Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "3DSSPP" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Assessment of load on the lumbar spine using two computerised packages and REBA method
Autorzy:
Tokarski, Maciej
Roman-Liu, Danuta
Powiązania:
https://bibliotekanauki.pl/articles/27324124.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
risk assessment
lower back
comparison of assessment procedures
3DSSPP
ShiftBack
ocena ryzyka
dolna część pleców
porównanie procedur oceny
Opis:
Purpose: The aim of the research was a comparative analysis of the back lumbar load assessment using three methods: two with continuous input data and evaluation procedures based on mathematical relationships (ShiftBack, 3DSSPP) and one method with categorized input data and tabular load estimation procedures (REBA). Methods: For the analysis, work activities and the value of applied force were selected. Among the analyzed 24 work activities were those during which there was a symmetrical load, as well as those during which the applied force or the assumed position of the body caused a lack of load symmetry. Results: The results show that the REBA method differentiates 24 cases of unit load into six levels, while the other two methods provide 24 different values between cases. Cases differing in load even over 100%, when assessed according to the 3DSSPP or ShiftBack do not differ in the assessment of REBA. Differences in the assessment of the same tasks between the results obtained from 3DSSPP and ShiftBack that were above 15% concern only 7 cases. Conclusions: A comparative analysis of the assessment of the lumbar part of the back using three methods indicates strong correlations between the results of the assessment carried out using 3DSSPP and ShiftBack. Smaller relationships were demonstrated by comparing these two methods with the REBA method.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 3; 43--53
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies