Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "gamma tomography" wg kryterium: Wszystkie pola


Wyświetlanie 1-5 z 5
Tytuł:
A virtual laboratory for radiotracer and sealed-source applications in industry
Autorzy:
Mohammed, Mohammed Siddig H.
Banoqitah, Essam M.
Elmoujarkach, Ezzat
Alhawsawi, Abdulsalam M.
Djouider, Fathi
Powiązania:
https://bibliotekanauki.pl/articles/1841639.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
sealed sources
radiotracers
industrial gamma tomography
simulation
GATE
Opis:
Radioactive sealed sources and radiotracer techniques are used to diagnose industrial process units. This work introduces a workspace to simulate four sealed sources and radiotracer applications, namely, gamma scanning of distillation columns, gamma scanning of pipes, gamma transmission tomography, and radiotracer fl ow rate measurements. The workspace was created in Geant4 Application for Tomographic Emission (GATE) simulation toolkit and was called Industrial Radioisotope Applications Virtual Laboratory. The fl exibility of GATE and the fact that it is an open-source software render it advantageous to radioisotope technology practitioners, educators, and students. The comparison of the simulation results with experimental results that are available in the literature showed the effectiveness of the virtual laboratory.
Źródło:
Nukleonika; 2021, 66, 1; 21-27
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gamma-ray computed tomography as a tool to evaluate porosity changes along depth for surface crusted soils
Autorzy:
Pires, L. F.
Bacchi, O. O. S.
Reichardt, K.
Dias, N. M. P.
Powiązania:
https://bibliotekanauki.pl/articles/146838.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
gamma-ray attenuation
soil density
soil structure
soil surface sealing
241 Am
applied nuclear physics
gamma tomography
Opis:
Assessment of changes in porosity (ö) along depth for soils with surface crusting is difficult because conventional soil physical investigation tools are destructive and usually require a long period of time for preparation and analysis of the samples. Computed tomography (CT) has frequently been used as a method to evaluate soil structure in a nondestructive, sensitive, and rapid manner. CT data can be used for measuring at a millimetric scale changes in ö along depth for soils with surface crusting. The main objective of this work was to investigate the sensibility of the gamma-ray CT to assess soil structural changes along depth in samples presenting structural crust. CT images were taken with a first generation scanner of 1.14 mm resolution along eight different soil layers within the 0 28 mm depth. Porosity increased along depth up to the 14 17.5 mm layer. Through the analysis of the ö distribution of each layer it was possible to show that the sealed surface layer presented ö values of approximately 30%, while the other layers were greater than 30% up to 60% (macropore regions). The sealing crust thickness was estimated to be in the range of 2.3 3.5 mm.
Źródło:
Nukleonika; 2007, 52, 3; 125-131
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gamma-ray computed tomography SCANNERS for applications in multiphase system COLUMNs
Autorzy:
Calvo, W. A. P.
Hamada, M. M.
Sprenger, F. E.
Vasquez, P. A. S.
Rela, P. R.
Martins, J. F. T.
de Matos Pereira, J. C. S.
Omi, N.
de Mesquita, C. H.
Powiązania:
https://bibliotekanauki.pl/articles/148082.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
industrial computed tomography
multiphase flow systems
non-destructive testing
gas absorption column
industrial process optimization
packed distillation columns
scanning systems
Opis:
Gamma-ray tomography experiments have been carried out to detect spatial patterns in the porosity, in a 0.27 m diameter packed steel column using a first generation computed tomography (CT) system. The CT scanner consists of a NaI(Tl) detector 5.08 cm in diameter, and an encapsulated 137Cs (3.7 GBq) radioactive source, located opposite to the center of the detector. The detector and the source, mounted on a fixed support and the column, can rotated and dislocate by two stepping motors controlled through a microprocessor. Different sizes of stainless steel Raschig rings (12.6, 37.9 and 76 mm) have been examined. The primary objective of this work is to detect spatial patterns and statistical information on porosity variation in packed distillation columns. Horizontal scans, at different vertical positions of the packed bed were made for each size of Raschig rings. Radial porosity variation within the packed bed has been determined. This study has demonstrated that the porosity and its spatial distribution in a metallic packed column can be measured with adequate spatial resolution using the gamma-ray tomography technique. After validation of this first generation CT, the turntable design to rotate and dislocate the 60Co or 137Cs sealed gamma-ray sources and multidetector array for the third generation industrial computed tomography was also developed.
Źródło:
Nukleonika; 2009, 54, 2; 129-133
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Soil porosity distribution representative elementary area analyzed through gamma-ray computed tomography
Autorzy:
Ferreira, T.R.
Pires, L.F.
Powiązania:
https://bibliotekanauki.pl/articles/25444.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Opis:
This study aims to use γ-ray computed tomography images to define the representative elementary area of the soil porosity distribution. Different textured soils from Southeast Brazil and different schemes of areas were analyzed. The image acquisition was performed in 2006 using a first generation γ-ray computed tomography system equipped with 241Am radioactive source. Consecutive increasing areas located at the center (scheme 1), the inferior (scheme 2) and superior (scheme 3) borders of the sample computed tomography image, with size areas ranging from 1.2 to 678.8 mm², were selected. The full width at a half maximum parameter was used to describe the samples soil porosity distribution and mathematical analysis concepts were adopted to define the representative elementary area. The representative elementary areas found for the sandy soil (Geric Ferralsol) and clayey soils (Rhodic Ferralsol and Eutric Nitosol) were respectively: 514.3, 514.3 and 555.4 mm² (scheme 1); 279.5, 393.3 and 457.4 mm² (scheme 2); and 457.4, 457.4 and 457.4 mm² (scheme 3). The results confirmed that the representative elementary area were influenced by the soil texture and management. Different schemes were noticed to provide different representative elementary areas for the same soil, which suggests that this procedure was efficient to detect the heterogeneity inside the soil samples.
Źródło:
International Agrophysics; 2016, 30, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi phase flow measurements with the application of ECT/ERT DECART multimodality tomograph
Pomiary przepływów wielofazowych z wykorzystaniem tomografu multimodalnego DECART
Autorzy:
Nowakowski, J.
Banasiak, R.
Wajman, R.
Sankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/408319.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
tomography
electrical capacitance tomography
gamma ray
tomografia
elektryczna tomografia pojemnościowa
promieniowanie gamma
Opis:
The multi-phase flow measurements are very important tasks in many areas of industrial processes applications. One of them is undersea exploration of oil in the petroleum industry. The submitted paper presents application of DECART tomograph designed and built in Lodz University of Technology - together with combined measurements of signals acquired from gamma ray measurement system. Use of all measuring modalities allowed for performing measurements of a flow composed of sea water, oil and gas. The paper presents theoretical principles applied to design multimodality tomograph and results of experiments performed in the University of Bergen. Measurement confirmed that multi-modality approach allows giving fast and reliable on-line results of measurements of composition of multi-phase flow. Applied algorithms allowed to speed up on-line measurements and presenting results in a form required in industrial applications. The derived conclusions can be used as guidelines for preparation of industrial applicable construction of tomograph.
Pomiary przepływów wielofazowych są szeroko wykorzystywane w wielu procesach przemysłowych. Jednym z nich jest przemysł petrochemiczny, w szczególności dziedzina eksploatacji podwodnych złóż ropy naftowej. W artykule zostało przedstawione zastosowanie tomografu DECART - zaprojektowanego i zbudowanego w Instytucie Informatyki Stosowanej Politechniki Łódzkiej. Pomiary z tomografu zostały powiązane z sygnałami uzyskanymi z systemu pomiaru promieniowania gamma. Wykorzystanie danych uzyskanych z różnych rodzajów czujników umożliwiło pomiar przepływu mieszaniny składającej się z wody morskiej, ropy naftowej i gazu. W pracy przedstawiono podstawy teoretyczne, które stanowiły punkt wyjścia do wykorzystania tomografu multimodalnego jak i wyniki eksperymentów przeprowadzonych na Uniwersytecie w Bergen. Pomiary potwierdziły, że podejście multimodalne umożliwia szybki i niezawodny pomiar udziału faz w przepływie wielofazowym. Zastosowane algorytmy pozwalają na przyspieszenie pomiarów on-line i przedstawienie wyników w formie wymaganej w zastosowaniach przemysłowych. Wnioski z badań mogą być wykorzystane jako wskazówki dla konstrukcji tomografu do praktycznych zastosowań przemysłowych.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 46-49
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies