Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zmarzły, M." wg kryterium: Autor


Wyświetlanie 1-6 z 6
Tytuł:
The influence of ultrasound signal parameters on sonoluminescence light intensity
Autorzy:
Szmechta, M.
Boczar, T.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/140426.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
diagnostics of insulating oils
sonoluminescence phenomenon
acoustic cavitation
ultrasound signal
acoustic emission Signac
Opis:
Topics of this article concern the study of the fundamental nature of the sonoluminescence phenomenon occurring in liquids. At the Institute of Electrical Power Engineering at Opole University of Technology the interest in that phenomenon known as secondary phenomenon of cavitation caused by ultrasound became the genesis of a research project concerning acoustic cavitation in mineral insulation oils in which a number of additional experiments performed in the laboratory aimed to determine the influence of a number of acoustic parameters on the process of the studied phenomenona. The main purpose of scientific research subject undertaken was to determine the relationship between the generation of partial discharges in high-voltage power transformer insulation systems, the issue of gas bubbles in transformer oils and the generated acoustic emission signals. It should be noted that currently in the standard approach, the phenomenon of generation of acoustic waves accompanying the occurrence of partial discharges is generally treated as a secondary phenomenon, but it can also be a source of many other related phenomena. Based on our review of the literature data on those referred subjects taken, it must be noted, that this problem has not been clearly resolved, and the description of the relationship between these phenomena is still an open question. This study doesn’t prove all in line with the objective of the study, but can be an inspiration for new research project in the future in this topic. Solution of this problem could be a step forward in the diagnostics of insulation systems for electrical Power devices based on non-invasive acoustic emission method.
Źródło:
Archives of Electrical Engineering; 2013, 62, 4; 605-612
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proces kalibracji głowic pomiarowych dla systemu pomiaru sił wykorzystywanego podczas montażu kotła energetycznego 1100MW
Calibration process of measurement units for the force sensor system used during 1100MW power boiler erection procedure
Autorzy:
Bialic, G.
Zmarzły, M.
Szmechta, M.
Stanisławski, R.
Powiązania:
https://bibliotekanauki.pl/articles/151677.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kalibracja
pomiar sił
metoda najmniejszych kwadratów
calibration
force measurement
least square method
Opis:
Zaproponowane zastosowanie pomiarów elektronicznych oraz systemu komputerowego podczas montażu konstrukcji kotła energetycznego ma na celu zwiększenie poziomu bezpieczeństwa procesu montażowego. System FSS (Force Sensor System) monitorujący siły działające na stalowe cięgna podczas procedury tymczasowego wciągania "bandaży" daje możliwość weryfikacji obliczeń projektowych dla technologii montażu kotła. Dane zgromadzone przez system pozwolą w przyszłości na uniknięcie ewentualnych błędów, które mogą pojawić się w fazie projektowej. Dla zapewnienia wysokiej precyzji pomiaru wartości sił kalibrowane zostały kompletne głowice pomiarowe. Specjalnie w tym celu zaprojektowano, wykonano i przetestowano komputerowy system kalibrujący. System ten współpracuje z prasą hydrauliczną, posiadającą aktualną legalizację. Przeprowadzone badania systemu wykazały poprawność proponowanych rozwiązań technicznych a dokładność kalibracji spełnia postawione wymagania technologiczne.
The main goal of using electronic measurements and a computer system during the power boiler erection is to ensure the highest process safety level. The FSS (Force Sensor System) applied to force monitoring allows designers to verify the computations carried out for the technology of the power boiler erection. The data acquisited by FSS will let designers avoid eventual faults in the future. In order to ensure the high precision of measurements, the authors decided that complete measurement units should be calibrated. For that purpose a special automatic calibration system for FSS measurement units was designed and realised. This system cooperates with a legalised hydraulic press. Numerous tests proved that the proposed solution is correct and the accuracy of calibration meets the technological requirements. The computer system (Fig. 1) of automatic calibration consists of: 1) a legalised hydraulic press of the range 1000 kN,a measurement interface of instant force values with a high precision linear displacement sensor (Fig. 3) and a communication unit; these components determine the system master value, 2) a computer system supervising the calibration process. This computer unit displays instantaneous master and slave values of the force, calculate and update the calibration parameters of an amplifier. The calibration system for FSS modules is characterized by the linear relation between the voltage across the strain gauge bridge of the range 0-15mV and the master value obtained from the press. For that reason the estimation of the measured value using a linear function was suggested (1). The automation of the calibration process is obtained as a result of the following procedure: a) sampling the master and measured values in discrete time instants with the frequency of 1Hz, b) the calibration time should be within the range of 1-2 min, c) determining the value of b parameter - corresponding to zero force, d) data selection for the estimation algorithm resulting from technological limits, e) determining the slope of the straight line factor a by means of the least square algorithm.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 2, 2; 114-116
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling and optimization of the force sensor network
Autorzy:
Bialic, G.
Zmarzły, M.
Stanisławski, R.
Powiązania:
https://bibliotekanauki.pl/articles/384391.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
sensor network optimization
mathematical modeling
Opis:
The power boiler erection process requires temporary suspending of buckstays (Fig. 1). The aim of buckstays installation is to brace screens of combustion chamber. Suspending of buckstays is performed by means of strand jacks and steel rods. The amount, location and force ranges of each rods are modelled on the basis of static structural strength computations. In the paper the force sensor network incorporated into computer and wireless communication system designed to prevent overloading of the rods resulting from force asymmetry or computational faults is introduced and next subjected to optimization procedure. The operational data delivered by the network and recorded on the system hard drives let the authors perform the correlation analysis and linear regression to reduce the number of sensors. Thus two stage hierarchic algorithm which constructs the set of models for every single sensor and estimates their parameters, and then using genetic procedure minimizes a certain loss function to automate the sensor network optimization process is introduced. As a result, such investigation could significantly reduce cost of the whole system.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 3; 55-59
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement uncertainty of acoustic emission spectra in cavitating mineral insulating oil
Niepewność pomiaru widm emisji akustycznej podczas kawitacji w mineralnym oleju izolacyjnym
Autorzy:
Szmechta, M.
Zmarzły, D.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/151460.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
analiza widmowa
kawitacja akustyczna
mineralny olej izolacyjny
emisja akustyczna
spectral analysis
acoustic cavitation
mineral insulating oil
acoustic emission
Opis:
The paper presents the research results on acoustic emission signal observed during acoustic cavitation in fresh insulating oil sample. The paper introduces a method of evaluation of measurement uncertainty of acoustic emission spectra by the statistical analysis of series of observations. The drawn probability density functions of used cavitation intensity factor values at different generated source signal parameters show the differences of its uncertainty.
W artykule przedstawiono wyniki pomiarów sygnału emisji akustycznej obserwowanej podczas kawitacji akustycznej w próbce czystego oleju izolacyjnego. Artykuł przybliża przede wszystkim metodę wyznaczania niepewności pomiaru widm emisji akustycznej poprzez analizę statystyczną serii pomiarów. Badania emisji akustycznej dokonano przy wzajemnych kombinacjach następujących wartości skutecznych sygnału: 200 V, 400 V, 600 V, 800 V, 1000 V, 1100 V; oraz jego częstotliwości: 100 kHz, 105 kHz, 110 kHz, 115 kHz. Wykreślone funkcje gęstości prawdopodobieństwa proponowanego wskaźnika intensywności kawitacji przy różnych parametrach źródłowego sygnału pokazują zaobserwowane różnice niepewności pomiaru. Wybór odpowiedniego punktu pracy układu do generacji kawitacji akustycznej pozwala na znaczne ograniczenie niepewności wyznaczania wartości przyjętego wskaźnika intensywności kawitacji poprzez minimalizację wpływu rezonansu naczynia kawitacyjnego.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 2, 2; 146-149
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of acoustic emission generated by cavitation in insulating oils
Badanie emisji akustycznej generowanej zjawiskiem kawitacji w olejach izolacyjnych
Autorzy:
Zmarzły, D.
Szmechta, M.
Powiązania:
https://bibliotekanauki.pl/articles/151184.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
emisja akustyczna
oleje izolacyjne
kawitacja
acoustic emission
insulating oils
cavitation
Opis:
The main aim of this article is the investigation of acoustic emission signals generated by acoustically induced cavitation in oils. The possibility of using the cavitation phenomenon as a principle of a diagnostic tool for monitoring the condition of insulating oils in power transformers is proposed. In this note, the principles of the measurements method are explained, the built and used experimental apparatus is described and representative results of the experimental data taken from the apparatus are shown. The experimental results are presented in form of power spectral densities of acquired acoustic emission signals. An attempt to approximate the relationship between the power spectral density and the oxidation time of the mineral oil according to the PN-EN 61125 norm was executed.
Podstawą niniejszego artykułu jest badanie sygnałów emisji akustycznej generowanych podczas zjawiska wymuszonej kawitacji akustycznej w olejach. Zaproponowano możliwość wykorzystania zjawiska do diagnostyki właściwości starzeniowych olejów izolacyjnych. Przedstawiono schemat wykorzystywanego układu pomiarowego oraz uzyskane wyniki w postaci widm gęstości mocy sygnału emisji akustycznej dla różnych wartości amplitud sygnału źródłowego. Ponadto dokonano aproksymacji zależności gęstości widmowej mocy wybranych wartości częstotliwości sygnału w funkcji czasu starzenia mineralnego oleju izolacyjnego.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 2, 2; 64-66
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic Spectra of Ultrasound Induced Cavitations in Insulating Oils
Autorzy:
Szmechta, M.
Zmarzły, D.
Boczar, T.
Lorenc, M.
Powiązania:
https://bibliotekanauki.pl/articles/1811563.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.35.Ei
43.40.Le
Opis:
Acoustic emission measurement results of acoustically induced cavitation bubbles in insulating oil are presented in this paper. Spectral analysis of acquired by a broadband transducer acoustic emission signals is proposed as a diagnostic tool for estimation of aging properties of mineral insulating oils. The article describes the main parts of the designed and built measurement apparatus used for acoustic cavitation investigation in insulating oils. In this note representative results of the experimental data taken from the apparatus are shown.
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-231-A-238
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies