Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Cichoń, A." wg kryterium: Autor


Tytuł:
The Application of the Selected Time-Frequency Descriptors Detection of the Acoustic Emission Signals Generated by Multisource Partial Discharges
Autorzy:
Cichon, A.
Powiązania:
https://bibliotekanauki.pl/articles/1795791.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.80.-s
43.28.Js
Opis:
The paper presents the comparative analysis results of the acoustic emission signals generated by various forms of partial discharges occurring in multisource systems. Modern methods of the signal digital processing: a short-time Fourier transform and continuous and discrete wavelet transforms were applied for the assessment of the results in the time-frequency domain. The acoustic emission signals generated by partial discharges were registered with a WD AH17 contact transducer by the Physical Acoustics Corporation placed on the external part of the tub.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 290-293
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of surface type partial discharges using electrical, acoustic emission and UHF methods
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/114691.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
partial discharges
PD measurements
UHF method
AE method
IEC60270
transformer fault diagnosis
Opis:
This paper presents research results related to measurements of partial discharges (PD), which may occur in oil insulation systems of electric power transformers. Three measuring methods were considered: electrical (apparent charge - IEC60270), acoustic emission (AE) and ultra-high frequency (UHF) method. Research works have been proceeded under laboratory condition. PD were generated using special apparatus and spark gap configuration for surface PD modeling. Measurements were performed simultaneously for each of the regarded methods and were repeated for selected supply voltage levels. The electrical and UHF methods measurements were made using MPD measuring system from Omicron. The AE method measurements were made using a piezoelectric transducer, which was installed on the outer transformer tank wall. Comparative analysis of signals gathered during research works was made. Possibilities of application of the three considered PD detection methods for electric power systems with oil insulation were proposed in the paper.
Źródło:
Measurement Automation Monitoring; 2015, 61, 1; 12-15
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time and frequency domain analysis of partial discharges using electrical method
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/973070.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
partial discharges
electrical method
IEC 60270
frequency domain
time domain
Opis:
Partial discharge (PD) measurement results with particular consideration of time domain and frequency domain analysis of pulses generated by PD model sources are presented in the paper. Three different PD generation model sources are selected for the research: surface type, point to point and multi-point to plate. All measurements are proceeded under laboratory conditions using electrical method of a PD detection, according to the IEC60270 standard. Various amplitude and power density spectrum descriptors are proposed, as well as PD source type identification abilities on grounds of the selected descriptors are considerated. Electrical power transformers on-line PD detection and evaluation systems improvement and development are the main purpose of the presented research. Laboratory experiment results gives a solid base for further research focused on verification of the proposed methodology on a real life apparatus.
Źródło:
Measurement Automation Monitoring; 2016, 62, 2; 72-77
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a Phase Resolved Partial Discharge Pattern Analysis for Acoustic Emission Method in High Voltage Insulation Systems Diagnostics
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177912.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
insulation system
Opis:
An alternative method for analysis of acoustic emission (AE) signals generated by partial discharges (PD), based on a correlation between voltage phase run and AE pulses, so called phase resolved PD pattern (PRPD), is presented in the paper. PRPD pattern is a well-known analysis tool commonly used in such PD diagnostic methods as conventional electrical and UHF ones. Moreover, it yields various signal analysis abilities and allows a direct correlation indication between measurement results achieved using different methods. An original PRPD measurement methodology applied for AE method as well as some exemplary measurement results and further data analysis capabilities are presented in the paper. Also a comparative analysis of PRPD patterns achieved using various measurement methods and different PD source configurations have been investigated. All presented experiments were done under laboratory conditions using PD model sources immersed in the insulation oil. The main purpose of the presented research is to indicate an all-embracing analytical tool that yields an ability to direct comparison (qualitative as well as quantitative) of the AE measurement results with other commonly applied PD measurement methods. The presented results give a solid fundamental for further research work concerning a direct correlation method for AE and other described in the paper diagnostic techniques, mainly in order to continue PD phenomena analysis and assessment in real life high voltage apparatus insulation systems under normal onsite operation conditions.
Źródło:
Archives of Acoustics; 2018, 43, 2; 235-243
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Descriptors of Acoustic Emission Signals Generated by Partial Discharges under Laboratory Conditions and in On-Site Electrical Power Transformer
Autorzy:
Kunicki, M.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176881.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
An acoustic emission method (AE) is widespread and often applied for partial discharge (PD) diagnostics, mainly due to its ease of application as well as noninvasiveness and relatively high sensitivity. This paper presents comparative analysis of AE signals measurement results archived under laboratory conditions as well as on-site actual AE signals generated by inside PDs in electrical power transformer during its normal service. Three different PD model sources are applied for laboratory research: point to point, multipoint to plate and surface type. A typical measuring set up commonly used for on-site transformer PD diagnostics is provided for the laboratory tasks: piezoelectric joint transducer, preamplifier, amplifier and measuring PC interface. During the on-site research there are three measuring tracks applied simultaneously. Time domain, time-frequency domain and statistical tools are used for registered AE signals analysis. A number of descriptors are proposed as a result of the analysis. In the paper, attempt of AE signals descriptors, archived under laboratory condition application possibilities for on-site PD diagnostics of power transformers during normal service is made.
Źródło:
Archives of Acoustics; 2016, 41, 2; 265-276
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical Possibilities of Reducing the Sound Pressure Level Emitted into the Environment by a Power Transformer
Autorzy:
Borucki, S.
Boczar, T.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177473.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
corrected sound pressure level
noise
modernization
Opis:
The subject presented in this paper refers to measurements and assessment of the corrected sound pressure level values (noise) occurring around a medium-power transformer. The paper presents the values of noise accompanying the operation of the power object before and after its modernization, which consisted in repeated core pressing and replacement of the cooling system. The main aim of the research work was the assessment of the influence of the repair work on the noise level emitted into the environment.
Źródło:
Archives of Acoustics; 2011, 36, 1; 49-56
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of Acoustic Emission Signals Generated in On Load Tap Changer
Autorzy:
Cichoń, A.
Borucki, S.
Wotzka, D.
Powiązania:
https://bibliotekanauki.pl/articles/1199209.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The paper deals with mathematical modeling of acoustic emission signals which are generated in on load tap changers. In power engineering area acoustic emission method is commonly used for diagnosis purposes. Authors in their research works apply it for detection of defects occurring in on load tap changers, which are important elements of power transformers. The acoustic emission method is based on measurements performed by use of wideband piezoelectric transducers that are mounted on transformer tank surface. The registered signal is then analyzed in the time, frequency, and time-frequency domains or is evaluated with computer expert systems for diagnosis purposes. Depending on indicators device technical condition can be determined. The contribution given by the authors in this paper is proposal of a mathematical model, which describes envelope of the measured acoustic emission signal.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1396-1399
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of the Core Mechanical Construction Based on Vibroacoustic Measurements and Distribution of Temperature Field in Transformer Magnetic Circuit
Autorzy:
Borucki, S.
Cichon, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/1401874.pdf
Data publikacji:
2015-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
Subject matter of this article concerns the results of research works on the development and use of the vibroacoustic method to evaluate technical state of transformer cores. The article presents obtained measurement results of transformer mechanical vibration for two cases of its operation: with twisted and loosened core. In order to demonstrate negative effects of operating a transformer with a loosened core, this publication presents thermographic images showing temperature distribution on its magnetic core. The article characterises the examined transformer, employed measurement system and methodology of the completed experiment. The vibroacoustic and thermographic measurements were carried out during idle work of the transformer. Core vibration was registered for three measurement axes: 0X, 0Y and 0Z. Completed tests have proven that loosened screws pressing the core cause evident increase in the value of magnetic core vibration acceleration. At the same time, the temperature rises by more than 25%.
Źródło:
Acta Physica Polonica A; 2015, 128, 3; 306-309
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selecting Mother Wavelet for Wavelet Analysis of On-Load Tap Changer Acoustic Emission
Autorzy:
Cichoń, A.
Berger, P.
Wotzka, D.
Powiązania:
https://bibliotekanauki.pl/articles/1401875.pdf
Data publikacji:
2015-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.58.Wc
Opis:
Wavelet transformation is one of the most popular tools for acoustic signal analysis. It provides good resolution both in time and frequency domains as well as wide choice of mother wavelets - this makes wavelet transformation a choice when flexible approach is required. However, selecting parameters of analysis can be difficult, especially regarding mother wavelet as different mother wavelets have various properties regarding number of vanishing moments and symmetry. This paper presents studies to determine the possibility of on-load tap changer wear detection by applying wavelet transformation. In research, different mother wavelets were selected and their usefulness was examined. Signals to be analyzed were obtained during on-load tap changer operation in different mechanical conditions - simulating devices wear in service. All measurements were performed on model very similar to real industrial on-load tap changer. Tests were conducted in controlled laboratory environment, reducing most of the possible disruptions.
Źródło:
Acta Physica Polonica A; 2015, 128, 3; 310-314
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selecting Sensor for On Load Tap Changer Contacts Degree of Wear Diagnostics
Autorzy:
Cichoń, A.
Borucki, S.
Berger, P.
Powiązania:
https://bibliotekanauki.pl/articles/1399337.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
Results of scientific research works considering selection of measuring transducer applied for registration of acoustic emission signals generated by on load tap changers are presented in the paper. During the coupling process acoustic emission signals are generated by: the mechanical setup of tap changer, contacts operation, and other phenomena. For most on load tap changers types, the working medium is insulation oil in which the acoustic wave being formed propagates to the steal tank. There exists a possibility to register acoustic emission signals with a piezoelectric transducer attached to the outer tank surface or with a hydrophone immersed in the oil. Acoustic emission signal obtained in such manner contains information which describes operation of the power tap changer and the selector. A comparative analysis of acoustic emission signals generated by on load tap changers working under laboratory conditions, with applied measuring transducers with different transmittances, is presented in the paper. The comparative analysis was performed in order to determine their suitability for on load tap changers technical condition diagnosis. Based on the results achieved, one transducer which allows the registration of acoustic events generated during on load tap changers operation was selected.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 395-398
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristic of Acoustic Signals Generated by Operation of On Load Tap Changers
Autorzy:
Cichon, A.
Fracz, P.
Zmarzly, D.
Powiązania:
https://bibliotekanauki.pl/articles/1493036.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.80.-s
43.28.Js
Opis:
Possibilities of application of the acoustic method for the on load tab changers diagnosis has been presented in the paper. The analysis of measurement results gathered during research works performed under laboratory conditions has been presented in detail. The registered acoustic signals have been analyzed in time and time-frequency domains. The time domain analysis has been performed by presentation of time runs and their envelopes determined by use of the Hilbert transform. Evaluation of the time-frequency components has been performed by use of the short-time Fourier transform, the discrete and the continuous wavelet transforms.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 585-588
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Interference Signals Generated by Vibroacoustic Vibrations of Transformer Cores
Autorzy:
Boczar, T.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/1199078.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
79.60.Bm
42.79.Pw
52.80.Hc
Opis:
The article deals with the subject matter referring to the interference that may accompany measurements of vibroacoustic signals, generated by electric power transformers, taken by using the acoustic emission method under industrial conditions. Paper concerns measurement and analysis of internal, acoustic type disturbances, including the magnetostrictive vibrations of plate sets within the transformer core, caused by changes in the magnetic flux. Paper presents measurement results of acoustic interfering signals and results of analyses made in the frequency and time-frequency domains. Power spectral density, MUSIC pseudospectra, two- and three-dimensional short time Fourier transform spectrograms, continuous wavelet transform scalograms, discrete wavelet transform, and quantities of energy transferred are included in the paper.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1355-1359
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the Acoustic Emission Method for Diagnosis of On-Load Tap Changer
Autorzy:
Majchrzak, H.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176624.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
This paper provides an example of the application of the acoustic emission (AE) method for the diagnosis of technical conditions of a three-phase on-load tap-changer (OLTC) GIII type. The measurements were performed for an amount of 10 items of OLTCs, installed in power transformers with a capacity of 250 MVA. The study was conducted in two different OLTC operating conditions during the tapping process: under load and free running conditions. The analysis of the measurement results was made in both time domain and time-frequency domain. The description of the AE signals generated by the OLTC in the time domain was performed using the analysis of waveforms and determined characteristic times. Within the time-frequency domain the measured signals were described by short-time Fourier transform spectrograms.
Źródło:
Archives of Acoustics; 2017, 42, 1; 29-35
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of the Non-Concurrent Operation of the On-Load Tap Changer Contacts by the Acoustic Emission Method
Autorzy:
Cichoń, A.
Borucki, S.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177044.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
on-load tap changers
acoustic emission method
Opis:
On-load tap changers (OLTC) are some of the main transformer elements that make voltage adjustment in a power network possible. Their failures often cause shutdowns of distribution transformers. The paper presents research work aimed at the assessment of the technical condition of OLTCs by the acoustic emission method (EA). This method makes the OLTC diagnosis possible without the need of disconnecting the transformer from the system. The measurements were taken in laboratory conditions. The influence on the operation non-concurrence of the power tap changer contacts on the AE registered signals has been investigated. The signals registered were subjected to analyses in the time and time-frequency domains. The result analysis in the time domain was carried out using the Hilbert transform and calculating characteristic times for the particular runs. A short-time Fourier transform was used for the assessment of results in the time-frequency do- main.
Źródło:
Archives of Acoustics; 2011, 36, 4; 823-830
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling and Experimental Verification of Ultrasound Transmission in Electro Insulation Oil
Autorzy:
Wotzka, D.
Cichoń, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177158.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound transmission
numerical simulations
electro-insulation oil
Opis:
A verification study of ultrasound transmission numerical simulation results with experiment results is presented in this paper. The work considers a model of a transformer tank which is filled with electro insulating oil. In the experiment, performed under laboratory conditions, an ultrasound wave is generated by a piezoelectric transducer that is fixed in the centre of the tank and measured by another transducer mounted inside the tank at three distances: 10, 20 and 30 cm from the sound source. The transducer is able to measure and generate acoustic waves in the ultrasound frequency band up to 1 MHz. The simulation considers numerical calculation of acoustic pressure distribution inside the tank in which acoustic source emits waves with frequency equal to 100 kHz. Verification analysis has confirmed consistency of the numerically calculated values with the measurement results.
Źródło:
Archives of Acoustics; 2012, 37, 1; 19-22
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies