Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Borucki, S." wg kryterium: Autor


Tytuł:
Time-Frequency Analysis of Mechanical Vibrations of the Dry Type Power Transformer Core
Autorzy:
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/1493019.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The paper presents research results referring to the development of a non-invasive method of assessment of the power transformer core technical condition based on the analysis of the mechanical vibrations registered. It characterizes the power object under study, the measuring system used and the developed methodology of assessment of the core pressing degree using the vibroacoustic method. The original results of the time-frequency analysis of the vibroacoustic signals presented in the paper were obtained during switching on a real 800 kVA dry type power transformer in laboratory conditions. The analysis of the signals registered was carried out for three states of its operation: the core pressed by the manufacturer, the core with loose screws fixing the upper yoke and the core with separated upper yoke beams.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 571-574
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vibroacoustic Measurements in a Transient State οf Transformer Operation
Autorzy:
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/1795788.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The subject matter of this paper refers to the assessment of the technical condition of a power transformer core and windings based on vibroacoustic measurements taken during a transient operation state of the appliance diagnosed - at a transformer unit switch on. The paper presents preliminary results of the research work carried out, which aims at elaborating a new diagnostic and assessment method of the degree of the transformer core and winding pressing using the so-called modified vibroacoustic method. The paper characterizes the measurement path and the assessment method of the core and winding pressing degree based on the selected analyses of the vibroacoustic signal registered. The original research results presented in the paper were obtained at a real 400 kV A power transformer switch on in laboratory conditions - for a regular operation condition and for modeled core damage.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 277-280
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Descriptors of Acoustic Emission Signals Generated by Partial Discharges under Laboratory Conditions and in On-Site Electrical Power Transformer
Autorzy:
Kunicki, M.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176881.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
An acoustic emission method (AE) is widespread and often applied for partial discharge (PD) diagnostics, mainly due to its ease of application as well as noninvasiveness and relatively high sensitivity. This paper presents comparative analysis of AE signals measurement results archived under laboratory conditions as well as on-site actual AE signals generated by inside PDs in electrical power transformer during its normal service. Three different PD model sources are applied for laboratory research: point to point, multipoint to plate and surface type. A typical measuring set up commonly used for on-site transformer PD diagnostics is provided for the laboratory tasks: piezoelectric joint transducer, preamplifier, amplifier and measuring PC interface. During the on-site research there are three measuring tracks applied simultaneously. Time domain, time-frequency domain and statistical tools are used for registered AE signals analysis. A number of descriptors are proposed as a result of the analysis. In the paper, attempt of AE signals descriptors, archived under laboratory condition application possibilities for on-site PD diagnostics of power transformers during normal service is made.
Źródło:
Archives of Acoustics; 2016, 41, 2; 265-276
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical Possibilities of Reducing the Sound Pressure Level Emitted into the Environment by a Power Transformer
Autorzy:
Borucki, S.
Boczar, T.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177473.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
corrected sound pressure level
noise
modernization
Opis:
The subject presented in this paper refers to measurements and assessment of the corrected sound pressure level values (noise) occurring around a medium-power transformer. The paper presents the values of noise accompanying the operation of the power object before and after its modernization, which consisted in repeated core pressing and replacement of the cooling system. The main aim of the research work was the assessment of the influence of the repair work on the noise level emitted into the environment.
Źródło:
Archives of Acoustics; 2011, 36, 1; 49-56
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Clustering Methods for the Identification of Acoustic Emission Signals Generated by the Selected Form of Partial Discharge in Oil-Paper Insulation
Autorzy:
Borucki, S.
Łuczak, J.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/177657.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
insulation
power transformer
Opis:
The article presents the results concerning the use of clustering methods to identify signals of acoustic emission (AE) generated by partial discharge (PD) in oil-paper insulation. The conducted testing featured qualitative analysis of the following clustering methods: single linkage, complete linkage, average linkage, centroid linkage and Ward linkage. The purpose of the analysis was to search the tested series of AE signal measurements, deriving from three various PD forms, for elements of grouping (clusters), which are most similar to one another and maximally different than in other groups in terms of a specific feature or adopted criteria. Then, the conducted clustering was used as a basis for attempting to assess the effectiveness of identification of particular PD forms that modelled exemplary defects of the power transformer’s oil-paper insulation system. The relevant analyses and simulations were conducted using the Matlab estimation environment and the clustering procedures available in it. The conducted tests featured analyses of the results of the series of measurements of acoustic emissions generated by the basic PD forms, which were obtained in laboratory conditions using spark gap systems that modelled the defects of the power transformer’s oil-paper insulation.
Źródło:
Archives of Acoustics; 2018, 43, 2; 207-215
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of Acoustic Emission Signals Generated in On Load Tap Changer
Autorzy:
Cichoń, A.
Borucki, S.
Wotzka, D.
Powiązania:
https://bibliotekanauki.pl/articles/1199209.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The paper deals with mathematical modeling of acoustic emission signals which are generated in on load tap changers. In power engineering area acoustic emission method is commonly used for diagnosis purposes. Authors in their research works apply it for detection of defects occurring in on load tap changers, which are important elements of power transformers. The acoustic emission method is based on measurements performed by use of wideband piezoelectric transducers that are mounted on transformer tank surface. The registered signal is then analyzed in the time, frequency, and time-frequency domains or is evaluated with computer expert systems for diagnosis purposes. Depending on indicators device technical condition can be determined. The contribution given by the authors in this paper is proposal of a mathematical model, which describes envelope of the measured acoustic emission signal.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1396-1399
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of the Core Mechanical Construction Based on Vibroacoustic Measurements and Distribution of Temperature Field in Transformer Magnetic Circuit
Autorzy:
Borucki, S.
Cichon, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/1401874.pdf
Data publikacji:
2015-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
Subject matter of this article concerns the results of research works on the development and use of the vibroacoustic method to evaluate technical state of transformer cores. The article presents obtained measurement results of transformer mechanical vibration for two cases of its operation: with twisted and loosened core. In order to demonstrate negative effects of operating a transformer with a loosened core, this publication presents thermographic images showing temperature distribution on its magnetic core. The article characterises the examined transformer, employed measurement system and methodology of the completed experiment. The vibroacoustic and thermographic measurements were carried out during idle work of the transformer. Core vibration was registered for three measurement axes: 0X, 0Y and 0Z. Completed tests have proven that loosened screws pressing the core cause evident increase in the value of magnetic core vibration acceleration. At the same time, the temperature rises by more than 25%.
Źródło:
Acta Physica Polonica A; 2015, 128, 3; 306-309
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selecting Sensor for On Load Tap Changer Contacts Degree of Wear Diagnostics
Autorzy:
Cichoń, A.
Borucki, S.
Berger, P.
Powiązania:
https://bibliotekanauki.pl/articles/1399337.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
Results of scientific research works considering selection of measuring transducer applied for registration of acoustic emission signals generated by on load tap changers are presented in the paper. During the coupling process acoustic emission signals are generated by: the mechanical setup of tap changer, contacts operation, and other phenomena. For most on load tap changers types, the working medium is insulation oil in which the acoustic wave being formed propagates to the steal tank. There exists a possibility to register acoustic emission signals with a piezoelectric transducer attached to the outer tank surface or with a hydrophone immersed in the oil. Acoustic emission signal obtained in such manner contains information which describes operation of the power tap changer and the selector. A comparative analysis of acoustic emission signals generated by on load tap changers working under laboratory conditions, with applied measuring transducers with different transmittances, is presented in the paper. The comparative analysis was performed in order to determine their suitability for on load tap changers technical condition diagnosis. Based on the results achieved, one transducer which allows the registration of acoustic events generated during on load tap changers operation was selected.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 395-398
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Interference Signals Generated by Vibroacoustic Vibrations of Transformer Cores
Autorzy:
Boczar, T.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/1199078.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
79.60.Bm
42.79.Pw
52.80.Hc
Opis:
The article deals with the subject matter referring to the interference that may accompany measurements of vibroacoustic signals, generated by electric power transformers, taken by using the acoustic emission method under industrial conditions. Paper concerns measurement and analysis of internal, acoustic type disturbances, including the magnetostrictive vibrations of plate sets within the transformer core, caused by changes in the magnetic flux. Paper presents measurement results of acoustic interfering signals and results of analyses made in the frequency and time-frequency domains. Power spectral density, MUSIC pseudospectra, two- and three-dimensional short time Fourier transform spectrograms, continuous wavelet transform scalograms, discrete wavelet transform, and quantities of energy transferred are included in the paper.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1355-1359
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Optical Radiation Generated by Partial Discharges on Insulators
Autorzy:
Frącz, P.
Boczar, T.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/1366318.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
79.60.Bm
42.79.Pw
52.80.Hc
Opis:
Results of measurements of optical radiation emitted by partial and complete electrical discharges occurring on a bushing insulator model placed in air are presented in the article. Registration was performed using a spectrophotometer, enabling for measurement of optical radiation in the range from 270 to 1700 nm. Detailed characteristics of spectrophotometer are presented in our previous paper. The primary objective of the laboratory tests was to evaluate the impact of supply voltage changes in the range from 0 to 0.99 $U_{b}$ (breakdown voltage) on the intensity and spectral character of the optical radiation emitted by partial discharges generated on the porcelain insulation surface of the bushing insulator. In the scope of studies analyzes of the effects of voltage changes on the obtained spectral waveforms were performed, whereby voltage increase and reduction was examined separately. Additionally, measurements and analyzes carried out included impact estimation of the time period as the voltage was applied to the high-voltage electrodes on the course of optical phenomena related to the generation of partial discharges.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1360-1366
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the Acoustic Emission Method for Diagnosis of On-Load Tap Changer
Autorzy:
Majchrzak, H.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176624.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
This paper provides an example of the application of the acoustic emission (AE) method for the diagnosis of technical conditions of a three-phase on-load tap-changer (OLTC) GIII type. The measurements were performed for an amount of 10 items of OLTCs, installed in power transformers with a capacity of 250 MVA. The study was conducted in two different OLTC operating conditions during the tapping process: under load and free running conditions. The analysis of the measurement results was made in both time domain and time-frequency domain. The description of the AE signals generated by the OLTC in the time domain was performed using the analysis of waveforms and determined characteristic times. Within the time-frequency domain the measured signals were described by short-time Fourier transform spectrograms.
Źródło:
Archives of Acoustics; 2017, 42, 1; 29-35
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of the Non-Concurrent Operation of the On-Load Tap Changer Contacts by the Acoustic Emission Method
Autorzy:
Cichoń, A.
Borucki, S.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177044.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
on-load tap changers
acoustic emission method
Opis:
On-load tap changers (OLTC) are some of the main transformer elements that make voltage adjustment in a power network possible. Their failures often cause shutdowns of distribution transformers. The paper presents research work aimed at the assessment of the technical condition of OLTCs by the acoustic emission method (EA). This method makes the OLTC diagnosis possible without the need of disconnecting the transformer from the system. The measurements were taken in laboratory conditions. The influence on the operation non-concurrence of the power tap changer contacts on the AE registered signals has been investigated. The signals registered were subjected to analyses in the time and time-frequency domains. The result analysis in the time domain was carried out using the Hilbert transform and calculating characteristic times for the particular runs. A short-time Fourier transform was used for the assessment of results in the time-frequency do- main.
Źródło:
Archives of Acoustics; 2011, 36, 4; 823-830
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Technical Condition of the Active Part of the High Power Transformer Based on Measurements and Analysis of Vibroacoustic Signals
Autorzy:
Borucki, S.
Cichoń, A.
Majchrzak, H.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/176397.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vibration
vibroacoustic method
core
power transformer
transformer diagnostics
Opis:
This article presents the results of research connected with the development and industrial use of vibroacoustic methods for the evaluation of the technical condition of the active part of transformers. The article presents the results of the analysis of vibrations generated by the high power transformer in which a defect was found on the basis of tests of oil carried out using the chromatography tests. In order to confirm the damage of the active part of this transformer, vibroacoustic measurements were performed in three states of its operation. The measurement using the classical vibroacoustic method included the registration of vibrations at the idle speed and during the load operation of the transformer. The original diagnostic method, so-called the modified vibroacoustic method, was also used during the measurement. The analysis of signals recorded using the classical vibroacoustic method was carried out in the frequency domain by indicating the amplitude of even harmonic vibrations. However, the analysis of signals measured during the commissioning of the transformer was conducted in the time-frequency domain using the short-time Fourier transform (STFT), continuous wavelet transform (CWT), and discrete wavelet transform (DWT). On the basis of the analysis of the results obtained it was stated that the increased level of vibrations of this transformer is a consequence of the loss of rigidity of the mechanical structure of its core.
Źródło:
Archives of Acoustics; 2017, 42, 2; 313-320
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Repeatability Estimation for Vibration Measurement Results of Power Transformer Core
Autorzy:
Borucki, S.
Cichon, A.
Skubis, J.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/1198972.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The subject matter of this paper refers to the diagnostics of a transformer core, based on measurements and analysis of vibroacoustic signals registered during their normal operation. The paper presents results of the research aimed to evaluate the repeatability of vibration measurements for power transformer core. Recording of vibroacoustic signals was performed under laboratory conditions on dry-insulated transformers. The study concerned evaluation of changes in vibroacoustic indicators of the transformer core during operation with a turned and loosened core. Conclusions from the measurement results were drawn on the basis of the parametric test of significance derived from the variance analysis for many means of single classification basing on the Fisher-Snedecor F-distribution.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1299-1302
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solving a Set of Spherical Equations for Localization of Partial Discharges by Acoustic Emission Method
Autorzy:
Boczar, T.
Witkowski, P.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/1401873.pdf
Data publikacji:
2015-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
This article deals with the subject matter of improvement of the acoustic emission methods used for location of partial discharges, which may occur inside power transformer insulation systems. Analytical solutions of spherical equations for location of partial discharge generation using the acoustic method were shown in detail. Presented in the article method of solving the assumed equations is based on the analytical method and matrix notation. Theoretical considerations and later the measurement-based verification refer to the use of the triangulation method for location of the occurrence of partial discharges. The results of the scientific and research works that have been presented in this article are the next stage of research aimed at development of on-line diagnosis system for insulation systems of electrical equipment, allowing for detection, measurement and identification of forms and locations of partial discharges using the acoustic emission method.
Źródło:
Acta Physica Polonica A; 2015, 128, 3; 299-305
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies