Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ventilation management" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Ventilation control of the new safe confinement of the Chornobylnuclear power plant based on neuro-fuzzy networks
Kontrola wentylacji nowej bezpiecznej powłoki czarnobylskiej elektrowni jądrowej oparta na rozmytych sieciach neuronowych
Autorzy:
Loboda, Petro
Starovit, Ivan S.
Shushura, Oleksii M
Havrylko, Yevhen V.
Saveliev, Maxim V.
Sachaniuk-Kavets’ka, Natalia
Neprytskyi, Oleksandr
Oralbekova, Dina
Mussayeva, Dinara
Powiązania:
https://bibliotekanauki.pl/articles/28875033.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
New Safe Confinement
ventilation management
neuro-fuzzy network
information technology
fuzzy logic
digital twin
Nowa Bezpieczna Powłoka
zarządzanie wentylacją
rozmyta sieć neuronowa
technologia informacyjna
logika rozmyta
cyfrowy bliźniak
Opis:
The accident at the Chornobyl Nuclear Power Plant (ChNPP) in Ukraine in 1986 became one of the largest technological disasters in human history. During the accident cleanup, a special protective structure called the Shelter Object was built to isolate the destroyed reactor from the environment. However, the planned operational lifespan of the Shelter Object was only 30 years. Therefore, with the assistance of the international community, a new protective structure called the New Safe Confinement (NSC) was constructed and put into operation in 2019. The NSC is a large and complex system that relies on a significant number of various tools and subsystems to function. Due to temperature fluctuations and the influence of wind, hydraulic processes occur within the NSC, which can lead to the release of radioactive aerosols into the environment. The personnel of the NSC prevents these leaks, including through ventilation management. Considering the long planned operational term of the NSC, the development and improvement of information technologies for its process automation is a relevant task. The purpose of this paper is to develop a method for managing the ventilation system of the NSC based on neuro-fuzzy networks. An investigation of the current state of ventilation control in the NSC has been conducted, and automation tools for the process have been proposed. Using an adaptive neuro-fuzzy inference system (ANFIS) and statistical data on the NSC's operation, neuro-fuzzy models have been formed, which allows to calculate the expenses of the ventilation system using the Takagi-Sugeno method. The verification of the proposed approaches on a test data sample demonstrated sufficiently high accuracy of the calculations, confirming the potential practical utility in decision-making regarding NSC’s ventilation management. The results of this paper can be useful in the development of digital twins of the NSC for process management and personnel training.
Awaria w Czarnobylskiej Elektrowni Jądrowej (ChNPP), która miała miejsce w Ukrainie w 1986 roku, stała się jedną z największych katastrof technologicznych w historii ludzkości. Podczas likwidacji awarii zbudowano specjalną strukturę ochronną – Obiekt "Ukrycie", mającą na celu izolację zniszczonego reaktora od otoczenia. Jednak planowany okres eksploatacji sarkofagu "Ukrycie" wynosił tylko 30 lat, dlatego przy wsparciu społeczności międzynarodowej zbudowano nową strukturę ochronną – "Nowa Bezpieczna Powłoka" (NSC), która została oddana do użytku w 2019 roku. NSC jest dużym i skomplikowanym systemem, którego funkcjonowanie zapewnia znaczna liczba różnych narzędzi i podsystemów. Ze względu na zmienne temperatury i wpływ wiatru, w NSC zachodzą procesy hydrauliczne, które mogą prowadzić do uwolnienia promieniotwórczych aerozoli do otoczenia. Personel NSC zapobiega tym wyciekom, między innymi poprzez zarządzanie wentylacją. W związku z długim planowanym okresem eksploatacji NSC, istotnym zadaniem jest rozwój i doskonalenie technologii informatycznych dla automatyzacji procesów. Celem pracy jest opracowanie metody zarządzania systemem wentylacji NSC opartej na rozmytych sieciach neuronowych. Przeprowadzono badania istniejącego stanu rozwiązywania problemów zarządzania wentylacją NSC oraz wybrano narzędzia do automatyzacji procesu. Za pomocą adaptacyjnego systemu wnioskowania neuro-rozmytego (ANFIS) i danych statystycznych dotyczących funkcjonowania NSC, stworzono modele neuro-rozmyte, które pozwalają na kalkulację kosztów systemu wentylacyjnego metodą Takagi-Sugeno. Weryfikacja zaproponowanych podejść na próbce kontrolnej danych wykazała wystarczająco wysoką dokładność obliczeń, co potwierdza możliwość ich praktycznego zastosowania w procesie podejmowania decyzji dotyczących zarządzania wentylacją NSC. Wyniki pracy mogą być również przydatne przy tworzeniu cyfrowe bliźniaków NSC w celu zarządzania procesami i szkolenia personelu.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2023, 13, 4; 114--118
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of Geodata in the Process of the Ventilation of the City of Krakow
Autorzy:
Budkowski, Szczepan
Powiązania:
https://bibliotekanauki.pl/articles/27314287.pdf
Data publikacji:
2023
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Green New Deal
geodata
spatial management
city ventilation
environmental protection
Opis:
The purpose of this publication is to analyze air pollution on the example of the city of Krakow, as well as to consider the possibility of using geodata for environmental protection. In addition to case study analysis as the leading research method, the article also uses the observation, analysis, and statistical methods. The article presents the concept of using GIS spatial analyzes and spatial planning as an element of the Green New Deal in the process of ventilating the city of Krakow. When developing a project related to city ventilation, it is extremely important to have the most accurate data on the strength, direction of the wind, type of pollution, and the number of emitters. Spatial analyzes are also able to indicate the main ventilation corridors of the city. These include, above all, areas located on the Vistula River, but also the widest city streets. Such results make it possible to more consciously manage space.
Źródło:
Geomatics and Environmental Engineering; 2023, 17, 4; 53--76
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
How to protect staircases in case of fire in mid-rise buildings. Real scale fire tests
Jak zabezpieczyć klatki schodowe w budynkach średniowysokich na wypadek pożaru. Wyniki badań rzeczywistych
Autorzy:
Kubicki, Grzegorz
Tekielak-Skałka, Izabela
Cisek, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2060826.pdf
Data publikacji:
2019
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
smoke management
fire tests
fire ventilation
staircase
kontrola
dym
próba ogniowa
wentylacja pożarowa
schody
Opis:
Purpose: The aim of the analysis was to investigate how smoke would spread in the building in the case of fire, and how to protect staircases without a pressure differential system (PDS). It was assumed that a ventilation system should: – prevent the staircase against complete smokiness. The part of the staircase located below the level covered by the fire should be smoke-free to the extent allowing the evacuation of people from the fire compartments; – remove smoke from the staircase as fast as possible to prevent a significant increase in the level of pressure in the staircase. Project and methods: Research was conducted in a full-scale 9-storey building. Three real fires were simulated. Typical apartment furnishings were used in the fires. A smoke ventilation system was installed in the staircase with variable make-up air supply. Tests were carried out for the following configurations of smoke ventilation systems: – natural smoke exhaust with natural/gravitational make-up air; – natural smoke exhaust with a mechanical (fixed volume of 14000 m3/h) make-up air inlet; – natural smoke exhaust with a variable mechanical make-up air inlet. The position of the door between the staircase and the apartment was used as an additional variable. The measurements included temperature, light transmittance in the staircase, pressure difference between the staircase and the external environment, and the flow of the air and smoke through the smoke damper. Results: The results of the research show that the system of gravitational smoke ventilation is susceptible to ambient conditions such as temperature. In some tests, it was observed that smoke could descend below the storey covered by the fire. The conducted research helped determine the best way to reduce the amount of smoke in the staircase. The use of mechanical air supply in the smoke ventilation system facilitated fast smoke removal from the staircase, and the proper air and smoke flow direction (from the test room to smoke exhaust devices). The use of mechanical make-up air supply in the smoke ventilation system prevented the smoke from descending below the storey covered by the fire, so that the staircase on the floor covered by the fire could remain free from smoke in the lower part, providing a way of escape from the level covered by the fire. Conclusions: The conducted tests have revealed that the best solution to protect staircases without PDSs is to use a smoke ventilation system comprising a smoke vent mounted at the top and mechanically adjusted make-up air supply on the ground level.
Cel: Celem badań była analiza rozprzestrzenia się dymu pod kątem oceny skuteczności różnych systemów oddymiania klatki schodowej. Założono, że działanie takiej instalacji powinno: – zapobiegać zadymieniu części klatki schodowej, znajdującej się poniżej kondygnacji, na której zlokalizowany jest pożar, – po odcięciu napływu dymu na klatkę schodową, oczyszczać tę przestrzeń z dymu w krótkim czasie – realizacja oddymiania klatki schodowej nie może prowadzić do znacznego wzrostu nadciśnienia w klatce schodowej. Projekt i metody: Badania przeprowadzone zostały w 9-kondygnacyjnym budynku rzeczywistym. W ramach badań wykonano m.in. trzy prawdziwe pożary w pełnej skali. Każdy z pożarów inicjowany był w zaadaptowanym pomieszczeniu wyposażonym każdorazowo w identyczny zestaw mebli i elementów wyposażenia. Na klatce schodowej zainstalowano system oddymiania ze zmiennym dopływem powietrza uzupełniającego. Testy przeprowadzono dla następujących konfiguracji systemów oddymiania: – naturalny układ oddymiania z naturalnym / grawitacyjnym powietrzem uzupełniającym; – naturalny układ oddymiania z mechanicznym (stała wartość objętości 14000 m3/h) wlotem powietrza uzupełniającego; – naturalny układ oddymiania ze zmiennym mechanicznym wlotem powietrza uzupełniającego. Dodatkową zmienną było położenie drzwi między klatką schodową a mieszkaniem. Podczas testów rejestrowano: temperaturę (72 punkty pomiarowe), transmitancję światła (poziom zadymienia), różnicę ciśnień między klatką schodową a otoczeniem zewnętrznym oraz przepływ powietrza i dymu przez klapę dymu. Dodatkowo stale monitorowane były podstawowe parametry atmosferyczne (siła i kierunek wiatru, temperatura i wilgotność powietrza). Wyniki: Wyniki badań wykazały wysoką wrażliwość grawitacyjnego systemu oddymiania na warunki otoczenia (zaobserwowano, że w niekorzystnych warunkach dym może opaść poniżej kondygnacji objętej pożarem). Najskuteczniejszą i najbardziej odporną na zakłócenia metodą oddymiania był mechaniczny dopływ powietrza. Pozwolił on na szybkie usunięcie dymu ze schodów oraz prawidłowe, stałe i właściwe ukierunkowanie przepływu. System ten nie dopuszczał do opadania dymu poniżej kondygnacji objętej pożarem, zaś regulacja wydajności w zależności od przepływu na klapie zabezpieczała przestrzeń klatki schodowej przed wzrostem nadciśnienia. Wnioski: Najlepszą metodą oddymiania klatki schodowej jest zastosowanie klapy dymowej oraz mechanicznie regulowanego dopływu powietrza uzupełniającego na poziomie wyjścia z budynku.
Źródło:
Safety and Fire Technology; 2019, 54, 2; 6--20
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Retrofitting existing office building for efficient energy management and performance
Modernizacja istniejącego budynku biurowego dla efektywnego zarządzania energią
Autorzy:
Oluseyi, Peter Olabisi
Ezike, Ifunanya Lilian
Powiązania:
https://bibliotekanauki.pl/articles/2055086.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
Building Information Management
BIM
Energy Retrofitting Interventions
Heating Ventilation and Air-Conditioning
HVAC
Green Building Extensible Mark-up Language
modelowanie BIM
modernizacja energetyczna
ogrzewanie
wentylacja
klimatyzacja
oprogramowanie Green Building Extensible Mark-up Language
Opis:
This study focuses on designing an efficient energy utilization protocol for the University of Lagos Senate office building, to ensure the reduction of energy consumption, reduce the cost of power and also ensure energy efficiency. Pre-retrofitting, the energy consumption cost for the UNILAG senate office building was calculated to be ₦20, 236, 962 i.e. 776.78 EUI (kWh/m²/y) using the appliance approach. The impact of various retrofitting methods was also simulated and measured utilizing BIM tools such as Autodesk Maya, Autodesk Revit and Autodesk Insight. This resulted in an estimated reduction in energy consumption cost to between ₦19,304,038.05 and 18,549,199.3 post retrofitting, this translates to about 712 EUI (kWh/m²/y). Results show that a 4.61-8.34% reduction in energy usage for the senate house can be achieved using the methods proposed in this research.
Praca koncentruje się na opracowaniu procedury efektywnego wykorzystania energii w budynku biurowym Senatu Uniwersytetu w Lagos w celu zapewnienia redukcji zużycia energii, redukcji jej kosztów i zapewnienia efektywności energetycznej. Przed modernizacją koszt zużycia energii w budynku Senatu został obliczony jako ₦20, 236, 962, tj. 776.78 EUI (kWh/m²/y) w oparciu o zamontowane urządzenia. Symulowano wpływ różnych technik modernizacyjnych i prowadzono obliczenia korzystając z narzędzi opartych o technologię BIM, tj. Autodesk Maya, Autodesk Revit i Autodesk Insight. To doprowadziło do przewidywanej redukcji kosztów energii pomiędzy ₦19,304,038.05 i 18,549,199.3 po modernizacji, co odpowiada ok. 712 EUI (kWh/m²/y). Wyniki wskazują, że możliwa jest redukcja zużycia energii dla budynku Senatu na poziomie 4.61-8.34% w oparciu o metody przedstawione w pracy.
Źródło:
Structure and Environment; 2021, 13, 1; 16--28
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies