Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Spadek ciśnienia" wg kryterium: Temat


Tytuł:
Numerical simulation of nanofluid flow in a small diameter pipe
Numeryczna symulacja przepływu nanopłynu przez kanał o małej średnicy
Autorzy:
Lemanowicz, M.
Dzido, G.
Gierczycki, A.
Witkowski, M.
Drzazga, M.
Powiązania:
https://bibliotekanauki.pl/articles/2072026.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nanopłyny
spadek ciśnienia
CFD
nanofluids
pressure drop
Opis:
The research concerning nanofluid pressure drop during flow through a small diameter pipe is presented. Experimental results are compared with the computational fluid dynamics (CFD) simulations. The flow of copper nanoparticles suspended in water through the cylindrical tube of 12 mm diameter was investigated. In simulations single-phase as well as multiphase approaches were employed. It was proven that both ways of simulations gave similar results.
Przedstawiono efekty badań dotyczących spadku ciśnienia przy przepływie nanopłynu przez kanał o malej średnicy. Wyniki eksperymentalne porównano z rezultatami symulacji z wykorzystaniem numerycznej mechaniki płynów (CFD). Zbadano przepływ nanocząstek tlenku miedzi zawieszonych w wodzie przez przewód cylindryczny o średnicy 12 mm. W symulacjach wykorzystano zarówno podejście jednofazowe jak i wielofazowe. Wykazano, iż oba sposoby prowadzenia symulacji dały podobne rezultaty.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 6; 541--542
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of pressure drop during refrigerant condensation in pipe minichannels
Autorzy:
Sikora, M.
Bohdal, T.
Powiązania:
https://bibliotekanauki.pl/articles/240860.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
minichannels
pressure drop
refrigerant
condensation
minikanał
spadek ciśnienia
chłodziwo
kondensacja
Opis:
Investigations of refrigerant condensation in pipe minichannels are very challenging and complicated issue. Due to the multitude of influences very important is mathematical and computer modeling. Its allows for performing calculations for many different refrigerants under different flow conditions. A large number of experimental results published in the literature allows for experimental verification of correctness of the models. In this work is presented a mathematical model for calculation of flow resistance during condensation of refrigerants in the pipe minichannel. The model was developed in environment based on conservation equations. The results of calculations were verified by authors own experimental investigations results.
Źródło:
Archives of Thermodynamics; 2017, 38, 4; 15--28
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the pressure drop calculation method impact on the accuracy of the experimental results in the Koflo® static mixer
Analiza wpływu metody obliczeń spadku ciśnienia w mieszalniku statycznym Koflo® na dokładność odwzorowania wyników doświadczeń
Autorzy:
Stec, M.
Synowiec, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/2073099.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Koflo® static mixer
pressure drop
CFD
mieszalnik statyczny Koflo®
spadek ciśnienia
Opis:
The presented paper is a continuation of previously one and it focuses on the validation of the developed Koflo static mixer numerical model (created for pressure drop predictions by use of CFD techniques) on the basis of experimental data. It also presents the new equation that can be used for pressure drop calculations and shows the comparison of different, commonly used static mixers types with the analyzed, unrecognized in the literature Koflo mixer.
Artykuł jest kontynuacją poprzedniej publikacji i skupia się na walidacji opracowanego modelu numerycznego mieszalnika statycznego Koflo (wykorzystywanego do określania spadków ciśnienia podczas przepływu cieczy jednorodnej w reżimie burzliwym) w oparciu o dane eksperymentalne. Podano nowe równanie do obliczania spadków ciśnienia podczas przepływu cieczy przez mieszalnik, a i przedstawiono porównanie innych komercyjnych mieszalników z analizowanym i dotychczas nierozpoznanym w literaturze mieszalnikiem Koflo.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 4; 201--203
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental investigation of the two-phase flow regimes and pressure drop in horizontal mini-size rectangular test section
Autorzy:
Elazhary, A.
Soliman, H.
Powiązania:
https://bibliotekanauki.pl/articles/239912.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dwufazowy
minikanał
przepływ
spadek ciśnienia
flow regimes
mini channel
pressure drop
two-phase
Opis:
An experimental study was conducted in order to investigate two-phase flow regimes and fully developed pressure drop in a mini-size, horizontal rectangular channel. The test section was machined in the form of an impacting tee junction in an acrylic block (in order to facilitate visualization) with a rectangular cross-section of 1.87-mm height on 20-mm width on the inlet and outlet sides. Pressure drop measurement and flow regime identification were performed on all three sides of the junction. Air-water mixtures at 200 kPa (abs) and room temperature were used as the test fluids. Four flow regimes were identified visually: bubbly, plug, churn, and annular over the ranges of gas and liquid superficial velocities of 0.04 [ less than or equal to] JG [ less than or equal to] 10 m/s and 0.02 [ less than or equal to] JL [ less than or equal to] 0.7 m/s, respectively, and a flow regime map was developed. Accuracy of the pressure-measurement technique was validated with single-phase, laminar and turbulent, fully developed data. Two-phase experiments were conducted for eight different inlet conditions and various mass splits at the junction. Comparisons were conducted between the present data and former correlations for the fully developed two-phase pressure drop in rectangular channels with similar sizes. Wide deviations were found among these correlations, and the correlations that agreed best with the present data were identified.
Źródło:
Archives of Thermodynamics; 2012, 33, 2; 47-6
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical method effect on pressure drop estimation in the Koflo® static mixer
Wpływ metody numerycznej na estymację spadków ciśnienia w mieszalniku statycznym typu Koflo®
Autorzy:
Stec, M.
Synowiec, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/2073035.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
static mixer
Koflo®
pressure drop
CFD
turbulent flow
mieszalnik statyczny
spadek ciśnienia
przepływ burzliwy
Opis:
Pressure drop determines the power required to pump the fluid through the mixer and enables the selection of proper pumping device. In the presented paper there was an attempt to determine the pressure drops over a static mixer using CFD methods and to validate the developed model upon the vendor’s correlation. The study involved one-phase flow in the turbulent regime (Re = 1000÷5000). The numerical and experimental approach was obtained using the Koflo® Static Mixer consisted of 12 motionless mixing inserts installed in a pipe. It can be an interesting alternative to the commonly used Kenics type mixers, due to its simpler geometry and much smaller price. In order to perform numerical simulations a suitable model was created and then covered by generated mesh with an optimized number of elements on basis of the Grid Convergence Index (GCI). Turbulence model and other Fluent-solver settings were also selected. Analyzing the resulting data, a good accuracy between the numerical data and pressure drops calculated from manufacturer’s correlation was observed.
Wartość spadku ciśnienia określa moc niezbędną do przetłoczenia płynu przez mieszalnik i umożliwia dobór odpowiedniego urządzenia pompującego. W pracy określono spadki ciśnienia w mieszalniku statycznym metodami CFD oraz dokonano walidacji opracowanego modelu na podstawie korelacji podawanej przez producenta. Rozpatrywano przepływ jednofazowy w reżimie burzliwym (Re = 1000÷5000). Wykorzystano konstrukcję mieszalnika Koflo®, zawierającą 12 nieruchomych elementów mieszających. Stanowi alternatywę dla powszechnie stosowanych mieszalników typu KENICS, ze względu na prostszą geometrię oraz znacznie niższą cenę. Stworzono odpowiedni model obrazujący geometrię mieszalnika i nałożono siatkę numeryczną posiadającą zoptymalizowaną na podstawie współczynnika GCI (Grid Convergence Index) liczbę elementów. Dokonano także doboru modelu turbulencji i pozostałych ustawień solvera Fluent 15. Analizując uzyskane dane zaobserwowano, że spadki ciśnienia uzyskane na drodze symulacji numerycznych są bliskie wartościom obliczonym w oparciu o wzór producenta.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 2; 48--50
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pressure drop in two-phase gas-liquid (Taylor) flow in microreactors
Autorzy:
Cygański, P.
Sobieszuk, P.
Pohorecki, R.
Powiązania:
https://bibliotekanauki.pl/articles/185780.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przepływ Taylora
przepływ gaz-ciecz
spadek ciśnienia
mikroreaktor
gas-liquid Taylor flow
microreactor
pressure drop
Opis:
The pressure drop in microreactors for the gas - liquid Taylor flow was measured for 4 different microreactor geometries and 3 different gas - liquid systems. The results have been compared with the existing literature correlations. A selection of the best correlations has been made.
Źródło:
Chemical and Process Engineering; 2012, 33, 3; 369-384
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of natural pressure drop in mine main ventilation
Skutki naturalnego spadku ciśnienia w głównej sieci wentylacyjnej kopalni
Autorzy:
Zapletal, P.
Hudecek, V.
Trofimov, V.
Powiązania:
https://bibliotekanauki.pl/articles/219326.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wentylacja kopalni
naturalny spadek ciśnienia
temperatura
wentylator główny
mine ventilation
natural pressure drop
temperature
main fan
Opis:
Natural ventilation in a mine is ventilation without the use of means of artificial ventilation. The flow of mine air is induced by the difference between the mass column in an intake and that in a return. The difference in mine air density is a result of difference between the temperature of intake air and that of return air. To a certain extent, the influence of differences in mine air humidity and chemical composition can act as well. Gassy mines in the Czech Republic and Ukraine are ventilated merely artificially, i.e. by means of exhaust ventilation. However, even in the case of this type of ventilation, when the total mine air flow is produced by fans, a natural current of air exists and acts in the ventilation network of the mine.
Naturalna wentylacja w kopalni to wentylacja bez wykorzystania środków sztucznej wentylacji. Przepływ kolumny powietrza wymuszony jest poprzez różnicę ciśnień pomiędzy kolumną powietrza na wlocie a prądem zużytego powietrza. Różnica w gęstości powietrza kopalnianego wynika z różnicy temperatur pomiędzy powietrzem wlotowym i zużytym. W pewnym stopniu uwidacznia się także wpływ wilgotności powietrza kopalnianego i jego składu chemicznego. Kopalnie gazowe w Republice Czeskiej i na Ukrainie są przewietrzane przy użyciu sztucznej wentylacji, z wykorzystaniem instalacji wyciągowej. Jednakże nawet w przypadku zastosowania tego typu systemu wentylacyjnego w którym przepływ powietrza kopalnianego w całości generowany jest przez wentylatory, nadal istnieją naturalne prądy powietrza, których obecność i działanie ujawnia się w sieci wentylacyjnej.
Źródło:
Archives of Mining Sciences; 2014, 59, 2; 501-508
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bubble boiling in flow of refrigerating media
Autorzy:
Bohdal, T.
Powiązania:
https://bibliotekanauki.pl/articles/95227.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
bubble boiling
heat transfer
pressure drop
tubular channel
wrzenie pęcherzykowe
wymiana ciepła
spadek ciśnienia
kanał rurowy
Opis:
The paper describes results of investigations of heat transfer and pressure drop during bubbly boiling of refrigerating media. In this article were presented of authors own experimental studies and were proposed new simple calculation model describing bubble boiling in the tubular channel. The author attempts to put forward a simplified description of the process of bubble boiling in a straight pipe. The two-phase one-component (liquid-vapour) system is treated as a continuum governed by the laws of conservation of energy, momentum and mass. The continuum is characterised by parameters that describe the two-phase system, such as density of the two-phase mixture, static void fraction or static equilibrium dryness fraction. In view of engineering applications, a one-dimensional model is used where physical quantities are cross-section averaged. This way the average velocity, pressure, temperature, and so on, are introduced. The results of the proposed model have been compared with the results of the experimental research with satisfactory compliance.
Źródło:
Journal of Mechanical and Energy Engineering; 2017, 1, 1; 57-64
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transmission loss and pressure drop of selected range of helicoidal resonators
Autorzy:
Łapka, W.
Powiązania:
https://bibliotekanauki.pl/articles/128014.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
helicoidal resonator
transmission loss
pressure drop
numerical analysis
rezonator helikoidalny
straty transmisyjne
spadek ciśnienia
analiza numeryczna
Opis:
The paper presents the numerical analysis of transmission loss and pressure drop of acoustic helicoidal resonators with constant pitch to cylindrical duct diameter ratio and different number of helicoidal turns n. The ducted system consists of a straight cylindrical duct of constant diameter d=0.125m. The ratio of helicoidal pitch s to cylindrical duct diameter d equals s/d=1,976. Other geometrical relationships of helicoidal resonator, as a mandrel diameter dm to duct diameter ratio dm/d=0.024 and thickness g of helicoidal profile g/d=0.0024, were constant as well. The investigated range of numbers of helicoidal turns n was analyzed in the range from 0 to 2.0 for transmission loss parameter and from 0 to 1.0 for pressure drop. The values of normal inflow velocity v [m/s] equals 1, 5, 10, 15 and 20.
Źródło:
Vibrations in Physical Systems; 2014, 26; 121-128
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative study of heat transfer and pressure drop during flow boiling and flow condensation in minichannels
Autorzy:
Mikielewicz, D.
Andrzejczyk, R.
Jakubowska, B.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/240815.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
two-phase pressure drops
heat transfer coefficient
boiling
condensation
dwufazowy spadek ciśnienia
współczynnik przenikania ciepła
wrzenie
kondensacja
Opis:
In the paper a method developed earlier by authors is applied to calculations of pressure drop and heat transfer coefficient for flow boiling and also flow condensation for some recent data collected from literature for such fluids as R404a, R600a, R290, R32,R134a, R1234yf and other. The modification of interface shear stresses between flow boiling and flow condensation in annular flow structure are considered through incorporation of the so called blowing parameter. The shear stress between vapor phase and liquid phase is generally a function of nonisothermal effects. The mechanism of modification of shear stresses at the vapor-liquid interface has been presented in detail. In case of annular flow it contributes to thickening and thinning of the liquid film, which corresponds to condensation and boiling respectively. There is also a different influence of heat flux on the modification of shear stress in the bubbly flow structure, where it affects bubble nucleation. In that case the effect of applied heat flux is considered. As a result a modified form of the two-phase flow multiplier is obtained, in which the nonadiabatic effect is clearly pronounced.
Źródło:
Archives of Thermodynamics; 2014, 35, 3; 17-37
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of Pressure-Drop Instability in Single and Multi Microchannels System
Autorzy:
Grzybowski, H.
Mosdorf, R.
Powiązania:
https://bibliotekanauki.pl/articles/386991.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
przepływ dwufazowy
niestabilność
mikrokanał
spadek ciśnienia
oscylacja przepływu
two-phase flow
instabilities
microchannels
pressure drop
flow oscillations
Opis:
In the paper the model of pressure-drop oscillations has been proposed. The model was based on the iterative solution to equations. The dynamics of pressure-drop oscillations in a single channel and in two neighbouring channels have been analyzed. There has been assumed that the pressure-drop oscillations in the system are caused by interactions between the heat supply system and liquid supply system. These interactions influence the heat and mass transfer inside the microchannel. Obtained results indicate that the shape of pressure drop curve has a significant influence on the system stability. When the slope of curve ? = () in the region between function extremes increases then the pressure oscillations become chaotic. In case of multichannel system the thermal interactions (occurring through the channel walls) and hydrodynamic interactions (occurring inside the common channels outlet) have been considered. Four types of two-phase flow behaviours in parallel channels have been observed depending on the intensity of interactions: alternate oscillations, consistent oscillations, periodic oscillations and completely synchronized oscillations. Obtained qualitative results have been compared with conclusions of experimental results reported by other researches. The good qualitative agreement with experimental results has been obtained.
Źródło:
Acta Mechanica et Automatica; 2012, 6, 3; 45-51
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of erosion wear and pressure drop for turbulent multiphase slurry flow
Autorzy:
Kannojiya, V.
Darshan, M. B.
Chandra, Y. P.
Powiązania:
https://bibliotekanauki.pl/articles/139624.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
erosion
computational fluid dynamics
CFD
multi-phase flow
pressure drop
erozja
obliczeniowa mechanika płynów
przepływ wielofazowy
spadek ciśnienia
Opis:
The disposal of ash in a thermal plant through the slurry pipe is subjected to some erosion wear due to the abrasive characteristics of the slurry. A simulation study of particle-liquid erosion of mild steel pipe wall based on CFD-FLUENT that considers the solid-liquid, solid-solid and solid-wall interaction is presented in this work.The multi-phase Euler-Lagrange model with standard k- ϵ turbulence modeling is adopted to predict the particulate erosion wear caused by the flow of bottom ash water suspension. Erosion rate for different particle size and concentration is evaluated at variable flow rate. It is observed that the pressure drop and erosion rate share direct relationships with flow velocity, particle size and concentration. The flow velocity is found to be the most influencing parameter. A model capable of predicting the erosion wear at variable operating conditions is presented.The simulation findings show good agreement with the published findings.
Źródło:
Archive of Mechanical Engineering; 2018, LXV, 3; 361-378
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rheological behavior of fly ash suspension with additive for hydraulic conveyance
Autorzy:
Kumar, K.
Powiązania:
https://bibliotekanauki.pl/articles/265278.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
popiół lotny
reologia
lepkość względna
spadek ciśnienia
zużycie energii
fly ash
rheology
relative viscosity
pressure drop
energy consumption
Opis:
In the present work, rheological behaviour of a fine particulate fly ash slurry suspension is studied with and without addition of an additive. Rheological experiments are performed for the range of shear rate from 50 to 200 s1.Sodium sulfate is used as an additive in the fraction of 0.2, 0.4 and 0.6% (by weight). Addition of sodium sulfate to the fly ash slurry suspension leads to an improvement of its rheological characteristics. A reduction in relative viscosity and pressure drop is more pronounced with the addition of sodium sulfate in proportion of 0.4%, while marginal with 0.2 and 0.6% (by weight). The analysis reveals that the fly ash suspension has a potential to for being transported in a slurry pipeline with higher concentration and minimum energy consumption.
Źródło:
International Journal of Applied Mechanics and Engineering; 2020, 25, 2; 202-210
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of compressed heat exchanger efficiency by using genetic algorithm
Autorzy:
Ghorbani, M.
Ranjbar, S. F.
Powiązania:
https://bibliotekanauki.pl/articles/266267.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wymiennik ciepła
spadek ciśnienia
pojemność cieplna
optymalizacja
algorytm genetyczny
heat exchanger
pressure drop
heat capacity
optimization
genetic algorithm
Opis:
Due to the application of coil-shaped coils in a compressed gas flow exchanger and water pipe flow in airconditioner devices, air conditioning and refrigeration systems, both industrial and domestic, need to be optimized to improve exchange capacity of heat exchangers by reducing the pressure drop. Today, due to the reduction of fossil fuel resources and the importance of optimal use of resources, optimization of thermal, mechanical and electrical devices has gained particular importance. Compressed heat exchangers are the devices used in industries, especially oil and petrochemical ones, as well as in power plants. So, in this paper we try to optimize compressed heat exchangers. Variables of the functions or state-of-the-machine parameters are optimized in compressed heat exchangers to achieve maximum thermal efficiency. To do this, it is necessary to provide equations and functions of the compressed heat exchanger relative to the functional variables and then to formulate the parameter for the gas pressure drop of the gas flow through the blades and the heat exchange surface in relation to the heat duty. The heat transfer rate to the gas-side pressure drop is maximized by solving the binary equation system in the genetic algorithm. The results show that using optimization, the heat capacity and the efficiency of the heat exchanger improved by 15% and the pressure drop along the path significantly decreases.
Źródło:
International Journal of Applied Mechanics and Engineering; 2019, 24, 2; 461-472
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cooling of High Heat Flux Flat Surface with Nanofluid Assisted Convective Loop. Experimental Assessment
Autorzy:
Arya, A.
Shahmiry, S.
Nikkhah, V.
Sarafraz, M.M.
Powiązania:
https://bibliotekanauki.pl/articles/139852.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ZnO nanoparticle
pressure drop
heat transfer coefficient
friction factor
nanocząstki ZnO
spadek ciśnienia
współczynnik przenikania ciepła
współczynnik tarcia
Opis:
Experimental investigation was conducted on the thermal performance and pressure drop of a convective cooling loop working with ZnO aqueous nanofluids. The loop was used to cool a flat heater connected to an AC autotransformer. Influence of different operating parameters, such as fluid flow rate and mass concentration of nanofluid on surface temperature of heater, pressure drop, friction factor and overall heat transfer coefficient was investigated and briefly discussed. Results of this study showed that, despite a penalty for pressure drop, ZnO/water nanofluid was a promising coolant for cooling the micro-electronic devices and chipsets. It was also found that there is an optimum for concentration of nanofluid so that the heat transfer coefficient is maximum, which was wt. % = 0.3 for ZnO/water used in this research. In addition, presence of nanoparticles enhanced the friction factor and pressure drop as well; however, it is not very significant in comparison with those of registered for the base fluid.
Źródło:
Archive of Mechanical Engineering; 2017, LXIV, 4; 519-531
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies