Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Żak, Anna" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Assessment of shoulder mobility in women over 60 years of age after one-sided mastectomy
Ocena funkcji barku u kobiet po 60. roku życia leczonych z powodu raka piersi
Autorzy:
Włoch, Anna
Żak, Marek
Opuchlik, Anna
Biskup, Małgorzata
Fabiś, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/1798677.pdf
Data publikacji:
2016
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
mastectomy
shoulder
muscle strength
Range of Motion (ROM)
aged
mastektomia
bark
siła mięśniowa
zakres ruchomości
osoby starsze
Opis:
The overall risk of contracting various diseases, including breast cancer, increases with age. An on-going process of population ageing challenges modern physiotherapy with the need to have functional capacity in older people appreciably enhanced. The issue of anthropometric assessment of the range of motion and shoulder muscle strength is presently much underrated in the physical rehabilitation management of women patients after radical one-sided mastectomy. The study aimed to assess the functional mobility of a shoulder expressed as a range of motion, in conjunction with the assessment of shoulder muscle strength, in women patients over 60 years of age after radical one-sided mastectomy. The study comprised 24 patients (mean age 65 years) recruited from the Department of Rehabilitation, Holy Cross Cancer Centre, Kielce. All patients had undergone modifi ed radical mastectomy using the Madden technique, and an adjuvant therapy. The shoulder range of motion, i.e. flexion, abduction, internal and external rotation, was evaluated by a goniometer. Elevation, protraction and retraction movements were evaluated using an anthropometric device. A dynamometer was applied to assess the strength of select muscle groups within the shoulder during elevation, protraction and retraction motions. Statistical analysis was made with the aid of STATISTICA 12.0 software, having adopted a 0.05 alpha level as statistically signifi cant. The movements of fl exion, abduction and external rotation of the upper extremity were signifi cantly reduced on the mastectomy side. The range of motion and muscle strength during shoulder elevation, protraction and retraction were significantly diminished on the operated side (12% - 14%), compared to the non-operated one. 1. Functional mobility of the shoulder was signifi cantly reduced on the mastectomy side. 2. Results of the present study highlight the need to extend the scope of rehabilitation regimens offered to older women after radical one-sided mastectomy.
Wstęp: Z wiekiem wzrasta ryzyko zachorowania na różne choroby, w tym raka piersi. Postępujący proces starzenia się społeczeństw wymaga od współczesnej fizjoterapii zwiększenia sprawności funkcjonalnej osób starszych. Problem antropometrycznego pomiaru zakresu ruchu oraz siły mięśni barku jest słabo dostrzegany w procesie usprawniania pacjentek po mastektomii. Cel pracy: Celem badania była ocena funkcji barku wyrażonej w zakresie ruchu i siły mięśniowej u pacjentek po 60. r.ż., po mastektomii. Materiał i metody: Do badania zakwalifikowano 24 pacjentki (średnia wieku: 65 lat) w Zakładzie Rehabilitacji Świętokrzyskiego Centrum Onkologii w Kielcach. Wszystkie pacjentki były poddane zmodyfikowanej radykalnej mastektomii metodą Maddena oraz odpowiedniemu leczeniu uzupełniającemu. W Zakładzie Rehabilitacji zbadano zakres ruchomości stawów ramienno-łopatkowych podczas zgięcia, odwiedzenia, rotacji wewnętrznej oraz rotacji zewnętrznej za pomocą goniometru. Ruchy unoszenia, wysuwania do przodu (protrakcja) oraz cofania (retrakcja) barku oceniano za pomocą antropometru. Dynamometrem zbadano siłę wybranych grup mięśni barku podczas unoszenia, wysuwania do przodu oraz cofania. Analizę statystyczną wykonano za pomocą pakietu STATISTICA 12.0, przyjęto poziom alfa = 0,05. Wyniki: Ruchy zgięcia, odwodzenia i rotacji zewnętrznej kończyny górnej były istotnie statystycznie ograniczone po stronie operowanej piersi. Zakres ruchu oraz siła mięśni barku podczas unoszenia, wysuwania do przodu i cofania były istotnie statystycznie mniejsze po stronie wykonanej mastektomii (12%-14%) w stosunku do strony zdrowej. Wnioski: 1. Funkcja barku u kobiet po 60. roku życia, po stronie operowanej piersi jest znacząco ograniczona. 2. Przedstawione badania wskazują na konieczność poszerzenia zakresu rehabilitacji chorych w starszym wieku po leczeniu raka piersi.
Źródło:
Medical Rehabilitation; 2016, 20(4); 13-16
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long-distance Running and its Effects on Cardiorespiratory Adaptation and Physiological Strain in Marathon Runners
Autorzy:
Przybyła, Katarzyna
Żebrowska, Aleksandra
Posmysz, Anna
Manowska, Beata
Pokora, Ilona
Żak, Agata
Powiązania:
https://bibliotekanauki.pl/articles/1054890.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
marathon
physiological strain index
spirometry
Opis:
Popularity of long-distance running has increased as well as number of female and male marathon runners. Whilst research into physiological characteristics of endurance trained athletes has significantly increased there are only few studies on the risk factors for respiratory failure in marathon runners. Therefore, the aim of the study was to evaluate the differences in respiratory function and the physiological strain in the response to exercise stress in marathon runners. Twenty three subjects (aged 36.1 ±11.6 years) participated in a marathon running. Prior to the run and after its completion, body mass and composition, spirometry and body temperature were measured. Based on pre- and post-run temperature and changes in heart rate, the physiological strain index (PSI) was calculated. Long-distance running significantly decreased the temperature of body surfaces (p < 0.05); no significant effects were observed regarding aural canal temperature and physiological strain index (PSI). Compared to resting values, post-marathon spirometry revealed a significant decrease in post-marathon forced expiratory volume (p < 0.05), peak expiratory flow (p < 0.05) and maximal expiratory flow values (p < 0.05). In conclusion, the long-distance running results in functional changes within the respiratory system which may limit the adaptive potential and decrease exercise tolerance.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2016, 13, 1; 81-87
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Carrier-state of D allele in ACE gene insertion/deletion polymorphism is associated with coronary artery disease, in contrast to the C677→T transition in the MTHFR gene.
Autorzy:
Żak, Iwona
Niemiec, Paweł
Sarecka, Beata
Balcerzyk, Anna
Ciemniewski, Zbigniew
Rudowska, Ewa
Dyląg, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/1043632.pdf
Data publikacji:
2003
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
angiotensin converting enzyme gene (ACE)
coronary artery disease
methylenetetrahydrofolate reductase gene (MTHFR)
polymorphisms
Opis:
Angiotensin I-converting enzyme (ACE), which plays an important role in blood pressure regulation, and methylenetetrahydrofolate reductase (MTHFR) involved in homocysteine metabolism belong to a large group of polypeptides which may be potential risk factors for atherosclerosis and coronary artery disease (CAD). To assess whether polymorphisms of the genes encoding these peptides are associated with CAD in Silesian we conducted a study among 68 individuals suffering from CAD (including 52 cases after myocardial infarction), 51 subjects with positive family history of CAD and 111 controls. We analysed the distribution of genotypes and allele frequencies of the insertion/deletion (I/D) polymorphism in the ACE gene using PCR amplification, and the C677→T polymorphism in the MTHFR gene using PCR-RFLP analysis. We found that D allele frequency was significantly higher in CAD patients (61%) than in controls (43%) (P = 0.001, OR = 2.06). The D allele carriers (DD + ID genotypes) were more frequent in the CAD patients (85%) compared to control group (65%) (P = 0.003, OR = 3.14), whereas the familial CAD risk group shows the highest frequency of the ID genotype (57% vs 43% in controls). In contrast, the MTHFR polymorphism does not seem to be associated with the disease. Our data indicate that in Silesian CAD patients the disease is strongly associated with carrier-state of the ACE D allele, but not with the C677→T transition in the MTHFR gene.
Źródło:
Acta Biochimica Polonica; 2003, 50, 2; 527-534
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of p-type contacts to InGaN-based laser diodes and light emitting diodes grown by plasma assisted molecular beam epitaxy
Autorzy:
Nowakowski-Szkudlarek, Krzesimir
Muziol, Grzegorz
Żak, Mikolaj
Hajdel, Mateusz
Siekacz, Marcin
Feduniewicz-Żmuda, Anna
Skierbiszewski, Czesław
Powiązania:
https://bibliotekanauki.pl/articles/173471.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
gallium nitride
molecular beam epitaxy
contacts
Opis:
We investigated the influence of the In0.17Ga0.83N:Mg contact layer grown by plasma assisted molecular beam epitaxy on the resistivity of p-type Ni/Au contacts. We demonstrate that the Schottky barrier width for p-type contact is less than 5 nm. We compare circular transmission line measurements with a p-n diode current-voltage characteristics and show that discrepancies between these two methods can occur if surface quality is deteriorated. It is found that the most efficient contacts to p-type material consist of In0.17Ga0.83N:Mg contact layer with Mg doping levelas high as 2 × 1020 cm–3.
Źródło:
Optica Applicata; 2020, 50, 2; 323-330
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies