Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Dulski, R." wg kryterium: Autor


Wyświetlanie 1-10 z 10
Tytuł:
Thermovision investigations of the shot phenomena
Termowizyjne badania zjawiska wystrzału z broni palnej
Autorzy:
Dulski, R.
Kastek, M.
Trzaskawka, P.
Powiązania:
https://bibliotekanauki.pl/articles/157606.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
detekcja wystrzału
błysk wystrzału
sygnatura w podczerwieni
shot detection
muzzle flash
IR signature
Opis:
The paper presents some practical aspects of shoot IR signature measurements. It includes the description of equipment, measurement methodology and analysis. The measurements were taken on a shooting range. The high precision laboratory measurements were also performed. Fast infrared measurement class cameras were used during measurements to cover all measurement assumptions. The registration was made in SWIR and LWIR spectral bands simultaneously. An ultra fast visual camera was also used for visible spectral registration. Exemplary shot images and analysis for typical situation were presented. The problem of the measurement of IR shot signature is very important due to recent development of anti-sniper systems.
W artykule zaprezentowano praktyczne aspekty pomiarów zjawiska wystrzału w zakresie podczerwieni. Omówiono zastosowane do badań urządzenia, metodykę pomiarów oraz analizy zarejestrowanych danych pomiarowych. Omawiane pomiary wykonano zarówno w warunkach poligonowych, jak i laboratoryjnych. Badania laboratoryjne dostarczyły niezbędnych danych do kalibracji i weryfikacji zarejestrowanych danych. Do badań użyto pomiarowych kamer termowizyjnych pracujących w zakresie krótko i długofalowym. Wybór sprzętu został podyktowany szybkozmiennym charakterem zjawiska wystrzału, wysoką rozdzielczością temperaturową i przestrzenną urządzeń oraz dedykowanym oprogramowaniem do analizy rejestracji o bardzo dużych możliwościach. Na przykładowych termogramach zaprezentowano zarejestrowane dane pomiarowe oraz omówiono warunki ich rejestracji i zastosowane techniki analizy. Badania sygnatur termalnych wystrzału oraz strzelca są obecnie jednym z głównych celów badań światowych laboratoriów pracujących nad nowymi generacjami systemów wykrywania strzelca. Systemy takie mają coraz szersze zastosowanie, zarówno do ochrony osób i miejsc publicznych przed atakami terrorystycznymi, jak i w trakcie regularnych działań bojowych czy w warunkach konfliktów asymetrycznych. Przeprowadzone badania i analizy pokazały, że zastosowanie obrazujących urządzeń termodetekcyjnych do wykrywania zjawiska wystrzału jest bardzo obiecującą technologią.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 962-965
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electro-optical passive sniper detection conception and system overview
Pasywne wykrywanie strzelca wyborowego : koncepcja i optoelektroniczne systemy wykrywania
Autorzy:
Kastek, M.
Dulski, R.
Trzaskawka, P.
Powiązania:
https://bibliotekanauki.pl/articles/210046.pdf
Data publikacji:
2010
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
detekcja
termowizja
analiza obrazu
systemy optoelektroniczne
sniper detection
muzzle flash detection
infrared detection
Opis:
The paper presents modern sensor systems for sniper detection. Among such systems there are active and passive optoelectronic devices. Its primary advantage is the possibility of early recognition of the threat, before the sniper is able to take the shot. Presented passive systems employ thermal cameras and advanced image processing algorithms to distinguish the sniper and muzzle blast signatures. Active systems, in turn, rely on the detection of laser radiation, retro reflected from pointed optics (optical sights and observation scopes). The paper presents basic technical and tactical characteristics of sniper detection devices, both standalone and included in multi-sensor detection systems.
W artykule przedstawiono współczesne systemy detekcyjne przeznaczone do wykrywania snajpera. Wśród systemów tego typu, wprowadzanych na uzbrojenie wielu armii istotną rolę pełnią pasywne i aktywne systemy optoelektroniczne. Ich zaletą jest możliwość wczesnej detekcji zagrożenia, zwłaszcza przed oddaniem strzału przez snajpera. Przedstawione systemy pasywne wykorzystują kamery termowizyjne i zaawansowane metody analizy obrazu w celu wykrycia sygnatur snajpera i strzału z broni palnej. Systemy aktywne wykorzystują z kolei promieniowanie laserowe w celu wykrycia optycznych przyrządów celowniczych i obserwacyjnych.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2010, 59, 3; 277-293
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optoelectronics systems for sniper detection
Optoelektroniczne systemy wykrywania strzelca wyborowego
Autorzy:
Kastek, M.
Dulski, R.
Trzaskawka, P.
Zygmunt, M.
Wojtanowski, J.
Kaszczuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/236092.pdf
Data publikacji:
2009
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
systemy detekcyjne
systemy optoelektryczne
systems detection
optoelectronics systems
Opis:
The paper presents modern sensor systems for sniper detection. Among such systems there are active and passive opto-electronic devices. Its primary advantage is the possibility to early recognize the threat, before the sniper is able to take the shot. Presented passive systems employ thermal cameras and advanced image processing algorithms to distinguish the sniper and muzzle blast signatures. Active systems, in turn, rely on the detection of laser radiation, retro reflected from pointed optics (optical sights and observation scopes). The paper presents basic technical and tactical characteristics of sniper detection devices, both standalone and included in multi-sensor detection systems.
W artykule przedstawiono współczesne systemy detekcyjne przeznaczone do wykrywania snajpera. Wśród systemów tego typu, wprowadzanych na uzbrojenie wielu armii istotną rolę pełnia pasywne i aktywne systemy optoelektroniczne. Ich zaletą jest możliwość wczesnej detekcji zagrożenia, zwłaszcza przed oddaniem strzału przez snajpera. Przedstawione systemy pasywne wykorzystują kamery termowizyjne i zaawansowane metody analizy obrazu w celu wykrycia sygnatur snajpera i strzału z broni palnej. Systemy aktywne wykorzystują z kolei promieniowanie laserowe w celu wykrycia optycznych przyrządów celowniczych i obserwacyjnych. W artykule przedstawiono charakterystyki techniczne i taktyczne szeregu urządzeń optoelektronicznych przeznaczonych do wykrywania snajpera, pracujących jako samodzielne urządzenia bądź jako elementy składowe \\ieloczujnikowych systemów detekcyjnych.
Źródło:
Problemy Techniki Uzbrojenia; 2009, R. 38, z. 109; 23-30
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multisensor system for the protection abovewater of seaport
Autorzy:
Kastek, M.
Życzkowski, M.
Szustakowski, M.
Trzaskawka, P.
Ciurapiński, W.
Dulski, R.
Powiązania:
https://bibliotekanauki.pl/articles/331780.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
There are many separated infrastructural objects within a harbor area that may be considered „critical”, such as gas and oil terminals or anchored naval vessels. Those objects require special protection, including security systems capable of monitoring both surface and underwater areas, because an intrusion into the protected area may be attempted using small surface vehicles (boats, kayaks, rafts, floating devices with weapons and explosives) as well as underwater ones (manned or unmanned submarines, scuba divers). The paper will present the concept of multisensor security system for a harbor protection, capable of complex monitoring of selected critical objects within the protected area. The proposed system consists of a command centre and several different sensors deployed in key areas, providing effective protection from land and sea, with special attention focused on the monitoring of underwater zone. The protection of surface area is based on medium-range radar and LLTV and infrared cameras.
Źródło:
Hydroacoustics; 2013, 16; 101-112
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Visible and infrared signatures of the shop
Sygnatury wystrzału w zakresie widzialnym i w podczerwieni
Autorzy:
Dulski, R.
Kastek, M.
Trzaskawka, P.
Surma, Z.
Koperski, W.
Leciejewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/236090.pdf
Data publikacji:
2009
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
broń strzelecka
sygnatury wystrzału
shooting weapon
signatures of the shot
Opis:
The paper presents the signatures of the gun shot. The phenomena associated with the shot were described, that can be used for the detection of the shooter in visible and infrared spectral range. The methods of shot signature measurements are described, along with the recording equipment and algorithms for data analysis. Sample signatures of muzzle flash from military weapons are presented, including most popular calibers of 5,56 mm and 7,62 mm. The signatures were recorded under field and laboratory conditions at the Military University of Technology. The research work was aimed at the verification of the usability of electro-optical sensors for sniper detection and at the methods of signature acquisition for this particular detection task.
W artykule omówiono problematykę sygnatur wystrzału z broni strzeleckiej. Opisano zjawiska fizyczne będące wynikiem wystrzału, wykorzystywane do wykrywania strzelca w zakresach widzialnym i w podczerwieni. Opisano metodykę rejestracji sygnatur wystrzału, użyte do rejestracji narzędzia pomiarowe oraz sposób analizy zarejestrowanych danych. Zaprezentowano przykładowe sygnatury wystrzału z broni kalibru 5,56 mm oraz 7,62 mm, zarejestrowane w czasie badań laboratoryjnych i poligonowych w Wojskowej Akademii Technicznej. Badania miały na celu potwierdzenie użyteczności czujników elektro-optycznych do wykrywania strzelca wyborowego oraz opracowanie metodologii pozyskiwania sygnatur dla takiego zadania.
Źródło:
Problemy Techniki Uzbrojenia; 2009, R. 38, z. 109; 31-38
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Procedure of the Positronium Lifetime Spectra for the J-PET Detector
Autorzy:
Dulski, K.
Zgardzińska, B.
Białas, P.
Curceanu, C.
Czerwiński, E.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, Shivani
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033298.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.05.Kf
13.30.Ce
14.60.-z
78.47.-p
Opis:
Positron annihilation lifetime spectroscopy has shown to be a powerful tool to study the nanostructures of porous materials. Positron emission tomograph is a device allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the Jagiellonian PET will allow positron annihilation lifetime spectroscopy in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the Jagiellonian PET software. We compare its performance with the standard program LT 9.0 by using positron annihilation lifetime spectroscopy data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1637-1640
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time Calibration of the J-PET Detector
Autorzy:
Skurzok, M.
Silarski, M.
Alfs, D.
Białas, P.
Shivani, S.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033283.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.fb
36.10.Dr
11.30.Er
24.80.+y
Opis:
The Jagiellonian positron emission tomograph project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time-and high angular resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a ²²Na source and a small detector providing common reference time for synchronization of all the modules.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1641-1644
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of J-PET detector spatial resolution
Autorzy:
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Alfs, D.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, M.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Shivani, -
Silarski, M.
Skurzok, M.
Sharma, N.
Sharma, S.
Shopa, R.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057928.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1645-1648
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Human tissue investigations using PALS technique - free radicals influence
Autorzy:
Jasińska, B.
Zgardzińska, B.
Chołubek, G.
Pietrow, M.
Gorgol, M.
Wiktor, K.
Wysogląd, K.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Hiesmayr, B.
Jodłowska-Jędrych, B.
Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiktor, H.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057941.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
positron annihilation
positronium
free radicals
tissues
uterine leiomyomas
Opis:
The positron annihilation lifetime spectroscopy was applied to the samples of the human uterine leiomyomas and the normal myometrium tissues taken from the selected place of the uterus during a surgery. The method indicated differences in values of the measured positron annihilation lifetime spectroscopy parameters (lifetimes and intensities) between healthy and diseased tissue samples. The additional measurements were performed either in darkness or in presence of visible light which influenced the free radicals present in both kind of tissues and, as a result, made changes in free annihilation and o-Ps decay lifetime and intensity values.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1556-1558
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies