Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Malarski, Maciej" wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Purpose of the housing double stage polypropylene-carbon cartridges filters usage in bath gray water treatment
Autorzy:
Malarski, Maciej
Kalenik, Marek
Powiązania:
https://bibliotekanauki.pl/articles/118764.pdf
Data publikacji:
2020
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
gray water
filtration
cartridge filter
water
wastewater quality
gray water turbidity
Opis:
Bath gray water organoleptically did not appear to be significantly contaminated liquid. However, in order to re-use them, they need proper treatment. When recirculated in a household, they cannot pose a threat to human life. Based on their appearance, it seems that the solution to the problem is the use of cartridges filter. The article presents the results of the filtration of gray water from the bath through the filtration system with a housing double stage polypropylene-carbon filter FCCA-STO and to determine the impact of individual filter layers on wastewater treatment, tests were carried out on a single polypropylene FCPS10 and carbon FCCA filtration cartridge. The aim of the study was to determine the suitability of the selected housing filter cartridges for the treatment of bathing gray water for their reuse. For the tests were used natural bathing gray water from a two-family building inhabited by seven people. Wastewater were fed to the filter with a constant flow rate of 0.1 dm3·s–1. The assessment of the work of the filters based on parameters such as: COD, BOD5, suspension, dry residue, decay and turbidity. The conducted tests have shown a slight improvement in most of the quality parameters of gray water after filtration through selected housing cartridge filters. Only for turbidity, the reduction in the value of the pollution indicator was noticeable. The cartridge filters used in tests, acted like ordinary mechanical filtration cartridges. For the considered gray water, the use of analyzed cartridge filters can only be used for their initial purification.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2020, 29, 2; 244-258
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of sediment precipitation containing struvite from aqueous solutions on the inner walls of steel pipelines
Modelowanie wytrącania osadów zawierających struwity z roztworów wodnych na wewnętrznych ścianach rurociągów stalowych
Autorzy:
Czajkowska, Justyna
Malarski, Maciej
Siwiec, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/205099.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
modelling
crystallization
struvite
modelowanie
krystalizacja
struwit
Opis:
The complexity and uncontrolled formation of struvite (MgNH4PO4·6H2O) and its deposition in the technological equipment of wastewater treatment plants (WWTPs) are still the subject of research aimed at understanding the causes and proposing a remedial action. In order to reduce the intensity of the precipitation of struvite in wastewater treatment plants, it is recommended, among others, to limit flow velocity to below 1.5 m·s-1. Literature analysis showed that there are no studies on the precipitation of struvite deposits in pipelines. Most studies focus on the deliberate precipitation of struvite, for example phosphorus recovery, resulting in a molar ratio of 1:1:1 (NH4+:PO4 3-:Mg2+). In fact, in WWTPs, such concentrations do not occur, but there have been cases of the precipitation of this mineral (and its mixtures) in the sludge parts. In this paper, the study aimed at determining conditions for the precipitation of deposits with a significant participation of struvite on the inner walls of steel pipes. The study was conducted at a non-stoichiometric concentration of ingredients at different pH values, as well as under dynamic conditions with flow velocity below 1.5 m·s-1. A mathematical formula (ANOVA) that can be used to determine the mass of deposits in relation to the concentration of ammonium, phosphate, pH and flow velocity was developed. Computational models were developed on to investigate struvite precipitation under different pH levels (8.0–9.5) and ionic concentrations. The studies were carried out on solutions containing ammonium (NH4 +), phosphate (PO4 3-), and magnesium (Mg2+), at a flow velocities of 0.4, 0.9 and 1.4 m·s-1. In order to determine the mathematical formula thanks to which the mass of precipitates can be determined, a special pilot study installation was constructed. The XPS surface analysis of sludge from sewage treatment plants showed a similar composition of compounds with sediments obtained in own research. The presence of struvite was suggested, but the share of atomic percentage of bonds to which struvite was classified is small and amounts to less than 4%. This means that sediments precipitated in the technological installations are a mixture of various compounds of which pure struvite may constitute only a small part.
Złożoność i niekontrolowane powstawanie struwitu (MgNH4PO4·62O) oraz jego osadzanie w urządzeniach technologicznych oczyszczalni ścieków jest nadal przedmiotem badań mających na celu zrozumienie przyczyn i zaproponowanie działań zaradczych. W celu zmniejszenia intensywności wytrącania struwitu w oczyszczalniach ścieków zalecano między innymi ograniczenie prędkości przepływu poniżej 1,5 m·s-1. Analiza literatury wykazała, że nie ma badań dotyczących wytrącania struwitu w rurociągach stalowych. Większość badań koncentruje się na umyślnym wytrącaniu struwitu, na przykład w celu odzysku fosforu, doprowadzając do stosunku molowego 1:1:1 (NH4:PO4:Mg). W rzeczywistości w oczyszczalniach ścieków takie stężenia nie występują, ale zdarzały się przypadki wytrącania tego minerału (i jego mieszanin) w częściach osadowych. W pracy podjęto próbę określenia warunków występowania osadów z udziałem struwitu na wewnętrznych ścianach rur stalowych. Badanie przeprowadzono przy niestechiometrycznym stężeniu składników przy różnych wartościach pH, a także w warunkach dynamicznych z prędkością przepływu poniżej 1,5 m·s-1. Opracowano wzór matematyczny (ANOVA), który można wykorzystać do określenia masy osadów w zależności od stężenia amonu, fosforanu, pH i prędkości przepływu. Opracowano modele obliczeniowe do badania wytrącania struwitu i jego mieszanin przy różnych poziomach pH (8,0–9,5) i stężeniach jonowych. Badania prowadzono na roztworach zawierających jony, w tym amonu (NH4+), fosforanu (PO43-), magnezu (Mg2+) oraz prędkości przepływu (0,4; 0,9 i 1,4 m·s-1). Następnie wyznaczono formułę matematyczną w oparciu o badania wyzyskane w warunkach przepływowych na specjalnie skonstruowanej instalacji. Analiza powierzchniowe osadów mineralnych z oczyszczalni ścieków wykazała podobny skład z osadem uzyskanym w badaniach własnych. Sugerowano istnienie struwitu, ale procent udziału atomowego połączeń, do których sklasyfikowano struwite jest mały i wynosi mniej niż 4%. Oznacza to, że osady powstające w obiektach technologicznych oczyszczalni ścieków są mieszaniną różnych związków, w których czysty struwit może stanowić tylko niewielką część.
Źródło:
Archives of Environmental Protection; 2019, 45, 2; 22-30
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies