Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Jagieła, M." wg kryterium: Wszystkie pola


Wyświetlanie 1-11 z 11
Tytuł:
Coupled static and dynamic FE analyses of a nonlinear electromechanical vibration energy harvester
Autorzy:
Kulik, M.
Jagieła, M.
Powiązania:
https://bibliotekanauki.pl/articles/97381.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
energy harvesting
coupled structural–electromagnetic analysis
finite element analysis
Opis:
The paper presents the coupled static and dynamic mechanical–electromagnetic finite element analyses of an electromechanical vibration energy harvesting converter with permanent–magnet excitation. The system consists of a small, milliwatt power range, linear–motion generator connected to a cantilever–beam spring element. The finite element equations derived for the mechanical part of the system according to the 1–D Timoshenko beam theory are coupled strongly with those describing the 2–D distribution of magnetic field in the generator and those associated with the electric circuit. The considered electromechanical coupling allows for prediction of static and dynamic response of the system subjected to action of externally applied force. The static displacement of the moving element is computed via solution of the nonlinear system of equations and is used as an initial solution in dynamic analysis. For computation of the dynamic response of the system the time–stepping procedure based on the Crank– Nicolson discretisation schema is applied. The models are positively validated against the measurements carried out on the laboratory test–stand.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 256-267
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Steady-state time-periodic finite element analysis of a brushless DC motor drive considering motion
Autorzy:
Jagieła, M.
Gwóźdź, J.
Powiązania:
https://bibliotekanauki.pl/articles/141576.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
finite elements
brushless machines
inverter drives
steady-state
mathematical modeling
Opis:
This paper aims at providing a framework for comprehensive steady-state time-domain analysis of rotating machines considering motion. The steady-state waveforms of electromagnetic and circuit quantities are computed via iterative solution of the nonlinear field-circuit-and-motion problem with constraints of time periodicity. The cases with forced speed and forced load torque are considered. A comparison of execution times with a conventional time-stepping transient model is carried out for two different machines. The numerical stability of a time-periodic model with forced speed is shown to be worse than that of traditional transient time-stepping one, although the model converges within a reasonable number of iterations. This is not the case if forced load via equation of mechanical balance is accounted for. To ensure convergence of the iterative process the physical equation of motion is replaced by the fixed-point equation. In this way the model delivers time-periodic solutions regarding not only the electromagnetic quantities but also the rotational speed.
Źródło:
Archives of Electrical Engineering; 2015, 64, 3; 471-486
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Harvesting mechanical vibrations energy using nonlinear electromagnetic minigenerators - a survey of concepts and problems
Autorzy:
Kulik, M.
Jagieła, M.
Powiązania:
https://bibliotekanauki.pl/articles/376373.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
energy harvesting
nonlinear resonance
bistability
electromagnetic induction
Opis:
The state of knowledge in the field of conversion of energy of mechanical vibrations into electrical energy using nonlinear electromagnetic generators is presented. The principle of operation of the considered converters is based on the Faraday law. The electromotive force is induced by the relative movement of the coil or permanent magnets under impact of externally applied vibrations. In order to diminish the disadvantages of conventional generators, namely the narrow frequency bandwidth, in recent years the nonlinear systems were introduced that exhibit the nonlinear resonance phenomenon. Broadening the frequency bandwidth, in which the power generated by the system is relatively high, is realized via introduction of nonlinear force into system kinematics. Designing such systems becomes a big challenge. Based on thorough survey of recent publications as well as on own expertise in the field, the work compares a few concepts of nonlinear electromechanical minigenerators in term of their functional characteristics and design problems. Sample calculations of frequency characteristics using time- and frequency-domain models are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 347-358
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coupled dynamic FE analysis of permanent-magnet mechanical vibration energy harvesting converter
Autorzy:
Kulik, M.
Jagieła, M.
Powiązania:
https://bibliotekanauki.pl/articles/377720.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
energy harvesting
coupled structural-electromagnetic analysis
finite element analysis
Opis:
The paper presents a coupled dynamic mechanical-electromagnetic finite element analysis of a vibration energy harvesting converter with permanent-magnet excitation. The system consists of a small, miliwatt power range, linear-motion permanent-magnet generator connected to a cantilever-beam spring element. The finite element equations derived for the mechanical part of the system according to the 1-D Timoshenko beam theory are coupled strongly with equations describing the 2-D distribution of magnetic field in the generator and those associated with the electric circuit. The time-stepping procedure based on the Crank-Nicolson discretisation schema is applied to the obtained system of differential-algebraic equations. The model is shown to provide satisfactory predictions of the system dynamic performance which is confirmed experimentally.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 85; 245-254
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of best rotor length in solid-rotor induction motor with axial slitting
Autorzy:
Jagiela, M.
Garbiec, T.
Powiązania:
https://bibliotekanauki.pl/articles/140492.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
prądy wirowe
silnik indukcyjny
solid-rotor
induction motor
rotor-end factor
eddy currents
Opis:
The efficiency of the solid-rotor induction machines depends on axial length of rotor (including the end-regions). Determination of the best axial length is problematic because of current density distribution in the end-regions and also because of absence of dedicated methods and models. This work proposes a method that circumvents this difficulty. It is based on the numerical determination of a dimensionless rotor-end factor using a combination of three- and two-dimensional finite element models restricted to the motor rotor. Such the end factor can be used in both analytical and numerical model of the machine in order to determine the typical performance characteristics. In this work, using this method, we determined an optimal length of the slitted solid rotor of a motor operating at 12 000 rpm, that maximizes the motor efficiency. The results of computations and measurements, carried out on the laboratory test-stand, are presented.
Źródło:
Archives of Electrical Engineering; 2012, 61, 2; 267-276
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coupling electromagnetic (FE) models to multidomain simulator to analyse eletrical drives and complex control systems
Autorzy:
Jagieła, M.
Garbiec, T.
Powiązania:
https://bibliotekanauki.pl/articles/141422.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
symulacja wspólna
napęd elektryczny
modelowanie matematyczne
metoda elementów skończonych
co-simulation
electrical drives
electromagnetic systems
mathematical modelling
finite element method
Opis:
This work presents the co-simulation approach to the analysis of control systems containing detailed models of electromagnetic and electromechanical converters. In this method of analysis the attention is paid to the whole system and not only to its electromagnetic part. The latter is described by equations resulted from the two-dimensional finite element discretisation of the Maxwell equations, and is coupled weakly with the remaining part of the system. The simulation is carried out in Matlab/Simulink environment wherein the coupling is realised through the S-function. Example results regarding simulation of the operation of the control system of an electrical machine and the operation of a power electronic converter are presented and compared with available reference data.
Źródło:
Archives of Electrical Engineering; 2010, 59, 3-4; 189-201
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of core loss for switched reluctance motors
Obliczanie strat w żelazie w przełączalnym silniku reluktancyjnym
Autorzy:
Jagieła, M.
Tomczewski, K.
Łukaniszyn, M.
Wróbel, K.
Powiązania:
https://bibliotekanauki.pl/articles/159335.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
silnik reluktancyjny przełączalny
FEM
straty w żelazie
switched reluctance motors
core losses
Opis:
In the paper the method of core loss prediction in the switched reluctance motors is presented. The classical core loss separation technique is modified for the purpose of considering an arbitrary magnetic flux density waveform. The time-stepping finite element program is elaborated for prediction of instantaneous magnetic flux density distribution in the motor core. The method of core loss calculation is backed well by the measurements carried out on the laboratory test-rig.
W pracy przedstawiono model do obliczeń strat w żelazie w przełączalnym silniku reluktancyjnym. Podstawowa trudność związana z wyznaczeniem strat w żelazie w tego rodzaju maszynach jest związana z silnie odkształconymi przebiegami lokalnych wartości indukcji magnetycznej w rdzeniu. Ponadto, w większości punktów obwodu magnetycznego przebiegi te zawierają niezerową składową stałą. W takim przypadku nie można użyć bezpośrednio podejścia, stosowanego w maszynach prądu przemiennego, polegającego na podziale strat i wykorzystaniu typowych krzywych stratności jednostkowej materiału magnetycznego podawanych przez producentów. W celu rozwiązania tego problemu w niniejszej pracy zastosowano metodę polegającą na przekształceniu równania opisującego stratność jednostkową materiału ferromagnetycznego, zgodnie z hipotezą przedstawioną w pracy [7]. W wyniku analitycznego przekształcenia równania (2), otrzymano równanie (3), które jest określone w dziedzinie czasu, a nie w dziedzinie częstotliwości. Równanie to zawiera tyle samo stałych, co równanie oryginalne. Stałe te można względnie łatwo wyznaczyć metodą optymalizacji nieliniowej. Wyniki obliczeń tych stałych zawiera tabela 1. W celu wyznaczenia przebiegów lokalnej wartości indukcji w obwodzie magnetycznym, opracowano model polowo-obwodowy silnika o dwóch pasmach fazowych oraz mocy znamionowej 100 W, w oparciu o metodę elementów skończonych. Wykorzystując obliczone przebiegi indukcji magnetycznej w całym obwodzie magnetycznym oraz równanie (3) opisujące stratność jednostkową, wyznaczono całkowite straty w rdzeniu w funkcji prędkości obrotowej. Przeprowadzono weryfikację eksperymentalną opracowanego modelu w oparciu o skonstruowane stanowisko pomiarowe (rys. 2b) uzyskując dużą zgodność wyników obliczeń z danymi doświadczalnymi (rys.4). Pozytywne wyniki weryfikacji pozwalają uznać przedstawione podejście za wystarczająco dokładną oraz ogólną metodę obliczania strat w żelazie w silnikach reluktancyjnych zasilanych jednopulsowo.
Źródło:
Prace Instytutu Elektrotechniki; 2009, 240; 141-150
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of Zinc Ions from Aqueous Solutions with the Use of Lignin and Biomass. Part II
Autorzy:
Miros-Kudra, P.
Sobczak, P.
Gzyra-Jagieła, K.
Ciepliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/24200965.pdf
Data publikacji:
2023
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
lignin
sorption
biomass
zinc ions
water treatment
Opis:
In response to the trend toward sustainable management of by-products from the pulp and paper industry as well as plant waste, practical and economical methods are being developed to use them in a way that does not pose a threat to the environment. The main aim of the research was to study the possibility of using lignin and plant biomass as biosorbents for the removal of zinc ions from aqueous solutions. The secondary aim was to build an optimal multilayer system made of biosorbents selected during the research in order to obtain the highest sorption efficiency and to determine the best conditions of the sorption process. The effectiveness of zinc ion sorption was assessed using an appropriate combination of sorbents such as lignin, oat bran, rice husk, chitosan, pectin, sodium alginate, pine bark, coconut fiber and activated carbon, selected on the basis of literature data and the preliminary results of tests carried out using FTIR and AAS. The main component of the sorption system was lignin separated from black liquor. Results indicate that the best Zn sorption system was based on coconut fiber, lignin, and pine bark, for which the maximum sorption efficiency was 95%. The research also showed that the increase in the process temperature, the mass of biosorbents used and the alkaline pH are the factors that increase the efficiency of the sorption. It can be concluded that lignin and plant biomass can be used as ecological sorbents of zinc ions from water solutions. They are safe for the environment, produced from renewable sources, and are by-products or waste materials, which is part of the sustainable development and circular economy currently promoted in the EU.
Źródło:
Fibres & Textiles in Eastern Europe; 2023, 31, 2; 11--25
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chemical Purity of PLA Fibres for Medical Devices
Badania czystości chemicznej biodegradowalnych włókien z PLA przeznaczonych na wyroby medyczne
Autorzy:
Jóźwicka, J
Gzyra-Jagieła, K
Gutowska, A.
Twarowska-Schmidt, K.
Ciepliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/232040.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
biomedical polymers
PLA fibres
chemical purity
medical devices
sanitary articles
spin finish
physical-chemical analysis
chemical contamination
biomedyczne polimery
włókna z PLA
czystość chemiczna
urządzenia medyczne
artykuły higieniczne
analiza fizykochemiczna
zanieczyszczenia chemiczne
Opis:
The chemical purity of biodegradable poly(D,L-lactide) (PLA) fibres finished with various finishing agents was examined. Chemical purity parameters of aqueous extracts of the fibres were assessed, including turbidity, the content of sulphate and chloride ions, the content of water-dissolvable substances, the content of foaming agents, the content of heavy metal ions and pH. The content of organic solvent-leachable substances was also estimated according to the PN-EN ISO 10993-12:2009 standard. Tests under equal conditions were performed for PLA fibres spun without any spinfinish, PLA fibres with the spinfinish removed by extraction with organic solvents, and the raw material, PLA 6201D granulate. The certified fibre-grade polymer PLLA produced by Boehringer Ingelheim Pharma GmbH & Co KG (Germany) under the trade name Resomer L 207S served as the reference material and was analysed in the same way. In terms of chemical purity, PLA fibres finished with Estesol PF-790, pharmaceutical glycerol (glycerine), and PLA fibres after removal of the spinfinish were found to be suitable to use in hygiene and medical devices.
Przeprowadzono badania czystości chemicznej biodegradowalnych włókien wytworzonych z poli(D,L-laktydu mlekowego) – PLA z naniesionymi w procesie przędzenia różnymi rodzajami preparacji. Przygotowane wyciągi wodne z włókien wytworzonych z PLA poddano ocenie w zakresie podstawowych parametrów czystości chemicznej: stopnia zmętnienia, zawartości jonów siarczanowych i chlorkowych, zawartości substancji rozpuszczalnych w wodzie, zawartości środków pianotwórczych, zawartości jonów metali ciężkich oraz odczyn pH wyciągów. Zawartość substancji wymywanych z włókien PLA rozpuszczalnikami organicznymi oznaczono wg PN-EN ISO 10993-12:2009. W tych samych warunkach zbadano czystość chemiczną włókien z PLA otrzymanych w procesie przędzenia bez naniesienia preparacji, włókien z PLA po usunięciu preparacji metodą ekstrakcji rozpuszczalnikami organicznymi oraz surowca do otrzymania włókien – granulatu PLA 6201D. Jako materiał odniesienia przyjęto certyfikowany polimer PLLA przeznaczony na wyroby medyczne, który poddano badaniom czystości chemicznej w tych samych warunkach. Stwierdzono, że pod kątem czystości chemicznej włókna z PLA z naniesionymi preparacjami: Estesol PF-790 i gliceryną farmaceutyczną, oraz włókna z PLA po usunięciu tych preparacji mogą znaleźć zastosowanie jako półfabrykaty do otrzymywania płaskich wyrobów higienicznych i/lub medycznych.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 135-141
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accelerated Ageing of Implantable, Ultra-Light, Knitted Medical Devices Modified by Low-Temperature Plasma Treatment - Part 2. Effect on Chemical Purity
Badania procesu przyspieszonego starzenia implantowalnych, ultra-lekkich dzianych wyrobów medycznych zmodyfikowanych niskotemperaturową plazmą - Część 2. Wpływ symulowanych warunków przyspieszonego starzenia na czystość chemiczną
Autorzy:
Jóźwicka, J.
Gzyra-Jagieła, K.
Gutowska, A.
Struszczyk, M.
Kostanek, K.
Cichecka, M.
Wilbik-Hałgas, B.
Kowalski, K.
Kopias, K.
Ciechańska, D.
Krucińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/232105.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
ultra-light knitted implants
accelerated ageing
chemical purity
leachable substances
ultra lekkie dziane wyroby medyczne
przyśpieszone starzenie się wyrobów medycznych
czystość chemiczna
Opis:
The impact of simulated storage conditions (accelerated ageing) for the chemical purity of innovative ultra-light textile implants (knitted) designed for use in urogynaecology and general surgery (procedures in the treatment of female incontinence, in hernia treatment and vagina plastic surgery) was estimated. The chemical purity of the knitted implants designed: untreated and with low-temperature plasma surface treatment in the presence of the fluoroorganic compounds was estimated. The acceptability of the risk related to the impact of storage conditions on the chemical purity of the implant products was simulated. The examination was based on Standard PN-EN ISO 10993-18:2008: “Biological evaluation of medical devices - Part 18: Chemical characterisation of materials” and was assessed in accordance with Polish and European standards.
W niniejszej pracy dotyczącej badań w zakresie oceny czystości chemicznej zaprojektowanych implantowalnych wyrobów medycznych oszacowano profil substancji wymywalnych w warunkach symulowanego użycia (specyficzne warunki przetwarzania i przechowywania, natura i czas kontaktu wyrobu) w oparciu o wytyczne norm europejskich zharmonizowanych z Dyrektywami europejskimi odnoszącymi się do wyrobów medycznych. Ustalono wpływ symulowanych warunków przechowywania (przyspieszonego starzenia) na czystość chemiczną innowacyjnych ultra-lekkich implantów włókienniczych (dzianin) z przeznaczeniem na implantowalne wyroby medyczne do potencjalnego zastosowania w urologinekologii i chirurgii ogólnej (procedury zaopatrywania nietrzymania moczu u kobiet, procedury zaopatrywania przepuklin i plastyki pochwy u kobiet). Wybrane prototypy wyrobów medycznych poddano procesowi przyspieszonego starzenia zgodnie z programem badań opartym o wytyczne normy ASTM 1980F:2002. Ocenie czystości chemicznej poddano zaprojektowane implanty dziane o powierzchni modyfikowanej plazmą niskotemperaturową w obecności związku fluoroorganicznego oraz implanty niemodyfikowane plazmą. Dokonano oceny akceptowalności ryzyka w zakresie wpływu symulowanych warunków przechowywania na czystość chemiczną zaprojektowanych implantowalnych wyrobów medycznych. Badania przeprowadzono w oparciu o procedury badawcze opracowane zgodnie z normatywami polskimi i europejskimi.
Źródło:
Fibres & Textiles in Eastern Europe; 2014, 3 (105); 133-139
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspects of Chemical Characterisation of Leachables Profile from Ultra-Light Knitting Textiles for Uses as Medical Implants in Urogynaecology and General Surgery
Aspekty charakterystyki chemicznej substancji wymywalnych z ultralekkich dzianin o potencjalnym zastosowaniu jako implantowalne wyroby medyczne stosowane w urologinekologii i chirurgii ogólnej
Autorzy:
Jóźwicka, J.
Gzyra-Jagieła, K
Struszczyk, M. H.
Gutowska, A.
Ciechańska, D.
Krucińska, I
Powiązania:
https://bibliotekanauki.pl/articles/232383.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
ultra-light textile implants for urogynaecology
evaluation of chemical leachable profile
physical-chemical parameters
substancje wymywalne z ultralekkich dzianin
wyroby medyczne
implanty w urologii
Opis:
Ultra-light textiles (knitwear) designed as implantable medical devices for potential uses in urogynaecology (treatment procedures in women incontinence and vagina reconstructions) and general surgery (hernia treatments) are a response to the increasing demand for advanced medical devices in medicine. Chemical profile characterisation of leachable substances is an important factor in the use of the materials influencing their biocompatibility. The implant is made of undesired chemical substances in the main raw-material, and penetration into the tissue may cause local and/or systemic inflammation in the patient’s body. The characterisation and analysis of such substances is therefore essential to secure the safe use of implants. Most important is the characterisation of the matter that is extractable from the designed medical devices. To serve these purpose, ultra-light textile implants designed for potential use in urogynaecology and general surgery were examined concerning the chemical analysis of the undesired substance contained in the main material which constitutes the base of the implant. It was a goal of the work to set optimal parameters for the examination of chemical characterisation of the leachable implant’s material, bearing in mind their safe clinical use. Analysis of the chemical leachable profile was made in accordance with directives of standard PN-EN ISO 10993-18:2008 and some Polish and European testing procedures.
Artykuł przedstawia innowacyjne ultra-lekkie implanty włókiennicze w postaci dzianiny z przeznaczeniem na implanty do potencjalnego zastosowania w urologinekologii i chirurgii ogólnej (procedury zaopatrywania przepuklin nietrzymania moczu u kobiet i plastyki pochwy). Badano własności?? charakterystyki substancji wymywalnych z projektowanych implantów. Ultralekkie dzianiny poddano ocenie czystości chemicznej pod kątem wpływu ewentualnych substancji wymywalnych na ich bezpieczeństwo kliniczne. Wyznaczono optymalne parametry badań czystości chemicznej implantowalnych wyrobów medycznych. Oceny czystości chemicznej wyselekcjonowanych dzianin dokonano w oparciu o metody badawcze opracowane na podstawie wytycznych normy PN-EN ISO 10993-18:2008: „Biologiczna ocena wyrobów medycznych – Część 18: Charakterystyka chemiczna materiałów” (ISO 10993-18:2009) oraz opracowanych procedur badawczych na bazie normatywów polskich i europejskich.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 128-134
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies