Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sobota, Ł." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Precipitation Processes during Non-Isothermal Ageing of Fine-Grained 2024 Alloy
Autorzy:
Kozieł, J.
Błaż, L.
Włoch, G.
Sobota, J.
Lobry, P.
Powiązania:
https://bibliotekanauki.pl/articles/352499.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AA2024 alloy
scrap metal milling
structure refining
powder metallurgy
precipitation hardening
Opis:
Mechanical alloying and powder metallurgy procedures were used to manufacture very fine-grained bulk material made from chips of the 2024 aluminum alloy. Studies of solution treatment and precipitation hardening of as-received material were based on differential scanning calorimetry (DSC) tests and TEM/STEM/EDX structural observations. Structural observations complemented by literature data lead to the conclusion that in the case of highly refined structure of commercial 2024 alloys prepared by severe plastic deformation, typical multi-step G-P-B →θ” →θ’ →θ precipitation mechanism accompanied with G-P-B →S” →S’ →S precipitation sequences result in skipping the formation of metastable phases and direct growth of the stable phases. Exothermic effects on DSC characteristics, which are reported for precipitation sequences in commercial materials, were found to be reduced with increased milling time. Moreover, prolonged milling of 2024 chips was found to shift the exothermic peak to lower temperature with respect to the material produced by means of common metallurgy methods. This effect was concluded to result from preferred heterogeneous nucleation of particles at subboundaries and grain boundaries, enhanced by the boundary diffusion in highly refined structures. Transmission electron microscopy and diffraction pattern analysis revealed the development of very fine Al4C3 particles that grow due to the chemical reaction between the Al matrix and graphite flakes introduced as a process control agent during the preliminary milling of chips. Al4C3 nano-particles are formed at high temperatures, i.e. during hot extrusion and the subsequent solution treatment of the samples. Highly refined insoluble particles such as aluminum carbide particles and aluminum oxides were found to retard recrystallization and reduce recovery processes during solution treatment of preliminarily milled materials. Therefore, the as-extruded material composed of a milled part and chip residuals retained its initial bimodal structure in spite of solution heat treatment procedures. This points to a high structural stability of the investigated materials, which is commonly required for new technologies of high-strength Al-based materials production.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 1; 169-176
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Silver Matrix Composite Reinforced by Aluminium-Silver Intermetallic Phases
Autorzy:
Wloch, G.
Skrzekut, T.
Sobota, J.
Woznicki, A.
Błaż, L.
Powiązania:
https://bibliotekanauki.pl/articles/352667.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
silver-aluminum composite
plastic consolidation
powder metallurgy
Ag-Al intermetallics
Opis:
Silver and aluminum powders (82 mass % Ag and 18 mass % Al) were mixed and hot extruded at 673 K with extrusion ratio λ = 25. Performed X-ray diffraction analysis of as extruded rod revealed the development of Ag3Al and Ag2Al-type intermetallic phases. Structural observations and both chemical and diffraction analysis of structural components confirmed the growth of mentioned phases in the vicinity of elementary Al and Ag granules. No pores or voids were observed in the material. Mechanical properties of the composite, UTS = 490MPa, YS = 440 MPa, HV2 = 136, were relatively high if compared to commercial Ag and Cu products. Hot compression tests pointed to the good hot workability of the composite at deformation temperature range 473 K - 773 K. The differential scanning calorimetry tests were performed in order to estimate structural processes during heating of Ag/Al composite that lead to thermodynamically stable liquid state. It was found that characteristic temperature of three endothermic peaks correspond to (1) peritectoid transformation μ-Ag3Al → ζ-Ag2Al + (Ag), (2) the eutectic melting ζ-Ag2Al + (Al) → L, (3) melting of the ζ-Ag2Al phase. The Vickers hardness of the samples annealed at 673 K, for the time range up to 6900 minutes, was also determined. It was concluded that mutual diffusion of elements between Ag and Al granules and the growth of μ-Ag3Al and ζ-Ag2Al grains during annealing at 673 K result in a slight hardening of the composite.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 1; 427-434
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinematic gait parameters changes in patients after total knee arthroplasty : Comparison between cruciate-retaining and posterior-substituting design
Autorzy:
Hajduk, G.
Nowak, K.
Sobota, G.
Kusz, D.
Kopeć, K.
Błaszczak, E.
Cieliński, Ł.
Bacik, B.
Powiązania:
https://bibliotekanauki.pl/articles/306649.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw kolanowy
endoprotezoplastyka
analiza lokomocji
total knee arthroplasty
gait analysis
cruciate retaining
posterior substituting
Opis:
Purpose: The patients expect optimal knee function after Total Knee Arthroplasty. It is necessary to apply appropriate surgical technique and supervised physical therapy. The optimal management of posterior cruciate ligament remains controversial. Both implant designs, i.e., cruciate retaining and posterior substituting, allow the orthopedic surgeon to achieve excellent clinical outcomes, as measured by commonly used questionnaires. Such methods of assessment may poorly reflect the functional status of patients. Therefore, three-dimensional gait analysis is recommended to evaluate the outcomes of surgical intervention. This study sought to determine differences in kinematic gait parameters and Knee Society Score between cruciate-retaining and posterior-substituting patients. Methods:23 individuals after cruciate-retaining total knee arthroplasty and 19 individuals after posterior-substituting total knee arthroplasty were subjected to gait analysis using three-dimensional motion capture system BTS Smart DX 7000. In addition, gait was assessed in 21 patients with knee osteoarthritis and in 30 healthy individuals. Results: The study did not reveal differences between cruciate-retaining and posterior-substituting groups, both in terms of Knee Society Score and kinematic gait parameters. There were also no differences in kinematic gait parameters between patients from the knee osteoarthritis group and total knee arthroplasty groups. The analyzed parameters in all of the groups differed significantly from those found in healthy individuals. Conclusions: Surgical technique and implant design do not affect values of kinematic gait parameters evaluated under natural walking speed. Several months after surgery the patients still demonstrated alterations in gait pattern, similar to those recorded in patients with knee osteoarthritis.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 137-142
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies