Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pyrc, R." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
The role of orographic barriers in the origin of extreme rainfalls as exemplified by the front of high Eastern Himalaya and the low northern slope of Carpathians
Autorzy:
Cebulak, E.
Gębica, P.
Limanówka, D.
Starkel, L.
Pyrc, R.
Powiązania:
https://bibliotekanauki.pl/articles/294907.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Geomorfologów Polskich
Tematy:
heavy rainfalls
morphological barriers
floods
Himalayas
Carpathians
ulewne deszcze
bariery morfologiczne
powodzie
Himalaje
Karpaty
Opis:
The paper discusses the role of orographic barriers in generating torrential precipitation in mountainous regions in different climatic zones, the Eastern Himalayas (tropical zone with well-developed monsoon activity) and the northern slope of the Carpathians (temperate zone with transitional climate). Attention has been paid to the different altitudes and courses of the orographic ridges as well as their location relative to the prevailing directions of influx of moist air masses. The cases analysed included torrential rains with monsoon circulation from the S–SW direction at the 2–3 km high edge of the Himalayas, with special consideration to the distance from the margin of the mountains and the exposure of the slopes. They generate frequent flood waves, landslides, debris flows and upbuilding of the alluvial cones in the foreland of the mountain barriers. The impact of the orographic barrier is significantly less marked in the Polish Carpathians. In the western part, the compact edge of the Western Beskids with an altitude of 0.5–1 km and the WSW–NEE course, exposed to moist air masses inflowing from the northern sector, is fragmented eastward into smaller mountain groups, which facilitates the penetration of moist masses of air with occurrence of prolonged precipitation into the mountains. At times, the storm cloud moves along the mountain edge (the margin of the Western Bieszczady Mts.). The marginal scarp of the Foothills has a northern exposure and a height of 150–200 m, and promotes frequent convective precipitation causing local flash floods in small streams. The cases of downpours and high discharges selected for the analysis were those for which there was available a dense network of measuring stations. An insufficient number of stations in constructing precipitation maps based on interpolation would lead to distorting the spatial image. If this were the case, then the role of slope exposure, which has an essential impact on the distribution of precipitation in mountainous regions, would be completely neglected.
Źródło:
Landform Analysis; 2018, 36; 9-17
1429-799X
Pojawia się w:
Landform Analysis
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combustion of RME – diesel and NExBTL – diesel blends with hydrogen in the compression ignition engine
Autorzy:
Juknelevičius, R.
Szwaja, S.
Pyrc, M.
Gruca, M.
Pukalskas, S.
Powiązania:
https://bibliotekanauki.pl/articles/247823.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
hydrogen
RME
HVO
NExBTL
PRO Diesel
diesel fuel
CI engine
combustion
emission
Opis:
The article presents the test results of the single cylinder compression ignition engine with common rail injection system operating on biofuels and conventional diesel blends with hydrogen. Two types of liquid fuels were tested: blend of the 7% Rapeseed Methyl Ester (RME) with conventional diesel fuel and Neste Pro Diesel – blend of the 15% Hydrotreated Vegetable Oil (HVO), produced by Neste Oil Corporation with conventional diesel fuel. The purpose of this investigation was to examine the influence of the hydrogen addition to biofuels and diesel blends on combustion phases, autoignition delay, engine performance efficiency and exhaust emissions. Hydrogen fraction was changed within the range from 0 to 43% by energy. Hydrogen was injected into the intake manifold, where it created homogeneous mixture with air. Tests were performed at both fixed and optimal injection timings at low, medium, and nominal engine load. After analysis of the engine bench tests and simulation with AVL BOOST software, it was observed that increasing hydrogen fraction shortened the fuel ignition delay phase and it affected the main combustion phase. Moreover, decrease of carbon monoxide (CO), carbon dioxide (CO2) and smoke opacity was observed with increase of hydrogen amounts to the engine. However, increase of the nitrogen oxide (NOx) concentration in the engine exhaust gases was observed.
Źródło:
Journal of KONES; 2018, 25, 3; 261-274
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological Contamination of Water in Fountains Located in the Ciechocinek Health Resort
Zanieczyszczenie mikrobiologiczne wody pochodzącej z fontann zlokalizowanych w uzdrowisku Ciechocinek
Autorzy:
Budzińska, K.
Pyrc, N.
Szejniuk, B.
Pasela, R.
Traczykowski, A.
Michalska, M.
Berleć, K.
Powiązania:
https://bibliotekanauki.pl/articles/1813904.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water
fountains
contamination
bacteria
microscopic fungi
woda
fontanny
zanieczyszczenie
bakterie
grzyby mikroskopowe
Opis:
Fountains located in health resorts frequently serve as therapeutic waters intended for recreational and balneological purposes. Therefore, the quality of water and air around such objects is crucial for patients using the fountains. Fountain water conducive to the occurrence of pathogen microorganisms, such as: coliform bacteria, staphylococci, streptococci, Salmonella spp. and microscopic fungi. They mostly cause a gastrointestinal and skin infections. The research here presented aimed at the assessment of the degree of bacterial and fungal contamination of water samples taken from fountains located in the Ciechocinek health resort from the perspective of biosafety of tourists and patients. Microbiological analysis of the water sample was taken from four fountains (object A-D), one of which (object C) was supplied with brine water.The plate method was used to determination of a total count of bacteria and a total count of fungi in the water samples. For the quantitative determination of coliform bacteria, Escherichia coli, staphylococci and streptococci, the membrane filter technique was employed. The studies showed that the samples of water from fountains contained bacteriological and mycological contamination in which microfungi being the most abundant group. The water samples contained a few cells of E. coli, fecal streptococci and staphylococci. The most frequently indentified indicator bacteria in sample water from fountain D were faecal streptococci (3.17·101 cfu/100 ml). The water samples coming from the object B and D and in most water samples from the object C, there was no presence of these bacteria. As the data indicate, the largest differences regarding the population of those microorganisms were between water samples taken from Fountain B and C. The highest frequency of the occurrence of the E. coli bacilli was recorded in fountain A, while they occurred once in research series 5 taken from fountain C. The mean amount of these bacteria in the water samples taken from Fountain D was 5.76·100 cfu/100 ml, which was more than 40 times higher than the mean population of these microorganisms isolated from the water taken from Fountain C (0.14·100 cfu/100 ml). The studies demonstrate that the least number of coliform bacteria and E. coli was found in fountain C, where 4.51% brine water was used. The highest number of staphylococci during the entire research period was determined in water sample taken from fountain D (7.9·101 cfu/100 ml), while in water sample taken from fountains A and C and in sample from fountain B, no such bacteria were found. Occurrence of faecal bacteria, staphylococci and microscopic fungi in water may pose a risk of diseases for people who use the fountains. The research indicated that it is necessary to perform monitoring of fountain water and introduce legal regulations regarding its sanitary and hygiene condition.
Fontanny zlokalizowane na terenach uzdrowiskowych często są wykorzystywane jako wody lecznicze przeznaczone do celów rekreacyjnych oraz balneologicznych. W związku z tym bardzo ważna dla kuracjuszy korzystających z fontann jest jakość wody i powietrza wokół tych obiektów. Woda pochodząca z fontann sprzyja występowaniu mikroorganizmów chorobotwórczych takich jak: bakterie grupy coli, gronkowce, paciorkowce, pałeczki z rodzaju Salmonella oraz grzyby mikroskopowe. Powodują one przede wszystkim zakażenia o charakterze żołądkowo-jelitowym oraz infekcje skórne. Celem pracy była ocena stopnia zanieczyszczenia bakteriologicznego i mikologicznego próbek wody pobieranych z fontann, zlokalizowanych na terenie uzdrowiska Ciechocinek w aspekcie bezpieczeństwa sanitarnego turystów i kuracjuszy. Analizie mikrobiologicznej poddano próbki wody pobrane z czterech fontann (obiekty A-D), z których jedna (obiekt C) była zasilana wodą solankową. Metodą płytkową oznaczono ogólną liczbę bakterii i grzybów mikroskopowych. Do oznaczenia ilościowego bakterii grupy coli, Escherichia coli, paciorkowców kałowych oraz gronkowców wykorzystano metodę filtrów membranowych. W wyniku przeprowadzonych badań stwierdzono, że próbki wody pochodzące z fontann zawierały zanieczyszczenia bakteriologiczne i mikologiczne, przy czym najliczniej reprezentowane były grzyby mikroskopowe. W próbkach wody występowały pojedyncze komórki E. coli a także paciorkowce kałowe oraz gronkowce. Najliczniej paciorkowce kałowe identyfikowano w próbce wody pobranej z fontanny D (3,17·101 jtk/100 ml). W próbkach wody pochodzących z obiektu B i D oraz w większości próbek wody z obiektu C nie stwierdzono obecności tych bakterii. Największe różnice dotyczące liczebności tych mikroorganizmów wystąpiły w przypadku próbek wody pochodzących z fontanny B i C. W obiekcie A notowano najwyższą częstotliwość występowania pałeczek E. coli, natomiast w przypadku fontanny C występowały one w jednym przypadku w wody pochodzącej z 5 serii badawczej. Średnia liczba bakterii Escherichia coli w próbkach wody pobranej z obiektu D wynosiła 5,76·100 jtk/100 ml i była ponad 40-krotnie wyższa od średniej liczebności tych drobnoustrojów izolowanych z wody pochodzącej z obiektu C (0,14·100 jtk/100 ml). Badania wykazały, że najmniej bakterii grupy coli i E. coli stwierdzono w obiekcie C, w którym wykorzystywano wodę solankową o zasoleniu 4,51%. Największą liczbę gronkowców w ciągu całego okresu badań oznaczono w próbce wody pobranej z obiektu D (7,9·101 jtk/100 ml), natomiast w niektórych próbkach wody ujętej z obiektu A i C oraz B nie stwierdzono obecności tych bakterii. Występowanie w wodzie bakterii fekalnych, gronkowców, jak również grzybów mikroskopowych może stwarzać ryzyko zachorowań u ludzi korzystających z fontann. Przeprowadzone badania wskazują na konieczność prowadzenia monitoringu wody pochodzącej z fontann, a także na wprowadzenie regulacji prawnych dotyczących ich stanu sanitarno-higienicznego.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 181-199
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies