Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "orthopaedic implant" wg kryterium: Wszystkie pola


Wyświetlanie 1-3 z 3
Tytuł:
Preliminary evaluation of selected biologic properties of TiO2 and SiO2 layers on metallic substrates
Autorzy:
Urbański, W.
Dragan, S.
Gębarowska, E.
Dzięgiel, P.
Krzak-Roś, J.
Miller, M.
Pezowicz, C.
Będziński, R.
Powiązania:
https://bibliotekanauki.pl/articles/284506.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
sol-gel coating
fibroblast
cytotoxicity
orthopaedic implant
Opis:
Despite of applying modern biomaterials during constructing long term orthopaedic implants, in clinical practice there are still present wide range of complications, particularly concerning matter of implant - tissue interactions. Since interaction between implant and living tissue depends mainly on biomaterial surface features, we decided to modify orthopaedic alloys to improve their biological properties. The object of this experiment was in vitro evaluation of selected biological properties, particularly cytotoxicity of titanium alloy and 316L stainless steel substrates coated with SiO2 or TiO2 thin films. The coatings were synthesized by sol-gel method. Each samples was placed into mouse fibroblast culture. The cultures in presence of tested materials were maintained for three days. We found no distinct toxic effect of tested biomaterials. We noticed increase of fibroblast proliferation in cultures with uncoated titanium and particularly SiO2 coated titanium plates.
Źródło:
Engineering of Biomaterials; 2010, 13, no. 96-98; 129-133
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of a pulsed magnetic field on selected polymer implant materials
Autorzy:
Szponder, Tomasz
Stodolak-Zych, Ewa
Polkowska, Izabela
Sobczyńska-Rak, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/306606.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pole magnetyczne
biomateriały
implant ortopedyczny
magnetic field
biomaterials
orthopaedic implants
Opis:
Physiotherapy with the use of pulsed magnetic fields is one of the methods of activating the processes of bone healing and regeneration. Exposing materials serving as membranes in guided bone regeneration (GBR) or guided tissue regeneration (GTR) to magnetic fields is an effective model that allows to monitor changes in the material under the influence of the magnetic field. Methods: Materials engineering methods were used to verify the extent of material degradation resulting from magnetic field exposure in an aqueous environment. Changes in surface morphology were observed under an optical microscope and a scanning electron microscope (SEM). Changes in surface wettability were analysed in relation to the direct contact angle. Chemical structural changes were verified with the use of infrared spectroscopy (FTIR-ATR). Results: The PCL-based membrane materials underwent relatively moderate surface degradation (altered contact angle, changes in surface morphology), but the absence of observable FTIR-ATR spectral shifts evidenced material stability under the influence of magnetic field. More extensive degradation processes were observed in the case of PLDLA-based materials, whose surface character changed from hydrophilic to hydrophobic. The spectra revealed enhanced intensity of the chain terminal groups, provided that modifiers (nanometric SiO2 and TCP (water reservoir)) were present in the polymer matrix. Conclusions: The extent degradation in the polymer membrane was primarily dependent on the presence of aqueous environment, while the influence of the magnetic field on the analysed membrane materials was negligible. Therefore, GBR/GTR membrane implants can be considered to remain stable during rehabilitation with the use of alternating magnetic field.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 1; 87-96
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
contact problems with friction, adhesion and wear in orthopaedic biomechanics. Part I - general developments
Autorzy:
Rojek, J.
Telega, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/279902.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
bone-implant interface
contact
adhesion
friction
Opis:
The present paper is a continuation of the contribution by Rojek and Telega (1999). An alternative adhesion law is used to the study of the bone-implant interface. Various problems related to the bone-implant interface are discussed.
Zagadnienia kontaktowe z tarciem, adhezją i zużyciem w biomachanice ortopedycznej. Część I - Rozważania ogólne. Niniejsza praca stanowi kontynuację wcześniejszej pracy autorów, por. Rojek i Telega (1999). Zastosowano alternatywny model adhezji dla opisu interfazy kość-implant. Przedyskutowano równierz szereg zagadnień związanych z tą interfazą.
Źródło:
Journal of Theoretical and Applied Mechanics; 2001, 39, 3; 655-677
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies