Tytuł:
Intrarater reliability of the Foot Posture Index (FPI-6) applied as a tool in foot assessment in children and adolescents
Foot Posture Index (FPI-6) w badaniu stóp u dzieci i młodzieży – rzetelność testu powtarzanego przez tego samego badającego
Autorzy:
Oleksy, Łukasz
Mika, Anna
Łukomska-Górny, Anna
Marchewka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1957149.pdf
Data publikacji:
2010
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
Foot
children
adolescents
assessment
test
FPI-6
Reliability
stopa
dzieci
młodzież
badanie
rzetelność
Opis:
Background: The evaluation of proper foot posture is of importance in diagnosis. All abnormalities in the foot structure may reflect the pathogenesis of the dysfunctions presented at other parts of the body. There are many diagnostic devices for foot assessment, but the results obtained using different methods are often not comparable. Foot Posture Index (FPI-6) was created as a quick, simple and reliable tool for quantifying foot posture in a variety of clinical settings.Aim: The evaluation of foot posture in 3 age groups of children using FPI-6 and the assessment of the reliability of this methodMaterial and Methods: 60 subjects in 3 age groups 9, 12 and 14 years participated in the study. For the purpose of FPI-6 reliability level determination all measurements were taken twice, with a 2-week gap. The following variables were evaluated: body height, body mass, BMI (Body Mass Index), the foot assessment using FPI-6.Results: The correlation coefficient R between the first and second measurement for all criterion was 0.89-0.96, what indicates a very good FPI-6 reliability in the foot assessment. Both the inversion/eversion of the calcaneus and abduction/adduction of the forefoot on the rear foot in the groups of 9- and 12-year-old children indicated mild foot pronation, and those parameters changed significantly in 14-year-old children where values were reached typical for a neutral foot.Conclusion: FPI-6 it is a simple and reliable tool for comprehensive foot evaluation, which allows one to use it both in clinical practice as in preventive population based studies.
Wstęp: Ocena prawidłowego ukształtowania stóp ma bardzo istotne znaczenie diagnostyczne. Wszelkie odchylenia w ich budowie mają odzwierciedlenie w patogenezie schorzeń w obrębie innych części ciała. Istnieje wiele narzędzi do oceny stóp, jednakże wyniki uzyskiwane różnymi metodami nie zawsze są porównywalne. Foot Posture Index (FPI–6) został opracowany jako szybkie, łatwe w użyciu i rzetelne narzędzie służące do oceny stóp w różnych zastosowaniach klinicznych.Cel pracy: Oznaczenie współczynnika powtarzalności pomiarowej dla kwestionariusza FPI-6 zastosowanego do badania stóp u dzieci i młodzieży.Materiał i Metoda: W badaniach wzięło udział 60 osób w trzech grupach wiekowych 9, 12 i 14 lat. W celu określenia powtarzalności pomiarowej FPI-6 wszystkie pomiary przeprowadzono dwukrotnie w 2 tygodniowym odstępie czasowym. Oceniano następujące parametry: wysokość ciała, masa ciała, BMI (Body Mass Index), oraz wykonano ocenę stóp za pomocą FPI-6. Wyniki: Wartość współczynnika powtarzalności R pomiędzy pierwszym i drugim badaniem, dla wszystkich parametrów wynosił 0.89-0.96, co oznacza bardzo dobrą powtarzalność FPI -6 w ocenie stopy. Wysokie wartości współczynnika powtarzalności występują niezależnie od wieku dziecka, wysokości i masy ciała. Zarówno ocena koślawości i szpotawości kości piętowej jak i ocena przywiedzenia /odwiedzenia przodostopia względem kości piętowej w grupach dzieci dziewięcioletnich i dwunastoletnich uzyskały wartości mówiące o lekkiej pronacji stopy, a w grupie dzieci czternastoletnich parametry te ulegały statystycznie istotnej zmianie uzyskując wartości charakterystyczne dla neutralnego ustawienia stopy.Wnioski: FPI-6 jest prostym i rzetelnym narzędziem oceny stopy u dzieci i młodzieży, charakteryzującym się wysokim współczynnikiem zgodności pomiarów powtarzanych przez tego samego badającego.
Źródło:
Medical Rehabilitation; 2010, 14(4); 18-28
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transport of Microbial Components in Coarse and Fine Particle Fractions in Office Buildings
Transport cząstek pochodzenia mikrobiologicznego w drobnej i grubej frakcji aerozolu w budynkach biurowych
Autorzy:
Ławniczek-Wałczyk, Anna
Górny, Rafał L.
Powiązania:
https://bibliotekanauki.pl/articles/1812026.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
office
endotoxins
β-D-glucans
PM1
PM2.5
PM2.5-10
bioaerosol
biuro
endotoksyny
β-D-glukany
bioaerozol
Opis:
In old and modern interiors, particular attention is focused on the air quality as one of major determinants of the well-being of occupants. Exposure to microbiological contaminants in such close indoor space may be associated with the occurrence of various adverse health outcomes in the exposed individuals. Because the size of inhaled particles determines their place of deposition in the human airways and the associated adverse health outcomes, a detailed characteristic of airborne microbial components carried on fine dust particles in office buildings is needed. The aim of this study was to determine the concentrations of endotoxins, (1-3)-β-D-glucans and culturable microorganisms in coarse, fine and aerosol fractions collected in two office buildings in Warsaw. The concentrations of particulate aerosol were measured using Sioutas impactors in PM1, PM2.5, and PM2.5-10. Kinetic-QCL LAL and Glucatell assays were used to detect endotoxin and (1-3)-β-D-glucan concentrations, respectively. The bioaerosol samples were taken using six-stage Andersen impactor as coarse (> 7-2.1µm) and fine (< 2.1µm) fractions, as well. The mean concentrations of particulate aerosol, endotoxins and (1-3)-β-D-glucans in all studied offices were: in PM1 – 6 μg/m3, 4 EU/m3 and 5 ng/m3; in PM2.5 – 11 μg/m3, 6 EU/m3 and 10 ng/m3; and PM10-2.5 – 3.5 μg/m3, 2 EU/m3 and 2.5 ng/m3, respectively. The concentrations of endotoxins and (1-3)-β-glucans in PM2.5 were significantly higher than in PM10-2.5 (p < 0.01 and p < 0.001, respectively) and accounted for 71% and 84% of their total load in PM10. The airborne bacteria occurred mostly in fine fraction (average 3.9 · 102 CFU/m3, p < 0.01), while fungi in coarse fraction of aerosol (5.6 · 101 CFU/m3). The concentrations of endotoxins showed a positive correlation with PM1 (r = 0.61, p < 0.05) and PM2.5 levels (r = 0.76, p < 0.05) as well as with Gram-negative rods in fine fraction (r = 0.75, p < 0.05). The concentrations of (1-3)-β-D-glucans showed positive correlation with PM2.5 (r = 0.54, p < 0.05) and fungi in fine fraction (r = 0.59, p < 0.05). This study demonstrated that endotoxins and (1-3)-β-D-glucans are associated mostly with fine fraction of aerosol particles. Such particles can penetrate the lower parts of the human respiratory system posing a health risk for exposed people. The main source of endotoxins in the offices were Gram-negative rods. The sources of (1-3)-β-D-glucans were probably both fungal conidia and their fragments of aerodynamic diameters <2.1 μm. The noted concentrations of endotoxins and microorganism were within the range normally observed in this type of facilities. Nevertheless, constant monitoring of the hygienic condition is suggested, including regular cleaning and replacement of air filters in the air-conditioning system.
Zarówno w starych, jak i nowoczesnych wnętrzach budynków biurowych szczególną uwagę zwraca się na jakość powietrza, która jest wyznacznikiem dobrostanu mieszkańców. Narażenie na zanieczyszczenia mikrobiologiczne w takich zamkniętych pomieszczeniach może być związane z pojawianiem się różnych niekorzystnych efektów zdrowotnych u narażonych osób. Ponieważ wielkość wdychanych cząstek determinujeich miejsce osadzania w drogach oddechowych człowieka i związane z tym problemy zdrowotne, potrzebna jest szczegółowa charakterystyka frakcji cząstek pyłowych transportujących cząstki pochodzenia mikrobiologicznego w budynkach biurowych. Celem niniejszego badania było poznanie zakresów stężeń endotoksyn, (1-3)-β-D-glukanów i mikroorganizmów w drobnej i grubej frakcji aerozolu ziarnistego w dwóch budynkach biurowych w Warszawie. Stężenia aerozolu ziarnistego zmierzono przy użyciu impaktorów Sioutas we frakcjach PM1, PM2.5 i PM2.5-10. Testy Kinetic-QCL LAL i Glucatell zastosowano odpowiednio do detekcji endotoksyn i β-D-glukanów. Próbki biaerozolu pobrano przy użyciu sześcio-stopniowego impaktora Andersena we frakcji gruboziarnistej (> 7-2,1 μm) i drobnej (< 2,1 μm). Średnie stężenia aerozolu ziarnistego, endotoksyn i β-D-glukanów w wszystkich badanych biurach wynosiły odpowiednio: w PM1 – 6 μg/m3, 4 JE/m3 i 5 ng/m3; w PM2.5 – 11 μg/m3, 6 JE/m3 i 10 ng/m3 i w PM10-2.5 – 3.5 μg/m33, 2 JE/m3 i 2.5 ng/m3. Stężenia endotoksyn i β-D-glukanów w PM2.5 były znacznie wyższe niż w PM10-2.5 (odpowiednio p < 0.01 i p < 0.001) i stanowiły 71% i 84% frakcji PM10. W badanych pomieszczeniach, bakterie występowały głównie w drobnej frakcji aerozolu (3.9·102 JTK/m3, p < 0.01), podczas gdy grzyby izolowano najczęściej z frakcji gruboziarnistej aerozolu (5.6·101 JTK/m3). Stwierdzono pozytywną korelację pomiędzy stężeniami endotoksyn a stężeniami pyłu PM1 (r = 0.61, p < 0.05) i PM2.5 (r = 0.76, p < 0.05), jak również Gram-ujemnymi pałeczkami (r = 0.75, p < 0.05). Stężenia β-D-glucans wykazały korelację z PM2.5 (r = 0.54, p < 0.05) oraz grzybami w drobnej frakcji (r = 0.59, p < 0.05). Niniejsze badania wykazały, że głównym nośnikiem endotoksyn i (1-3)-β-Dglukanów w pomieszczeniach biurowych były drobne frakcje aerozolu ziarnistego. Cząstki te mogą przenikać do dolnych dróg oddechowych powodując niekorzystne skutki zdrowotne u narażonych osób. Stwierdzono, że głównym źródłem endotoksyn były Gram-ujemne pałeczniki. Źródłami (1-3)-β-D-glukanów były głównie fragmenty strzępek grzybni (lub spor) o aerodynamicznych średnicach <2,1 μm. Odnotowane stężenia endotoksyn i mikroorganizmów w biurach mieściły się w zakresie normalnie obserwowanym w tego typu obiektach. Niemniej jednak sugerowane jest stałe monitorowanie stanu higienicznego tych pomieszczeń, w tym regularne czyszczenie i wymienianie filtrów powietrza w instalacji klimatyzacyjnej.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 1099-1115
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distribution of Selected Drug-resistant Enterococcus Species in Meat Plants in Poland
Autorzy:
Ławniczek-Wałczyk, Anna
Cyprowski, Marcin
Górny, Rafał L.
Powiązania:
https://bibliotekanauki.pl/articles/2174931.pdf
Data publikacji:
2022
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
enterococci
antibiotic resistance
biofilm
meat production
Opis:
This study aimed to assess the prevalence of enterococci (including vancomycin-resistant, VRE) strains in meat plants and evaluate their biofilm-forming potential. In two Polish meat plants, 75 samples of raw pork meat, swabs from work surfaces (floors, tables, machine parts and tools) and employees’ hands were collected. The analyses indicated that enterococci were present in more than 72% of the tested samples. In addition, VRE isolates were found in more than 25% of the tested samples (especially in cutting and processing rooms). VRE strains of Enterococcus faecium and E. faecalis were resistant to penicillin, ampicillin, erythromycin, and rifampicin. Moreover, 77% of E. faecium and 43% of E. faecalis isolates showed biofilm-forming ability. The observed high biofilm-forming potential among the analyzed VRE strains indicates that these agents may play an essential role in spreading drug resistance in the food chain through contaminated surfaces, meat, and workers’ hands.
Źródło:
Rocznik Ochrona Środowiska; 2022, 24; 345--359
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Airborne peptidoglycans as a supporting indicator of bacterial contamination in a metal processing plant
Autorzy:
Cyprowski, Marcin
Ławniczek-Wałczyk, Anna
Górny, Rafał L.
Powiązania:
https://bibliotekanauki.pl/articles/2177057.pdf
Data publikacji:
2015-12-09
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
metalworking fluids
peptidoglycans
endotoxins
exposure assessment
size distribution
airborne bacteria
Opis:
Objectives The aim of this study was to assess exposure to airborne endotoxins and peptidoglycans (PGs) as well as possibility of using PGs as a surrogate measure of bacterial exposure in workplaces in a metal processing plant. Material and Methods Personal dosimetry (N = 11) was used to obtain data on concentrations of viable bacteria, total number of bioaerosol particles, endotoxins and peptidoglycans. To investigate the size distributions of aerosol particles responsible for transport of endotoxins and PGs, air samples (N = 5) were additionally collected using the 8-stage cascade impactor. Endotoxins and PGs were assayed with the Limulus amebocyte lysate (LAL) test and a kinetic version of the silkworm larvae plasma (SLP) test, respectively. Results Median concentrations of airborne PGs (14.6 ng/m³), endotoxins (0.2 ng/m³), viable bacteria (1.16×10³ CFU/m³) and the total number of bioaerosol particles (1.81×10⁶ cells/m³) were determined. Qualitative analysis revealed presence of 19 bacterial species belonging to 14 genera. The calculations showed strong, significant correlations (p < 0.05) between endotoxins, viable bacteria (r = 0.75) and the total number of bioaerosol particle concentrations (r = 0.76) as well as between PGs and the total number of bioaerosol particle concentrations (r = 0.72). Size distribution analysis showed that the highest concentrations of bacterial aerosols occurred in the range of 2.1–3.3 μm. In the case of endotoxins, an increase of concentrations in 2 ranges of aerodynamic diameters: 1.1–3.3 μm and 5.8–9 μm was shown. For PGs there was a visible gradual increase of their concentrations in the range 2.1–9 μm. Conclusions Peptidoglycans can be treated as a supporting indicator of bacterial contamination in metal processing plants, particularly when an assessment of an immunotoxic potential of microbiological hazards needs to be performed. However, to be extrapolated to other occupational and non-occupational environments, the obtained results require a further verification.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2016, 29, 3; 427-437
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure of ventilation system cleaning workers to harmful microbiological agents
Narażenie pracowników konserwujących instalacje wentylacyjne na szkodliwe czynniki mikrobiologiczne
Autorzy:
Gołofit-Szymczak, Małgorzata
Ławniczek-Wałczyk, Anna
Górny, Rafał L.
Powiązania:
https://bibliotekanauki.pl/articles/2166331.pdf
Data publikacji:
2014-11-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
bioaerozole
instalacje wentylacyjne
narażenie zawodowe
szkodliwe czynniki biologiczne
bioaerosols
ventilation systems
occupational exposure
harmful biological agents
Opis:
Background: Regular inspection of the cleanliness of the ventilation systems, as well as their periodic cleaning and disinfection, if necessary, are the main factors of the proper maintenance of each system. Performing maintenance operations on the ventilation system, workers are exposed to risk associated with the exposure to harmful biological agents. The aim of this study was to assess the employees' exposure to bioaerosols during maintenance work on ventilation systems. Material and Methods: Bioaerosol measurements were carried out using a button sampler. The microbial particles were collected on gelatin filters. Settled-dust samples from the inner surface of the air ducts and filter-mat samples were selected for the microbiological analysis. In the collected air, dust and filter samples the concentration of bacteria and fungi were determined. Results: Bacteria and fungi concentrations ranged between 3.6×10²-2.2×10⁴ CFU/m³ and 4.7×10²-4.5×10³ CFU/m³ at workplaces where the operations connected with mechanical ventilation cleaning were performed and 2.2×10⁴-1.2×10⁵ CFU/m³ and 9.8×10¹-2.5×10² CFU/m³ at workplaces where filter exchange was performed, respectively. The qualitative analysis of microorganisms isolated from the air in all studied workplaces revealed that the most prevalent bacteria belonged to Bacillus genus. The average concentrations of bacteria and fungi in filter-mat samples were 3.3×10³ CFU/cm² and 1.4×10⁴ CFU/cm², respectively. In settled-dust samples, average concentrations were 591 CFU/100 cm² and 52 CFU/100 cm², for bacteria and fungi respectively. Conclusions: Workers cleaning ventilation systems are exposed to harmful biological agents classified into risk groups, 1 and 2, according to their level of the risk of infection. The research conducted in the workplace can be the basis of risk assessment related to exposure to harmful biological agents during maintenance work in ventilation. Med Pr 2013;64(5):613–623
Wprowadzenie: Istotnym elementem właściwej eksploatacji instalacji wentylacyjnych jest regularna kontrola czystości wentylacji oraz jej okresowe czyszczenie i dezynfekcja. W ostatnich latach obserwuje się dynamiczny rozwój firm zajmujących się konserwacją instalacji wentylacyjnych. Pracownicy prowadzący prace konserwacyjne instalacji wentylacyjnej narażeni są na działanie szkodliwych czynników biologicznych. Celem niniejszej pracy było określenie narażenia na te czynniki podczas prac konserwacyjnych w instalacjach wentylacyjnych. Materiał i metody: Pobieranie próbek powietrza wykonano jako pomiar indywidualny za pomocą pobornika guzikowego. Powierzchnię wychwytu stanowiły sterylne filtry żelatynowe. Analizie poddano również próbki pyłu osiadłego z wewnętrznych powierzchni przewodów wentylacyjnych oraz próbki zużytych mat filtracyjnych. Zarówno w próbkach powietrza, pyłu osiadłego, jak i filtrach określano stężenie bakterii i grzybów, a następnie identyfikowano rodzaj lub gatunek wyizolowanych mikroorganizmów. Wyniki: Stężenia aerozolu bakteryjnego i grzybowego mieściły się w zakresie odpowiednio 3,6×10²-2,2×10⁴ jtk/m³ i 4,7×10²-4,5×10³ jtk/m³ na stanowiskach pracy, na których wykonywano czynności związane z mechanicznym czyszczeniem instalacji wentylacyjnych, oraz 2,2×10⁴-1,2×10⁵ jtk/m³ i 9,8×10¹-2,5×10² na stanowiskach pracy, na których wymieniano filtry. W powietrzu na wszystkich badanych stanowiskach pracy dominowały bakterie z rodzaju Bacillus. Średnie stężenie mikroorganizmów wyizolowanych z próbek mat filtracyjnych wynosiło dla bakterii: 3,3×10³ jtk/cm², a dla grzybów: 1,4×10⁴ jtk/cm², natomiast z próbek pyłu osiadłego - 591 jtk/100 cm² dla bakterii i 52 jtk/100 cm² dla grzybów. Wnioski: Pracownicy konserwujący instalacje wentylacyjne są narażeni na kontakt ze szkodliwymi czynnikami biologicznymi z 1. i 2. grupy zagrożenia. Badania przeprowadzone na stanowiskach pracy mogą być podstawą oceny ryzyka zawodowego związanego z narażeniem na szkodliwe czynniki biologiczne podczas prac konserwacyjnych w instalacjach wentylacyjnych. Med. Pr. 2013;64(5):613–623
Źródło:
Medycyna Pracy; 2013, 64, 5; 613-623
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Is aldehyde dehydrogenase inhibited by sulfur compounds? In vitro and in vivo studies
Autorzy:
Iciek, Małgorzata
Górny, Magdalena
Bilska-Wilkosz, Anna
Kowalczyk-Pachel, Danuta
Powiązania:
https://bibliotekanauki.pl/articles/1038534.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
aldehyde dehydrogenase
reactive sulfur species
sulfane sulfur
Opis:
Aldehyde dehydrogenase (ALDH) catalyzes the critical step of ethanol metabolism, i.e. transformation of toxic acetaldehyde to acetic acid. It is a redox sensitive protein with the key Cys in its active site. Recently, it has been documented that activity of some proteins can be modified by sulfur-containing molecules called reactive sulfur species leading to the formation of hydro- persulfides. The aim of the present study was to examine whether ALDH activity can be modified in this way. Studies were performed in vitro using yeast ALDH and various reactive sulfur species, including Na2S, GSSH, K2Sx, Na2S2O3, and garlic-derived allyl sulfides. The effect of garlic-derived trisulfide on ALDH activity was also studied in vivo in the rat liver. The obtained results clearly demonstrated that ALDH could be regulated by sulfur species which inhibited its enzymatic activity. The results also suggested that not H2S but polysulfides or hydropersulfides were the oxidizing species responsible for this modification. This process was easily reversible by reducing agents. After the treatment with polysulfides or hydropersulfides the level of protein-bound sulfur increased, while the activity of the enzyme dramatically decreased. Moreover, the study demonstrated that ALDH activity was inhibited in vivo in the rat liver after garlic-derived trisulfide administration. This is the first study reporting the regulation of ALDH activity by sulfane sulfur species and the results suggest that it leads to the inhibition of the enzyme.
Źródło:
Acta Biochimica Polonica; 2018, 65, 1; 125-132
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbial Air Quality in Municipal Buses Before and After Disinfection of their Air-Conditioning Systems
Autorzy:
Gołofit-Szymczak, Małgorzata
Stobnicka-Kupiec, Agata
Górny, Rafał L.
Cyprowski, Marcin
Ławniczek-Wałczyk, Anna
Powiązania:
https://bibliotekanauki.pl/articles/123259.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
buses
air-conditioning system
bioaerosol
bacteria
fungi
Opis:
To ensure the proper quality of the air and simultaneously improve the comfort of professional drivers or travellers, the cars are fit with air-conditioning (AC) systems. The AC installations, however, quite often create suitable conditions for the development of microbiological agents and become an active emission source of harmful bioaerosols. This study was carried out in 6 municipal buses in large city located in central Poland. In studied vehicles, ozonisation or manual application of chemical disinfectant in a spray form were used for disinfection of AC bus systems. The concentrations of bacteria and fungi in the air collected in buses before the service of their AC installations were 4.3×102 CFU/m3 and 2.4×102 CFU/m3, respectively. After AC service using both tested disinfection methods, the decrease in microbial concentrations in the air of municipal buses was observed. The highest effectiveness of AC cleaning was noted when the chemical disinfectant in a spray form was used. This study revealed that to eliminate microbiological contamination and, by that, decrease the exposure of both drivers and passengers to harmful microbial contaminants, the chemical disinfection of bus AC system should be performed at regular basis.
Źródło:
Journal of Ecological Engineering; 2019, 20, 10; 189-194
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to culturable and total microbiota in cultural heritage conservation laboratories
Autorzy:
Górny, Rafał L.
Harkawy, Aleksander S.
Ławniczek-Wałczyk, Anna
Karbowska-Berent, Joanna
Wlazło, Agnieszka
Niesler, Anna
Gołofit-Szymczak, Małgorzata
Cyprowski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2177074.pdf
Data publikacji:
2015-10-23
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
settled dust
bioaerosol
conservation laboratory
cultural heritage
occupational exposure
microbial hazards
Opis:
Objectives To date, the scientific source materials usually focus on microbial contamination of the museum or library collections themselves, while the exposure of persons who professionally deal with this type of objects in cultural heritage conservation laboratories is ignored. Material and Methods The study was carried out in 9 naturally ventilated conservation laboratories with no history of water damage. Viable (understood as culturable) bioaerosol stationary samples were collected in both outdoor and indoor environments using 6-stage Andersen impactor. Simultaneously, stationary and personal indoor bioaerosol measurements were carried out using both Gesamtstaubprobenahme an der Person (GSP) and Button filter samplers. These measurements were complemented by evaluation of microbial content in the dust settled on conserved works of art. All impactor, filter, and settled dust samples were quantitatively examined to obtain viable and total concentrations of bacteria and fungi. All isolated microbial strains were taxonomically identified. Results At workplaces, the concentrations of viable microorganisms in air were below 2000 cfu/m³ and accounted for not more than 5.5% of total microbiota. The study showed that quantitative assessment of viable bioaerosol can be made with an Andersen impactor as well as by using Button and GSP filter samplers, irrespective of whether they are applied for personal or stationary measurements. Compared to the impactor, however, the use of filter samplers for microbial contamination monitoring substantially limits the scope of qualitative information which can be obtained. Size distribution analysis revealed that the largest “load” of microorganisms can penetrate into the respiratory tract between the trachea and terminal bronchi, and thereby may be responsible for allergic inflammations in exposed workers. Conclusions The precise assessment of microbial hazards in conservation laboratories should comprise control of both viable and total particle counts. The hermetization of such workplaces and control of relative humidity should be implemented and maintained to assure proper hygienic conditions.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2016, 29, 2; 255-275
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies