Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "patryk, J." wg kryterium: Wszystkie pola


Wyświetlanie 1-3 z 3
Tytuł:
The first evidence of a host-to-parasite mitochondrial gene transfer in Orobanchaceae
Autorzy:
Kwolek, Dagmara
Denysenko-Bennett, Magdalena
Góralski, Grzegorz
Cygan, Magdalena
Mizia, Patryk
Piwowarczyk, Renata
Szklarczyk, Marek
Joachimiak, Andrzej J.
Powiązania:
https://bibliotekanauki.pl/articles/952048.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
orobanche
hgt
horizontal gene transfer
atp6
mitochondrion
Opis:
Several parasitic plants are known to have acquired mitochondrial genes via a horizontal transfer from their hosts. However, mitochondrial gene transfer in this direction has not yet been found in the parasite-rich family Orobanchaceae. Based on a phylogenetic analysis of the mitochondrial atp6 gene in selected species of Orobanche s.l., we provide evidence of a host-to-parasite transfer of this gene in O. coerulescens, which is a Eurasiatic species that parasitises Artemisia (Asteraceae). We did not find the original Orobanche atp6 gene in this species, which suggests that it has been replaced by a gene that was acquired from Asteraceae. In addition, our data suggest the occurrence of a second HGT event in the atp6 sequence – from Asteraceae to Phelipanche. Our results support the view that the transfer of genetic material from hosts to parasites influences the mitochondrial genome evolution in the latter.
Źródło:
Acta Biologica Cracoviensia. Series Botanica; 2017, 59, 1
0001-5296
Pojawia się w:
Acta Biologica Cracoviensia. Series Botanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Graphene on quartz modified with rhenium oxide as a semitransparent electrode for organic electronics
Autorzy:
Krukowski, Paweł
Piskorski, Michał
Udovytska, Ruslana
Kowalczyk, Dorota A.
Lutsyk, Iaroslav
Rogala, Maciej
Dąbrowski, Paweł
Kozłowski, Witold
Łuszczyńska, Beata
Jung, Jarosław
Ulański, Jacek
Matuszek, Krzysztof
Nadolska, Aleksandra
Przybysz, Przemysław
Ryś, Wojciech
Toczek, Klaudia
Dunal, Rafał
Krempiński, Patryk
Czerwińska, Justyna
Ster, Maxime Le
Skulimowski, Marcin
Kowalczyk, Paweł J.
Powiązania:
https://bibliotekanauki.pl/articles/2174856.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
graphene
rhenium oxide
anode
organic light-emitting diode
Opis:
The presented research shows that commercially available graphene on quartz modified with rhenium oxide meets the requirements for its use as a conductive and transparent anode in optoelectronic devices. The cluster growth of rhenium oxide enables an increase in the work function of graphene by 1.3 eV up to 5.2 eV, which guarantees an appropriate adjustment to the energy levels of organic semiconductors used in organic light-emitting diode devices.
Źródło:
Opto-Electronics Review; 2022, 30, 4; art. no. e141953
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental safety aspects of using UHF RFID systems in hospitals
Aspekty środowiskowego bezpieczeństwa wykorzystania systemów UHF RFID w szpitalach
Autorzy:
Zradziński, Patryk
Karpowicz, Jolanta
Gryz, Krzysztof
Suarez, Oscar J.
Trillo, Angeles M.
Hernandez, Jose A.
Miguel-Bilbao de, Silvia
Suarez, Samuel D.
Celaya-Echarri, Mikel
Azpilicueta, Leyre
Falcone, Francisco
Ramos, Victoria
Powiązania:
https://bibliotekanauki.pl/articles/2146754.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
biomedical engineering
environmental engineering
occupational exposure
public health
AIMD
Internet of things
inżynieria biomedyczna
inżynieria środowiska
narażenie zawodowe
zdrowie publiczne
internet rzeczy
Opis:
Various applications of Radio Frequency IDentification (RFID) technology in the medical environment are characterised. The electromagnetic field (EMF) emitted by RFID handheld readers (RFID guns) is characterised and evaluated with respect to humans exposure metrics – the strength of the electric field affecting anyone present near various UHF (ultra-high frequency) RFID guns and the specific absorption rate (SAR) values in their body. UHF RFID systems are the most popular of such systems used in hospitals. The performed studies indicate that the EMF exposure level near the RFID gun antenna and SAR values (a measure of the thermal effects of EMF exposure) caused by exposure from the RFID reader may exceed the limits of the electric field and SAR issued by international guidelines or legislation. Potentially excessive exposure to EMF emitted by UHF RFID readers is not limited to the user of the device, but may also apply to patients or bystanders. Only UHF RFID guns with an EMF emission lower than 1 W may be considered as an insignificant source of human exposure. The use of readers with a radiated power exceeding 1 W requires the evaluation of the EMF level using measurements, and also the evaluation of SAR by numerical modelling in the case of their use in close proximity to humans. In all cases, insufficient electromagnetic immunity of electronic devices (including medical implants) should be considered near RFID guns at least up to half of the reading range away from the RFID reader. The electromagnetic hazards related to the use of RFID guns may be limited by relevant preventive measures, as shown in this paper, together with the principles of an in-situ evaluation of electromagnetic hazards near the UHF RFID guns.
Scharakteryzowano różne zastosowania technologii identyfikacji radiowej (RFID) w środowisku medycznym. Pole elektromagnetyczne emitowane przez ręczne czytniki RFID (RFID guns) zostało scharakteryzowane i ocenione w odniesieniu do miar narażenia ludzi – natężenia pola elektrycznego oddziałującego na osoby znajdujące się w pobliżu różnych czytników RFID UHF (ultrawysokiej częstotliwości) i współczynnika SAR w ich ciele. System UHF RFID jest najpopularniejszym z systemów RFID użytkowanych m.in. w szpitalach. Przeprowadzone badania wskazują, że poziom ekspozycji na pole elektromagnetyczne w pobliżu anteny ręcznego czytnika RFID i wartości SAR (miara skutków termicznych oddziaływania pola elektromagnetycznego) spowodowane tą ekspozycją mogą przekraczać limity, opublikowane w zleceniach międzynarodowych lub przepisach. Nadmierna ekspozycja na pole elektromagnetyczne emitowane przez czytniki RFID UHF może dotyczyć nie tylko użytkownika urządzenia, ale również pacjenta lub osoby postronnej. Tylko ręczne czytniki RFID UHF o emisji pola elektromagnetycznego poniżej 1 W można uznać za nieistotne źródło narażenia ludzi. Korzystanie z czytników o mocy przekraczającej 1 W wymaga oceny poziomu pola elektromagnetycznego za pomocą pomiarów, a również oceny SAR za pomocą modelowania numerycznego w przypadku ich użycia w bezpośredniej bliskości ludzi. We wszystkich przypadkach niewystarczającą odporność elektromagnetyczną urządzeń elektronicznych (w tym implantów medycznych) należy rozważyć w pobliżu czytników RFID co najmniej do odległości od czytnika RFID równej połowie jego zasięgu odczytu. Zagrożenia elektromagnetyczne związane z używaniem ręcznych czytników RFID mogą być ograniczone przez odpowiednie środki ochronne, jak pokazano w tym artykule, wraz z zasadami oceny zagrożeń elektromagnetycznych in-situ w pobliżu ręcznych czytników UHF RFID.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 2; 133--140
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies