Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wojtkowski, W." wg kryterium: Autor


Wyświetlanie 1-10 z 10
Tytuł:
Power semiconductor devices temperature monitoring system
System monitorowania temperatury półprzewodnikowych przyrządów mocy
Autorzy:
Wojtkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/266661.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
digital temperature sensor
temperature measurement
1-Wire bus
semiconductor power devices
cyfrowe czujniki temperatury
pomiary temperatury
magistrala 1-Wire
półprzewodnikowe przyrządy mocy
Opis:
The temperature measurement system, for parallel monitoring of temperatures of the power semiconductors devices in power converters is presented in the paper. The system was implemented in a power electronics converter for rapid recognition of the power losses level generated by individual power components. This information is important when evaluating system efficiency, current flow symmetry, and allowable output power in a given inverter configuration. The proposed system utilizes parallel multi-channel temperature measurements with digital temperature sensors operating on separate serial 1-Wire buses. FPGA device collects data from the temperature sensors and sends them through wireless interface to a PC terminal. The structure of the system as well as particular devices are described in the paper. Selected results of experimental investigations which show proper operation of the system are presented as well.
W artykule przedstawiono system równoległego pomiaru temperatury półprzewodnikowych przyrządów mocy w przekształtnikach energoelektronicznych. Prezentowany system jest użyteczny podczas badania laboratoryjnego nowych topologii przekształtników energoelektronicznych. System ten umożliwia szybkie wykrycie nadmiernego nagrzewania jednego z monitorowanych przyrządów półprzewodnikowych i jednocześnie może automatycznie włączyć sygnał dźwiękowy oraz przesłać informację do sterownika przekształtnika. Otrzymywana informacja związana z poziomem strat mocy wydzielanej w poszczególnych monitorowanych elementach jest cenna przy badaniu sprawności układu, symetrii rozpływu prądów oraz przy badaniu dopuszczalnej mocy wyjściowej przekształtnika w danej konfiguracji. Cyfrowe czujniki temperatury wyposażone w interfejs szeregowy 1-Wire komunikują się z procesorem nadzorującym w sposób sekwencyjny. Przy większej liczbie czujników czas skanowania wszystkich wartości jest nadmiernie wydłużony. W prezentowanym rozwiązaniu zastosowano oddzielne magistrale szeregowe dla każdego czujnika. W związku z tym czas pełnego odczytu nie zależy od liczby czujników. Aby to było możliwe, wykorzystano układ FPGA z zaimplementowanymi interfejsami 1-Wire. Prezentowany system ułatwia wykrywanie wielu nieprawidłowości występujących w badanym przekształtniku i w przebiegach sterujących, gdyż większość z nich wiąże się z nadmiernym nagrzewaniem zagrożonego przyrządu mocy.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 54; 233-236
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remote monitoring of semiconductor switches’ temperatures in a bidirectional DC / AC / DC converter
System zdalnego monitorowania temperatur tranzystorów przekształtnika DC / AC / DC
Autorzy:
Wojtkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/267354.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
digital temperature sensors
temperature monitoring system
1-Wire bus
node-RED
cyfrowe czujniki temperatury
system monitorowania temperatury
magistrala 1-Wire
Node-RED
Opis:
The paper presents a temperature monitoring system of a bidirectional DC / AC / DC converter. The system allows for remote monitoring of two temperatures (the number can be increased if necessary). The monitoring console is available on any mobile or stationary device connected to the local Wi-Fi network or to the Internet (if it has a static IP). By implementing the remote monitoring, important temperatures of working converter can be monitored from any place with the Internet access. The presented solution may be used in laboratories developing new topologies of power converters that should be monitored for a long time before practical implementation.
W artykule przedstawiono system zdalnego monitorowania temperatur półprzewodnikowych przyrządów mocy w przekształtniku DC / AC / DC. Prezentowany system pozwala na monitorowanie dwóch temperatur, jednak liczbę czujników oraz aktuatorów można znacznie rozszerzyć w razie potrzeby. Aktualnie monitorowane są dwie temperatury radiatorów górnego i dolnego mostka przekształtnika DC /AC /DC. Proponowane rozwiązanie bazuje na cyfrowych czujnikach temperatury DS18B20. Są one podłączone poprzez magistralę 1-Wire z jednopłytkowym mikrokomputerem Raspberry Pi w wersji 3. Interfejs 1-Wire oraz interfejs użytkownika umożliwiający monitorowanie temperatur zostały zaprojektowane w środowisku Node-RED. Konsola użytkownika jest dostępna na każdym urządzeniu podłączonym do lokalnej sieci Wi-Fi. Jeśli zastosowane Raspberry Pi posiada stały adres IP dostęp do konsoli jest możliwy z sieci Internet. Proponowane rozwiązanie może być przydatne przy projektowaniu i badaniu nowych konfiguracji i topologii pracy przekształtników energoelektronicznych, które powinny być testowane przez długi czas w laboratorium zanim znajdą zastosowanie komercyjne. System umożliwia przesyłanie sygnałów do przekształtnika czyli zdalne ustawienia.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 59; 207-210
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parallel temperature measurement system for electric vehicle
Równoległy pomiar temperatury akumulatorów w pojazdach elektrycznych
Autorzy:
Wojtkowski, W.
Lewczuk, R.
Powiązania:
https://bibliotekanauki.pl/articles/269025.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
Digital temperature sensor
temperature measurement
CAN bus
1-Wire bus
cyfrowy czujnik temperatury
pomiary temperatury
CAN
1-Wire
Opis:
A parallel temperature measurement system for monitoring a battery stack in an electric vehicle is presented in the paper. The proposed system utilizes parallel multi-channel temperature measurements with digital temperature sensors operating on separate serial buses. An FPGA device collects data from sensors and translates it into CAN bus frames. The CAN bus is incorporated for communication with car Battery Management System. The described system can parallel measure 8 temperatures but it can be extended in case of additional needs. The structure of the system as well as particular devices are described in the paper. Selected results of experimental investigations which show proper operation of the system are presented as well.
W artykule przedstawiono system równoległego pomiaru temperatury zestawu akumulatorów stosowanego w pojazdach elektrycznych EV lub hybrydowych HEV. Podczas ładowania lub rozładowywania akumulatorów Li-ion, może dochodzić do nadmiernego nagrzewania a nawet do pożaru. Aby tego uniknąć stosuje się układy nadzorowania akumulatorów pełniące także funkcje balansowania ładunku. Takie układy potrzebują do działania informacji o temperaturze zewnątrznej poszczególnych akumulatorów. Cyfrowe czujniki temperatury wyposażone w interfejs szeregowy komunikują się z procesorem nadzorującym w sposób sekwencyjny. Przy większej liczbie czujników czas odczytu wszystkich wartości jest nadmiernie wydłużony. W prezentowanym rozwiązaniu zastosowano oddzielne magistrale szeregowe dla każdego czujnika. W związku z tym czas pełnego odczytu nie zależy od liczby czujników. Aby to było możliwe, wykorzystano układ FPGA z zaimplementowanymi interfejsami 1-Wire. Całość jest kontrolowana przez procesor programowy NIOS, który dodatkowo zapewnia komunikację z systemami pojazdu przez magistralę CAN. W artykule przedstawiono strukturę proponowanego systemu oraz zostały przedstawione wybrane wyniki badań laboratoryjnych.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 54; 237-240
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of the influence of blast wave on human body
Autorzy:
Sławiński, G.
Niezgoda, T.
Barnat, W.
Wojtkowski, M
Powiązania:
https://bibliotekanauki.pl/articles/244503.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
improvised explosive devices
blast wave
survivability
numerical study
Opis:
Threats for military personnel during combat missions nowadays are of different sources. Further development of methods for neutralization of mines or improvised explosive devices (IED) explosions must be preceded by identification of the impact phenomenon on crew of the military vehicle. Large accelerations cause injury to a person located in the interior of the vehicle and may lead to permanent disability exempting soldiers from the battlefield. Information about overload coming from the explosion of IEDs on humans are difficult to access or not sufficiently detailed. Therefore, the basis for their acquisition is conducting experimental research and modelling. The paper is presents finite element analysis of blast wave effects on a human body simulated by a numerical 50th percentile HYBRID III dummy. Coupled Euler and Lagrange (ALE) formulations are used in the finite element analysis of such problems to accurately represent the detonation phenomenon. Numerical model was developed in LS-PrePost software. All the computational analyses were carried out using an explicit LS-DYNA solver on multiprocessor cluster. Data such as hip and knee moment of inertia, femoral force, and foot acceleration are collected from the numerical dummy, which simulates the occupant’s response. These data are then compared to injury threshold values from various references to assess survivability
Źródło:
Journal of KONES; 2013, 20, 3; 381-386
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of short moderate exercise on hematological parameters and stem cells in healthy humans
Autorzy:
Sochoń, K.
Sienkiewicz, D.
Okurowska-Zawada, B.
Paszko-Patej, G.
Wojtkowski, J.
Dmitruk, E.
Żak, J
Kułak, W.
Powiązania:
https://bibliotekanauki.pl/articles/1918279.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Exercise
healthy subjects
stem cells
Opis:
Introduction: Exercise at various durations and intensities impact on blood and stem cells. This pilot study examined the effects of 30 minutes of treadmill walking on hematological indices and progenitor stem cells CD34+ in healthy subjects. Materials and methods: A total of 17 non-smoking, healthy students, aged 20 to 22 years participated. Hemoglobin, hematocrit, white blood cells, platelets, and stem cell CD34+ numbers were assessed before and after moderate exercise. Statistical analyses examined the relationships between CD34+ cells versus hematological indices, age, and body mass index. Results: Following exercise, significant increases were observed in leukocytes, neutrophils, eosinophils, and CD34+ cells numbers. For CD34+ cells, a fourfold increase was seen. Significant correlations between CD34+ cells, white blood cells, and neutrophils were found. Conclusion: Our results suggest that moderate exercise has a physiological impact on hematologic parameters and stem cells CD34+ in healthy subjects. Furthermore, our findings suggest that brief treadmill exercise may enhance tissue repair mechanisms so important in physiotherapy.
Źródło:
Progress in Health Sciences; 2016, 6(2); 184-187
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Safety and efficacy of granulocyte colony stimulating factor in a patient with tetraplegia caused by cervical hyperextension injury: a case report
Autorzy:
Okurowska-Zawada, B
Kułak, W
Sienkiewicz, D
Paszko-Patej, G
Dmitruk, E
Kalinowska, A
Wojtkowski, J
Korzeniecka–Kozerska, A
Powiązania:
https://bibliotekanauki.pl/articles/1916580.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Cervical hyperextesniosn
spinal cord injury
tetraplegia
male
Opis:
he authors present the case of a 17-year-old boy who suffered a cervical spinal injury as a result of the sharp bending of the head after slipping (without falling). After about 30 minutes, he began to feel tingling in the limbs and he developed tetraparesis. He went through physical rehabili-tation, psychological rehabilitation, occupational therapy, and periodic catheterization. Additionally, we introduced to him a low dose of analog granulocyte colony-stimulating factor (G-CSF). G-CSF 5 μg/kg was given subcutaneously daily for 5 days per month for 3 months, again after 6 months, and again after 10 months. The boy could sit indecently and walk with assistance. A significant increase in muscle strength in this patient with tetraplegia after 10 months of treatment may indicate beneficial effects of G-CSF in this disorder.
Źródło:
Progress in Health Sciences; 2014, 4, 2; 181-184
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of granulocyte colony-stimulating factor therapy for osteogenesis imperfecta: a case report
Autorzy:
Paszko-Patej, G.
Sienkiewicz, D.
Kułak, W.
Okurowska-Zawada, B.
Wojtkowski, J.
Kalinowska, A.
Okulczyk, K.
Sochoń, K.
Dmitruk, E.
Mirska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1918408.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Osteogenesis imperfecta
granulocyte colony-stimulating factor
muscle strength
Opis:
Introduction: Osteogenesis imperfecta (OI) is a genetic disorder of increased bone fragility and low bone mass. OI type IV. Materials and methods: We examined the safety and effectiveness of a low dose of analog granulocyte colony-stimulating factor (G-CSF) in a 15-year-old girl OI type IV. G-CSF 5 μg/kg was given subcutaneously, for 5 days/month for 3, 6 and 12 months. Laboratory tests, including blood, biochemical tests were performed, in addition to clinical examination.Results: Clinical examination revealed an increase of muscle strength in the upper and lower limbs between base line and day 6 and 12 months. We found no serious adverse events. Leukocyte levels remained below 38,000/μL. Low dose G-CSF was safe and well tolerated by the patient. Conclusions: A significant increase in muscle strength in this patient may indicate beneficial effects of G-CSF factor in this disorder. These results are inspiring and warrant further studies.
Źródło:
Progress in Health Sciences; 2017, 7(1); 205-208
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of granulocyte colony-stimulating factor treatment in children and patients with cerebral palsy: a preliminary report
Autorzy:
Paszko-Patej, G.
Kułak, W.
Okurowska-Zawada, B.
Sienkiewicz, D.
Wojtkowski, J.
Sochoń, K.
Kalinowska, A.
Okulczyk, K.
Topór, E.
Mirska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1918403.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Granulocyte colony-stimulating factor
children
cerebral palsy
Opis:
Introduction: Recent reports have revealed that neuroinflammation and apoptosis in brains affected by cerebral palsy could be therapeutic targets. Granulocyte colony-stimulating factor (G-CSF) exerts anti-inflammatory and antiapoptosis effects and stimulates the proliferation of neural stem and progenitor cells in the brain. Purpose: To assess the efficacy and safety of G-CSF treatment in children and adolescents with CP. Materials and methods: Six patients with spastic tetraplegia CP aged 3-15 years were enrolled in this study. Five patients had GMFCS (Gross Motor Function Classification System) level at V, three children had epilepsy, and three had severe mental retardation. We used the gross motor function measure-66 (GMFM-66) to assess motor function.GCSF (5μg/kg/body/day) was administered subcutaneously for five consecutive days during the four months. The parents also evaluated the physical and mental development of their children. Results: We observed improvement in motor function in patients with CP on the GMFM-66 scale. Parents reported improvement in behavior, speech development, and a decrease in spasticity in children with CP. G-CSF therapy was well-tolerated. No side effects were observed during the study. Conclusions: Our preliminary report suggests that G-CSF treatment improves motor and mental function in patients with CP. Further studies are needed to confirm these observations
Źródło:
Progress in Health Sciences; 2017, 7(1); 78-82
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quality of life of children suffering from motor disabilities as evaluated by their parents
Autorzy:
Wojtkowski, J.
Sienkiewicz, D.
Okurowska-Zawada, B.
Paszko-Patej, G.
Konopka, A.
Okulczyk, K.
Średzińska, K.
Dmitruk, E.
Mirska, A.
Kułak, W.
Powiązania:
https://bibliotekanauki.pl/articles/1918580.pdf
Data publikacji:
2018-01-09
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Quality of life
motor disability
children
parents
Opis:
Purpose: We assessed the quality of life of children with motor disabilities in comparison with healthy children, as evaluated by their parents, using the CHQ-PF28 questionnaire (Child Health Questionnaire—Parent Form). Materials and methods: In a prospective study, we evaluated the quality of life of 105 children with motor disabilities. Results: Our research showed lower quality of life in the group of children with motor disabilities compared with controls, both in terms of physical and psychosocial health. Significant correlations between independent walking and physical functioning, general behavior, and mental health of children suffering from motor disabilities were found. According to the average indices of quality of life of children suffering from motor disabilities, depending on sex, the greatest differences occurred in behavior and change of health status, while the smallest differences in self-esteem and parental involvement, compared with controls. In the case of healthy children, the largest differences appeared in the perception of pain, behavior, and self-esteem; whereas, the smallest variations occurred in the change of health status and physical activity. Conclusion: Children suffering from motor disabilities demonstrate lower quality of life compared with healthy children.
Źródło:
Progress in Health Sciences; 2017, 7(2); 60-66
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Granulocyte colony-stimulating factor therapy for facioscapulohumeral dystrophy: a case report
Autorzy:
Sienkiewicz, D.
Kułak, W.
Okurowska-Zawada, B.
Paszko-Patej, G.
Wojtkowski, J.
Dmitruk, E.
Okulczyk, K.
Sochoń, K.
Kalinowska, A.
Żak, J.
Pogorzelski, R.
Powiązania:
https://bibliotekanauki.pl/articles/1918329.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Facioscapulohumeral dystrophy
granulocyte colony-stimulating factor
muscle strength
Opis:
We examined the safety and effectiveness of a low dose of analog granulocyte-colony stimulating factor in a 15-year-old boy with facioscapulohumeral dystrophy. The onset of disease was noted at 12 years of age. The physical examination noted general muscle atrophy more pronounced at left side of the body. He was able to walk 300 meters within 6 minute walk test. Granulocyte colony-stimulating factor 5 μg/kg was given subcutaneously daily for 5 days/month for 1, 2, 3, 6 and 12 months. Clinical examination, laboratory tests including blood, biochemical tests, and CD34+ cells were performed. A significant increase of muscle strength in the lower and upper limbs between baseline, and after 3 months of treatment, after 6, and after 12 months was found. He was able to walk 480 meters within 6 minutes after 12 months. Electromyography demonstrated increase of amplitude in the examined in upper and lower limbs after six months compared to baseline. Leukocyte levels remained below 25000/μL. CD34+ increased significantly at day 5 of granulocyte colony-stimulating factor admini-stration. It was safe and well tolerated by the patient. A significant increase in muscle strength in this patient with facioscapulohumeral dystrophy after 3 months of treatment, after 6, and after 12 months since the first treatment course was completed may indicate beneficial effects of granulocyte colony-stimulating factor in this disorder.
Źródło:
Progress in Health Sciences; 2016, 6(2); 175-177
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies