Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Chabowski, K." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Simple Wide Frequency Range Impedance Meter Based on AD5933 Integrated Circuit
Autorzy:
Chabowski, K.
Piasecki, T.
Dzierka, A.
Nitsch, K.
Powiązania:
https://bibliotekanauki.pl/articles/221804.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impedance
converter
AD5933
system-on-a-chip
measurement
Opis:
As it contains elements of complete digital impedance meter, the AD5933 integrated circuit is an interesting solution for impedance measurements. However, its use for measurements in a wide range of impedances and frequencies requires an additional digital and analogue circuitry. This paper presents the design and performance of a simple impedance meter based on the AD5933 IC. Apart from the AD5933 IC it consists of a clock generator with a programmable prescaler, a novel DC offset canceller for the excitation signal based on peak detectors and a current to voltage converter with switchable conversion ratios. The authors proposed a simple method for choosing the measurement frequency to minimalize errors resulting from the spectral leakage and distortion caused by a lack of an anti-aliasing filter in the DDS generator. Additionally, a novel method for the AD5933 IC calibration was proposed. It consists in a mathematical compensation of the systematic error occurring in the argument of the value returned from the AD5933 IC as a result. The performance of the whole system is demonstrated in an exemplary measurement.
Źródło:
Metrology and Measurement Systems; 2015, 22, 1; 13-24
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impedance Sensors Made in PCB and LTCC Technologies for Monitoring Growth and Degradation of Pseudomonal Biofilm
Autorzy:
Chabowski, K.
Junka, A. F.
Piasecki, T.
Nowak, D.
Nitsch, K.
Smutnicka, D.
Bartoszewicz, M.
Moczała, M.
Szymczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/221326.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Pseudomonas aeruginosa
biofilm
interdigitated sensor
impedance spectroscopy
Opis:
The suitability of low-cost impedance sensors for microbiological purposes and biofilm growth monitoring was evaluated. The sensors with interdigitated electrodes were fabricated in PCB and LTCC technologies. The electrodes were golden (LTCC) or gold-plated (PCB) to provide surface stability. The sensors were used for monitoring growth and degradation of the reference ATCC 15442 Pseudomonas aeruginosa strain biofilm in invitro setting. During the experiment, the impedance spectra of the sensors were measured and analysed using electrical equivalent circuit (EEC) modelling. Additionally, the process of adhesion and growth of bacteria on a sensor’s surface was assessed by means of the optical and SEM microscopy. EEC and SEM microscopic analysis revealed that the gold layer on copper electrodes was not tight, making the PCB sensors susceptible to corrosion while the LTCC sensors had good surface stability. It turned out that the LTCC sensors are suitable for monitoring pseudomonal biofilm and the PCB sensors are good detectors of ongoing stages of biofilm formation.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 369-380
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Is upper gastrointestinal bleeding still a life-threatening condition?
Autorzy:
Janczak, D.
Marschollek, P.
Marschollek, K.
Owczarzak, M.
Bakowski, W.
Bakowska, K.
Chabowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1719.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Opolski. Instytut Nauk o Zdrowiu
Opis:
Background: Upper gastrointestinal bleeding is a common clinical problem and one of the main reasons for emergency hospitalization. It is associated with an overall mortality rate of 2% to 13%, despite advances in medical therapy. First-choice management is conservative treatment with endoscopic hemostasis. Aim of the study: The aim of the study was to examine the epidemiological and clinical characteristics of patients with upper gastrointestinal bleeding with a focus on the course of hospitalization based on the etiology Material and methods: A retrospective study was conducted in the Department of Surgery at the 4th Military Teaching Hospital in the years 2011–2016, comprising a total of 200 hospitalizations. 150 (75%) of the study group were men, and the mean age was 63.6±15.8 years. Results: Patients most frequently presented with melena (n=105; 53.1%) and hematemesis (n=79; 40%) or coffee ground vomiting (n=57; 28.7%). . 138 (69%) of hemorrhages were managed with endoscopic hemostasis, and in 43 (21.5%) of cases conservative treatment was adequate. In 12 (6%) of cases, laparotomy was the first-choice therapy and in 7 (3.5%) cases, surgery was performed after an attempt at endoscopic treatment had failed. The sources of bleeding were: gastric ulcer – 58 (29%), duodenal ulcer – 48 (24%), esophageal varices – 31 (15.5%), gastric tumor – 15 (7.5%), Mallory-Weiss syndrome – 10 (5%), and Dieulafoy’s lesion – 3 (1.5%). 16 (8%) of the hospitalizations were fatal. Conclusions: Upper gastrointestinal bleeding still has a high mortality rate (8%). It more frequently affects men and the elderly. Gastric and duodenal ulcers are the most common etiologies of bleeding. Esophageal varices and neoplasms are also a significant source of bleeding. Despite the progress in the pharmacological treatment of peptic ulcers, the complications resulting from gastrointestinal bleeding continue to be a serious clinical problem.
Źródło:
Medical Science Pulse; 2019, 13, 2
2544-1558
2544-1620
Pojawia się w:
Medical Science Pulse
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies