Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Mikielewicz, Dariusz" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Development of ORC’s for micro power generation
Autorzy:
Mikielewicz, Jarosław
Mikielewicz, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/1191859.pdf
Data publikacji:
2018
Wydawca:
Gdańska Szkoła Wyższa
Tematy:
CHP
ORC
heat exchangers
heat transfer intensification
thermodynamics
Opis:
In the paper, new trends in development of micro power generation of heat and electricity are presented. New type of CHP for domestic usage is developed in the Institute of Fluid-Flow Machinery PAS and methods of its design are presented. The most promising trends in equipment of ORC cycle for this purpose were discussed. Main attention was focused on micro-heat exchangers design based on micro-channels and micro-jets. In our opinion future development of high power heat exchangers will be based on nets micro-heat exchangers.
Źródło:
Eco-Energetics: technologies, environment, law and economy; 2018, 1; 51--72
2657-5922
2657-7674
Pojawia się w:
Eco-Energetics: technologies, environment, law and economy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Challenges in operating and testing loop heat pipes in 500–700 K temperature ranges
Autorzy:
Szymański, Paweł
Mikielewicz, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/2091372.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
loop heat pipe
working fluid
material compatibility
Opis:
The potential applications of loop heat pipes (LHPs) are the nuclear power space systems, fuel cell thermal management systems, waste heat recovery systems, medium temperature electronic systems, medium temperature military systems, among others. Such applications usually operate in temperature ranges between 500–700 K, hence it is necessary to develop an LHP system that will meet this requirement. Such a thermal management device require to meet various technical problems and challenges currently existing in the development of LHP working in medium temperatures, including: (1) selection of appropriate working fluid; (2) selection of appropriate LHP construction material; (3) construction of suitable test rig capable of testing at elevated temperatures; (4) development of new testing methods. Currently, there are no proven working fluids that can be used in LHPs in medium temperature ranges. Water can be applicable only at temperatures up to 570 K. Caesium can be applicable at temperatures above 670 K. Organic fluids usually tend to generate non-condensable gasses and/or decompose at elevated temperatures and their viscosity dramatically increases. For halides, most of them are very reactive or toxic and their full property data are not available or the majority of the physical properties are predicted, also live tests and their environmental impact data are not adequate. As for casing/LHP construction material, there are no full chemical compatibility tables with most of the medium temperature working fluids and the reactivity of fluids significantly limits the potential materials. Also, testing such an LHP is an endeavour as the reactivity of medium temperature fluids and the use of obscure metals create new challenges. Altogether creates multiple challenges in the development, testing, handling and operating of LHP in the medium temperature range.
Źródło:
Archives of Thermodynamics; 2022, 43, 2; 61--73
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of cryogenic oxygen production unit with exhaust gas bleed for sewage sludge gasification and different oxygen purities
Autorzy:
Kaszuba, Maja
Ziółkowski, Paweł
Mikielewicz, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/27312208.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
thermodynamic analysis
oxy-combustion of syngas
BECCS
cryogenic air separation
penalty production
oxygen production
Opis:
The paper presents a thermodynamic analysis of the integration of a cryogenic air separation unit into a negative CO2 emission gas power plant. The power cycle utilizes sewage sludge as fuel so this system fits into the innovative idea of bioenergy with carbon capture and storage. A cryogenic air separation unit integrated with the power plant was simulated in professional plant engineering and thermodynamic process analysis software. Two cases of the thermodynamic cycle have been studied, namely with the exhaust bleed for fuel treatment and without it. The results of calculations indicate that the net efficiencies of the negative CO2 emission gas power plant reach 27.05% (combustion in 95.0% pure oxygen) and 24.57% (combustion in 99.5% pure oxygen) with the bleed. The efficiencies of the cycle without the bleed are 29.26% and 27.0% for combustion in 95.0% pure oxygen and 99.5% pure oxygen, respectively. For the mentioned cycle, the calculated energy penalty of oxygen production was 0.235 MWh/kgO2 for the lower purity value. However, for higher purity namely 99.5%, the energy penalty of oxygen production for the thermodynamic cycle including the bleed and excluding the bleed was indicated 0.346 and 0.347 MWh/kgO2, respectively. Additionally, the analysis of the oxygen purity impact on the carbon dioxide purity at the end of the carbon capture and storage installation shows that for the case with the bleed, CO2 purities are 93.8% and 97.6%, and excluding the bleed they are 93.8% and 97.8%, for the mentioned oxygen purities respectively. Insertion of the cryogenic oxygen production installation is required as the considered gas power plant uses oxy-combustion to facilitate carbon capture and storage method.
Źródło:
Archives of Thermodynamics; 2023, 44, 3; 63--81
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computational fluid dynamics simulation of heat transfer from densely packed gold nanoparticles to isotropic media
Autorzy:
Radomski, Piotr
Ziółkowski, Paweł
de Sio, Luciano
Mikielewicz, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/1954995.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer
gold nanoparticles
glasses
polymers
computational fluid dynamics
Opis:
This work aims to determine and compare heat generation and propagation of densely packed gold nanoparticles (Au NPs) induced by a resonant laser beam (532 nm) according to the Mie theory. The heat flux propagation is transferred into the materials, which here are: silica glass; soda-lime-silica glass; borosilicate glass; polymethyl methacrylate (PMMA); polycarbonate (PC); and polydimetylosiloxane (PDMS). This analysis aims to select the optimum material serving as a base for using photo-thermoablation. On the other hand, research focused only on Newtonian heat transfer in gold, not on non-Fourier ones, like the Cattaneo approach. As a simulation tool, a computational fluid dynamics code with the second-order upwind algorithm is selected. Results reveal a near-Gaussian and Gaussian temperature distribution profile during the heating and cooling processes, respectively. Dependence between the maximum temperature after irradiation and the glass thermal conductivity is observed confirming the Fourier law. Due to the maximum heating area, the borosilicate or soda-lime glass, which serves as a base, shall represent an excellent candidate for future experiments.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 87-113
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies