Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pałko, T." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Overview of some non-invasive spectroscopic methods of glucose level monitoring
Przegląd wybranych nieinwazyjnych spektroskopowych metod monitorowania poziomu glukozy
Autorzy:
Osiecka, I.
Pałko, T.
Powiązania:
https://bibliotekanauki.pl/articles/261198.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
diabetes
glucose sensor
spectroscopic techniques
cukrzyca
czujniki glukozy
techniki spektroskopowe
Opis:
Nowadays over 400 million adults suffer from diabetes worldwide. By 2040 this number will rise to 642 million. In addition, more than 300 million adults have impaired glucose tolerance, which means a high risk of developing the disease in the future. Also, many patients are undiagnosed, which results in severe complications. It is an important social problem, because from the moment of recognition the treatment lasts a lifetime. Currently, mainly devices based on invasive, electrochemical or photosensitive methods to measure glucose concentration in small blood samples, are offered on the market. Hence, the development of a new non-invasive glucose sensor is a desirable goal. Such measurement system should be cost-effective, comfortable and allowing continuous monitoring of glucose levels in blood. There are many reports on new, fast and highly sensitive methods and the most common research direction relates to spectroscopic techniques. Some of them are presented in this paper.
Obecnie ponad 400 milionów osób dorosłych na całym świecie cierpi na cukrzycę. Do 2040 roku liczba ta ma wzrosnąć do 642 milionów. Ponadto, u więcej niż 300 milionów dorosłych zdiagnozowano upośledzenie tolerancji glukozy, a to stwarza ryzyko rozwoju choroby w przyszłości. Bardzo wiele osób jest niezdiagnozowanych. Cukrzyca stanowi istotny problem społeczny, ponieważ od momentu rozpoznania leczenie trwa przez całe życie. Obecne na rynku urządzenia, to przede wszystkim oferujące inwazyjne techniki pomiarowe: elektrochemiczne lub światłoczułe. Dlatego też prowadzone są intensywne badania mające na celu opracowanie czujników nieinwazyjnych, pozwalających na poprawę komfortu życia, oszczędność i wygodę w pomiarze poziomu glukozy we krwi. W literaturze opisano wiele nowych rozwiązań w tym zakresie, opierających się głównie na technikach spektroskopowych. Niektóre z nich są omówione w niniejszej publikacji.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2016, 22, 1; 1-8
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of volumetric parameters of the ventricular assist device using bioimpedance method
Autorzy:
Sobotnicki, A.
Pałko, T.
Mocha, J.
Czerw, M.
Powiązania:
https://bibliotekanauki.pl/articles/333273.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
sztuczne serce
urządzenia wspomagające pracę komór
metoda bioimpedancji
artificial heart
ventricular assist device (VAD)
stroke volume estimation
bioimpedance method
Opis:
Volumetric parameters of operation of the pulsatile ventricular assist device (VAD) are the key clinical indicators for the evaluation of adequacy of the process of mechanical heart assistance and ensuring the patient's safety. The bioimpedance method has been proposed to evaluate blood volume changes of the VAD. The method is based on volume electric conductivity of the blood. A change in VAD volume involves changes in impedance. Periodic changes in VAD volume during its operation result in a pulsatile impedance wave; its amplitude in the subperiod of filling and ejection correlates with the volume of blood in the VAD. The paper presents the way of acquisition of the bioimpedance signal. It also presents the results of experimental studies, that were carried out with the use of the flow test stand, and an approach to analysing the bioimpedance signal to evaluate the stroke volume.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 19; 117-123
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of stroke volume of the ventricular assist device using bioimpedance method
Autorzy:
Sobotnicki, A.
Gacek, A.
Pałko, T.
Mocha, J.
Badura, G.
Czerw, M.
Powiązania:
https://bibliotekanauki.pl/articles/332979.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
artificial heart
ventricular assist device
VAD
stroke volume
bioimpedance method
impedance cardiography
ICG
sztuczne serce
urządzenie wspomagające pracę komór serca
metoda bioimpedancji
kardiografia impedancyjna
Opis:
The stroke volume of pulsatile ventricular assist device (VAD) is one of the key clinical indicators to evaluate the adequacy of the process of mechanical heart assistance and ensuring the patient’s safety. In order to evaluate the volume changes in VAD blood chamber, a bioimpedance method was applied, based on volumetric electric conductivity of the blood. Periodic changes in VAD volume during its operation result in a pulsatile impedance waveform; its amplitude in the subperiods of filling and ejection correlates with blood volume in the chamber. The paper presents the method of analysis of the bioimpedance signal recorded in VAD blood chamber with a reference to the classical method of analysing the cardioimpedance signal from the patient’s thorax. The paper also presents the results of determining stroke volume of blood chamber based on an empirical formula that has been developed.
Źródło:
Journal of Medical Informatics & Technologies; 2013, 22; 235-241
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies