wreczycki, P.
Powiązania:
https://bibliotekanauki.pl/articles/333233.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
elderly
fall detection
smartphone
accelerometer
osoby starsze
detekcja upadków
smartfon
akcelerometr
Opis:
Fall detection of the elderly is a major public health problem. The probability of falls makes them dependent on others and restricts their freedom of movement. Although many fall detection methods have been developed to recognize falls in a real-time, most are inaccurate and inconvenient to use. In this paper we describe two methods for detecting the fall of a human body that can be implemented for the smartphones with built-in accelerometer. The first one used the raw data obtained from the sensor, and the second one - filtered data. In addition to the measuring a load factor, an important role in the algorithms has also a mobile device orientation to the ground. The assumption for the study was the localization of the smartphone in a right pocket of trousers - common in right-handed people. The experiment consisted in simulation the falls from different initial postures (standing, sitting, kneeling) in four directions (front, back, left, right). The results are satisfactory for detection of falls from a standing position. In conclusion, correct detection of falls based on the accelerometer built into the smartphone is possible after the filtration of the raw data, although the location of this device, the initial body position and direction of the fall have significant impact.
Źródło:
Journal of Medical Informatics & Technologies; 2016, 25; 19-27
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiaxial transducers calibration
Autorzy:
Pieniążek, J.
Grądek, P.
Powiązania:
https://bibliotekanauki.pl/articles/243927.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
accelerometer
calibration
auto-calibration
nonlinear regression
akcelerometr
kalibrowanie
autokalibracja
regresja nieliniowa
Opis:
The aim of present article is investigating properties of accelerometer calibration method, called automatic calibration. The research of transducer's model was conducted and chosen optimization algorithms were rated by the simulation method and also using real transducer. The aim of tests was examination of the possibility to find parameters of the transducer model considering influence of temperature and deviation of axes. Described optimal calibration process without special calibration apparatus considers also influence of temperature on acceleration measurement. Afterward, described calibration method was tested on real transducer. Obtained results show that the hybrid two-step algorithm is suitable to the multiaxial transducers calibration. In the research, accelerometer as triaxial transducer was chosen and subjected to tests and the results of simulation was recorded in the MATLAB workspace. From existing estimation, three algorithms were chosen: the quasi-Newton, simplex (Nelder-Mead), and Levenberg-Marquard. The experimental part of the calibration utilized the idea of using existing and known constant vector of the measured value like gravitational acceleration and magnetic field. Calibration with temperature compensation of real transducer was presented.
Źródło:
Journal of KONES; 2017, 24, 1; 299-308
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of selected dynamic properties of quasi-fractional-order measuring transducer used in transportation facilities
Autorzy:
Luft, M.
Cioć, R.
Pietruszczak, D.
Powiązania:
https://bibliotekanauki.pl/articles/393984.pdf
Data publikacji:
2014
Wydawca:
Polskie Stowarzyszenie Telematyki Transportu
Tematy:
measuring transducer
accelerometer
fractional calculus
MATLAB
Simulink
przetwornik pomiarowy
akcelerometr
rachunek ułamkowy
Opis:
The paper presents possibilities of using fractional calculus in dynamic measurements used in telematic equipment in cars and railway vehicles diagnostic systems. It describes a laboratory measurement system for investigating dynamic properties of accelerometers. Tests are executed in the MATLAB&Simulink programme. Properties of the examined transducers of integral and quasi-fractional-orders are compared. The authors indicate the fractional calculus advantages from the point of view of their dynamics description.
Źródło:
Archives of Transport System Telematics; 2014, 7, 3; 17-21
1899-8208
Pojawia się w:
Archives of Transport System Telematics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Capacitive MEMS accelerometer with open-loop switched-capacitor readout circuit
Autorzy:
Szermer, M.
Amrozik, P.
Zając, P.
Maj, C.
Napieralski, A.
Powiązania:
https://bibliotekanauki.pl/articles/397869.pdf
Data publikacji:
2017
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
MEMS
ASIC
accelerometer
integrated circuit
balance disorders
akcelerometr
układy scalone
zaburzenia równowagi
Opis:
MEMS are one of the fastest developing branch in microelectronics. Many integrated sensors are widely used in smart devices i.e. smartphones, and specialized systems like medical equipment. In the paper we present the main parts of a system for measuring human movement which can be used in human balance disorder diagnosis. We describe our design of capacitive accelerometers and dedicated switched-capacitor readout circuit. Both will be manufactured as separate chips in different technological processes. The principle of operation, schematics and layouts of all parts of the system are presented. Preliminary simulations show that the proposed designs are applicable for the considered medical device.
Źródło:
International Journal of Microelectronics and Computer Science; 2017, 8, 4; 139-145
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research of cyclist’s spine dynamical model
Autorzy:
Griskevicius, J.
Linkel, A.
Pauk, J
Powiązania:
https://bibliotekanauki.pl/articles/306676.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
accelerometer
bicycling
biomechanical model
dynamics
spine
akcelerometr
rower
model biomechaniczny
dynamika
kręgosłup
Opis:
The purpose of the paper is to present a dynamic model of bicyclist’s lumbar spine for the evaluation of linear and angular variation of intervertebral distance in sagittal plane. Ten degrees of freedom biomechanical model of the spine was solved numerically. Larger loads acting on a cyclist spine occur mostly while sitting in a sport position in comparison with recreation or middle sitting. The load on lumbar spine region is influenced by cycle’s tire pressure, road bumps and wheeling speed. The biggest linear and angular displacements were found between L4–L5 vertebras. The biggest load protractile spine muscle experiences in the sport sitting position. Maximum vertebrae rotation and linear variation values in wheeling regime with 1.5 Bar tyres pressure and at a speed of 10 km/h are 0.46° and 0.46 mm. Maximum vertebrae rotation and linear variation values for a 23 year old, 1.74 m high and 73 kg of mass (bicycle mass ~ 7 kg) man in wheeling regime with 3.5 Bar tyres pressure and at a speed of 30 km/h are 3.9° and 1.23 mm. The biggest variation of rotation in sagittal plane between two nearest lumbar spines is about 1°. Because of this displacement the frontal part of last mentioned disc is compressed with 530 N more and dorsal disc part as much less.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 1; 37-44
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A static calibration of mems 3-axis accelerometer using a genetic algorithm
Autorzy:
Marinov, Marin
Petrov, Zhivo
Powiązania:
https://bibliotekanauki.pl/articles/198726.pdf
Data publikacji:
2019
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
MEMS accelerometers
calibration
bias
genetic algorithm
akcelerometr MEMS
kalibracja
obciążenie
algorytm genetyczny
Opis:
In this paper, a procedure for MEMS accelerometer static calibration using a genetic algorithm, considering non-orthogonality was presented. The results of simulations and real accelerometer calibration are obtained showing high accuracy of parameters estimation.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2019, 105; 157-168
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of anterior cruciate ligament reconstruction on accelerometric gait analysis
Wpływ przebytej rekonstrukcji więzadła krzyżowego przedniego na akcelerometryczną analizę chodu
Autorzy:
Golec, Joanna
Wójcik, Krzysztof
Bar, Agnieszka
Szczygieł, Elżbieta
Czechowska, Dorota
Masłoń, Agata
Tomaszewska, Iwona M
Powiązania:
https://bibliotekanauki.pl/articles/1798601.pdf
Data publikacji:
2017
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
trauma disorder
ACL
gait analysis
acceleration
accelerometer
uszkodzenie urazowe
analiza ruchu
przyspieszenie
akcelerometr
Opis:
ACL injuries – next to damage to the collateral ligaments, menisci of the knee – are the most common injuries of the knee joint and very often require surgical treatment. The main aim of the treatment is to restore normal gait pattern. The objective of this study was to determine the influence of reconstructed ACL on selected gait parameters by using an accelerometer system. The study involved 34 people aged 18-54 who were divided in two groups. The first group consisted of 20 people after ACL reconstruction, aged 19-54 years old (mean 29). The second group consisted of 14 healthy people between the age of 18-45 (mean 25.36). Gait analysis in normal and fast rate was performed using the CQMotion Electronik System, MEMS type. Differences in the results were observed in the first group. In 75% of people during normal walking and in 95% during fast walking, a 5% difference between the healthy limb and the limb after ACL reconstruction was observed. The gait rate had influence on acceleration value which was observed in RMS values in both of the groups. The RMS value was different, depending on the gait rate. Accelerometric gait analysis shows that the differences in comparing rate values between limbs are not so great, however, the gait pace has influence on some gait parameters. parameters.
Wstęp: Uszkodzenia ACL – obok uszkodzeń więzadeł pobocznych, łąkotek stawu kolanowego – należą do jednych z najczęstszych obrażeń stawu kolanowego, wymagających bardzo często rekonstrukcji chirurgicznej. Przywrócenie prawidłowego wzorca chodu staje się głównym celem leczenia. Celem pracy była ocena wpływu przebytej rekonstrukcji więzadła krzyżowego przedniego (ACL) na wybrane parametry chodu w ocenie akcelerometrycznej. Materiał i metody: W badaniach wzięły udział 34 osoby w wieku 18-54 lat. Do pierwszej grupy włączono 20 osób po przebytej rekonstrukcji ACL w wieku 19-54 lat ( =29 lat). Do drugiej grupy zakwalifikowano 14 zdrowych osób bez uszkodzeń narządu ruchu w wieku 18-45 lat ( =25,36 lat). Przeprowadzono analizę chodu we własnym oraz szybkim tempie przy użyciu CQMotion Elektronik System typu MEMS. Wyniki: W pierwszej grupie, u 75% osób w czasie chodu wolnego, a u 95% podczas chodu szybkiego, wykazano różnicę przekraczającą 5% między kończyną zdrową a poddaną rekonstrukcji ACL. Szybkość chodu miała wpływ na wartość przyspieszenia zaobserwowaną w wartościach RMS w obu grupach. Wartość RMS była różna w zależności o tempa chodu. Wnioski: Akcelerometryczna analiza chodu pokazała, iż nie odnotowano dużych różnic w porównywanych wartościach przyspieszenia pomiędzy kończynami, natomiast tempo chodu miało wpływ na wybrane parametry chodu.
Źródło:
Medical Rehabilitation; 2017, 21(1); 4-11
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of vortex induced vibration of a gravity damper
Autorzy:
Scappaticci, L.
Castellani, F.
Astolfi, D.
Garinei, A.
Powiązania:
https://bibliotekanauki.pl/articles/328322.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
mechanical systems
vibration analysis
computational mechanics
accelerometers
układy mechaniczne
analiza drgań
mechanika komputerowa
akcelerometr
Opis:
A gravity damper is a one-way valve, employed for regulating the airflow rate in ducts, generally constituted by a series of rectangular panels (closure sections), connected to an articulated quadrilateral synchronizing the movements. If the device needs to process large masses of high speed air, as common in the case of energy conversion systems, disadvantageous dynamic effects can occur. In this study, vortexinduced vibration (VIV), occurring on a gravity damper for high values of the Reynolds number, is investigated. The analysis of this work couples numerical methods (Computational Fluid Dynamics with Large-Eddy Simulation turbulence model and Finite Element Method) to experiments: a full-scale accelerometric measurement campaign is actually performed at the wind tunnel facilities of the University of Perugia. VIVs are diagnosed and quantified through the experimental vibration analysis, which is interpreted through numerical simulations. The large amplitude of VIV is interpreted as due to a tendency towards lockin because of the approaching of the vortex shedding frequency to a natural vibration mode of the system. The integrated numerical and experimental framework finally inspires two different design solutions for mitigating the amplitude of VIV: these strategies are tested at the wind tunnel and they are indeed shown to be effective.
Źródło:
Diagnostyka; 2018, 19, 2; 31-39
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration and evaluation of accelerometers based on multisinusoidal excitation
Wyznaczanie charakterystyk akcelerometrów z wykorzystaniem pobudzenia wielosinusoidalnego
Autorzy:
Buchczik, D.
Pawelczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/327185.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
accelerometers
calibration
uncertainty of measurements
vibration measurements
akcelerometr
kalibracja
niepewność wyników pomiarów
pomiar drgań
Opis:
Vibrational diagnostics of machines is usually based on use of accelerometers. Their calibration is required in order to obtain reliable results. This paper presents method for calibration of accelerometers using a multisinusoidal excitation. There is also proposed a procedure for estimating uncertainty of the obtained characteristics. The routine is based on an analysis of signals in the frequency domain using evaluation of cross power spectral density between the signals from the calibrated and standard accelerometer and evaluation of power spectral density of the signal from the standard accelerometer. The procedure allows to determine the nominal sensitivity, amplitude-frequency characteristics and estimate their uncertainties. The experiments were performed using a piezoelectric sensor PCB 338B35, and a sensor based on ADXL 202 capacitive accelerometer constructed at Silesian University of Technology. Results of this study show that the proposed method can be successfully used. The main advantage of the routine is a very short duration of the measurement experiment. Values of estimated relative uncertainties reach several percent. The procedure can be applied when it is necessary to quickly check the sensor characteristics, for example in the field for periodical maintenance of sensors mounted on the machine.
Diagnostyka wibracyjna maszyn jest zwykle oparta na wykorzystaniu akcelerometrów. Ich kalibracja jest konieczna w celu uzyskania wiarygodnych wyników pomiarów. W artykule przedstawiono metodę wyznaczania charakterystyk akcelerometrów przy użyciu pobudzenia wielosinusoidalnego. Zaproponowano również procedurę szacowania niepewności uzyskanych parametrów. Metoda opiera się na analizie sygnałów w dziedzinie częstotliwości, przy wykorzystaniu oceny wzajemnej gęstości widmowej mocy pomiędzy sygnałami z czujników kalibrowanego i referencyjnego oraz oceny gęstości widmowej mocy sygnału z czujnika referencyjnego. Procedura umożliwia określenie czułości nominalnej, charakterystyki amplitudowoczęstotliwościowej oraz oszacowanie ich niepewności. Eksperymenty przeprowadzono stosując czujnik piezoelektryczny PCB 338B35 oraz czujnik oparty na akcelerometrze ADXL 202 skonstruowanym na Politechnice Śląskiej. Wyniki badań wskazują, że proponowaną metodę można z powodzeniem stosować. Główną zaletą procedury jest bardzo krótki czas trwania eksperymentu pomiarowego. Oszacowane względne niepewności osiągają kilkanaście procent. Procedura może być stosowana, gdy konieczne jest szybkie sprawdzenie charakterystyki czujnika, na przykład w warunkach polowych, przy okresowej konserwacji czujników zamontowanych na monitorowanej maszynie.
Źródło:
Diagnostyka; 2017, 18, 4; 79-87
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies