Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Malers, J." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Model water disinfection with electrolysis using TinO2n-1 containing ceramic electrodes
Autorzy:
Reimanis, M.
Mezule, L.
Malers, J.
Ozolins, J.
Juhna, T.
Powiązania:
https://bibliotekanauki.pl/articles/363148.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
chlor
dezynfekcja
elektroliza
Escherichia coli
chlorine
disinfection
electrolysis
Opis:
Water treatment with electrolysis was performed in a specially made electrolytic cell containing TinO2n-1 ceramic anode and Escherichia coli was used as a model organism for disinfection tests. The results showed that even relatively low energy input (0.5-2.5kWh*m-3, depending on water conductivity) in water samples with chloride ions concentration below 50mg*l-1, TinO2n-1 ceramic electrodes generated active chlorine in the range of 0.4-3.5mg Cl2*l-1, which is the level of chorine used for water disinfection. The results also confirmed that disinfection effect is a result of generation of oxidant species from chlorine rather than effect of electricity per se, or formation of radicals in water. At chloride ion concentration about 7mg*l-1 E. coli is not culturable, not able to divide and not respiring. Results showed that increase of the current above 0.02A at chloride ion concentration of 7mg*l-1 was sufficient to inactivate both culturable and viable but nonculturable (VBNC) E. coli. Notably, the ability of bacteria to divide (DVC positive) was lost more rapidly than their ability to respire. Kinetics of disinfection was studied in water sample which was treated with 0.02A at chloride ion concentration of 7mg*l-1. After about 15 minutes of exposure no culturable or able-to-divide E. coli were detected in the sample. Using the TinO2n-1 electrode in the electrolysis process with the presence of chloride ions, in concentration range which is common in raw waters, one can create a level of active chlorine that kills more than 99% of E. coli within 15 minutes. A practically applicable simple model for prediction of disinfection efficacy with electrolytic cell has been proposed.
Źródło:
Environmental Biotechnology; 2011, 7, 1; 34-40
1734-4964
Pojawia się w:
Environmental Biotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies