Tytuł:
Field-circuit analysis of AC machine taking into account stator winding asymmetry
Autorzy:
Pietrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/1813709.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
winding asymmetry
induction machine
axial flux
field-circuit model
Opis:
The paper presents the influence of an asymmetry of a stator winding on an axial flux in AC machine. The objective research was performed for selected values of asymmetry. The axial flux was calculated as the sum of flux linkage with stator winding. In order to achieve a magnetic field distribution a dedicated 2D finite element model of AC machine was elaborated. The waveforms of axial flux and torque-time characteristic have been shown. It can be concluded that the asymmetry has significant impact on the axial flux and the pulsation of torque.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 386-392
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Funds of local government units in regional operational programmes 2007-2013 and 2014-2020
Środki jednostek samorządu terytorialnego w regionalnych programach operacyjnych 2007-2013 i 2014-2020
Autorzy:
Pietrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/2048758.pdf
Data publikacji:
2022-03-31
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
regional operational programme
regional programme financing
national contribution
local government unit expenditure
Opis:
Subject and purpose of work: The article concerns own contribution of local government units involved in the Regional Operational Programmes. The aim of the research is to assess the amount of own funds in the projects implemented under the ROP Materials and methods: The article analyses the secondary data obtained from the Local Data Bank, the data from the programme documents and available literature. Results: As the study has shown, no significant differences were found in the disbursement of funds in different years. However, in the perspective 2014-2020, the amount of local governance units contribution is higher. Conclusions: The regional distribution of the local government units resources in the particular regional programmes is strongly related to the total amount of the entire programme, but there is a noticeable variation between the perspectives. Still, local governance units own resources outweigh the national contribution.
Źródło:
Economic and Regional Studies; 2022, 15, 1; 34-46
2083-3725
2451-182X
Pojawia się w:
Economic and Regional Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spectral analysis of phase currents of LSPMSM at asymmetric voltage supply
Spektralna analiza prądów stojana silnika LSPMSM przy niesymetrycznym zasilaniu
Autorzy:
Idziak, P.
Nowak, M.
Pietrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/972163.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
power supply asymmetry
synchronous motor
permanent magnets
niesymetria zasilania
silnik synchroniczny
magnesy trwałe
Opis:
This paper presents a spectral analysis of the stator currents at power supply asymmetry of the line start synchronous motor with permanent magnets. The study was conducted for various levels of asymmetry of motor voltage and different values of load. The tested motor was developed in the Department of Mechatronics and Electrical Machines at Poznan University of Technology. The construction of the stator is based on the mass-produced four-pole, three-phase induction motor type Sg100L-4B. The examined motor has rotor with u-shaped permanent magnets. In order to control the level of asymmetry of the motor voltage supply, the system was supplied from three auto-transformers. The voltage in one phase varied in the range from -10% to +10% of rated value. To adjust the value of the load motor was connected with the eddy current brake.
W artykule przedstawiona została analiza spektralna prądów stojana przy niesymetrii zasilania silnika synchronicznego z magnesami trwałymi o rozruchu bezpośrednim. Badania przeprowadzono dla różnego stopnia niesymetrii napięcia zasilającego silnik oraz różnych wartości obciążenia silnika. Badany silnik został opracowany w Zakładzie Mechatroniki i Maszyn Elektrycznych Politechniki Poznańskiej. Konstrukcję stojana oparto na bazie seryjnie produkowanego czterobiegunowego, trójfazowego silnika indukcyjnego typu Sg100L-4B. Rozpatrywany silniki ma w wirniku klatkę rozruchową oraz magnesy trwałe rozmieszczone w formie litery „U”. W celu regulacji stopnia niesymetrii układ silnik zasilany był z trzech autotransformatorów. Napięcie w jednej z faz zmieniano w granicach od -10% do +10% wartości znamionowej. Aby regulować wartość obciążenia silnik sprzężono z hamulcem wiroprądowym. Do rejestracji i archiwizacji danych zastosowano system komputerowy z kartą pomiarową National Instruments NI PCI-6123 oraz oprogramowaniem LabVIEW.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 10, 10; 1032-1035
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining the optimal working point and the loading characteristic of synchronous machine for fan and pump drive system
Autorzy:
Nowak, L.
Kowalski, K.
Stachowiak, D.
Mikołajewicz, J.
Pietrowski, W.
Radziuk, K.
Powiązania:
https://bibliotekanauki.pl/articles/97525.pdf
Data publikacji:
2011
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
synchronous motor
electric motor
pump drives
Opis:
In the paper the computer software for determining the optimal working point of electric motors for fan (and pump) drive systems is presented. The main use of this software is the preliminary designing of permanent magnet synchronous motor for such type of drives. The second task of the software is determining the load characteristic of the fan system (pump system), i.e. relationship between loading torque and angular speed. The obtained characteristics can be used in the designing of control system for fan or pump drives.
Źródło:
Computer Applications in Electrical Engineering; 2011, 9; 139-149
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies