Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ramana spectroscopy" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
The control software of the portable Raman spectrometer
Oprogramowanie sterujące przenośnym spektrometrem Raman
Autorzy:
Kwiatkowski, A.
Smulko, J.
Powiązania:
https://bibliotekanauki.pl/articles/266476.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
spektroskopia Ramana
identyfikacja
Raman spectroscopy
identification
Opis:
The paper contains a description of the control software of a portable Raman spectrometer which was built in the Department of Optoelectronics and Electronic Systems Faculty of Electronics, Telecommunications and Informatics Gdansk University of Technology. The software has modular structure, which includes the laser control module and the spectrum acquisition module (laser power selection, working mode and data acquisition time) was described. The module of Raman spectra pre-processing (smoothing, background removal, normalization) was described in detail, with particular emphasis on its ergonomic use. The software was prepared for two different user types (experienced and inexperienced), allowing use by the advanced operator or by the less experienced personnel. The Raman spectra database with updating ability by external databases was presented, together with the selected identification algorithms.
Praca zawiera opis oprogramowania sterującego przenośnym spektrometrem Ramana, który został zbudowany w Katedrze Optoelektroniki i Systemów Elektronicznych Wydziału Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej, w trakcie realizacji grantu rozwojowego. Opisano modułową budowę oprogramowania, zawierającego moduł sterujący pracą laserów oraz procesem akwizycji widma. Bardziej szczegółowo przedstawiono moduły realizujące funkcje wstępnego przetwarzania widm Ramana, ze szczególnym uwzględnieniem ergonomii korzystania z urządzenia w warunkach pomiarów w terenie. Oprogramowanie zrealizowano w koncepcji dwóch użytkowników (zaawansowany i podstawowy), umożliwiając tym samym obsługę urządzania przez doświadczonych operatorów oraz przez personel o ograniczonych kwalifikacjach. Przedstawiono także budowę bazy danych widm Ramana. Scharakteryzowano również algorytmy dokonujące identyfikacji widm.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2011, 30; 81-84
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Raman spectra measurements for chemical identification - aspect of uncertainty sources and reduction of their effects
Problemy pomiarów widm Ramana podczas identyfikacji substancji chemicznych
Autorzy:
Kwiatkowski, A.
Smulko, J.
Wierzba, P.
Powiązania:
https://bibliotekanauki.pl/articles/156092.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
zjawisko Ramana
spektroskopia Ramana
szumy
zakłócenia
etaloning
Raman phenomenon
Raman spectroscopy
noise
interference
etaloning effect
Opis:
Raman spectrometers enable fast and non-contact identification of examined chemicals. These devices measure Raman spectra and compare with the spectra database to identify unknown and often illicit chemicals (e.g. drugs, explosives) usually without any sample preparation. Raman spectra measurements are a challenge due to noise and interferences present outside the laboratories (field applications). The design of a portable Raman spectrometer developed at the Faculty of Electronics, Telecommunications and Informatics, Gdansk University of Technology is presented. The paper outlines sources of noise and interferences (e.g. background removal, spectra smoothing) contaminating Raman spectra measurements as well as signal processing techniques required to reduce their influence. The authors consider influence of packages (glass or plastic vials) on effectiveness of detection of selected chemical mixtures and they propose a method that reduces this factor. Next, the impact of acquisition time and external lighting on the accuracy of Raman spectra measurements is investigated. The synchronic detection is introduced to diminish changes of outside sample irradiation. Finally, the etaloning error present in the measured spectra is considered and attenuated by an additional procedure.
Spektroskopy Ramana umożliwiają szybką i bezkontaktową identyfikację badanej substancji chemicznej. Mierzą widma Ramana i porównują z biblioteką widm, aby identyfikować nieznaną, często nielegalną substancję chemiczną (np. narkotyki, materiały wybuchowe) bez potrzeby przygotowania badanej próbki. Pomiar widm Ramana w warunkach polowych jest dużym wyzwaniem ze względu na obecność wielu źródeł szumów i zakłóceń, m.in. szumy przetworników CCD, fluorescencja, szumy kosmiczne, oświetlenie zewnętrzne. W pracy przedstawiono projekt przenośnego spektrometru Ramana opracowanego na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej. Opisano źródła szumów i zakłóceń obecnych podczas pomiarów widm Ramana oraz techniki przetwarzania sygnałów zmniejszające ich wpływ (np. usuwanie tła, widm wygładzanie). Autorzy rozważają także wpływ opakowań (szklanych lub plastikowych) na efektywność detekcji wybranych mieszanin chemicznych i proponują metodę, pozwalającą na jego redukcję. Następnie przedstawiono zależności między czasem ekspozycji a dokładnością pomiarów widm Ramana. Określono skutki oddziaływania zewnętrznego (niepożądanego) oświetlenia na jakość pomiarów oraz przedstawiono sposób ich ograniczenia przy użyciu pomiarów synchronicznych. Następnie opisano zjawisko etaloningu oraz procedurę jego usunięcia w kontrolowanych warunkach pomiarowych, za pomocą dodatkowych procedur.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1518-1521
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructural characterization of cast magnesium matrix composites by Raman microscopy
Autorzy:
Malik, M. A.
Braszczyńska-Malik, K. N.
Majchrzak, K.
Powiązania:
https://bibliotekanauki.pl/articles/380033.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magnesium matrix composites
SiC
Mg2Si
Raman spectroscopy
kompozyt magnezowy
spektroskopia Ramana
Opis:
Cast magnesium matrix composites reinforced with silicon carbide particles were investigated by using Raman microscopy. 3C, 4H and 6H polytypes of SiC particles were identified in the investigated composites. Additionally, Mg2Si compound was detected by Raman microscopy in the composites microstructure.
Źródło:
Archives of Foundry Engineering; 2013, 13, 1; 95-98
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fish Collagen – Molecular Structure After Thermal Treatment
Kolagen rybi – struktura molekularna i stabilność termiczna
Autorzy:
Paprzycka, M.
Scheibe, B.
Jurga, S.
Powiązania:
https://bibliotekanauki.pl/articles/231570.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
fish collagen gel
biopolymers
Raman spectroscopy
żel kolagenowy z ryb
biopolimery
spektroskopia Ramana
Opis:
Modern medicine widely uses exogenous collagen as a good material for tissue regeneration, also as a natural substrate for cell attachment and proliferation, used to create dressings and to support the treatment of burn and diabetic wounds, or finally as a source of amino acids in the form of a dietary supplement. Collagen is a safe material that has high biocompatibility and biodegradability as well as good cell adhesion. Due to the possibility of transferring Creutzfeld-Jacob’s disease (Bovine Spongiform Encephalopathy) from animals to the human body, interest in collagen from fish is currently increasing. The collagen we examined was derived from the skin of the silver carp fish (Hypophtalmichthys molitrix) and was obtained by the method of hydration in an aqueous lactic acid solution. The topography of the test sample was performed with the AFM method, showing its fibrillar structure with dimensions equivalent to those given in iterature. Raman spectroscopy was used to study fish collagen using a Renishaw Ramanscope with a helium-neon laser at a wavelength of 633 nm. Analysis of Raman spectra allowed to determine the content of amino acids in collagen, as well as glycine, proline and hydroxyproline. It also showed the native nature of the material at 20 °C. The partial renaturation of the secondary structure of this material heated to about 85 °C and cooled was also proved. Raman spectroscopy has been presented as an effective method for testing biopolymers.
Współczesna medycyna szeroko wykorzystuje kolagen egzogenny jako materiał do regeneracji ubytków tkanek miękkich, jako naturalne podłoże do przyłączania i proliferacji komórek, wykorzystywane do tworzenia opatrunków i wspomagania leczenia ran oparzeniowych czy cukrzycowych, czy wreszcie jako źródło aminokwasów w diecie uzupełniającej potrzeby organizmu. Kolagen jest materiałem bezpiecznym, posiadającym dużą biokompatybilność i biodegradowalność. W związku z możliwością przeniesienia od zwierząt do organizmu człowieka choroby Creutzfelda-Jacoba (encefalopatia gąbczasta, Bovine Spongiform Encephalopathy) wzrosło zainteresowanie kolagenem pochodzącym od ryb. Badany przez nas kolagen pochodzi ze skóry tołpygi (Hypophtalmichthys molitrix), a otrzymany został metodą hydratacji w wodnym roztworze kwasu mlekowego. Wykonano topografię badanej próbki za pomocą The Dimension® Icon™ Scanning Probe Microscope (SPM), pokazując jej fibrylarną strukturę, o wymiarach odpowiadających przedstawianym w literaturze. Do badania kolagenu rybiego zastosowano spektroskopię ramanowską z użyciem spektrometru Ramascope 1000 firmy Renishaw. Źródłem wzbudzeń był laser helowo-neonowy o długości fali 633 nm. Analiza widm Ramana pozwoliła określić zawartość aminokwasów w kolagenie, w tym proliny i hydroksyproliny. Wykazała także natywność tak pozyskanego materiału w temperaturze 20 °C. Udowodniono też trwałość struktury drugorzędowej tego materiału ogrzanego do około 85 °C i schłodzonego. Zaprezentowano spektroskopię ramanowską jako skuteczną metodę badania biopolimerów.
Źródło:
Fibres & Textiles in Eastern Europe; 2018, 6 (132); 51-56
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detailed spectral monitoring of different combustible blends based on gasoline, ethanol and methanol using FT-Raman spectroscopy
Autorzy:
Ortega Clavero, V.
Weber, A.
Schröder, W.
Meyrueis, P.
Javahiraly, N.
Powiązania:
https://bibliotekanauki.pl/articles/363078.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
mieszanka palna
spektroskopia FT-Ramana
spektralna analiza chemiczna
combustible blends
FT-Raman spectroscopy
spectral chemical analysis
Opis:
The use of mixtures of oil-based fuels with organic chemical components (e.g. ethanol, methanol) has been gaining ground in recent years. Several countries try nowadays to replace part of the fossil fuels for various reasons including economics, sustainability or optimization of resources. The characteristics of these combustiblerelated chemical component blends can be analyzed by different means. Optical spectral analysis (e.g. Raman, Fourier-transforminfrared, etc.) can extract inmany casesmost of the required information concerning themolecular structure of a determined chemical sample in an effective and clean manner. Experimental detailed Raman spectra fromvarious gasoline-ethanol blends and a gasoline-ethanolmethanol blend are presented. The Raman spectral information obtained has been used for approximated quantitative analysis with no additional chemical marker or complicated calibration methods. The analysis has been performed using a self-designed, low-cost, robust and frequency precise Fourier transform Raman (FT-Raman) spectrometer. This proposed FT-Raman spectrometer has been constructed with a Michelson interferometer, an in-house designed photon counter, and a sensitive trans-impedance photo-detector. Additional complex hardware was not used to compensate the mechanical or thermal drifts disturbances in the interferometer. For accurate spectral calculation an interference pattern generated by a low-power Helium-Neon laser (wavelength λ=632.816nm)was used. The resulting spectral data are in the range of 0*cm-1 to 3500*cm-1. The resolution of these Raman spectra is 1.66*cm-1. Higher resolutions are possible since the scanning distances in the Michelson interferometer can be extended substantially before instrumental effects appear. A comparison of the experimental results obtained with standard Raman shift values revealed a satisfactory accuracy and precision in frequency detection.
Źródło:
Environmental Biotechnology; 2012, 8, 1; 1-6
1734-4964
Pojawia się w:
Environmental Biotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface Treatment And Modification Of Graphene Using Organosilane And Its Thermal Stability
Obróbka powierzchniowa i modyfikacja grafenu przy użyciu organosilanu i jego stabilność termiczna
Autorzy:
Kim, D.-S.
Dhand, V.
Rhee, K.-Y.
Park, S.-J.
Powiązania:
https://bibliotekanauki.pl/articles/354056.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
graphite
thermal properties
Raman spectroscopy
surface treatment
3-APTES
grafit
właściwości termiczne
spektroskopia Ramana
obróbka powierzchniowa
Opis:
In this study, graphene was functionalized via acid oxidation in the presence of a mixture of concentrated sulfuric acid and nitric acid. The oxidized graphene was silanized using the coupling agent, 3-aminopropyltriethoxsilane, resulting in functionalized graphene. The oxidized graphene and functionalized graphene were characterized by X-Ray diffraction, Fourier transform infrared spectroscopy, High-resolution micro Raman spectroscopy, thermogravimetric analysis, and atomic force microscopy to confirm the presence of functional moieties on the graphene surface. Thermal studies also demonstrate that the functionalized material is thermally stable up to higher temperatures.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 2B; 1387-1391
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A multi-analytical approach for the analysis of cation distribution in a aluminoceladonite structure
Autorzy:
Kądziołka-Gaweł, Mariola
Dulski, Mateusz
Czaja, Maria
Krzykawski, Tomasz
Szubka, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/2172615.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
aluminoceladonite
ions position characterization isomorphic substitutions
Fe bearing phyllosilicates
X-ray photoelectron spectroscopy
Mössbauer spectroscopy
Raman spectroscopy
glinokrzemiany
krzemiany warstwowe
rentgenowska spektrometria fotoelektronów
XPS
spektroskopia mössabuerowska
spektroskopia Ramana
Opis:
In this paper cation arrangement in two samples of aluminoceladonite, emerald green and dark-green were studied by Mössbauer, Raman and X-ray photoelectron spectroscopies. The X-ray photoelectron spectroscopy (XPS) spectra obtained in the region of the Si2p, Al2p, Fe2p, K2p, and O1s core levels provided information, for the first time highlighting a route to identify the position of Si, Al, K, and Fe cations in a structure of layered silicates. The XPS analysis showed the presence of Al in tetrahedral and octahedral coordination while the K2p line indicated the possibility of K+ substitution by other cations in interlayer sites. Mössbauer spectroscopy provided information about crystal chemistry with respect to the local electronic and geometric environment around the Fe atom and to distortions of the polyhedra. It turned out that iron was located mostly in the cis-octahedra position wherein about 75% of iron appeared in the form of Fe3+. The most preferred cation combinations around Fe corresponded to 3Fe3+ ions and MgFe2+Fe3+/2MgFe3+. Raman spectroscopy illustrated aluminium substitution in silicon and iron positions wherein the concentration of the aluminium determined the degree of structural distortion within the layered system. These isomorphic substitutions implied a typical band arrangement in the hydroxyl region, which has not been observed in celadonites so far.
Źródło:
Acta Geologica Polonica; 2022, 72, 3; 353--368
0001-5709
Pojawia się w:
Acta Geologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis of carbon nanotubes via chemical vapor deposition by using rareearth metals as catalysts
Autorzy:
Jędrzejewska, A.
Wnuk, K.
Kaleńczuk, R. J.
Borowiak-Paleń, E.
Powiązania:
https://bibliotekanauki.pl/articles/779342.pdf
Data publikacji:
2010
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
nanorurki węglowe
chemiczne osadzanie CVD
spektroskopia Ramana
transmisyjna mikroskopia elektronowa
carbon nanotubes
chemical vapor deposition (CVD)
Raman spectroscopy
transmission electron microscopy
Opis:
This work presents the results of the synthesis of carbon nanotubes using the CVD method. Fe:MgO catalyst was used, also in combination with rare earth elements (gadolinium (Gd), dysprosium (Dy)), which when used alone, are not efficient as catalysts in nanotube growth. Synthesis was performed both at reduced pressure (10-3 mbar) and atmospheric pressure, with constant parameters dependent on the process parameters.
Źródło:
Polish Journal of Chemical Technology; 2010, 12, 3; 29-32
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
First report on the occurrence of CO2-bearing fluid inclusions in the Meiduk porphyry copper deposit, Iran: implications for mineralisation processes in a continental collision setting
Autorzy:
Asadi, Sina
Moore, Farid
Zarasvandi, Alizera
Khosrojerdi, Majid
Powiązania:
https://bibliotekanauki.pl/articles/94619.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
CO2-bearing fluid inclusions
laser Raman spectroscopy
collision
Meiduk porphyry copper deposit
Iran
laserowa spektroskopia Ramana
zderzenie
złoża miedzi porfirowej
Meiduk
Opis:
Hydrothermal alteration of the Meiduk porphyry copper deposit, south of the Kerman Cenozoic magmatic arc and southeast of the central Iranian volcano-plutonic belt has resulted in three stages of mineralisation characterised by veins and veinlets. These are, from early to late: (1) quartz + K-feldspar + biotite + pyrite ± chalcopyrite ± pyrrhotite ± magnetite (early potassic alteration and type-A veins); (2) quartz + chalcopyrite + pyrite + bornite + pyrrhotite + K--feldspar + biotite + magnetite (potassic-sericitic alteration and type-B veins); and (3) quartz + pyrite + chalcopyrite +s ericite (sericitic alteration and type-C veins). Most ores were formed during stages 2 and 3. Three main types of fluid inclusions are distinguished based on petrographical, microthermometrical and laser Raman spectroscopy analyses, i.e. type I (three-phase aqueous inclusions), type II (three-phase liquid-carbonic inclusions) and type III (multi-phase solid inclusions). The fluid inclusions in quartz veins of the stages are mainly homogenised at 340-530°C (stage 1), 270-385°C (stage 2) and 214-350°C (stage 3), respectively, with salinities of 3.1-16 wt.% NaCl equivalent, 2.2-43 wt.% NaCl equivalent and 8.2-22.8 wt.% NaCl equivalent, respectively. The estimated trapping pressures are 97.9-123.6 MPa (3.7-4.6 km) in stage 1 and 62.5-86.1 MPa (2.3-3.1 km) in stage 2, respectively. These fluid inclusions are homogenised in different ways at similar temperatures, suggesting that fluid boiling took place in stages 2 and 3. The fluid system evolved from high-temperature, medium-salinity, high-pressure and CO2-rich to low-temperature, low-pressure, high-salinity and CO2-poor, with fluid boiling being the dominating mechanism, followed by input of meteoric water. CO2 escape may have been a factor in increasing activities of NaCl and S2- in the fluids, diminishing the oxidation of the fluids from stage 1 to 3. The result was precipitation of sulphides and trapping of multi-phase solid inclusions in hydrothermal quartz veins.
Źródło:
Geologos; 2013, 19, 4; 301-320
1426-8981
2080-6574
Pojawia się w:
Geologos
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected imaging techniques applied in forensic science
Wybrane techniki obrazowania stosowane w kryminalistyce
Autorzy:
Łasińska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/501727.pdf
Data publikacji:
2018-03-15
Wydawca:
Agencja Bezpieczeństwa Wewnętrznego
Tematy:
imaging techniques
microscopy
SEM
X-ray microanalysis
EDS
Raman spectroscopy
atomic force microscopy
AFM
techniki obrazowania
mikroskopia
mikroanaliza rentgenowska
spektroskopia Ramana
mikroskopia sił atomowych
Opis:
The article presents issues that include various imaging techniques used in forensics. Technology development observed in the modern world, implies changes in all areas of life, improving, speeding up and opening them to new research capabilities. The use of advanced technology allows precise analysis of the evidence. The opportunity to observe different samples at high magnification is necessary in the performance of their documentation (examination of the morphology of the surface, setting the diagnostic characteristics). The application of optical microscopy, electron microscopy or atomic force microscopy, and integrated spectroscopic systems is an essential and powerful tool for implementation observations of a variety of materials.
W artykule przedstawiono zagadnienia obejmujące różne techniki obrazowania wykorzystywane w kryminalistyce. Rozwój technologii obserwowany we współczesnym świecie pociąga za sobą zmiany we wszystkich dziedzinach życia, usprawniając, przyspieszając oraz otwierając je na nowe możliwości badawcze. Wykorzystanie zaawansowanej technologii pozwala na precyzyjną analizę materiału dowodowego. Możliwość obserwacji różnych próbek w dużych powiększeniach jest niezbędna przy wykonywaniu ich dokumentacji (badanie morfologii powierzchni, ustalanie cech diagnostycznych). Zastosowanie mikroskopii optycznej, elektronowej lub sił atomowych, a także zintegrowanych z nimi systemów spektroskopowych jest podstawowym, a zarazem potężnym narzędziem służącym wykonywaniu obserwacji różnorodnych materiałów.
Źródło:
Przegląd Bezpieczeństwa Wewnętrznego; 2018, 10, 18; 283-309
2080-1335
2720-0841
Pojawia się w:
Przegląd Bezpieczeństwa Wewnętrznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of carbon nanofibers/ ZrO2 ceramic matrix composite
Charakterystyka kompozytu o osnowie ceramicznej modyfikowanej włóknami węglowymi
Autorzy:
Duszová, A
Morgiel, J.
Bastl, Z.
Mihály, J
Dusza, J.
Powiązania:
https://bibliotekanauki.pl/articles/356257.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
carbon nanofibers
nanocomposites
transmission electron microscopy
high resolution transmission electron microscopy
Raman spectroscopy
włókna węglowe
nanokompozyty
transmisyjny mikroskop elektronowy
mikroskopia skaningowa elektronowa
spektroskopia Ramana
Opis:
Carbon micro/nanofibers prepared by catalytic chemical vapor deposition have been characterized in the form of powders and in the form of filaments, intercorporated in the matrix of ZrO2. Scanning electron microscopy, transmission electron microscopy, high resolution electron microscopy, electron spectroscopy for chemical analysis and Raman spectroscopy have been used. The outer diameter of the fibers varied from 50 nm to 600 nm with an average diameter of 120 nm, length from several micrometers to several tens of micrometers and inner diameters from 20 nm to 230 nm. Two types of fibers have been identified; cylindrical which consists of a distinct graphite layers parallel to the fiber axes and bamboo - shaped fibers with walls which are built from domains with different orientations of graphite layers. The fibers contain 99.05 at.% carbon and 0.95 at.% oxygen with a binding energy of O (1s) electrons of 532.7 e V which corresponds to carbon in C-O bonds. In the first-order Raman spectra, the position of the band G was found at 1600 cm-1 and D at 1282 cm-1. The CNFs in ZrO2+ CNFs composite have been relatively well dispersed, however clusters of CNFs together with porosity are present as a result of the difficulty of dispersing, too. TEM and HREM revealed that the CNFs are usually located at the grain boundaries of ZrO2 in the form of undamaged nanofibers or disordered graphite.
Włókna węglowe przygotowane metodą osadzania z par (tzw. Chemical Vapour Deposition), były badane bezpośrednio po wytworzeniu oraz po wprowadzeniu do osnowy ceramicznej metodami elektronowej mikroskopii skaningowej, transmisyjnej oraz spektroskopii ramanowskiej. Średnica włókien wahała się pomiędzy 50 nm, a 600 nm przy sredniej wartości ok.120 nm, podczas gdy ich długość wynosiła od kilku do kilkudziesięciu mikrometrów. Identyfikowano dwa rodzaje budowy włókien, tj. cylindryczne oraz z wewnętrznymi przekładkami typu „łodygi bambusa“. Włókna węglowe zawierały do 0.95 at. % tlenu o energi wiazania O (1s) ok.532.7 e V, co odpowiada wiązaniu C-O. Na pierwszym widmie Ramana pasmo G identyfikowano dla 1600 cm-1, a pasmo D dla 1282 cm-1. Badania kompozytu wykazałay równomierny rozkład włókien w ceramicznej osnowie. W sąsiedztwie większych aglomeratów stwierdzono tendencje do występowania pustek. W czasie spiekania przeważająca część włókien zachowała swoją rurkową strukturę, natomiast pozostały materiał węglowy uległ przemianie do słabo uprządkowanych struktur grafitu lub nawet uległ amorfizacji.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 2; 459-463
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal history of the Carboniferous strata in the northern part of the Intra-Sudetic Basin (SW Poland): A combined Raman spectroscopy and organic petrography study
Autorzy:
Botor, Dariusz
Toboła, Tomasz
Waliczek, Marta
Powiązania:
https://bibliotekanauki.pl/articles/1835585.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Raman spectroscopy
vitrinite reflectance
dispersed organic matter
coalification
Lower Silesia Coal District
Bohemian Massif
spektroskopia Ramana
refleksyjność witrynitu
rozproszona materia organiczna
uwęglenie
Dolnośląskie Zagłębie Węglowe
Masyw Czeski
Opis:
Raman spectroscopy and vitrinite reflectance measurements of dispersed organic matter from Carboniferous shales in boreholes in the northern part of the Intra-Sudetic Basin were used for thermal history reconstruction. Microscopic investigations have shown that the organic matter is dominated by the vitrinite maceral group. In analysed samples, organic matter shows a varied degree of thermal alteration determined by the mean random vitrinite reflectance (VRo) ranging from 0.72% to 3.80%. Mean apparent maximum vitrinite reflectance (R’max) values reached 4.98%. The full width at half maximum of D1 and G bands in Raman spectra are well-correlated with mean VRo and R’max. Thermal maturity in the boreholes shows a regular increase with depth. Geological data combined with Raman spectroscopy and mean vitrinite reflectance results indicate that the analysed Carboniferous strata reached maximum paleotemperatures from c. 110 to c. 265°C. The regional paleogeothermal gradient in the late Paleozoic was c. 80°C/km. The Variscan heating event presumably caused a major coalification process of organic matter. The Carboniferous–Permian magmatic activity must have contributed to high heat flow, adding to the effect of sedimentary burial on the thermal maturity.
Źródło:
Acta Geologica Polonica; 2020, 70, 3; 363--396
0001-5709
Pojawia się w:
Acta Geologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal history of the Carboniferous strata in the northern part of the Intra-Sudetic Basin (SW Poland): A combined Raman spectroscopy and organic petrography study
Autorzy:
Botor, Dariusz
Toboła, Tomasz
Waliczek, Marta
Powiązania:
https://bibliotekanauki.pl/articles/139342.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Raman spectroscopy
vitrinite reflectance
dispersed organic matter
coalification
Lower Silesia Coal District
Bohemian Massif
spektroskopia Ramana
refleksyjność witrynitu
rozproszona materia organiczna
uwęglenie
Dolnośląskie Zagłębie Węglowe
Masyw Czeski
Opis:
Raman spectroscopy and vitrinite reflectance measurements of dispersed organic matter from Carboniferous shales in boreholes in the northern part of the Intra-Sudetic Basin were used for thermal history reconstruction. Microscopic investigations have shown that the organic matter is dominated by the vitrinite maceral group. In analysed samples, organic matter shows a varied degree of thermal alteration determined by the mean random vitrinite reflectance (VRo) ranging from 0.72% to 3.80%. Mean apparent maximum vitrinite reflectance (R’max) values reached 4.98%. The full width at half maximum of D1 and G bands in Raman spectra are well-correlated with mean VRo and R’max. Thermal maturity in the boreholes shows a regular increase with depth. Geological data combined with Raman spectroscopy and mean vitrinite reflectance results indicate that the analysed Carboniferous strata reached maximum paleotemperatures from c. 110 to c. 265°C. The regional paleogeothermal gradient in the late Paleozoic was c. 80°C/km. The Variscan heating event presumably caused a major coalification process of organic matter. The Carboniferous–Permian magmatic activity must have contributed to high heat flow, adding to the effect of sedimentary burial on the thermal maturity.
Źródło:
Acta Geologica Polonica; 2020, 70, 3; 363-396
0001-5709
Pojawia się w:
Acta Geologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies