Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kupka, A. M." wg kryterium: Autor


Tytuł:
The influence of isothermal oxidation parameters on the tribological properties of titanium
Wpływ parametrów utleniania izotermicznego na właściwości tribologiczne tytanu
Autorzy:
Aniołek, K.
Barylski, A.
Kupka, M.
Dworak, M.
Powiązania:
https://bibliotekanauki.pl/articles/190879.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
titanium
thermal oxidation
oxide layers
tribological properties
tytan
utlenianie termiczne
warstwy tlenkowe
właściwości tribologiczne
Opis:
The paper presents the results of tests concerning the tribological properties of titanium Grade 2 subjected to thermal oxidation at a temperature of 600°C and 700°C for 72 hours. The morphology of the obtained oxide scale was determined using a scanning electron microscope. After oxidation at 600°C, the resultant oxides concentrated mostly on the roughness elevations formed during the grinding of samples. On raising the temperature to 700°C, finer and more agglomerated oxide particles were formed. Tribological tests have shown that titanium Grade 2 in a non-oxidised condition is characterised by very poor resistance to sliding wear. It has been found that the presence of an oxide layer on the surface of titanium significantly improves its poor tribological properties. Oxide layers obtained at temperatures of 600°C and 700°C allowed obtaining as much as a triple reduction of volumetric wear. Analysis of the morphology of the wear trace surface has shown the presence of corrugation wear on a non-oxidised specimen in the form of two alternate regions with different morphologies. It has been demonstrated that oxide layers obtained during thermal oxidation eliminate the phenomenon of corrugation wear.
W pracy przedstawiono wyniki badań dotyczące właściwości tribologicznych tytanu Grade 2 poddanego procesowi utleniania termicznego w temperaturze 600 i 700°C w czasie 72 h. Na skaningowym mikroskopie elektronowym określono morfologię otrzymanej zgorzeliny tlenkowej. Po utlenianiu w temperaturze 600°C powstałe tlenki koncentrowały się głównie na wzniesieniach nierówności powstałych w trakcie procesu szlifowania próbek. Podwyższenie temperatury do 700°C prowadziło do powstawania drobniejszych, skupionych cząstek tlenków. Badania tribologiczne wykazały, że tytan Grade 2 w stanie nieutlenionym charakteryzuje się bardzo słabą odpornością na zużycie ścierne. Stwierdzono, że obecność warstwy tlenkowej na powierzchni tytanu w sposób znaczący poprawia jego słabe właściwości tribologiczne. Warstwy tlenkowe otrzymane w temperaturze 600 i 700°C pozwoliły uzyskać redukcję zużycia objętościowego nawet 3-krotnie. Badania morfologii powierzchni śladów wytarcia wykazały występowanie zużycia falistego na próbce nieutlenionej w postaci dwóch naprzemianległych obszarów o różnej morfologii. Wykazano, że warstwy tlenkowe uzyskane w procesie utleniania termicznego skutecznie eliminują zjawisko zużycia falistego.
Źródło:
Tribologia; 2017, 274, 4; 5-9
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of load on the tribological properties of magnesium alloy WE54 after precipitation hardening
Wpływ obciążenia na właściwości tribologiczne stopu magnezu WE54 po utwardzaniu wydzieleniowym
Autorzy:
Barylski, A.
Aniołek, K.
Kupka, M.
Dworak, M.
Powiązania:
https://bibliotekanauki.pl/articles/189341.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
WE54
solution treatment
ageing
hardness
wear
przesycanie
starzenie
zużycie
Opis:
The paper presents the effect of precipitation hardening on the mechanical and tribological properties of magnesium alloy WE54. Mechanical tests have shown that the hardness and Young’s modulus of the alloy increased as the ageing time became longer. Improvement of the mechanical properties had a direct influence on the tribological properties. Tribological tests were performed on a ball-on-disk tribometer, applying variable loads of 2, 5, and 10 N. In the tests, a more than fourfold decrease in the specific wear rate, a threefold reduction in the linear wear, and a ca. 20% reduction of the friction coefficient were observed. The best results were obtained for ageing time of 24 h. The extension of the heat treatment time to 48h caused overageing of the alloy, which resulted in the deterioration of its mechanical and tribological properties.
W artykule przedstawiono wpływ utwardzania wydzieleniowego na właściwości mechaniczne i tribologiczne stopu magnezu WE54. Badania mechaniczne wykazały, że wraz ze wzrostem czasu starzenia rosła twardość i moduł Younga stopu. Poprawa właściwości mechanicznych miała bezpośredni wpływ na właściwości tribologiczne. Badania tribologiczne przeprowadzono na stanowisku ball-on-disk, zastosowano zmienne obciążenie (2, 5 i 10 N). Na podstawie przeprowadzonych badań stwierdzono ponad 4-krotne obniżenie specific wear rate, 3-krotne ograniczenie zużycia liniowego i ok. 20% spadek współczynnika tarcia. Najkorzystniejsze wyniki uzyskano dla czasu starzenia 24 h. Wydłużenie czasu obróbki cieplnej do 48 h powodowało przestarzenie stopu, co skutkowało pogorszeniem właściwości mechanicznych i tribologicznych.
Źródło:
Tribologia; 2017, 274, 4; 11-15
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical and tribological properties of oxide layers obtained on Ti-6Al-7Nb alloy
Właściwości mechaniczne i tribologiczne warstw tlenkowych otrzymanych na stopie Ti-6Al-7Nb
Autorzy:
Aniołek, K.
Barylski, A.
Kupka, M.
Dworak, M.
Powiązania:
https://bibliotekanauki.pl/articles/189500.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
titanium alloy
thermal oxidation
oxide layers
hardness
tribological properties
stop tytanu
utlenianie chemiczne
warstwy tlenkowe
twardość
właściwości tribologiczne
Opis:
The research presented in the paper was focused on determining the effects of thermal oxidation parameters on the mechanical and tribological properties of oxide layers formed on Ti-6Al-7Nb titanium alloy for biomedical applications. Titanium alloy was oxidized at 600 and 700°C for 72h. The study found that, at lower temperatures, the oxidized alloy surface was covered by a nonuniform oxide layer. A 100°C increase in the treatment temperature yielded a uniform layer covering the whole surface of the alloy. Hardness measurements showed that thermal oxidation resulted in the formation of oxide layers characterized by a 3-fold higher hardness compared to untreated alloy. Tribological tests showed that thermal oxidation effectively improves the resistance of Ti-6Al-7Nb alloy to sliding wear. Tribological tests demonstrated that an increased oxidation temperature was associated with improved resistance to sliding wear.
Przedstawione w pracy badania koncentrują się nad określeniem wpływu parametrów utleniania termicznego na właściwości mechaniczne i tribologiczne warstw tlenkowych otrzymanych na biomedycznym stopie tytanu Ti-6Al-7Nb. Proces utleniania termicznego przeprowadzono w temperaturze 600 i 700°C w czasie 72 h. Stwierdzono, że w niższej temperaturze utleniania powierzchnia stopu była pokryta nierównomiernie warstwą tlenkową. Podwyższenie temperatury utleniania termicznego o 100°C pozwoliło uzyskać jednolitą warstwę, w całości pokrywającą powierzchnię stopu. Pomiary twardości wykazały, że proces utleniania termicznego umożliwił otrzymanie warstw tlenkowych charakteryzujących się 3-krotnie wyższą twardością w porównaniu z twardością stopu niepoddanego utlenianiu. Badania tribologiczne wykazały, że utlenianie termiczne stanowi skuteczną metodę poprawy odporności na zużycie ścierne stopu Ti-6Al-7Nb. W testach tribologicznych wykazano, że wraz ze wzrostem temperatury utleniania odporność na zużycie ścierne ulegała zwiększeniu.
Źródło:
Tribologia; 2016, 267, 3; 9-17
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristic of Oxide Layers Obtained on Titanium in the Process of Thermal Oxidation
Autorzy:
Aniołek, K.
Kupka, M.
Barylski, A.
Mieszczak, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/354531.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
titanium
oxidation
scale
structure
hardness
Opis:
Thermal oxidation in air may be one method to improve the properties of titanium and its alloys through its influence on the structure and properties of the material’s surface layer. This paper presents a description of oxide layers obtained on the surface of Grade 2 titanium as a result of oxidation at temperatures of 600 and 700°C. On the basis of kinetic curves, it was found that the intensity of oxide layer growth increased with oxidation temperature. Studies of the surface morphology of oxide layers showed that the size of the formed oxide particles was greater following oxidation at 600°C. The obtained layers were subjected to X-ray phase analysis and microhardness measurements. Irrespective of oxidation temperature, the scale consisted of TiO2 oxide in the crystallographic form of rutile and of Ti3O oxide. The hardness of oxide layers amounted to around 1265 HV and was more than 4 times higher compared to the material in i ts initial state.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 853-856
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of irradiation with an electron beam on mechanical, sclerometric, and tribological properties of PTFE with a graphite additive
Wpływ napromieniowania strumieniem elektronów na właściwości mechaniczne, sklerometryczne i tribologiczne PTFE z dodatkiem grafitu
Autorzy:
Barylski, A.
Kaptacz, S.
Aniołek, K.
Kupka, M.
Powiązania:
https://bibliotekanauki.pl/articles/188212.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
PTFE
modification with an electron beam
mechanical properties
wear
modyfikacja strumieniem elektronów
właściwości mechaniczne
zużycie
Opis:
Polytetrafluoroethylene (PTFE) with a 15% graphite additive was subjected to irradiation using an electron beam of energy of 10 MeV in doses of 26, 52, 78, 104, and 156 kGy. The effect of electron beam irradiation on the mechanical, sclerometric, and tribological properties of the material was examined. It was found that the modification through irradiation entailed a gradual increase in the microhardness and Young's modulus as the absorbed dose of irradiation increased. A stereometric analysis of the scratch traces on the material allowed for the determination of the coefficients of the wear micromechanism, β, and resistance to wear, Wβ. After irradiation (especially with a dose of 104 kGy), a significant quantity of the material showed traces of ploughing; the value of the wear resistance coefficient Wβ for the PTFE subjected to cross-linking also increased considerably, which indicated a significant reduction of the tribological wear in relation to the initial material. Examination of abrasive wear of PTFE was performed for the polymer in its initial state and after modification through radiation on a pin-on-disc test stand, T-01. The tests have shown more than a five times reduction of the linear wear during the interaction with a titanium counter-specimen.
Politetrafluoroetylen z 15% dodatkiem grafitu poddano napromieniowaniu strumieniem elektronów o energii wiązki 10 MeV, w dawkach 26, 52, 78, 104, 156 kGy. Zbadano wpływ napromieniowania na właściwości mechaniczne, sklerometryczne i tribologiczne tworzywa. Stwierdzono, że modyfikacja radiacyjna powoduje stopniowe podwyższenie mikrotwardości oraz modułu Younga w miarę wzrostu pochłoniętej dawki napromieniowania. Stereometryczna analiza śladów zarysowania materiału umożliwiła wyznaczenie wskaźnika mikromechanizmu zużycia β i odporności na zużycie Wβ. Po napromieniowaniu (zwłaszcza dawką 104 kGy) znacząca ilość materiału ulega bruzdowaniu; silnie rosła także wartość wskaźnika odporności na zużycie Wβ PTFE poddanego sieciowaniu, co wskazywało na znaczne ograniczenie zużycia tribologicznego w stosunku do materiału wyjściowego. Badania zużycia ściernego politetrafluoroetylenu wykonano dla polimeru w stanie wyjściowym oraz po zmodyfikowaniu radiacyjnym na stanowisku T-01 w skojarzeniu trzpień–tarcza. Testy wykazały ponadpięciokrotne zmniejszenie zużycia liniowego podczas współpracy z tytanową przeciw-próbką.
Źródło:
Tribologia; 2016, 267, 3; 29-36
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
State-space averaging for maternal ECG suppression
Autorzy:
Kotas, M.
Jeżewski, J.
Kupka, T.
Matonia, A.
Powiązania:
https://bibliotekanauki.pl/articles/333145.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG płodu
detektor QRS
fetal ECG
QRS detector
dynamic time warping
embedding operation
Opis:
In this paper a new method of maternal electrocardiogram suppression for fetal component extraction from one-channel maternal abdominal bioelectric signals is proposed. The method performs maternal ECG estimation by application of state-space averaging. The estimated signal is subtracted from the original one and this way suppressed. The method parameters allow us to balance between the precision of maternal ECG suppression and the necessity not to attenuate the fetal QRS complexes. A small database of the maternal abdominal bioelectric signals is used to investigate the developed system for fetal heart rate determination. The final assessment is based on the detection performance index. It is shown that by proper choice of the parameters we can tune the system so that it is more effective than the classical approach based on template subtraction.
Źródło:
Journal of Medical Informatics & Technologies; 2009, 13; 194-200
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Separation of abdominal fetal electrocardiograms in twin pregnancy
Autorzy:
Kotas, M.
Jeżewski, J.
Matonia, A.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/333491.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
analiza składowych niezależnych
projekcyjne filtrowanie
EKG płodu
monitoring płodu
ciąża bliźniacza
independent component analysis
projective filtering
fetal ECG
fetal monitoring
twin pregnancy
Opis:
A combined application of independent component analysis and projective filtering of the time-aligned ECG beats is proposed to solve the problem of fetal ECG extraction from multi-channel maternal abdominal electric signals. The developed method is employed to process the four-channel abdominal signals recorded during twin pregnancy. The signals are complicated mixtures of the maternal ECG, the ECGs of the fetal twins and noise of other origin. The independent component analysis cannot separate the respective signals, but the proposed combination of the methods allows to suppress the maternal ECG and when the level of noise is low it leads to an effective separation of the twins' signals.
Źródło:
Journal of Medical Informatics & Technologies; 2008, 12; 83-89
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of instantaneous fetal heart rate extracted from abdominal and direct fetal electrocardiograms
Autorzy:
Matonia, A.
Kupka, T.
Jezewski, J.
Momot, A.
Jeżewski, M.
Bernys, M.
Powiązania:
https://bibliotekanauki.pl/articles/333262.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia płodu
tętno płodu
fetal monitoring
fetal electrocardiography
fetal heart rate
Opis:
This work is an attempt to assess the reliability of indirect abdominal electrocardiography as an alternative technique of fetal monitoring. As a reference signal we used the simultaneously acquired direct fetal electrocardiogram. Each recording consisted of four signals acquired from maternal abdomen and the reference signal acquired directly from fetal head. The first stage of our study concerned the signal loss episodes. In order to reduce the influence of incorrectly detected R-waves, some certain validation rules were applied. In the second stage, the corresponding intervals determined on basis of both acquisition methods were matched and the accuracy of fetal heart rate measurement was evaluated. Although the accuracy of abdominal electrocardiography turned out to be slightly lower than reported for ultrasound method, it still has some unique features deciding of its prevalence in a certain circumstances.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 19; 101-107
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal, mechanical, and tribological properties of PTFE composite with 20% graphite content irradiated with an electron beam
Właściwości termiczne, mechaniczne i tribologiczne kompozytu PTFE z 20% zawartością grafitu napromieniowanego strumieniem elektronów
Autorzy:
Barylski, A.
Kaptacz, S.
Skoneczny, W.
Kupka, M.
Aniołek, K.
Powiązania:
https://bibliotekanauki.pl/articles/190691.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
PTFE
radiation modification
thermal properties
wear
modyfikacja radiacyjna
właściwości termiczne
zużycie
Opis:
The paper investigated the effect of irradiation with an electron beam of energy 10 MeV in doses of 26–156 kGy on polytetrafluoroethylene with a 20% graphite additive. The tests have shown that changes in thermal properties of the composite (heat of crystallization, melting point, and degree of crystallinity) directly affected mechanical properties and contributed to the significant improvement of tribological properties. Tribological tests were performed on a pin-on-disc (T-01) test stand and counter-specimens were made of 1H18N9T steel. The load applied in the friction pair was 1 and 2 MPa (20 and 40 N). A nearly fourfold reduction in linear wear compared to the initial state for a load of 1 MPa has been shown. On the other hand, a more than 20-fold decrease in wear was found during tribological tests when the load was increased to 2 MPa. The most advantageous results were obtained for specimens irradiated with a dose of 104 kGy, and irradiation with a higher dose led to the degradation of the polymer and caused its wear to increase again. The obtained results hold promise for a significant improvement of the operational life of friction couples that do not require lubrication used, for example, in air compressors and engines, and for the possible application of thus modified polymers in nuclear and space industries.
W artykule zbadano wpływ napromieniowania strumieniem elektronów o energii 10 MeV i dawkach 26–156 kGy na politetrafluoroetylen z 20% dodatkiem grafitu. Badania wykazały, że zmiany właściwości termicznych kompozytu (ciepło krystalizacji, temperatura topnienia, stopień krystaliczności) miały bezpośredni wpływ na właściwości mechaniczne oraz znaczną poprawę właściwości tribologicznych. Badania tribologiczne przeprowadzono na stanowisku trzpień-tarcza (T-01) przeciwpróbki wykonano ze stali 1H18N9T. Nacisk w węźle tarcia wynosił 1 i 2 MPa (20 i 40 N). Wykazano blisko 4-krotne ograniczenie zużycia liniowego w porównaniu do stanu wyjściowego dla nacisku 1 MPa. Przy zwiększeniu nacisku do 2 MPa podczas badań tribologicznych stwierdzono natomiast ponad 20-krotne zmniejszenie zużycia. Najkorzystniejsze wyniki uzyskano dla próbek napromieniowanych dawką 104 kGy; napromieniowanie większą dawką prowadziło do degradacji polimeru i ponownego wzrostu zużycia. Otrzymane wyniki rokują na znaczną poprawę trwałości eksploatacyjnej węzłów tarcia niewymagających smarowania stosowanych np. w sprężarkach powietrza, silnikach, a także możliwość zastosowania tak zmodyfikowanych polimerów w przemyśle jądrowym oraz kosmicznym.
Źródło:
Tribologia; 2017, 274, 4; 17-20
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of Tribological Properties of Oxide Layers Obtained on Titanium in Different Friction Couples
Charakterystyka właściwości tribologicznych warstw tlenkowych otrzymanych na tytanie w różnych skojarzeniach ciernych
Autorzy:
Aniołek, K.
Barylski, A.
Kupka, M.
Kaptacz, S.
Czajerek, P.
Powiązania:
https://bibliotekanauki.pl/articles/190864.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
titanium
thermal oxidation
oxide layers
tribological properties
tytan
utlenianie termiczne
warstwy tlenkowe
właściwości tribologiczne
Opis:
The paper presents the characterization of tribological properties of titanium Grade 2 before and after isothermal oxidation in different friction couples. Examinations of the surface morphology after oxidation at a temperature of 600°C showed the presence of scratches on the surface, which indicated a low thickness of the oxide layers obtained. On the surface oxidized at 700°C, the morphology was characterized by the presence of small clusters of oxides which formed into shapes resembling flakes. In that case, no scratches were found, which testified to a higher thickness of the oxide layer. Tribological tests were conducted for different friction couples (Al2O3, ZrO2, and 100Cr6 balls). It was found that isothermal oxidation is an effective method to improve the resistance of titanium Grade 2 to sliding wear. Oxide layers obtained at temperatures of 600°C and 700°C allowed achieving a considerable reduction of volumetric wear. The best resistance to sliding wear was achieved during a tribological interaction of oxidized titanium Grade 2 with bearing steel 100Cr6. Examination of the morphology of the wear trace surface showed the presence of “corrugation wear” on the non-oxidized surface, regardless of the counter-specimen used. It was found that the presence of oxide layers on the surface of titanium Grade 2 effectively eliminated this adverse phenomenon.
W pracy przedstawiono charakterystykę właściwości tribologicznych tytanu Grade 2 przed i po utlenianiu izotermicznym w różnych skojarzeniach ciernych. Badania morfologii powierzchni po utlenianiu w temperaturze 600°C wykazały obecność rys na powierzchni, co świadczyło o niewielkiej grubości otrzymanych warstw tlenkowych. Na powierzchni utlenionej w temperaturze 700°C morfologia charakteryzowała się występowaniem drobnych skupisk tlenków uformowanych w kształty przypominające „płatki”. W tym przypadku nie stwierdzono obecności rys, co świadczyło o większej grubości warstwy tlenkowej. Badania tribologiczne realizowano w różnych skojarzeniach ciernych (kulki Al2O3, ZrO2 oraz 100Cr6). Stwierdzono, że utlenianie izotermiczne jest skuteczną metodą w zakresie poprawy odporności na zużycie ścierne tytanu Grade 2. Warstwy tlenkowe otrzymane w temperaturze 600 oraz 700°C pozwoliły uzyskać znaczą redukcję zużycia objętościowego. Najlepszą odporność na zużycie ścierne uzyskano podczas współpracy tribologicznej utlenionego tytanu Grade 2 ze stalą łożyskową 100Cr6. Badania morfologii powierzchni śladów zużycia wykazały na powierzchni nieutlenionej obecność tzw. zużycia falistego niezależnie od zastosowanej przeciwpróbki. Stwierdzono, że obecność warstw tlenkowych na powierzchni tytanu Grade 2 skutecznie eliminuje to niekorzystne zjawisko.
Źródło:
Tribologia; 2018, 278, 2; 5-11
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous recording and analysis of direct and indirect fetal electrocardiography
Autorzy:
Matonia, A.
Jeżewski, J.
Kupka, T.
Horoba, K.
Bernys, M.
Powiązania:
https://bibliotekanauki.pl/articles/333338.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG płodu
monitorowanie płodu
fetal electrocardiography
fetal monitoring
Opis:
Recording and analysis of fetal heart rate variability is still the most common method for detection of early symptoms of fetal hypoxia. However, fetal heart rate obtained via ultrasound describes only mechanical activity of fetus heart. Limitations of this technique have stimulated the development of fetal electrocardiography. It ensures more precise determination of fetal heart rate and, which is more important, enables assessment of the morphology of the fetal QRS complexes. In this paper two techniques of obtaining the fetal electrocardiogram are described and their comparative study is presented.
Źródło:
Journal of Medical Informatics & Technologies; 2004, 8; MM111-118
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Data stream processing in fetal monitoring system: II. Application to signal processing
Autorzy:
Jeżewski, J.
Widera, M.
Winiarczyk, R.
Matonia, A.
Kupka, T.
Gacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/334015.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
język zapytań
przetwarzanie strumienia danych
system zarządzania bazami danych
monitorowanie płodu
query language
data stream processing
database management system
fetal monitoring
Opis:
Fetal monitoring system belongs to signal processing system class. The main functions of the system are signal acquisition from bedside monitors, on-line trace analysis and dynamic presentation of incoming data. Collected data set is controlled by centralised application. Relational database management system cannot process samples of high frequency biomedical signals on-line. Therefore, we decide to build our own data management system dedicated to stream processing that support continuous query. This paper describes a method of building a query plan based on proposed algebra. The presented example of application enables implementation of algorithm determining long- and short-term indices for fetal heart rate variability assessment on the basis of declarative query language. Our solution enables to define query based on data streams that make the updated answers currently available.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT35-42
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indexing biomedical streams in data management system
Autorzy:
Widera, M.
Wróbel, J.
Matonia, A.
Jeżewski, M.
Horoba, K.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/333832.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
scentralizowane monitorowanie
przetwarzanie strumienia danych
indeksowanie
centralized monitoring
data stream processing
indexing
Opis:
We are developing Data Stream Management System that can be applied in medical monitoring system. One of the problems is how to support efficient data access methods. This paper considers indexing issues in data management system. The indexing is a commonly used method of data access acceleration. Classical and new streaming methods of indexing have been presented. The method was developed in data stream management system and first applied in a centralized neonatal monitoring system.
Źródło:
Journal of Medical Informatics & Technologies; 2005, 9; 107-112
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dimensional Changes, Microstructure, Microhardness Distributions And Corrosion Properties Of Iron And Iron-Manganese Sintered Materials
Zmiany wymiarowe, mikrostruktura, rozkład mikrotwardości i własności korozyjne spiekanych materiałów żelazo oraz żelazo-mangan
Autorzy:
Kupková, M.
Hrubovčáková, M.
Zeleňák, A.
Sułowski, M.
Ciaś, A.
Oriňáková, R.
Morovská Turoňová, P.
Žáková, K.
Kupka, M.
Powiązania:
https://bibliotekanauki.pl/articles/355524.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
powder metallurgy
iron
manganese
corrosion behaviour
dimensional changes
microhardness
metalurgia proszków
żelazo
mangan
odporność korozyjna
zmiany wymiarowe
mikrotwardość
Opis:
Iron samples and Fe-Mn alloys with Mn content of 25 wt.% and 30 wt.% were prepared by blending, compressing and sintering with the aim to study their dimensional changes, microstructure, microhardness distribution and primarily the electrochemical corrosion behaviour in a simulated body environment. The light microscopy (LM), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and micro-hardness measurements revealed a microheterogeneous multiphase structure of sintered Fe-Mn samples. The potentiodynamic tests have demonstrated that the corrosion rates of such Fe-Mn alloys immersed in Hank’s solution were higher than those for a pure iron, and also higher than the rates reported for homogeneous Fe-Mn alloys.
Próbki żelazne oraz stopy Fe-Mn, zawierające 25 i 30% mas. Mn, przeznaczone na biomateriały, zostały przygotowane na drodze mielenia, prasowania oraz spiekania w celu zbadania ich zmian wymiarowych, mikrostruktury, rozkładu mikrotwardości oraz odporności korozyjnej w skumulowanych w warunkach laboratoryjnych, panujących w ciele człowieka. Badania z wykorzystaniem mikroskopii optycznej i skaningowej, wraz z EDX oraz pomiary mikrotwardości ujawniły mikroniejednorodność wielofazowej struktury spiekanych stopów Fe-Mn. Testy potentiometryczne wykazały, że współczynniki korozji spieków Fe-Mn były wyższe niż spieków wykonanych z czystego żelaza oraz z jednorodnych stopów Fe-Mn.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 2A; 639-642
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of human fall episodes based on coordinates of body tags and numerical differentiation
Autorzy:
Momot, M.
Momot, A.
Nowak, G.
Seredynski, R.
Jezewski, J.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/333630.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
otoczenie
wspieranie życia
dane nieregularne objęte próbą
zróżniczkowanie numeryczne
ambient
assisted living
fall detection
irregular sampled data
numerical differentiation
Opis:
This paper presents a new method for detection of changes in alignment of the human body, particularly the fall, on the basis of signals acquired from the position sensors placed on the body of the monitored person. The sensors are located on the cuffs, waist and chest. Transformation of data sequence collected from sensors is proposed in order to best distinguish between the collapse from the normal movement. It is based on nonlinear combination of the first two derivatives of the signals being read. Because data from the sensors is sent asynchronously, a numerical algorithm for unevenly sampled data differentiation is proposed. Derivative values are calculated in equidistant nodes through differentiation of a polynomial, which is adjusted by minimizing the mean square error. The developed method can be used in home care telemedicine systems, where it is necessary to long term monitor of multiple vital parameters of people under care.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 21; 11-17
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies