Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Machowski, J." wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
Selectivity of power system protections at power swings in power system
Selektywność działania zabezpieczeń w trakcie kołysań mocy w systemie elektroenergetycznym
Autorzy:
Machowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/397212.pdf
Data publikacji:
2012
Wydawca:
ENERGA
Tematy:
power system protection
power swings
selectivity
zabezpieczenia elektroenergetyczne
kołysania mocy
selektywność
Opis:
The paper discusses out-of-step protection systems such as: generator pole slip protections, out of step tripping protections, distance protections of step-up transformer, distance protections of transmission lines and transformers, power swing blocking, and special out-of-step protection. It is shown that all these protections make up a protection system, to which a setting concept uniform for the entire power system has to be applied. If a power system is inappropriately equipped with these protections, or their settings are inappropriate, they may operate unselectively, thus contributing to the development of power system blackouts. In the paper the concepts for a real power system are given for the two stages: target stage fully compliant with selectivity criteria, and transitional stage between the current and target stages.
W artykule omówiono zabezpieczenia związane z kołysaniami mocy, takie jak: zabezpieczenia generatorów od poślizgu biegunów, zabezpieczenia rozcinające od pracy asynchronicznej w sieci, zabezpieczenia odległościowe bloków generator-transformator, zabezpieczenia odległościowe linii przesyłowych i transformatorów, blokady kołysaniowe, automatyka przeciwkołysaniowa. Wykazano, że zabezpieczenia te stanowią łącznie system zabezpieczeń, wobec którego musi być stosowana koncepcja nastawień, jednolita dla całego systemu elektroenergetycznego. Przy nieodpowiednim wyposażaniu systemu elektroenergetycznego w te zabezpieczenia lub ich nieodpowiednim nastawianiu mogą one działać nieselektywnie, przyczyniając się do rozwoju awarii systemowych. Podano koncepcję dla dwóch etapów: etapu docelowego, spełniającego w pełni warunki selektywności, oraz etapu przejściowego między stanem aktualnym a docelowym.
Źródło:
Acta Energetica; 2012, 4; 96-123
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
WAMS - based control of series FACTS devices installed in tie-lines of interconnected power system
Autorzy:
Nogal, Ł.
Machowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/141396.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
system elektroenergetyczny
stabilność
FACTS
WAMS
power system control
transient stability
Opis:
This paper addresses the state-variable stabilising control of the power system using such series FACTS devices as TCPAR installed in the tie-line connecting control areas in an interconnected power system. This stabilising control is activated in the transient state and is supplementary with respect to the main steady-state control designed for power flow regulation. Stabilising control laws, proposed in this paper, have been derived for a linear multi-machine system model using direct Lyapunov method with the aim to maximise the rate of energy dissipation during power swings and therefore maximisation their damping. The proposed control strategy is executed by a multi-loop controller with frequency deviations in all control areas used as the input signals. Validity of the proposed state-variable control has been confirmed by modal analysis and by computer simulation for a multi-machine test system.
Źródło:
Archives of Electrical Engineering; 2010, 59, 3-4; 121-140
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
WAMS – based Control of Phase Angle Regulator Installed in Tie-lines of Interconnected Power System
Sterowanie tyrystorowych przesuwników kąta fazowego zainstalowanych w liniach powiązań międzysystemowych za pomocą sygnałów WAMS
Autorzy:
Nogal, Ł.
Machowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/396966.pdf
Data publikacji:
2012
Wydawca:
ENERGA
Tematy:
power system control
transient stability
FACTS
WAMS
regulacja systemu elektroenergetycznego
równowaga dynamiczna
Opis:
This paper addresses the state-variable stabilising control of the power system using such series FACTS devices as TCPAR installed in the tie-line connecting control areas in an interconnected power system. This stabilising control is activated in the transient state and is supplementary with respect to the main steady-state control designed for power fl ow regulation. Stabilising control laws, proposed in this paper, have been derived for a linear multi-machine system model using the direct Lyapunov method with the aim of maximising the rate of energy dissipation during power swings and therefore maximising their damping. The proposed control strategy is executed by a multi-loop controller with frequency deviations in all control areas used as the input signals. Validity of the proposed state-variable control has been confi rmed by modal analysis and by computer simulation for a multi-machine test system.
Tematem artykułu jest regulacja stabilizacyjna zmiennych stanu systemu elektroenergetycznego za pomocą urządzeń szeregowych FACTS typu TCPAR, zainstalowanych w liniach międzysystemowych łączących obszary regulacji w połączonym systemie elektroenergetycznym. Taką regulację stabilizacyjną uruchamia się w stanie przejściowym jako uzupełnienie głównej regulacji przepływu mocy w stanie ustalonym. Zaproponowane w niniejszym opracowaniu reguły regulacji stabilizacyjnej wyprowadzono dla liniowego modelu systemu wielomaszynowego, przy użyciu bezpośredniej metody Lapunowa, w celu maksymalizacji rozpraszania energii w trakcie kołysań mocy, a więc ich tłumienia. Proponowaną strategię regulacji wykonuje wielo-wejściowy układ regulacji wykorzystujący odchylenia częstotliwości we wszystkich obszarach regulacji jako sygnały wejściowe. Trafność proponowanej regulacji zmiennych stanu potwierdziła analiza modalna oraz symulacja komputerowa dla testowego systemu wielomaszynowego.
Źródło:
Acta Energetica; 2012, 3; 58-74
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low voltage, high-speed four-quadrant cmos transconductance multiplier
Niskonapięciowy szybki czteroćwiartkowy trans-konduktancyjny układ mnożący w technologii cmos
Autorzy:
Jasielski, J.
Kuta, S.
Machowski, W.
Kołodziejski, W.
Powiązania:
https://bibliotekanauki.pl/articles/389872.pdf
Data publikacji:
2010
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
analog VLSI
four-quadrant multiplier
CMOS
analogowe układy VLSI
czteroćwiartkowy układ mnożący
technologia CMOS
Opis:
The paper presents an analog four-quadrant transconductance multiplier designed in CMOS technology, suitable for low voltage and operating at high-speed. The transconductance multiplier with Gilbert-like architecture uses a cascade of a combination of two linear current dividers implemented by means of the differential pairs to produce a linear dependence between the tail current and the two output currents. To adopt the circuit for low voltage, simple current mirrors have been applied to couple the first- and the second stage of the current dividers cascade. High-speed operation is possible thanks to simple architecture of building blocks using RF CMOS transistors with sufficiently large biasing currents. A complete circuits schematic with input driving peripherials, as well as simulation results of entire multiplier have also been presented.
W artykule zaprezentowano szybki niskonapięciowy czteroćwiartkowy układ mnożący zaprojektowany w technologii CMOS. Architektura układu oparta jest o strukturę typu Gilberta. W układzie zastosowano kaskadowe połączenie dwóch stopni transkonduktancyjnych zrealizowanych w oparciu o pary różnicowe. Aby układ mógł pracować w zakresie niskich napięć zasilających poszczególne stopnie zostały sprzęgnięte przy pomocy prostych luster prądowych. Duża szybkość działania została osiągnięta dzięki prostej architekturze układu oraz zastosowaniu tranzystorów RF pracujących przy odpowiednio dużych wartościach prądów. W pracy zaprezentowano również wejściowe niskonapięciowe bloki pomocnicze oraz wyniki symulacji kompletnego układu mnożącego.
Źródło:
Zeszyty Naukowe. Telekomunikacja i Elektronika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy; 2010, 13; 115-124
1899-0088
Pojawia się w:
Zeszyty Naukowe. Telekomunikacja i Elektronika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Inverse Approach to Estimate Heat Transfer Coefficients of 122 mm Medium-Range Missile During Correction Engine Operation
Autorzy:
Zmywaczyk, J.
Koniorczyk, P.
Preiskorn, M.
Machowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/403855.pdf
Data publikacji:
2014
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
heat transfer
thermophysical properties
parameter estimation
R35 steel
heat transfer coefficient
Opis:
This paper presents an inverse approach to estimate the heat transfer coefficients on the inner and the outer sides of a cylindrical shield made of R35 steel containing a gas-dynamic control block of a 122 mm medium-range missile during the combustion of propulsion charge in a correction engine. The specific heat and the thermal diffusivity of R35 steel was experimentally determined using both Netzsch DSC 404F1 Pegasus and LFA 427 measuring devices, respectively. The obtained temperature characteristics of the thermo-physical parameters of cylindrical shield materials were then used to calculate the temperature field concerning the main problem. The inverse problem based on the parameter estimation method using Levenberg–Marquardt optimization procedure was applied to find the unknown heat transfer coefficients. To solve the inverse problem the temperature histories at some locations of the cylindrical shield were known from the experiment. For this purpose a test measuring stand was built and during the combustion process of the propulsion charge inside the cylindrical shield containing the correction engine the temperature distribution on the outer surface of the cylindrical shield was recorded by means of a high-speed infrared camera (PhantomV210). A two-dimensional axial-symmetric nonlinear heat conduction model which takes into account the heat loss due to convection and radiation was solved using the Finite Volume Method (FVM). It was found that the assumption of fixed heat transfer coefficients on both sides of the cylindrical shield was sufficient enough to achieve a satisfactory compliance between the measured and the calculated temperature histories at the same location.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2014, 5, 1 (15); 25-39
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat Transfer Investigations in Thermally Activated Battery : Experimental and Numerical Studies
Autorzy:
Preiskorn, M.
Koniorczyk, P.
Zmywaczyk, J.
Machowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/403895.pdf
Data publikacji:
2012
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
materials engineering
measurement of temperature
thermally activated battery
Opis:
In this paper both experimental and numerical studies of heat transfer in thermally activated batteries deriving from chemical sources of electric currents are considered. These batteries are used to supply special devices in the army, i.e. Missiles, rockets and they are characterized by the activation time from 0.1 s to several seconds with an effective working time from seconds, to tens of minutes [1]. The heat being generated during their work inside the battery causes a temperature increase of up to 873 K. In the frame of this work both experimental and numerical investigations of temperature distribution on the outer surface of the thermally activated battery BTR-03, as well as the heat flux distribution were carried out [8]. Comparing the temperature histories at several points on the outer surface of the battery BTR-03, obtained from experiment and calculated numerically allowed to validate the numerical model of heat transfer in the battery.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2012, 3, 3 (9); 17-27
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potential source rocks in the Ropianka Formation of the Magura Nappe (Outer Carpathians, Poland) – geochemical and foraminiferal case study
Autorzy:
Waśkowska, A.
Golonka, J.
Machowski, G.
Pstrucha, E.
Powiązania:
https://bibliotekanauki.pl/articles/184687.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
organic-rich deposits
geochemistry
foraminifera
Magura Nappe
shale-gas
Opis:
To optimize exploration for new hydrocarbon accumulations in the Polish Outer Carpathians, it is necessary to concentrate attention on identification of hydrocarbon accumulations of the “shale-gas” type. Results of recently completed analysis suggested new such possible targets in the Magura Basin, preserved in the Outer Carpathian Magura Nappe. Analysis of the preliminary results of paleoenvironmental and geochemical studies of these shales is the subject of this paper. Micropaleontological and geochemical study was conducted on the 300 m thick Świątkowa Member, the uppermost part of the Ropianka Formation located in the external, northernmost Siary Zone. This member is composed of thin- and medium-bedded sandstones interbedded by green, brown, black and dark-gray shales. Poor and changeable oxygenation is reflected in the composition of foraminiferal assemblages. A negative correlation between the TOC content and numbers and diversity of foraminifera is observed. The paleogeographic position and paleoenvironment assessment indicates that the Siary Zone fulfills certain conditions for organic productivity and preservation during the deposition of the Ropianka Formation.
Źródło:
Geology, Geophysics and Environment; 2018, 44, 1; 49-68
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fast Low Voltage Analog Four-Quadrant Multipliers Based on CMOS Inverters
Autorzy:
Machowski, W.
Kuta, S.
Jasielski, J.
Kołodziejski, W.
Powiązania:
https://bibliotekanauki.pl/articles/226683.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analog VLSI
four-quadrant multiplier
CMOS circuits
low voltage circuits
Opis:
The paper presents quarter-square analog four-quadrant multipliers, based on proprietary architecture using four CMOS inverters. The most important upgrade on already published own circuit implementation is the use of the same inverter "core" of the circuit with completely redesigned auxiliary and steering blocks. Two variants of new driving peripherals are considered: one with differential pair, the second with CMOS inverters. The proposed circuit solutions are suitable for RF applications in communication systems due to simple architecture comprising building blocks with RF CMOS transistors having sufficiently large biasing currents. Postlayout simulation results done on the basis of 180nm CMOS UMC Foundry Design Kit are also presented.
Źródło:
International Journal of Electronics and Telecommunications; 2010, 56, 4; 381-386
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface geochemical anomalies in the vicinity of the Wańkowa Oil Field (SE Polish Carpathians)
Autorzy:
Sechman, H.
Kuśmierek, J.
Machowski, G.
Guzy, P.
Dzieniewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/191525.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Geologiczne
Tematy:
surface geochemical survey
soil gas
light hydrocarbons
oil traps
Skole Nappe
Outer Carpathians
Polska
Opis:
The oil accumulations discovered in the Skole Synclinorium (eastern part of Polish Outer Carpathians) are located in zones of pinch-out of the Kliva Sandstone. An example is the Wańkowa Oil Field, which contains the largest oil reserves in the region. As the seismic identification of this type of hydrocarbon trap is ambiguous, a surface geochemical survey was carried out in the vicinity of the Wańkowa Oil Field along an experimental line perpendicular to the fold axes. A traverse across the zones with anomalous seismic records indicated the presence of undiscovered lithological traps. During the surface geochemical survey, 94 samples of soil gas were collected from a depth of 1.2 m and then investigated chromatographically. The spacing of sampling sites was 100 m, which was reduced to 50 m in the Wańkowa Oil Field area. The maximum concentrations of CH4 and total alkanes C2-C5 detected in samples were: 4250.0 ppm (0.425 vol. %) and 0.43 ppm, respectively. The first of these was detected at measurement point no. 86, located over the Wańkowa Field and the second at point no. 59, about 1,300 m south of the Wańkowa Field. The chemical analyses also detected maximum values of total alkenes C2-C4, H2 and CO2: 0.147 ppm, 0.042 vol. % and 4.4 vol. %, respectively. The results of the surface geochemical survey were integrated with observations on subsurface geological structures, which were interpreted on the basis of seismic data. This procedure permitted the documentation of anomalous concentrations of alkanes in the near-surface zone and contributed to an understanding of the tectonics of the hydrocarbon reservoirs in depth. The pattern of geochemical anomalies here is controlled by anticlines made up of Early Oligocene–Paleocene sediments and by overthrusts that displace these structures. The hydrocarbons migrated from condensate and/or oil accumulations located at various depths. The character of the anomalous zone discovered over the Wańkowa Oil Field is related to the effective sealing of hydrocarbon traps and/or the relatively low pressure caused by the production of oil for 130 years. However, this anomaly also may be the result of hydrocarbon migration from deeper, as yet undiscovered gas or gas-condensate accumulations, hosted in older reservoirs forming the hinge of the Ropienka-Łodyna Mine Anticline. The most pronounced anomalies were detected over the Wańkowa Village - Bandrów and Grabownica-Załuż anticlines. The active hydrocarbon dispersion in this zone may have resulted from the presence of overthrusts displacing the structures. Moreover, these anomalies may indicate the presence of shallow, maybe poorly sealed hydrocarbon accumulations.
Źródło:
Annales Societatis Geologorum Poloniae; 2016, 86, 2; 219-235
0208-9068
Pojawia się w:
Annales Societatis Geologorum Poloniae
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies