Tytuł:
System-level approaches to power efficiency in FPGA-based designs (data reduction algorithms case study)
Autorzy:
Czapski, P. P.
Śluzek, A.
Powiązania:
https://bibliotekanauki.pl/articles/384769.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
power awareness
FPGA
system-level
Handel-C
data reduction
Opis:
In this paper we present preliminary results on systemlevel analysis of power efficiency in FPGA-based designs. Advanced FPGA devices allow implementation of sophisticated systems (e.g. embedded sensor nodes). However, designing such complex applications is prohibitively expensive at lower levels so that, moving the designing process to higher abstraction layers, i.e. system-levels of design, is a rational decision. This paper shows that at least a certain level of power awareness is achievable at these higher abstractions. A methodology and preliminary results for a power-aware, system-level algorithm partitioning is presented. We select data reduction algorithms as the case study because of their importance in wireless sensor networks (WSN's). Although, the research has been focused on WSN applications of FPGA, it is envisaged that the presented ideas are applicable to other untethered embedded systems based on FPGA's and other similar programmable devices.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2011, 5, 2; 49-59
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Location-based Power Control Mechanism for D2D Communication Underlaying a Cellular System
Autorzy:
Rodziewicz, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/24200756.pdf
Data publikacji:
2023
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
context-awareness
device-to-device
frequency reuse-1
power control
Opis:
The paper presents a location-based approach to controlling the power of device-to-device (D2D) underlay of a frequency reuse-1 cellular system. The system allows for direct communication to share uplink resources with cellular users. As a result, both D2D and cellular users are experiencing additional interferences in the system. By controlling the output power of the devices, these interferences can be mitigated and the performance of the network can be improved in terms of better spectral and energy efficiency. The proposed location-based target signal-to-interference ratio power control scheme for D2D communications utilizes information about users' locations to estimate the interference level experienced by the receiver of the direct link. Based on this estimation, an appropriate transmit power can be determined. The performance of the proposed power control solution is investigated via system level simulations.
Źródło:
Journal of Telecommunications and Information Technology; 2023, 3; 49--53
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing Situation Awareness Network for the Electrical Power Infrastructure
Badanie sieci świadomości sytuacyjnej dla infrastruktury elektroenergetycznej
Autorzy:
Leszczyna, R.
Małkowski, R.
Wróbel, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/396816.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
electric grid
cyber security
situational awareness
testing
sieć energetyczna
bezpieczeństwo cybernetyczne
świadomość sytuacyjna
filtrowanie
Opis:
The contemporary electrical power infrastructure is exposed to new types of threats. The cause of such threats is related to the large number of new vulnerabilities and architectural weaknesses introduced by the extensive use of Information and Communication Technologies (ICT) in such complex critical systems. The power grid interconnection with the Internet exposes the grid to new types of attacks, such as Advanced Persistent Threats (APT) or Distributed-Denial-of- Service (DDoS) attacks. When addressing this situation the usual cyber security technologies are prerequisite, but not sufficient. To counter evolved and highly sophisticated threats such as the APT or DDoS, state-of-the-art technologies including Security Incident and Event Management (SIEM) systems, extended Intrusion Detection/Prevention Systems (IDS/IPS) and Trusted Platform Modules (TPM) are required. Developing and deploying extensive ICT infrastructure that supports wide situational awareness and allows precise command and control is also necessary. In this paper the results of testing the Situational Awareness Network (SAN) designed for the energy sector are presented. The purpose of the tests was to validate the selection of SAN components and check their operational capability in a complex test environment. During the tests’ execution appropriate interaction between the components was verified.
Współczesne systemy elektroenergetyczne są narażone na nowe rodzaje zagrożeń. Są one spowodowane lukami w zabezpieczeniach oraz słabościami architektonicznymi związanymi z szerszym zastosowaniem technologii teleinformatycznych (ICT) w tych systemach. Połączenie sieci elektroenergetycznych z Internetem naraża je na nowego rodzaju niebezpieczeństwa, takie jak ataki APT (ang. Advanced Persistent Threats) lub rozproszona odmowa usługi (ang. Distributed Denial-of-Service – DDoS). W tej sytuacji zastosowanie tradycyjnych technologii bezpieczeństwa informatycznego staje się warunkiem koniecznym, ale niewystarczającym. Aby przeciwdziałać rozwiniętym i wysoce zaawansowanym zagrożeniom, konieczne jest zastosowanie najnowocześniejszych technologii, np. systemów zarządzania informacjami i zdarzeniami bezpieczeństwa (ang. Security Incident and Event Management – SIEM), rozbudowanych systemów wykrywania włamań lub zapobiegania włamaniom (ang. Intrusion Detection/Prevention Systems – IDS/IPS) oraz układów Trusted Platform Module (TPM). Niezbędne jest także wdrażanie w infrastrukturze teleinformatycznej sieci świadomości sytuacyjnej, która umożliwia precyzyjne monitorowanie i wykrywanie zagrożeń. W artykule przedstawiono projekt oraz wyniki przeprowadzonych testów sieci świadomości sytuacyjnej (ang. Situational Awareness Network – SAN) przeznaczonej dla sektora energetycznego. Celem testów było potwierdzenie doboru komponentów SAN i sprawdzenie ich możliwości operacyjnych w złożonym środowisku testowym. W trakcie przeprowadzonych eksperymentów zweryfikowano poprawne działanie sieci SAN.
Źródło:
Acta Energetica; 2016, 3; 81-87
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies