Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wieczorek, Krzysztof Tomasz" wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Monitoring of Partial Discharges in Cable Insulation and Cable Head Using Acoustic Method
Autorzy:
Ranachowski, Zbigniew
Wieczorek, Krzysztof
Ranachowski, Przemysław
Dębowski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2141672.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
medium voltage insulation
acoustic emission
Opis:
The article presents the application of Acoustic Emission (AE) method for detection and registration of partial discharges (PD) generated in medium voltage (MV) cable isolation and MV cable head. The insulation of the high voltage cable is made of a flexible material whose properties are characterised by a high coefficient of attenuation of the acoustic signals. For this reason, the AE method has not been used so far to detect PD in energetic cables. The subjects of the research were the MV cable and the standard T-type cable head. The cable contained defects which were the source of partial discharges. In case of cable head the PD were provoked by thin grounded electrode which was introduced into connector opening. The results of AE measurements are presented in the form of spectrograms. Acoustic Emission was evoked when the applied voltage level reached the value of 7.5 kV for the cable and 4 kV for the cable head. The authors used the acoustic instrumentation of their own design intended for future field use. Obtaining successful results of partial discharges measurements using the acoustic method in the cable insulation makes an original contribution of the presented work.
Źródło:
Archives of Acoustics; 2022, 47, 2; 259-265
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of haemodynamic effects of noninvasive ventilation delivered via ResQGARD and CPAP boussignac masks
Autorzy:
Gaszyńska, Ewelina
Roguszka, Krzysztof
Stankiewicz- Rudnicki, Michał
Wieczorek, Andrzej
Gaszyński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1396097.pdf
Data publikacji:
2013-03-01
Wydawca:
Index Copernicus International
Tematy:
mechanical ventilation
haemodynamic CPAP
Impedance Threshold Device
Opis:
Noninvasive ventilation (NIV) is a technique of mechanical ventilation which does not require invasive airway management, i.e. intubation or tracheostomy. In emergency medicine Continuous Positive Airway Pressure (CPAP) is used often. A new method of NIV is Impedance Threshold Device (ITD). Breathing through an ITD is utilized to raise blood pressure in hypotensive patients. Aim of the study was to compare haemodynamic effects of NIV ITD and NIV CPAP. Material and methods. This study involved a group of 25 healthy volunteers. NIV was performed using ResQGARD ITD and CPAP Boussignac. Ventilation time was 25 minutes for each mask in each participant. Every three minutes parameters were collected: SpO2, BP and HR. There was a one hour interval in between ventilation with each mask. CPAP pressure was set at a level of 8 cm H2O and the mean inspiratory resistance of the ITD was 7cm H2O. Collected parameters were subjected to ANOVA statistical analysis. Results. Absolute comparison of BP, HR and SpO2 values did not reveal statistically significant differences between the masks. However considering blood pressure levels at entry, ventilation through an ITD significantly raised BP. Ventilation with NIV CPAP did not change significantly BP. Conclusion. Ventilation through an ITD device significantly improve haemodynamic function, whereas CPAP ventilation had no significant effect on it.
Źródło:
Polish Journal of Surgery; 2013, 85, 3; 129-132
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies