Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "three-phase current" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Influence of the external proximity effect on the power losses in flat three phase high current busduct
Autorzy:
Piątek, Z.
Szczegielniak, T.
Kusiak, D.
Powiązania:
https://bibliotekanauki.pl/articles/97507.pdf
Data publikacji:
2011
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
active power
reactive power
Bessel function
three phase current busduct
Opis:
In the paper the influence of the external proximity effect on the active and reactive power in flat three phase high current busduct were presented. Calculations were made using the Poynting theorem and Joule-Lenz law.
Źródło:
Computer Applications in Electrical Engineering; 2011, 9; 34-44
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The first three-phase current power plant in Warsaw and its creator Marian Lutosławski (1871-1918)
Autorzy:
Hickiewicz, J.
Rataj, P.
Powiązania:
https://bibliotekanauki.pl/articles/2056332.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrownia
prąd trójfazowy
historia elektrotechniki
historia Warszawy
power plant
three-phase current
history of electrical engineering
history of Warsaw
Opis:
The article describes the first Polish three-phase current power plant designed for lighting of the 2nd Hygienic Exhibition in Warsaw in 1896. A designer and creator of the power plant and the entire electrical installation was Marian Lutosławski, one of the most active Polish electrical engineering specialists during the period of Partitions at the territory of Poland.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 2, 118; 1--6
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspect of the elliptical field in the screened flat three-phase high current busduct. Part I - In the internal area of the screen
Aspekt pola eliptycznego w ekranowanym płaskim trójfazowym torze wielkoprądowym. Część I - W obszarze wewnętrznym ekranu
Autorzy:
Kusiak, D.
Piątek, Z.
Szczegielniak, T.
Powiązania:
https://bibliotekanauki.pl/articles/376450.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
elliptical field
screened flat three-phase high current busduct
high current busduct
external proximity effect
internal proximity effect
Opis:
The paper shown the elliptical magnetic field in the high current screened busduct in the case of the both the external and internal proximity effect. For the characterisation of complex vector values for such a field it is proposed that the length of the longer ellipse semi axis as indicated by the end of the vector within one period be used. Part I describes of elliptic field in the internal area of the screen of the flat three-phase high current busduct.
W artykule przedstawiono eliptyczne pole magnetyczne występujące w ekranowanym torze wielkoprądowym w przypadku zewnętrznego i wewnętrznego zjawiska zbliżenia. Do charakteryzowania wartości zespolonego wektora takiego pola zaproponowano długość dłuższej półosi elipsy jaką zakreśla koniec tego wektora w ciągu jednego okresu. Część I opisuje pole eliptyczne w obszarze wewnętrznym ekranu trójfazowego płaskiego toru wielkoprądowego.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 127-134
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
Autorzy:
Turzyński, M.
Banach, P.
Murawski, P.
Pepliński, R.
Chrzan, P. J.
Powiązania:
https://bibliotekanauki.pl/articles/200484.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resonant converters
ZVS three-phase inverter
current estimation
Opis:
Control of parallel quasi resonant dc link inverters (PQRDCLI) is usually based on dc link input inverter current. Instead of a direct measurement of this noise sensitive and fast changing current signal - its estimation with one step prediction may be considered. Estimation of an input inverter current is based on inverter output current measurements, applied in most of power electronics controlled ac drives. In this paper, the PQRDCLI fed induction motor (IM) with a predictive current estimation stabilizes resonant inverter output voltage slopes du/dt independently of load. By control of output voltage derivatives, reduction of overvoltage spikes and common mode motor currents is achieved. An analysis of the PQRDCLI control with a predictive current estimation strategy is verified by the Saber system simulation and experimental tests in a laboratory setup.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 757-762
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current limiting algorithm for three-phase grid-connected inverters
Autorzy:
Tran, Tho Quang
Powiązania:
https://bibliotekanauki.pl/articles/2135740.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current limitation
negative sequences
reactive power compensation
three-phase grid-connected inverter
unbalanced voltages
Opis:
Grid-connected inverters are commonly used in systems of renewable energy to convert this energy source into AC power with parameters suitable for connection to the grid. In the normal operating conditions, the grid-connected inverters mainly generate active power to the grid. However, when a voltage sag or voltage imbalance occurs, the grid voltage imbalance in the conventional control methods causes negative sequence components and increases the output current magnitude of inverters. The increase of current can damage power semiconductor devices. This paper presents a strategy to limit the current magnitude of inverters under unbalanced grid voltage conditions. In this strategy, a multiple-complex-coefficient filter is used to eliminate the negative sequence voltage components. This method does not require any additional hardware. A three-phase gridconnected photovoltaic inverter system using a solar array of 20 kWp is also used for the survey. The effectiveness has been validated when comparing the simulation results on Matlab/Simulink of the proposed method with those of the conventional method.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 559--579
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa i przykładowe zastosowanie stanowiska pomiaru i rejestracji prądów i napięć w instalacjach trójfazowych
Design and sample application stand of measurement and registration currents and voltages in three-phase mains
Autorzy:
Uździcki, W.
Chciuk, M.
Bachman, P.
Aksentowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/276799.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pomiary
rejestracja
napięcie
prąd
moc
sieć trójfazowa
siła skrawania
measurement
recording
voltage
current
power
three-phase mains
cutting force
Opis:
W artykule opisane jest stanowisko do pomiarów i rejestracji podstawowych parametrów sieci trójfazowych. Opisano w nim budowę stanowiska pomiarowego a następnie zależności matematyczne dotyczące mierzonych sygnałów. W końcowej części artykułu przedstawiono wyniki przykładowych pomiarów.
This paper describes a stand to measure and record the basic parameters of the three-phase mains. Describes the construction of measuring stand and mathematical relations of the measured signals. Finally, the paper presents the results of the sample measurements.
Źródło:
Pomiary Automatyka Robotyka; 2013, 17, 2; 525-529
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Armature MMF and electromagnetic performance analysis of dual three-phase 10-pole/24-slot permanent magnet synchronous machine
Autorzy:
Chen, Zhenfei
Xing, Ning
Ma, Hongzhong
Li, Zhixin
Li, Jiayu
Fan, Chenyang
Powiązania:
https://bibliotekanauki.pl/articles/2202550.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dual three-phase winding
fractional-slot
concentrated winding
permanent magnet synchronous machines (SCW-PMSMs)
MMF harmonic analysis
space harmonics
magnet eddy-current loss (ECL)
SVPWM voltage supply
Opis:
Fractional-slot concentrated-winding permanent magnet synchronous machines (FSCW-PMSMs) have a good prospect of application in the drive system of electric and hybrid electric vehicles. However, the armature magnetomotive force (MMF) of FSCWPMSM contains a large number of space harmonics, which induce large magnet eddycurrent loss (ECL). To solve this problem, a dual three-phase 10-pole and 24-slot winding layout is proposed.MMFharmonic analysis shows that the 1st, 7th and 17th space-harmonic winding factors of the proposed winding can be reduced by 100%, 87% and 87% respectively, compared with a dual three-phase 10-pole and 12-slot winding. Electromagnetic performances of the proposed machine under rated sinusoidal current supply and space vector pulse-width-modulated (SVPWM) voltage supply are investigated based on 2D finite-element analysis. It is shown that the proposed machine can meet the requirement of torque and efficiency in the full speed range. Especially, magnet ECL can be reduced greatly due to the reduction of the 7th and 17th space harmonics.
Źródło:
Archives of Electrical Engineering; 2023, 72, 1; 189--210
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies