Tytuł:
Drgania spiralne turbozespołu generowane przez aparat szczotkowy
Turbo-set spiral vibrations generated by a brush gear system
Autorzy:
Nowicki, R.
Powiązania:
https://bibliotekanauki.pl/articles/1197461.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
stan techniczny
drgania spiralne
turbina-generator
aparat szczotkowy
technical condition
spiral vibrations
turbine-generator set
brush-gear system
Opis:
This paper describes an example of inference about rotating turbo-generator set technical condition for situations when spiral vibrations happen. Analysis of these vibrations allows quickly formulated diagnosis of root cases of a problem, which allows you to make an informed decision about the need for maintenance. An example of a problem relating to 2-pole generator is discussed.
Omówiono przykład wnioskowania o stanie technicznym turbozespołu w przypadku wystąpienia drgań spiralnych. Analizy drgań pozwalają na szybkie postawienie wysoce wiarygodnej diagnozy, co umożliwia podjęcie świadomej decyzji na okoliczność potrzeby remontu. Pokazano przykład drgań spiralnych dla generatora 2-biegunowego.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 3, 119; 205-212
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The concept of a new car shock absorber with energy recuperation
Koncepcja nowego amortyzatora samochodowego z odzyskiem energii
Autorzy:
Siczek, K.
Kuchar, M.
Powiązania:
https://bibliotekanauki.pl/articles/1364800.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
amortyzator
generator energii elektrycznej
odzysk energii
turbina
electric power generator
energy recuperation
shock absorber
turbine
Opis:
The concept of a shock absorber able to recuperate from energy chassis vibrations has been presented in the article. Energy released from such vibrations has thus far simply dissipated. The shock absorber is composed of the cylinder, the turbine and the generator. Its dimensions are close to those of hydraulic shock absorber, so the new shock absorber can be used in a typical automobile. The changes for values of dynamic parameters during operation of the new shock absorber components have been estimated using published data. The analysis of dynamics for the shock absorber operating in road conditions has been based on this data. Such analysis has allowed checking the operation correctness of the new design from both the shock absorber and the electric generator point of view. The amount potential of electric power available for recovery in the shock absorber has been estimated for typical road conditions. Such electric power can be used as a comparative parameter in the cost-effectiveness analysis for use of new shock absorbers in automobiles. The model performed of the turbine has been elaborated. Analysis of fluid flows in the model has been carried out and results of it have been shown.
W artykule została przedstawiona koncepcja nowego amortyzatora samochodowego z odzyskiem energii drgań podwozia. Taka energia rozproszona dotychczas na ciepło może być zamieniona na użyteczną energię elektryczną. Nowy amortyzator składa się z cylindra, zespołu turbiny i zespołu generatora energii elektrycznej. Jego wymiary są zbliżone do tych charakteryzujących amortyzator hydrauliczny, toteż nowy amortyzator z odzyskiem energii może być używany w typowym podwoziu samochodu. Zmiany wartości parametrów dynamicznych zachodzące podczas eksploatacji nowego amortyzatora i jego elementów składowych, zostały oszacowane na podstawie danych literaturowych. Na podstawie tych danych oceniono dynamikę nowego amortyzatora, pracującego w warunkach drogowych. Taka analiza pozwoliła na sprawdzenie poprawności działania nowego projektu zarówno z punktu widzenia amortyzatora jak i generatora energii elektrycznej. Uzyskane wartości współczynnika tłumienia, głównie podczas pracy generatora energii elektrycznej w nowym amortyzatorze, pozwoliły na używanie takiego amortyzatora w samochodzie. Ilość energii możliwej do odzyskania w nowym amortyzatorze została oszacowana dla typowych warunków drogowych. Taka energia elektryczna może być wykorzystana jako parametr do porównawczej analizy opłacalności wykorzystania nowego amortyzatora w samochodzie. Został opracowany model zespołu turbiny i przeprowadzono analizę przepływów płynu w modelu, która umożliwiła ocenę obciążenia wirnika turbiny i współczynnika tłumienia amortyzatora.
Źródło:
Archiwum Motoryzacji; 2012, 2; 49-61
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wieloobszarowa regulacja systemu turbogeneratora elektrowni jądrowej
Multiregional control of nuclear power plant turbogenerator system
Autorzy:
Sokólski, P.
Kulkowski, K.
Kobylarz, A.
Duzinkiewicz, K.
Rutkowski, T. A.
Grochowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/952780.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
turbogenerator
turbina parowa
generator synchroniczny
regulacja rozmyta
steam turbine
synchronous generator
nuclear power plant
fuzzy control
Opis:
W artykule przedstawiono propozycję zaawansowanej struktury sterowania układem turbogeneratora w szerokim zakresie zmian zapotrzebowania na moc czynną. Dla potrzeb syntezy tej struktury wykorzystano nieliniowe, dynamiczne modele turbiny parowej i generatora synchronicznego współpracującego z systemem elektroenergetycznym. Zaproponowane algorytmy sterowania oparte są odpowiednio o wieloobszarowe regulatory rozmyte, z lokalnymi regulatorami PI. Miękkie przełączanie pomiędzy nimi jest realizowane za pomocą rozmytego wnioskowania Takagi-Sugeno-Kanga. Zaprezentowane wyniki badań symulacyjnych pokazują poprawę jakości realizacji zadania nadążania za zmienną trajektorią zadanej mocy czynnej, przy wykorzystaniu zaproponowanych rozwiązań, w porównaniu do klasycznych, pojedynczych regulatorów PI w pętlach sterowania turbiny i generatora synchronicznego.
In the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multiregional fuzzy control systems with local linear controllers, including PID controllers, in particular control loops of turbine and generator. Soft switching between the local controllers is performed by Takagi-Sugeno-Kang fuzzy logic mechanism. Parameters of the local controllers were optimally tuned for a priori chosen operating points within the range 50-100% of nominal active power generated by the synchronous generator. Simulation results show that proposed advanced control structure is superior to widely used classic control structure (local controllers tuned for nominal operating points). During simulations the data of the real devices were used, respectively for the 4 CK 465 steam turbine and synchronous generator GTHW-600, which were planned to be used in the first Polish nuclear power plant in Żarnowiec.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 129-132
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunek: pasywna oczyszczalnia Płaszów
Autorzy:
Biedrzycka, A.
Powiązania:
https://bibliotekanauki.pl/articles/364337.pdf
Data publikacji:
2016
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
Kraków
Oczyszczalnia Płaszów
wodociągi
kanalizacja
turbina
generator termoelektryczny
Cracow
refinery Plaszow
water supply
sewers
turbine
thermoelectric generator
Opis:
Oczyszczalnie zwiększają zużycie energii z powodu konieczności dopasowania się do coraz surowszych wymogów jakościowych dla oczyszczonych ścieków. W tej sytuacji wysiłki inżynierów skupiają się na stworzeniu systemu zdolnego wydatnie zredukować zużycie energii konwencjonalnej, a nawet zbliżyć oczyszczalnię do poziomu obiektu pasywnego. Taki projekt realizują Wodociągi Krakowskie w oczyszczalni Płaszów we współpracy z naukowcami z Akademii Górniczo-Hutniczej.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2016, 6; 14-17
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced Control Structures of Turbo Generator System of Nuclear Power Plant
Zaawansowane struktury sterowania systemem turbogeneratora elektrowni jądrowej
Autorzy:
Sokólski, P.
Kulkowski, K.
Kobylarz, A.
Duzinkiewicz, K.
Rutkowski, T. A.
Grochowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/397572.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
turbogenerator
steam turbine
synchronous generator
nuclear power plant
fuzzy control
turbina parowa
generator synchroniczny
elektrownia jądrowa
sterowanie rozmyte
Opis:
In the paper a  synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. The considered control structure consists of multi-regional fuzzy control systems with local linear controllers, including PID controllers, in particular control loops of turbine and generator. Soft switching between the local controllers is performed by the Takagi-Sugeno-Kang fuzzy logic mechanism. Parameters of the local controllers were optimally tuned for a priori chosen operating points within the range of 50–100% of nominal active power generated by the synchronous generator. Simulation results show that proposed advanced control structure is superior to widely used classic control structure (local controllers tuned for nominal operating points). During simulations the data of the real devices was used, respectively for the 4 CK 465 steam turbine and synchronous generator GTHW-600, which were planned to be used in the first Polish nuclear power plant in Żarnowiec.
W artykule przedstawiono syntezę zaawansowanych struktur sterowania turbiną i generatorem synchronicznym dla elektrowni jądrowej pracującej w zmiennych warunkach operacyjnych (zapotrzebowanie na moc czynną). Oparta jest ona na nieliniowych modelach turbiny parowej oraz generatora synchronicznego współpracującego z systemem elektroenergetycznym. Rozważana struktura sterowania składa się z wieloobszarowych systemów sterowania rozmytego z lokalnymi liniowymi regulatorami, w tym regulatorami PID, w poszczególnych pętlach sterowania turbiny i generatora. Miękkie przełączanie pomiędzy lokalnymi regulatorami jest realizowane przez mechanizm logiki rozmytej Takagi-Sugeno-Kanga. Parametry regulatorów lokalnych były dobierane optymalnie dla wybranych a priori punktów pracy w zakresie 50–100% nominalnej mocy czynnej wytwarzanej przez generator synchroniczny. Wyniki symulacji pokazują, że proponowana struktura sterowania zaawansowanego przewyższa powszechnie stosowaną klasyczną strukturę sterowania (pojedyncze regulatory lokalne strojone dla nominalnego punktu pracy). W trakcie symulacji wykorzystano dane rzeczywistych urządzeń, odpowiednio: turbiny parowej 4 CK 465 i generatora synchronicznego GTHW-600, które planowano zastosować w pierwszej polskiej elektrowni jądrowej w Żarnowcu.
Źródło:
Acta Energetica; 2015, 3; 83-96
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zarys rozwoju elektrowni wiatrowych
Outline of the development of wind power plant
Autorzy:
Szymczak, P.
Prajzendanc, P.
Łosiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1201664.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
energetyka wiatrowa
etapy rozwoju
generator
pionierzy
turbina
wind energy
stages of development
pioneers
turbine
Opis:
The paper discusses the outline of the historical development of wind power on land and sea and provides brief biographical data of selected artists and pioneers in the field. Periodization proposed development of electric generators and wind turbines. Specific steps briefly characterized. In the following paper discusses the current state of wind energy, both worldwide and in Poland and presents the projected scenarios of its development in the European Union and Poland. A summary of the work finalized.
W pracy omówiono zarys historyczny rozwoju elektrowni wiatrowych na lądzie i morzu oraz zamieszczono krótkie dane biograficzne wybranych pionierów i twórców w tej dziedzinie. Zaproponowano periodyzację rozwoju generatorów elektrycznych i elektrowni wiatrowych. Poszczególne etapy pokrótce scharakteryzowano. W dalszej części pracy omówiono obecny stan energetyki wiatrowej zarówno na świecie jak i w Polsce oraz przedstawiono prognozowane scenariusze jej rozwoju w Unii Europejskiej i Polsce.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 4, 112; 201-207
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of structure of heat recovery steam generator and of gas turbogenerator power repowering a 370 MW unit on the power plant operating in cogeneration cycle
Wpływ struktury kotła odzyskowego i mocy turbozespołu gazowego nadbudowujących blok 370 MW na jego pracę - praca skojarzona bloku
Autorzy:
Bartnik, R.
Buryn, Z.
Duczkowska-Kądziel, A.
Powiązania:
https://bibliotekanauki.pl/articles/173157.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł odzyskowy
turbozespół gazowy
turbina parowa
heat recovery steam generator
gas turbogenerator
steam turbine
Opis:
W artykule zaprezentowano rezultaty termodynamicznych obliczeń doboru struktury kotła odzyskowego i mocy turbozespołu gazowego do bloku o mocy 370 MW zmodernizowanego do dwupaliwowego układu gazowo-parowego. Obliczenia przeprowadzono dla pracy skojarzonej bloku.
The paper presents results of technical calculations involving the selection of a structure of heat recovery steam generator and of gas turbogenerator power applied for adaptation of a coal-fired power unit with the rated capacity of 370 MW to dual-fuel steam-gas system. Calculations were conducted for a unit operating under cogeneration cycle.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 197-210
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Designing and Modeling of Control Strategies Based on Multi-Objective Optimization for a PMSG Wind Turbine: A Study Based on the Grid Errors and Wind Speed
Autorzy:
Ganji, Ehsan
Mahdavian, Mehdi
Eshaghpour, Iman
Janghorban, Mojtaba
Powiązania:
https://bibliotekanauki.pl/articles/102412.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wind turbine
permanent magnet synchronous generator (PMSG)
output stability of the turbine
resistive depletion load
voltage damping
reduction of switching harmonics
turbina wiatrowa
generator synchroniczny z magnesem trwałym (PMSG)
stabilność wyjściowa turbiny
Opis:
In this paper, an independent wind energy conversion system was studied with the control strategies used to provide power specifically to the areas far from the grid. In this research, three strategies are designed and used in order to stabilize the output. This system contains a directed rectifier which is responsible for maximum power point tracking. Additionally, a common DC bus and a fully controlled inverter were designed. An LC filter was also used in the system in order to eliminate switching harmonics to a considerable extent and provide a reliable noiseless source for load supply. Since the power demand and the produced power of the turbine are variable and indistinguishable in each moment, a depletion load is also placed in the system. In this study, it was observed that the designed strategies prove the output stability in different sections and under different conditions with resonators and non-linear PI and PID controllers. The designed strategies were also supported by the simulation results.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 4; 60-69
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Data-driven techniques for the fault diagnosis of a wind turbine benchmark
Autorzy:
Simani, S.
Farsoni, S.
Castaldi, P.
Powiązania:
https://bibliotekanauki.pl/articles/330715.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
fault diagnosis
analytical redundancy
fuzzy system
neural network
residual generator
fault estimation
wind turbine benchmark
diagnostyka uszkodzeń
redundancja analityczna
system rozmyty
sieć neuronowa
estymacja błędu
turbina wiatrowa
Opis:
This paper deals with the fault diagnosis of wind turbines and investigates viable solutions to the problem of earlier fault detection and isolation. The design of the fault indicator, i.e., the fault estimate, involves data-driven approaches, as they can represent effective tools for coping with poor analytical knowledge of the system dynamics, together with noise and disturbances. In particular, the proposed data-driven solutions rely on fuzzy systems and neural networks that are used to describe the strongly nonlinear relationships between measurement and faults. The chosen architectures rely on nonlinear autoregressive models with exogenous input, as they can represent the dynamic evolution of the system along time. The developed fault diagnosis schemes are tested by means of a high-fidelity benchmark model that simulates the normal and the faulty behaviour of a wind turbine. The achieved performances are also compared with those of other model-based strategies from the related literature. Finally, a Monte-Carlo analysis validates the robustness and the reliability of the proposed solutions against typical parameter uncertainties and disturbances.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2018, 28, 2; 247-268
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies