Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gajewska, M. H." wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
The use of constructed wetlands for the treatment of industrial wastewater
Zastosowanie obiektów hydrofitowych do oczyszczania ścieków przemysłowych
Autorzy:
Skrzypiec, K.
Gajewska, M. H.
Powiązania:
https://bibliotekanauki.pl/articles/292531.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
constructed wetlands
industrial wastewater
organic matter
specific pollutants
wastewater treatment
materia organiczna
oczyszczalnie hydrofitowe
oczyszczanie ścieków
ścieki przemysłowe
zanieczyszczenia specyficzne
Opis:
Constructed wetlands are characterized by specific conditions enabling simultaneous various physical and biochemical processes. This is the result of specific environment for the growth of microorganisms and hydrophytes (aquatic and semiaquatic plants) which are capable of living in aerobic, anaerobic and facultative anaerobic conditions. Their interaction contributes to the intensification of oxidation and reduction responsible for the removal and retention of pollutants. These processes are supported by sorption, sedimentation and assimilation. Thanks to these advantages, treatment wetland systems have been used in communal management for over 50 years. In recent years, thanks to its advantages, low operational costs and high removal efficiency, there is growing interest in the use of constructed wetlands for the treatment or pre-treatment of various types of industrial wastewater. The study analyzes current use of these facilities for the treatment of industrial wastewater in the world. The conditions of use and efficiency of pollutants removal from readily and slowly biodegradable wastewater, with special emphasis on specific and characteristic pollutants of particular industries were presented. The use of subsurface horizontal flow beds for the treatment of industrial wastewater, among others from crude oil processing, paper production, food industry including wineries and distillery, olive oil production and coffee processing was described. In Poland constructed wetlands are used for the treatment of sewage and sludge from milk processing in pilot scale or for dewatering of sewage sludge produced in municipal wastewater treatment plant treating domestic sewage with approximately 40% share of wastewater from dairy and fish industry. In all cases, constructed wetlands provided an appropriate level of treatment and in addition the so-called ecosystem service.
W ostatnich latach rośnie zainteresowanie użyciem systemów hydrofitowych do oczyszczania lub wstępnego oczyszczania różnego rodzaju ścieków przemysłowych. W pracy zanalizowano aktualne wykorzystanie tych obiektów do oczyszczania ścieków przemysłowych na świecie. Przedstawiono warunki wykorzystania i skuteczności usuwania zanieczyszczeń łatwo i wolno biodegradowalnych, ze szczególnym naciskiem na zanieczyszczenia specyficzne poszczególnych gałęzi przemysłu. Opisano zastosowanie złóż z poziomym przepływem do oczyszczania ścieków między innymi z przeróbki ropy naftowej, produkcji papieru i przemysłu spożywczego. W Polsce obiekty hydrofitowe są wykorzystywane do oczyszczania ścieków i osadów z przetwórstwa mleka w skali pilotażowej lub do odwadniania osadów ściekowych wytwarzanych w oczyszczalni ścieków komunalnych z udziałem ścieków z przemysłu mleczarskiego i rybnego w wysokości 40%. We wszystkich przypadkach oczyszczalnie hydrofitowe zapewniły odpowiedni poziom usuwania zanieczyszczeń oraz tak zwany ecosystem service.
Źródło:
Journal of Water and Land Development; 2017, 34; 233-240
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational problems of constructed wetland for landfill leachate treatment: case study
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/125011.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
treatment wetland
landfill leachate
clogging
Opis:
The present paper discusses the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and the evaluation of a wetland system designed for treatment of the leachate. The research has been conducted during a 5-year period. The constructed wetland for leachate treatment was built in 2001; it consists of 2 horizontal subsurface flow reed beds, working in parallel. In the period 2005–2006 it underwent modernization due to unsatisfactory treatment results caused by bed clogging. After the modernization the treatment effectiveness is satisfactory. The effluent from bed I met Polish outflow standards, while in the effluent from bed II COD, total N and TSS exceeded the required concentrations. In spite of this, pretreatment of leachate (iron removal) should be quickly introduced to protect the system against the reoccurrence of clogging problems.
Źródło:
Journal of Ecological Engineering; 2013, 14, 3; 53-58
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of wastewater treatment in single-family constructed wetlands in Kaszuby Lake District
Skuteczność oczyszczania ścieków bytowych w przydomowych oczyszczalniach hydrofitowych na Pojezierzu Kaszubskim
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/1818796.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
skuteczność oczyszczania
przydomowe oczyszczalnie
pojezierze kaszubskie
Opis:
W pracy zaprezentowano wyniki badań trzech różnych konfiguracji oczyszczalni hydrofitowych stosowanych do oczyszczania ścieków bytowych z indywidualnych gospodarstw domowych. Wykazano, m.in., że zastosowanie oczyszczalni hydrofitowych jest zrównoważonym i stabilnym rozwiązaniem problemu gospodarowania ściekami na terenach o rozproszonej zabudowie. Oczyszczalnie przydomowe w Polsce otrzymują wyższe stężenia zanieczyszczeń niż odpowiednie oczyszczalnie w Europie czy USA, po mimo to analizowane obiekty zapewniały skuteczne usuwanie substancji organicznej: BZT5 do 92,0% i substancji biogennych: Nog do 77,0% i Pog do 66,0%. Konfiguracja II składająca się z dwóch charakteryzowała się najwyższą skutecznością usuwania zanieczyszczeń i w konsekwencji zapewniała najniższe stężenia zanieczyszczeń w oczyszczonych ściekach.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 81-95
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational problems of constructed wetland for landfill leachate treatment: case study
Problemy z eksploatacją systemów hydrofitowych dooczyszczania odcieków ze składowiska: studium przypadku
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/401274.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
system hydrofitowy
odciek ze składowiska
zatykanie się
treatment wetland
landfill leachate
clogging
Opis:
In the paper the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and evaluation of a wetland system designed for treatment of the leachate are discussed. The research has been conducted during the 5 years period. The constructed wetland for leachate treatment, consisting of 2 horizontal subsurface flow reed beds, working in parallel was built in 2001. In the period 2005-06 it underwent modernization due to unsatisfactory treatment results caused by clogging of the beds. The treatment effectiveness after modernization is satisfactory. The effluent from bed I met Polish outflow standards, while in the effluent from bed II COD, total N and TSS exceeded the required concentrations. In spite of this, pre-treatment of leachate (iron removal) should be quickly introduced to protect the system against the repetition of clogging problems.
Opisane w artykule badania prowadzono w okresie pięciu lat. System hydrofitowy zbudowany w 2001 roku do oczyszczania odcieków ze składowiska składa się z dwóch poziomych złóż o przepływie podpowierzchniowym, w układzie równoległym. W 2005-2006 roku wykonano modernizację układu ze względu na problem z zatykaniem się złóż. Efektywność oczyszczania po modernizacji jest zadowalająca, odpływ ze złoża I spełnia polskie normy, natomiast w przypadku złoża II zaobserwowano przekroczenia ChZT i zawiesiny ogólnej. W celu uniknięcia zatykania się złóż należy zastosować wstępne oczyszczanie odcieków.
Źródło:
Inżynieria Ekologiczna; 2011, 25; 202-210
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Eco-innovative Technologies of Nutrients Removal in Wastewater – Case Study BARITECH Project
Zastosowanie innowacyjnych technologii do usuwania związków biogennych ze ścieków – studium przypadku (BARITECH)
Autorzy:
Kasprzyk, M.
Pierzgalski, K.
Wojciechowska, E.
Obarska-Pempkowiak, H.
Gajewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/1813856.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
nitrogen removal
phosphorus removal
reject water
constructed wetlands
usuwanie azotu
usuwanie fosforu
odcieki
oczyszczalnie hydrofitowe
Opis:
Eco-innovative technologies in wastewater treatment should provide not only stringent standards for the quality of treated wastewater but also ensure maximum recovery of energy and raw materials from wastewater. One of the ways to improve the removal efficiency of nitrogen and phosphorus compounds in existing conventional wastewater treatment plants is pretreatment of reject water generated during the mechanical dewatering of the digested sewage sludge. The aim of this research was to select the technological parameters of processes to ensure effective removal of nutrient elements (N, P) from RW treated in a SBR reactor in the nitritation/anammox process. The study was divided into two stages. The first stage was carried out to optimize nitrogen compounds removal in the effluent from ANAMMOX process used to treat reject water after centrifugation. The installation consists of single vertical subsurface flow (VSSF) beds located in stainless steel containers working parallel marked as BED control “0”, “I”, “II”. Samples have been taken for analysis to determine the changes of NH4-N, NO3-N and NO2-N in the effluent of each filter. In bed “0” the removal of nitrogen compounds was caused only by sorption at last until its capacity was reached. In bed “I” and “II” the NH4-N concentration in effluent and production of NO2-N with simultaneous changes of NO3-N indicated that nitrification was occurring. The investigation has shown different pattern of processes responsible for nitrogen compounds transformation and removal efficiency, depending on the bed substrate and vegetation. In the second stage the optimization of phosphates removal was carried out. The investigation was conducted in steady conditions in laboratory model with four batch reactors. Each batch reactor of synthetic wastewater with given concentration of phosphates (15 mg/dm3) was subjected to mixing. Samples for analyzing were taken from each beaker after assumed time of sedimentation. Studies were conducted to determine the optimal dose of Phoslock® with known concentration of phosphate anions PO43- in model solution, time of mixing and time of sedimentation. Samples were analyzed with following parameters: pH, total suspended solids, conductivity, turbidity, color and phosphate concentration. The carried out investigations confirmed high efficiency of phosphate anions PO443- removal (over 95%). Also study showed no relationship between the mixing time and the degree of reduction of phosphorus compounds.
Innowacyjne technologie stosowane podczas oczyszczania ścieków powinny spełniać nie tylko wysokie wymagania dotyczące jakości oczyszczonych ścieków, ale także zapewnić maksymalny potencjał odzysku energii i surowców z ścieków. Jednym ze sposobów poprawy skuteczności usuwania związków azotu i fosforu w istniejących konwencjonalnych oczyszczalniach ścieków, jest wstępne oczyszczanie odcieków powstających podczas mechanicznego odwadniania osadu ściekowego po biologicznym oczyszczaniu ścieków. Celem badań było określenie charakterystycznych parametrów procesów technologicznych, dla zapewnienia skutecznego usuwania związków biogennych (N, P) ze ścieków po oczyszczaniu w procesie nitryfikacji/anammox zachodzącym w reaktorze typu SBR. Badanie zostało podzielone na dwa etapy. Pierwszy etap przeprowadzono w celu optymalizacji procesu usuwania związków azotu (NH4-N, NO3-N i NO2-N) z odcieków powstających z mechanicznego odwadniania przefermentowanych osadów ściekowych. Odcieki oczyszczane były w reaktorze SBR w procesie ANAMMOX. Instalacja pilotowa składała się z pojedynczych złóż o przepływie pionowym umieszczonych w zbiornikach ze stali nierdzewnej, pracujących równolegle oznaczonych odpowiednio jako złoże "0", "I", "II". Próbki do analizy pobierano w celu określenia zmian NH4-N, NO3-N i NO2-N w ściekach w każdym ze złóż. W złożu "0" (nie zasiedlonym trzciną) usuwanie związków azotu spowodowane było jedynie przed sorpcję, aż do wyczerpania jego pojemności sorpcyjnej. Natomiast zmiany stężenia NH4-N i wytwarzanie NO2-N przy jednoczesnych zmianach stężenia NO3-N wskazywały na zachodzący proces nitryfikacji w złożach "I" i "II" (oba zasiedlone trzciną). Doświadczenia wykazały różne mechanizmy procesów odpowiedzialnych za przemiany związków azotu i skuteczność ich usuwania, w zależności od podłoża i wegetacji. W drugim etapie badań przeprowadzono optymalizację procesu usuwania fosforanów. Natomiast doświadczenia związane z usuwaniem fosforu zostało przeprowadzone w laboratorium w warunkach nieprzepływowych przy zastosowaniu modelu z czterema reaktorami. Każdy reaktor zawierający ścieki syntetyczne o stężeniu fosforanów 15 mg/dm3 poddano mieszaniu. Próbki do analizy zostały pobierane z każdej zlewki po założonym czasie sedymentacji. Badania przeprowadzono w celu określenia optymalnej dawki preparatu Phoslock® przy znanym stężeniu anionów fosforanowych PO43- w roztworze modelowym, oraz znalezienia optymalnego czasu mieszania i sedymentacji. Próbki poddano analizie i określono następujące parametry: pH, zawiesinę, przewodnictwo, mętność, barwę i stężenie fosforanów. Przeprowadzone badania potwierdziły wysoką skuteczność usuwania PO43- (ponad 95%). Badanie nie wykazało zależności między czasem mieszania a stopniem redukcji związków fosforu.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 143-160
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sewage gardens – constructed wetlands for single family households
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Kołecka, K.
Powiązania:
https://bibliotekanauki.pl/articles/208217.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
przydomowa oczyszczalnia hydrofitowa
przydomowe oczyszczalnie
oczyszczanie hydrofitowe
roślinne oczyszczalnie ścieków
domy jednorodzinne
oczyszczanie ścieków
household sewage treatment wetland
household sewage
wetland treatment
treatment wetland (TWs)
wastewater treatment plant
single family
wastewater treatment
Opis:
During the last 30 years the increase of interest in low-cost decentralized and small wastewater treatment plants (WWTP) is observed in Europe. For this purpose, sand filters, stabilization ponds, mini reactors with activated sludge, trickling filters and treatment wetlands are used. Among the listed facilities, treatment wetlands (TWs) offer effective and reliable treatment efficiency, being at the same time low-cost and simple in operation. This is a sustainable treatment technology which does not generate secondary sewage sludge. In the paper, design concept and performance of nine TWs constructed in 2009 for single-family households in Kashubian Lake District is discussed. The treatment efficiency of three different TW configurations is compared. The findings of the study provide a basis for future design and implementation of TWs in agricultural areas.
Źródło:
Environment Protection Engineering; 2015, 41, 4; 71-82
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pre-Feasibility Study for Treatment Wetland Application for Wastewater Treatment in Dispersed Development
Autorzy:
Gajewska, M.
Kołecka, K.
Obarska-Pempkowiak, H.
Wojciechowska, E.
Ostojski, A.
Bejnarowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/124403.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater management in scattered development
conventional and natural treatment methods
economical cost
investment and maintenance costs
Opis:
The aim of the paper is to present the conducted analyses of pre-feasibility study of different approaches for wastewater management in a settlement of 180 persons. In the assessment both technical and economic aspects were analyzed. The costs were calculated for three different and, at the same time, most popular as well as possible technical solutions like: (i) construction of local wastewater treatment plant with gravitational and pressurized networks, (ii) construction of single family wastewater treatment plants, (iii) construction of sealed septic tanks. Carried out analyses of investment and maintenance costs revealed that at the stage of construction the most expensive is local sewer network with treatment plant, while the construction of a single family treatment plant has similar cost regardless of the technology used. When the long term operation and investment cost are accounted the most economical reasonable solution is the application of wetland treatment for household wastewater treatment.
Źródło:
Journal of Ecological Engineering; 2016, 17, 3; 79-86
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eptifibatide induced acute thrombocytopenia. Case report of 80- years old man with acute coronary syndrome
Autorzy:
Kuźma, Ł.
Pogorzelski, S.
Wróblewski, D.
Struniawski, K.
Róg-Makal, M.
Nowak, K.
Matys, U.
Gajewska-Bachórzewska, H.
Dobrzycki, S.
Powiązania:
https://bibliotekanauki.pl/articles/1918779.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Thrombocytopenia
glycoprotein IIb/ IIIa inhibitors
acute coronary syndrome
Opis:
Introduction: Glycoprotein (Gp) IIb/IIIa is a platelet receptor participating in platelet aggregation. According to ESC guidelines, glycoprotein IIb/IIIa inhibitors might be considered during percutaneous coronary interventions in patients with the acute coronary syndrome. Purpose: A case study of profound thrombocytopenia in 80-year-old man with the acute coronary syndrome. Case presentation: An 80-year-old, medicationnaive man with acute coronary syndrome was admitted to the Department of Invasive Cardiology. Due to the unsuccessful invasive strategy, an intracoronary bolus of Gp IIb/IIIa inhibitor – eptifibatide - was administered. During the following intravenous infusion, large subcutaneous hematomas were observed. Eptifibatide infusion was discontinued. Drop in platelet count to 1 thou/μL without significant anemia was registered. A control sample in sodium citrate showed similarly low platelet count - 2 thou/uL. Acetylsalicylic acid and clopidogrel were discontinued, steroids were introduced. Neither PLT nor FFP transfusion were necessary. Consecutive lab tests showed the gradual increase of PLT up to 35 thou/μL at discharge. A week later, the patient did not complain of any cardiovascular or bleeding symptoms; hematomas resented significant involution. Laboratory findings were normal. During follow-up visit 30 days after the discharge, the patient presented no cardiovascular symptoms. Conclusions: There are patients at risk of druginduced thrombocytopenia, especially those with impaired kidney function and the elderly. In such cases, decisions concerning anti-platelet and antithrombotic therapy should be taken cautiously. Because of its rare occurrence, every case of severe thrombocytopenia in ACS patients should be reported. Moreover, such patients should be followed-up to minimalize risk of similar adverse events in the future.
Źródło:
Progress in Health Sciences; 2018, 8(2); 234-238
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies