Tytuł:
Reduction of the step voltages of MV/LV substation grounding system based on shaping electric field
Autorzy:
Sikora, Roman
Markiewicz, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/1841172.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
grounding system
step voltage
touch voltage
IEEE 80-2013 standard
system uziemiający
napięcie krokowe
napięcie dotykowe
Standard IEEE 80-2013
Opis:
The article presents the analysis results of the effectiveness limitation of the step voltage by forming an electric field on the ground surface. For shaping the electric field, a method consisting of screens placed around the point of the earth current flow was used. The analysis was performed using an example of an MV/LV substation grounding system. This research was conducted applying a mathematical model of the grounding system and screens by means of the finite element method. The influence of metal, insulating screens and surface material on the step/touch voltage values for the considered grounding system was estimated. Most of the methods described can be applied in practice. In the opinion of the authors, the method of using screens made of insulating and conductive materials has not been sufficiently described in the literature. Moreover, in the available literature there is no in-depth analysis of the described electric field shaping methods.
Źródło:
Archives of Electrical Engineering; 2021, 70, 3; 601-613
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active power losses and energy efficiency analysis of HPS lamps with electromagnetic control gear and electronic ballast under the sinusoidal and nonsinusoidal condition
Autorzy:
Sikora, Roman
Markiewicz, Przemysław
Rózga, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2173621.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
HPS lamps
electromagnetic control gear
electronic ballast
energy performance indicator
road lighting
lampa HPS
układ sterowania elektromagnetyczny
balast elektroniczny
wskaźnik wydajności energetycznej
oświetlenie drogowe
Opis:
Outdoor lighting is an important element in creating an evening and nocturnal image of urban spaces. Properly designed and constructed lighting installations provide residents with comfort and security. One way to improve the energy efficiency of road lighting installation is to replace the electromagnetic control gear (ECG) with electronic ballasts (EB). The main purpose of this article is to provide an in-depth comparative analysis of the energy efficiency and performance of HPS lamps with ECG and EB. It will compare their performance under sinusoidal and nonsinusoidal voltage supply conditions for the four most commonly used HPS lamps of 70 W, 100 W, 150 W, and 250 W. The number of luminaires supplied from one circuit was determined based on the value of permissible active power losses. With the use of the DIALux program, projects of road lighting installation were developed. On this basis, energy performance indicators, electricity consumption, electricity costs, and CO 2 emissions were calculated for one-phase and three-phase installations. The obtained results indicate that an HPS lamp with EB is better than an HPS lamp with ECG in terms of energy quality, energy savings, and environmental impact. The results of this analysis are expected to assist in the choice of HPS lighting technology.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; art. no. e137194
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An accurate model of LED luminaire using measurement results for estimation of electrical parameters based on the multivariable regression method
Autorzy:
Sikora, Roman
Markiewicz, Przemysław
Rózga, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2106413.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LED light source
LED luminaire
linear regression
electrical parameters measurement
Opis:
Light sources and luminaires made in the LED technology are nowadays widely used in industry and at home. The use of these devices affects the operation of the power grid and energy efficiency. To estimate this impact, it is important to know the electrical parameters of light sources and luminaires, especially with the possibility of dimming. The article presents the results of measurements of electrical parameters as well as luminous flux of dimmable LED luminaires as a function of dimming and RMS supply voltage. On the basis of the performed measurements, a model of LED luminaire was developed for prediction of electrical parameters at set dimming values and RMS values of the supply voltage. The developed model of LED luminaire has 2 inputs and 26 outputs. This model is made based on 26 single models of electrical parameters, whose input signals are supply and control voltages. The linear regression method was used to develop the models. An example of the application of the developed model for the prediction of electrical parameters simulating the operation of an LED luminaire in an environment most similar to real working conditions is also presented.
Źródło:
Metrology and Measurement Systems; 2022, 29, 2; 251--269
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active power losses and energy efficiency analysis of HPS lamps with electromagnetic control gear and electronic ballast under the sinusoidal and nonsinusoidal condition
Autorzy:
Sikora, Roman
Markiewicz, Przemysław
Rózga, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2128159.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
HPS lamps
electromagnetic control gear
electronic ballast
energy performance indicator
road lighting
lampa HPS
układ sterowania elektromagnetyczny
balast elektroniczny
wskaźnik wydajności energetycznej
oświetlenie drogowe
Opis:
Outdoor lighting is an important element in creating an evening and nocturnal image of urban spaces. Properly designed and constructed lighting installations provide residents with comfort and security. One way to improve the energy efficiency of road lighting installation is to replace the electromagnetic control gear (ECG) with electronic ballasts (EB). The main purpose of this article is to provide an in-depth comparative analysis of the energy efficiency and performance of HPS lamps with ECG and EB. It will compare their performance under sinusoidal and nonsinusoidal voltage supply conditions for the four most commonly used HPS lamps of 70 W, 100 W, 150 W, and 250 W. The number of luminaires supplied from one circuit was determined based on the value of permissible active power losses. With the use of the DIALux program, projects of road lighting installation were developed. On this basis, energy performance indicators, electricity consumption, electricity costs, and CO 2 emissions were calculated for one-phase and three-phase installations. The obtained results indicate that an HPS lamp with EB is better than an HPS lamp with ECG in terms of energy quality, energy savings, and environmental impact. The results of this analysis are expected to assist in the choice of HPS lighting technology.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; e137194, 1--22
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physical and reliability aspects of high-pressure ammonia water pipeline failures
Autorzy:
Michnej, Maciej
Młynarski, Stanisław
Pilch, Robert
Sikora, Wojciech
Smolnik, Maksymilian
Drożyner, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/2200924.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
coke oven battery
pipeline
welded joint
crack
structural analysis
reliability assessment
Opis:
The paper concerns the problem of the occurrence of failures of the high-pressure ammonia water pipeline of the coke oven battery complex, which is affected by chemical and thermal factors as well as the operating pressure occurring during its use. Pipeline failures manifested themselves as leaks (leakage of the medium) due to cracks in the area of the pipeline thermal elongation compensators. The conducted tests included, among others: visual inspection, penetration tests, macroscopic and microscopic tests as well as chemical analysis of the material. The study includes microscopic photographs of the material structure and cracks. The results of the pipeline strength and reliability analysis were also presented. On the basis of the conducted research and analyses conclusions were formulated. The assumed cause of the damage was the incorrectly made welded joints. Formulated recommendations and proposals for actions aimed at avoiding further failures of this and similar pipelines were related to the inspection time and preventive renewal.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 4; 728--737
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies