Tytuł:
Effective Measyrand Estimators for Samples of Trapezoidal PDF-s
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/384747.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
estimators of probability density function
trapezoidal PDF
mid-range
uncertainty evaluation
Opis:
This paper is final overview of investigations on the accuracy of basic estimators of trapezoidal probability distribution samples of the measured data. For symmetrical trapezoidal PDF of straight as well concaved sides, using Monte-Carlo method of simulation, the standard deviation (SD) of linear 1- and 2-component estimators are evaluated. Approaches for theirs evaluation are proposed. It is established that in the ratio of upper and bottom bases of trapezoidal PDF in the range from 1 to 0,35 the mid-range value has smaller standard deviation (SD) than the mean value and median. It is find then for the whole family of the symmetric linear trapezoidal PDF more accurate than above single element estimators are two-component (2C) estimators as the linear form of the mean and mid-range values of the sample. Their coefficients are found, properties discussed and formulas of SD are given. The new simplified 2C-estimator of equal coefficients is also proposed. These estimators successfully extend estimation of the measurand value as the sample mean and description of its accuracy by the uncertainty type A recommended by the international guides of uncertainty evaluation in measurement GUM-2008 [1], EA-4/02 [2] and by Handbook NASA [3]. Approaches of described below investigations could be effectively applied also for other models of convoluted PDF-s.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 1; 8-14
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
About evaluation of multivariate measurements results
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/384932.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
uncertainty
indirect measurements
multi-measurand
correlated data
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 4; 27-32
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New approach to the accuracy description of unbalanced bridge circuits with the example of pt sensor resistance bridges
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/385278.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
resistance bridge
sensor
measures of accuracy
error
uncertainty of measurements
Opis:
After short introduction transfer coefficients of the unloaded four arms bridge of arbitrary variable arm resistances, supplied by current or voltage source, are given in Table 1. Their error propagation formulas are find and two rationalized forms of accuracy measures, i.e. related to the initial bridge sensitivities and of double component form as sum of zero error and increment error of the bridge transfer coefficients are introduced. Both forms of transfer coefficient measures of commonly used bridge - of similar initial arm resistances in balance and different variants of their jointed increments, are given in Table 3. As the example limited errors of some resistance bridges with platinum Pt100 industrial sensors of class A and B are calculated Table 4 and analyzed. Presented approach is discussed and found as the universal solution for all bridges and also for any other circuits used for parametric sensors.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 2; 8-15
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the uncertainty type A of the random stationary signal component from its autocorrelated observations
Autorzy:
Warsza, Z. L.
Dorozhovets, M.
Powiązania:
https://bibliotekanauki.pl/articles/114152.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sampled signal
autocorrelated signal
stationary random component
effective number of observations
Opis:
A proposal of evaluation of the uncertainty type A of the stationary random component of measured signal from its regularly sampled observations when they are auto-correlated is described. In the first step the regularly variable components of the signal are identified and removed from the raw sample data. Then upgreaded formulas for standard uncertainty type A of the sample and of the mean value are expressed with use the correction coefficients or the so-called "effective number" of observations. These quantities depend on number of observations and on the autocorrelation function of the sample cleaned from regular components. Two methods of finding and estimating the autocorrelation function for the sample data are also described. Some numerical examples are included.
Źródło:
Measurement Automation Monitoring; 2015, 61, 8; 399-402
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy analysis of the 2D resistance-to-voltage converters for resistive sensors
Autorzy:
Warsza, Z. L.
Idźkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/114306.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
converter
error
uncertainty
Opis:
The novelty of this work is the analysis of accuracy measures and its visualization especially for the simultaneous two parameter measurements. The parameters of the resistance-to-voltage converters, i.e. different types of DC circuits with arbitrary variable resistive sensors (of relative resistance increments), and their accuracy measures are discussed. Transfer coefficients, limited error (and also standard uncertainty) as functions of relative increments of resistance are shown in broad range for different types of supply and sensor configuration of the circuit of initial 2D converters.
Źródło:
Measurement Automation Monitoring; 2015, 61, 10; 460-464
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The frequency analysis of real resistors in relative values
Autorzy:
Kubisa, S.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/114711.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
resistor
AC models
equivalent circuits
impedance
parameters
frequency errors
Opis:
Three-element impedance including the resistance R as the main parameter and the residual parameters: serial inductance L and a parallel capacitance C is used as an equivalent circuit of resistor. It is the basic model of resistor for AC current. The real component of this impedance is not equal to the resistance R for the DC current, and there is the imaginary component. Both components depend on the frequency. Variants of the model with four different connections are also analyzed. Patterns of the relative resistor frequency errors in the generalized form, i.e. as a function of the relative values of resistance and frequency of the circuit are determined and their curves are given. Considerations are illustrated by few numerical examples
Źródło:
Measurement Automation Monitoring; 2016, 62, 3; 80-86
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uncertainty type A evaluation of autocorrelated measurement observations
Wyznaczanie niepewności typu A pomiarów o skorelowanych obserwacjach
Autorzy:
Warsza, Z. L.
Dorozhovets, M.
Powiązania:
https://bibliotekanauki.pl/articles/209033.pdf
Data publikacji:
2008
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
pomiar
niepewność typu A
autokorelacja
rozkład prawdopodobieństwa
measurement
uncertainty type A
autocorrelation
random distribution
Opis:
This paper briefly discusses the limitations of the international Guide ISO GUM framework and proposes improving the type A method of uncertainty evaluation of regulary sampled observations. The proposal demonstrates the influence of autocorrelation on measurement resultants and for correlated observations, the calculation of their effective number, smaller than the real value is presented. Numerical example from the computer simulation is given. Results obtained by the proposed method and classical GUM method are compared and discussed.
Krótko omówiono ograniczenia zasad wyznaczania niepewności wg zaleceń międzynarodowego Przewodnika ISO o angielskim akronimie GUM i zaproponowano udoskonalenie metody typu A szacowania niepewności pomiarów o regularnie próbkowanych obserwacjach. Przedstawiono wpływ autokorelacji na ocenę dokładności wyniku pomiarów i dla skorelowanych obserwacji zaproponowano obliczanie efektywnej ich liczby, mniejszej niż rzeczywista. Na symulowanym komputerowo przykładzie liczbowym porównano rezultaty otrzymywane metodą proponowaną i klasyczną wg GUM.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2008, 57, 2; 143-152
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Semi-parametric modification of cumulative sum algorithms for the change-point detection of non-Gaussian sequences
Autorzy:
Zabolotnii, S. W
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/114188.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
change point
CUSUM algorithm
non-Gaussian sequence
stochastic polynomial
high order statistics
Opis:
The expansion of logarithm likelihood ratio in the stochastic series to find the sequential change-point detection of non-Gaussian sequences is used. The moment criteria of the minimum of upper limit error probabilities sum to find the expansion coefficients is applied. The proposed method is a semi-parametric type of cumulative sum (CUSUM) algorithm which needs of higher-order statistics. Results show that polynomial algorithms are more effective in comparison with similar non-parametric procedures.
Źródło:
Measurement Automation Monitoring; 2015, 61, 12; 532-534
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of AC field distribution on impedance of the conductivity cell
Autorzy:
Mikhal, A. A.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/114302.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
measurement
electrolytic conductivity
electrical field
error
Opis:
The АС impedance model of a liquid conductivity has been developed to assess the influence of electromagnetic vector potential. It has been proved that the field in a liquid conductor is quasi-static. Approximation error, even taken for very concentrated solutions (e.g. sea water), does not exceed 0.01 ppm. The calculation of resistance of the four-electrode cell is given with the account of Ampere's circuit law. Two types of errors are defined: DC error due to finite thickness of electrodes, and AC error due to presence of displacement currents when using an impedance model.
Źródło:
Measurement Automation Monitoring; 2015, 61, 11; 521-525
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shifted up cosine function as unconventional model of probability distribution
Autorzy:
Warsza, Z. L.
Korczynski, M. J.
Powiązania:
https://bibliotekanauki.pl/articles/384539.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
probability density function PDF
cosines approximation of normal distribution
Opis:
The shifted up one period of cosine function with field under it normalized to 1 is proposed to be use as the un conventional model of probability density function (PDF). It could also approximate Normal probability distribution in the range š 2.5 standard deviation with accuracy of about š0.02, which is fully acceptable in the evaluation of measurement uncertainty. In this paper the properties of the above cosine based PDF are considered. The possibility of its applications in the routine data assessment and in virtual instruments with automatic uncertainty calcula tions is recommended.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 1; 49-55
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robust estimation in interlaboratory measurements with small number of measurements
Autorzy:
Volodarsky, E. T.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/114483.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interlaboratory comparisons
proficiency testing of laboratory outliers
robust statistics
precision
uncertainty of measurements
Opis:
In this paper two robust methods of assessing the value and the uncertainty of the measurand from the samples of small number of experimental data are presented and compared. Those methods can be used when some measurements results contain outliers, i.e. when the values of certain measurement results significantly differ from the others. They allow to set a credible statistical parameters of the measurements with the use of all experimental data. The following considerations are illustrated by the numerical examples of multi-laboratory measurement data key comparison. Compared are the results obtained by a classical method with rejection of outliers with two robust methods: a rescaled median absolute deviation MADS and an iterative two-criteria method. The paper also presents the advantages of the robust iterative statistical method in estimating the accuracy of the tested laboratory measurement results during its accreditation on the sample of four elements with outlier. A comparison with the estimates obtained by the standard procedure for evaluating performance accuracy is also provided.
Źródło:
Measurement Automation Monitoring; 2015, 61, 4; 104-110
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uncertainty evaluation of the minimal value measurements
Autorzy:
Dorozhovets, M.
Warsza, Z. L.
Popovych, I.
Powiązania:
https://bibliotekanauki.pl/articles/114616.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
minimal value of observations
uncertainty type A
Opis:
The non-standard statistical method for evaluating uncertainty for a minimal value of observations as the measurement result, is proposed. This method is based on properties of minimal order statistic. As example from the practice this method is used to evaluate the uncertainty of a percent elongation and tensile strength in testing plastic products.
Źródło:
Measurement Automation Monitoring; 2015, 61, 8; 395-398
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous measurement of two parameters by double current supplied bridge
Autorzy:
Idzkowski, A.
Makal, J.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/384411.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
multivariable measurement circuits
bridge circuit
strain measurement
Opis:
A four-terminal (4T) bridge-circuit, with two voltage outputs is presented. This circuit, named as double current bridge is supplied by two equal current sources connected in parallel to opposite arms (2J) or by one such source switched between those arms (2x1J). Two output voltages from bridge diagonals as functions of arm resistance increments in absolute and in relative units are given. Also the example of this bridge application is proposed. Signal conditioning formulas of two-parameter measurement on the example of strain and temperature are discussed in detail. Some results obtained with the use of this bridge-circuit are briefly described.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 2; 26-31
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental evaluation of dynamic properties of the four electrode reference conductivity cells
Autorzy:
Mikhal, A. A.
Warsza, Z. L.
Gavrylkin, V. G.
Powiązania:
https://bibliotekanauki.pl/articles/114164.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
primary conductivity standard
cell dynamics
uncertainty
Opis:
Dynamic properties of the four-electrode cell with conducting liquid inside are described in the paper. The cell is used as a sensor of the electrolytic conductivity (EC) in the national Ukrainian standard. Electrical model and physical model for the temperature changes of this sensor are presented. To avoid additional measurement errors the stable state in desired temperature should be obtain. To obtain values of parameters describing the dynamic process of EC cell for temperature changes the experimental way was chosen. Installation and measurement procedure is presented. It is found that temperature transition process in the EC cell can be modeled by the first order differential equation and depends mainly on two cell tubes. For establishing the cell temperature within an error less then 0.002ºC time 36 min is needed.
Źródło:
Measurement Automation Monitoring; 2015, 61, 10; 456-459
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the hybrid balanced ratiometric measurement method in the high-precision ac thermometry bridges
Zastosowanie hybrydowej kompensacyjno-ilorazowej metody pomiaru w wysoko precyzyjnych temperaturowych mostkach AC
Autorzy:
Mikhal, A. A.
Meleshchuck, D.V.
Warsza, Z.L.
Powiązania:
https://bibliotekanauki.pl/articles/129543.pdf
Data publikacji:
2019
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
high precision temperature measurement
AC bridge
balanced-ratiometric measurement method
hybrid method
dokładny pomiar temperatury
mostek AC
metoda hybrydowa
metoda kompensacyjno-ilorazowa
Opis:
The paper article describes the circuit of an automatic AC bridge for high precision temperature measurements using a standard platinum SPRT sensor. An original method for measuring the impedance parameters of SPRT sensor which allows to carry out the measurement process without loss of accuracy, is described in detail. This measurement method is proposed to name as hybrid method. It is a combination of a balanced method for rough compensation of the circuit and a ratiometric method which accurately measures the ratio of two values of the imbalance signal, before and after its known change. With this method, the measuring circuit also does not require a circuit to compensate for the reactive component of the SPRT sensor impedance. The inductive voltage divider with lower number of digits is needed only for the coarse compensation. This circuit is simpler and at lower cost of the hardware resources allows to achieve the same accuracy as the most accurate thermometric bridges with fully balanced circuits.
W artykule opisano oryginalną zasadę budowy układu pomiarowego automatycznego mostka AC (prądu przemiennego) do bardzo dokładnych pomiarów temperatury za pomocą wzorcowego platynowego czujnika SPRT. Wykorzystuje się oryginalną kombinowaną, tj. kompensacyjno-ilorazową metodę pomiaru, którą nazwano tu krócej: metodą hybrydową. Obejmuje ona połączenie metody kompensacyjnej do zgrubnego zrównoważenia układu i metody ilorazowej (ratiometric), którą wyznacza się stosunek dwu wartości sygnału nierównowagi, przed i po znanej jego zmianie. Układ pomiarowy nie wymaga stosowania obwodu do kompensacji wpływu reaktancji czujnika SPRT. Zmniejsza się też niezbędna liczba dekad dzielnika indukcyjnego kompensującego zgrubnie sygnał składowej rezystancyjnej czujnika. Układ taki pozwala w prostszy sposób i przy niższychkosztach wykonania uzyskać tę samą dokładność co najdokładniejsze termometryczne mostki AC o układach całkowicie zrównoważonych.
Źródło:
Physics for Economy; 2019, 3, 1; 29-40
2544-7742
2544-7750
Pojawia się w:
Physics for Economy
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies