Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Panel fotowoltaiczny" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Economy and energy analysis in the operation of renewable energy installations – a case study
Autorzy:
Idzikowski, Adam
Cierlicki, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1839542.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
panel fotowoltaiczny
odnawialne źródła energii
falownik
solar panel
renewable sources of energy
inverter
Opis:
In the paper an economic, ecological and energy analysis of a home photovoltaic on grid installation was presented. The increase in ecological awareness of the Polish society contributes to the continuous growth of interest in green energy. However, many people haven’t been aware of the ecological, economic and energy benefits of photovoltaic installations yet, so the following analysis is made. The analysis concerns a photovoltaic installation with a capacity of 3.96 kWp located in Ościęciny near Włocławek. The photovoltaic installation consists of 11 monocrystalline panels with a power of 360 Wp, a 4 KTLM Sofar Solar inverter and other necessary components. The first part presents basic issues related to photovoltaic installations. Parameters related to the proper functioning of the photovoltaic installation were replaced. The analysis of the literature will help to understand the essence of the proper functioning of the photovoltaic installation. In the practical part, an analysis of a selected home photovoltaic installation was carried out. Based on the available data, it has been calculated that the installation will have a payback period of over 9 years. The photovoltaic installation will produce approximately 3 582.61 kWh of electricity and will contribute to the reduction of 70 tons of carbon dioxide during the entire operation.
Źródło:
Production Engineering Archives; 2021, 27, 2; 90-99
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vacuum circuit breaker switching in medium voltage networks with photovoltaic panels at low voltage side working as a supply source
Operacje łączeniowe wyłącznikiem próżniowym w sieciach średniego napięcia z uwzględnieniem paneli fotowoltaicznych pracujących po stronie niskiego napięcia jako źródło zasilania
Autorzy:
Kuczek, T.
Florkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/268833.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
panel fotowoltaiczny
wyłącznik próżniowy
przepięcia
PV cell
vacuum circuit breaker
overvoltage
Opis:
Breaking of inductive currents with use of vacuum circuit breaker is related to a problem of current chopping before its natural zero crossing. Due to the energy trapped in oscillatory circuit consisting of transformer's inductance and capacitance, the voltage across circuit breaker contacts starts to oscillate. Breaking of dielectric withstand can lead to multiple arc re-ignitions, which can result in generation of waveforms with high steepness and overvoltage peak values. In the present article, the principle of those phenomena was explained. Simulation results of circuit breakers opening operation in medium voltage network consisting of transformer with photovoltaic panels connected at low voltage side was also presented.
Wyłączniki próżniowe stosowane w elektroenergetyce średnich napięć charakteryzują się efektem tzw. ucięcia prądu przed jego naturalnym przejściem przez zero. Z powodu energii zmagazynowanej w indukcyjności oraz pojemności transformatora, podczas operacji otwierania napięcie powrotne pomiędzy zaciskami wyłącznika zaczyna oscylować. W momencie przekroczenia wytrzymałości dielektrycznej pomiędzy zaciskami, następuje ponowny zapłon łuku elektrycznego. Zjawisko to może doprowadzić to powstania przepięć o wysokiej stromości oraz wartościach szczytowych. W pracy zaprezentowano wyniki symulacji procesu otwierania wyłącznika próżniowego w sieci z transformatorem zasilanym ze strony niskiego napięcia poprzez panele fotowoltaiczne.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 85-88
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Green energy from a hybrid PV panels and wind turbine farm in Lebanon
Autorzy:
Nesser, Bassel I.
Soliman, Mohamed Hassan
Pytel, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2064369.pdf
Data publikacji:
2019
Wydawca:
STE GROUP
Tematy:
vertical axis wind turbine
PV panel
carbon dioxide
panel fotowoltaiczny
dwutlenek węgla
turbina wiatrowa o pionowej osi
Opis:
The publication presents the results of analysis of green energy from a hybrid PV panels and wind turbine farm use in Lebanon. Electricity is one of the most critical problems in Lebanon. This publication presents an effective solution to this issue. It deals with the generation of green environment friendly electricity from photovoltaic (PV) panels and wind turbine. The genuine idea consists of placing these panels and turbines at the middle of the coastal highway since it is considered as a free land. The produced energy is fed directly to the off gird after being inverted using appropriate devices. The middle of the highway from Tyre to Sidon is considered to apply this research. The actual design consists of 15222 PV panels placed in pairs on a steel chassis among the entire 27300 m coastal distance, 2 meters wide and 7610 vertical axis wind turbines placed at a distance of 0.9 m away from each pair of PV panels. The total energy produced by the PV system is estimated to 7.4 GWh/y and 3.1 GWh/y at an average wind velocity of 4.04 m/s. In addition to its benefit from a free land, the produced energy is environment friendly since there is no carbon dioxide emission.
Źródło:
New Trends in Production Engineering; 2019, 2, 1; 541--548
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of a mathematical model of the thin-film photovoltaic panel (CIS) based on measurement data
Wyznaczanie modelu matematycznego cienkowarstwowego panelu fotowoltaicznego (CIS) na podstawie danych pomiarowych
Autorzy:
Trzmiel, G.
Powiązania:
https://bibliotekanauki.pl/articles/301199.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
photovoltaic panel
CIS solar cells
approximation
mathematical model
statistical verification
panel fotowoltaiczny
ogniwa słoneczne CIS
aproksymacja
model matematyczny
weryfikacja
Opis:
In this paper the author attempted to determine the most accurate mathematical model of the photovoltaic panel composed of a monolithic structure of series connected Copper Indium Diselenide (CIS) based solar cells, based on its actual measurement data. The purpose of this paper has been achieved by implementing the original applications which, using the methods of approximation, made it possible to design the final mathematical model of the tested panel, characterized by the minimum of error modelling. Using the known literature on the operation of similar facilities, the model parameters were determined directly from the collection of random measurement data; then the obtained models were verified by several different statistical methods. As a result, the best model was selected, based on the smallest dispersion of the theoretical values (simulated) calculated from the model relative to the actual measurements. The model will be used in practice in the future to evaluate the condition (inefficiency, use) of photovoltaic panels, what will be the theme of following articles.
W artykule autor dąży do określenia, w oparciu o rzeczywiste dane pomiarowe, najbardziej dokładnego modelu matematycznego panelu fotowoltaicznego, składającego się z monolitycznej struktury połączonych szeregowo ogniw fotowoltaicznych typu CIS. Cel pracy został osiągnięty poprzez wdrożenie oryginalnych aplikacji, które przy użyciu metod aproksymacji umożliwiły zaprojektowanie ostatecznego modelu matematycznego badanego panelu, charakteryzującego się minimalnym błędem modelowania. Wykorzystując literaturę tematu dotyczącą działania podobnych obiektów nieliniowych, parametry modelu zostały określone bezpośrednio z wcześniej zarchiwizowanych losowych danych pomiarowych. Następnie uzyskane modele zweryfikowano kilkoma różnymi metodami statystycznymi. W wyniku tego wybrano najlepszy model, oparty na najmniejszej dyspersji wartości teoretycznych (symulowanych) obliczonej z modelu w stosunku do rzeczywistych pomiarów. Otrzymany model zostanie w przyszłości zastosowany w praktyce do oceny stanu (niesprawności, zużycia) paneli fotowoltaicznych, co będzie tematem kolejnych artykułów.
Źródło:
Eksploatacja i Niezawodność; 2017, 19, 4; 516-521
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The ecological impact of using photothermal and photovoltaic installations for DHW preparation
Ekologiczny wpływ zastosowania instalacji footermicznej i fotowoltaicznej do przygotowania ciepłej wody użytkowej
Autorzy:
Olczak, Piotr
Olek, Małgorzata
Kryzia, Dominik
Powiązania:
https://bibliotekanauki.pl/articles/282886.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
photovoltaic panel
reduction of CO2 emission
evacuated tube collector with heat pipe
panel fotowoltaiczny
redukcja emisji CO2
próżniowy kolektor rurowy typu heat pipe
Opis:
A domestic hot water (DHW) system has been modernized in a multi-family house, located in the southeastern part of Poland, inhabited by 105 people. The existing heating system (2 gas boilers) was extended by a solar system consisting of 32 evacuated tube collectors with a heat pipe (the absorber area: 38.72 m2). On the basis of the system performance data, the ecological effect of the modernization, expressed in avoided CO2 emission, was estimated. The use of the solar thermal system allows CO2 emissions to be reduced up to 4.4 Mg annually. When analyzing the environmental effects of the application of the solar system, the production cycle of the most material-consuming components, namely: DHW storage tank and solar collectors, was taken into account. To further reduce CO2 emission, a photovoltaic installation (PV), supplying electric power to the pump-control system of the solar thermal system has been proposed. In the Matlab computing environment, based on the solar installation measurement data and the data of the total radiation intensity measurement, the area of photovoltaic panels and battery capacity has been optimized. It has been shown that the photovoltaic panel of approx. 1.8 m2 and 12 V battery capacity of approx. 21 Ah gives the greatest ecological effects in the form of the lowest CO2 emission. If a photovoltaic system was added it could reduce emissions by up to an additional 160 kg per year. The above calculations take also emissions resulting from the production of PV panels and batteries into account.
W budynku wielorodzinnym położonym w południowo-wschodniej części Polski, zamieszkałym przez 105 osób, zmodernizowano system przygotowania ciepłej wody użytkowej. Istniejący system grzewczy (2 kotły gazowe) został rozbudowany o układ kolektorów słonecznych składający się z 32 próżniowych kolektorów rurowych (powierzchnia absorbera wynosi 38,72 m2). Na podstawie danych o wydajności systemu oszacowano ekologiczny efekt modernizacji, wyrażony jako uniknięta emisja CO2. Zastosowanie systemu kolektorów słonecznych pozwala zmniejszyć emisję CO2 do 4,4 Mg rocznie. Analizując skutki środowiskowe zastosowania instalacji kolektorów słonecznych, wzięto pod uwagę cykl produkcyjny najbardziej materiałochłonnych komponentów instalacji, a mianowicie zasobnika ciepłej wody użytkowej i kolektorów słonecznych. Aby jeszcze bardziej ograniczyć emisję CO2, zaproponowano instalację fotowoltaiczną, dostarczającą energię elektryczną do napędu pompy obiegowej instalacji kolektorów słonecznych. W środowisku obliczeniowym Matlab, na podstawie danych pomiarowych z instalacji kolektorów słonecznych i danych pomiarowych całkowitego natężenia promieniowania, zoptymalizowano powierzchnię paneli fotowoltaicznych i pojemność akumulatorów. Wykazano, że układ paneli fotowoltaicznych o powierzchni ok. 1,8 m2 oraz akumulatorów 12 V o pojemności ok. 21 Ah zapewnia największy efekt ekologiczny w postaci najniższej emisji CO2. Dodanie paneli fotowoltaicznych może zmniejszyć roczną emisję CO2 nawet o dodatkowe 160 kg. Powyższe obliczenia uwzględniają również emisje wynikające z tytułu produkcji paneli fotowoltaicznych i akumulatorów.
Źródło:
Polityka Energetyczna; 2020, 23, 1; 65-74
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies