Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "short-circuit time" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Finding short-circuit current time based on raw data
Autorzy:
Książkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/376962.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
overcurrent
Scilab
histogram
short-circuit time
Opis:
Series of tests were conducted in which short-circuit current was registered. Four different overcurrent protection devices were used for a set value of prospective current. Based on obtained data the short-circuit time was calculated. In order to obtain this information a procedure was developed. Later it was implemented with the help of numerical computation software Scilab. In this paper results of calculations, the procedure itself and its implementation are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 82; 213-218
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czasy wyłączania magnetowydmuchowych wyłączników szybkich prądu stałego
Switching-off Time of Electromagnetic Blow-out High-speed DC Circuit Breaker
Autorzy:
Rojek, A.
Powiązania:
https://bibliotekanauki.pl/articles/215436.pdf
Data publikacji:
2015
Wydawca:
Instytut Kolejnictwa
Tematy:
wyłącznik szybki
zwarcia
czas własny
czas łukowy
high-speed circuit breaker
short-circuit
opening time
arcing time
Opis:
Wyłączniki szybkie są podstawowym zabezpieczeniem przed przepływem nadmiernych wartości prądu w obwodach sieci trakcyjnej oraz zasilanych z niej pojazdów. Prądy zwarciowe muszą być wyłączone w jak najkrótszym czasie, aby zminimalizować ryzyko uszkodzenia chronionych przez wyłączniki elementów systemu zasilania trakcji elektrycznej. Jednym z istotnych parametrów wyłącznika szybkiego jest czas wyłączania prądu, określany od chwili przekroczenia przez prąd nastawy wyzwalacza wyłącznika do chwili wyłączenia prądu. Zakres badań wyłączników szybkich prądu stałego na zgodność z normami obejmuje określenie tego czasu jedynie dla dużych wartości prądu, znacznie przekraczających poziom prądów roboczych, oraz dla prądów o wartości bardzo małej – prądów krytycznych. Podczas eksploatacji wyłączników szybkich najwięcej wyłączeń następuje w wyniku zwarć odległych lub przeciążeń. W celu określenia rzeczywistych czasów wyłączania prądów o wartościach porównywalnych z poziomem nastawy wyzwalacza wyłącznika szybkiego, przeprowadzono badania przy różnych wartościach stałej czasowej obwodu, w wyniku których określono czas łukowy oraz czas własny wyłącznika w zależności od wartości wyłączanego prądu. Badaniom poddano magnetowydmuchowy wyłącznik szybki prądu stałego typu BWS, który jest najczęściej używanym w Polsce wyłącznikiem w podstacjach trakcyjnych i kabinach sekcyjnych.
The high-speed circuit breakers are an essential safeguard against the flow of an excessive current in the circuit overhead line and vehicles being powered by it. The short circuit currents must be switched off as soon as possible to minimize the risk of damage, protected by circuit breakers, elements of an electric traction power supply system. The switching-off time is one of the main parameters of high-speed circuit- breaker. This time is specified from moment of exceeding of the circuit breaker tripping level by the current until cut off the current. The scope of high-speed DC circuit breakers tests for compliance with standards includes determining this time only for large currents, greatly exceeding the operating currents, and the currents of the very small – critical currents. However, during exploitation of high-speed circuit-breakers many faults clearance occurs by distant short-circuits or overloads. In order to determine the actual switching times of currents, which values are comparable with the tripping level researches and tests were performed for different values of the time constant, which were base of specifying value of arcing and opening time, depending on the value of breaking currents. The study involved electromagnetic blow-out high-speed DC circuit breaker BWS type, which is the most common breaker in traction substations and sectioning cabins in Poland.
Źródło:
Problemy Kolejnictwa; 2015, 169; 53-60
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrochemical grinding of titanium-containing materials
Autorzy:
Przystupa, K.
Litak, G.
Powiązania:
https://bibliotekanauki.pl/articles/102219.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hybrid processes
electrochemical grinding (ECG)
micro short-circuit
time-frequency analysis
Opis:
The paper focuses on machining difficult-to-cut materials where a significant component is titanium. The paper discusses a complex process of electrochemical grinding (ECG). A practical example was given by discussing the results of ECG. Selected difficult-to-cut materials, along with their typical ECG properties, were compared. In addition, the paper discusses the phenomenon of micro short-circuits constituting a form of an interference characteristic for the process. The results presented in the paper refer to the phenomenon of a micro short-circuits, i.e. the case when a rapid and uncontrolled electrical discharge occurs in the machining zone. The paper presents examples of recorded micro short-circuits and attempts a time-frequency analysis regarding the occurrence of the disturbance. To reveal the dynamics of the ECG process we applied wavelet analysis.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 183-188
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stator Winding Fault Detection of Permanent Magnet Synchronous Motors Based on the Short-Time Fourier Transform
Autorzy:
Pietrzak, Przemysław
Wolkiewicz, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2175935.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fault diagnosis
condition monitoring
inter-turn short circuit
permanent magnet synchronous motor
short-time Fourier transform
Opis:
In modern drive systems, the high-efficient permanent magnet synchronous motors (PMSMs) have become one of the most substantial components. Nevertheless, such machines are exposed to various types of faults. Hence, on-line condition monitoring and fault diagnosis of PMSMs have become necessary. One of the most common PMSM faults is the stator winding fault. Due to the destructive character of this failure, it is necessary to use fault diagnostic methods that allow fault detection at its early stage. The article presents the results of experimental studies obtained from fast Fourier transform (FFT) and short-time Fourier transform (STFT) analyses of the stator phase current, stator phase current envelope and stator phase current space vector module. The superiority of the proposed method over the classical approach based on the stator current analysis using FFT is highlighted. The proposed solution is experimentally verified under various motor operating conditions. The application of STFT analysis discussed so far in the literature has been limited to the fault diagnosis of induction motors and the narrow range of the analysed motor operating conditions. Moreover, there are no works in the field of motor diagnostics dealing with STFT analysis for stator windings based on the stator current envelope and the stator current space vector module.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 112--133
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Universal Current Transformer for Accurate Measurement of Short-circuit Currents
Uniwersalny przekładnik prądowy do dokładnego pomiaru prądów zwarciowych
Autorzy:
Przybysz, J.
Olak, J.
Piątek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397436.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
current transformer
aperiodic time constant
short circuit tests
przekładnik prądowy
aperiodyczna stała czasowa
badania zwarciowe
Opis:
The paper presents the design of a special current transformer developed by the Institute of Power Engineering in cooperation with TRANSFORMEX sp. z o.o. The aim of the project was to obtain current transformers allowing not only a thorough transformation of symmetrical currents – which is characteristic for typical current transformers, but also of asymmetrical shortcircuit currents containing an aperiodic component, which are not reproduced by classic current transformers. A current transformer has been developed with a range of short-circuit currents established from 1 kA to 50 kA, and short-circuit currents with an aperiodic component with a decay time constant up to 200 ms, peak value from 2.5 kA to 125 kA, assuming the possibility of five-fold repetition of short circuits with the same value and the same constant component polarity, with the assumed transformation accuracy.
W artykule przedstawiono konstrukcję specjalnego przekładnika prądowego opracowanego we współpracy Instytutu Energetyki z firmą TRANSFORMEX sp. z o.o. Celem pracy było uzyskanie przekładników prądowych umożliwiających nie tylko dokładną transformację prądów przemiennych ustalonych – co jest znamienne dla typowych przekładników prądowych, ale również niesymetrycznych prądów zwarciowych zawierających składową bezokresową, których klasyczne przekładniki prądowe nie odtwarzają. Opracowano przekładnik prądowy o zakresie prądów zwarciowych ustalonych od 1 kA do 50 kA oraz prądów zwarciowych ze składową bezokresową o stałej czasowej zanikania do 200 ms, o wartości szczytowej od 2,5 kA do 125 kA, przy przyjęciu możliwości pięciokrotnego powtarzania zwarć tej samej wartości i tej samej biegunowości składowej stałej, przy założonej dokładności transformacji.
Źródło:
Acta Energetica; 2017, 1; 101-106
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of ITSC fault in the electrical vehicle powertrain system through signal processing analysis
Autorzy:
Ouamara, Dehbia
Boukhnifer, Moussa
Chaibet, Ahmed
Maidi, Ahmed
Powiązania:
https://bibliotekanauki.pl/articles/2174472.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
induction motor
electrical vehicle
fault diagnosis
inter-turn short circuit
extended Kalman filter
spectral analysis
fast Fourier transform
short-time Fourier transform
silnik indukcyjny
pojazd elektryczny
diagnostyka uszkodzeń
zwarcie międzyzwojowe
rozszerzony filtr Kalmana
analiza spektralna
szybka transformata Fouriera
krótkoczasowa transformata Fouriera
Opis:
The three-phase induction motor is well suited for a wide range of mobile drives, specifically for electric vehicle powertrain. During the entire life cycle of the electric motor, some types of failures can occur, with stator winding failure being the most common. The impact of this failure must be considered from the incipient as it can affect the performance of the motor, especially for electrically powered vehicle application. In this paper, the intern turn short circuit of the stator winding was studied using Fast Fourier transform (FFT) and Shor-Time Fourier transform (STFT) approaches. The residuals current between the estimated currents provided by the extended Kalman filter (EKF) and the actual ones are used for fault diagnosis and identification. Through FFT, the residual spectrum is sensitive to faults and gives the extraction of inter-turn short circuit (ITSC) related frequencies in the phase winding. In addition, the FFT is used to obtain information about when and where the ITSC appears in the phase winding. Indeed, the results allow to know the faulty phase, to estimate the fault rate and the fault occurrence frequency as well as their appearance time.
Źródło:
Diagnostyka; 2023, 24, 1; art. no. 2023113
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies