Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "pseudo-static" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Seismic material properties of reinforced concrete and steel casing composite concrete in elevated pile-group foundation
Autorzy:
Zhou, M.
Yuan, W.
Zhang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/963367.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
pseudo-static tests
material properties
reinforced concrete
steel composite concrete
Opis:
The paper focuses on the material mechanics properties of reinforced concrete and steel casing composite concrete under pseudo-static loads and their application in structure. Although elevated pile-group foundation is widely used in bridge, port and ocean engineering, the seismic performance of this type of foundation still need further study. Four scale-specimens of the elevated pile-group foundation were manufactured by these two kinds of concrete and seismic performance characteristic of each specimen were compared. Meanwhile, the special soil box was designed and built to consider soil-pile-superstructure interaction. According to the test result, the peak strength of strengthening specimens is about 1.77 times of the others and the ultimate displacement is 1.66 times of the RC specimens. Additionally, the dissipated hysteric energy capability of strengthening specimens is more than 2.15 times of the others as the equivalent viscous damping ratio is reduced by 50%. The pinching effect of first two specimens is more obvious than latter two specimens and the hysteretic loops of reinforced specimens are more plumpness. The pseudo-static tests also provided the data to quantitatively assessment the positive effect of steel casing composite concrete in aseismatic design of bridge.
Źródło:
Polish Maritime Research; 2015, S 1; 141-148
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seismic bearing capacity of shallow strip footing embedded in slope resting on two-layered soil
Autorzy:
Debnath, Litan
Powiązania:
https://bibliotekanauki.pl/articles/1845145.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pseudo-static
particle swarm optimisation
bearing capacity coefficient
slope inclination
limit equilibrium
Opis:
In this paper, the limit equilibrium method with the pseudo-static approach is developed in the evaluation of the influence of slope on the bearing capacity of a shallow foundation. Particle swarm optimisation (PSO) technique is applied to optimise the solution. Minimum bearing capacity coefficients of shallow foundation near slopes are presented in the form of a design table for practical use in geotechnical engineering. It has been shown that the seismic bearing capacity coefficients reduce considerably with an increase in seismic coefficient. Besides, the magnitude of bearing capacity coefficients decreases further with an increase in slope inclination.
Źródło:
Studia Geotechnica et Mechanica; 2021, 43, 3; 285-306
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stability analysis of the slope subjected to the dynamic loading
Autorzy:
Zabuski, Lesław
Powiązania:
https://bibliotekanauki.pl/articles/27311343.pdf
Data publikacji:
2023
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
slope stability
landslide
pseudo-static analysis stability
stabilność zbocza
osuwisko
analiza pseudostatyczna stateczności
Opis:
This paper presents the results of a stability analysis of a slope located in the immediate vicinity of a railway line. The plans for the extension of this railway track include the construction of another line, which would run parallel to the existing one, within a few metres distance. It is expected that intensive goods train traffic will generate both static and dynamic forces in the underlying subsoil. Consequently, seismic vibrations will be generated in the subsoil, propagating mainly not only in the horizontal direction but also in the vertical direction. The method of seismic coefficient of the earthquake intensity determined by a pseudo-static method and horizontal component of acceleration is appropriate and recommended because it is simple, and the safety factor of the slope is calculated in the same way as in conventional stability calculations.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2023, 118; 243--255
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pseudo-static experiment and analysis on seismic behavior of the RC columns strengthened by GHPFRCC
Autorzy:
Li, X.
Wang, J.
Luo, M.
Powiązania:
https://bibliotekanauki.pl/articles/259179.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
green high performance fiber reinforced cementitious composites (GHPFRCC)
pseudo-static test
reinforced concrete column
strengthening
seismic performance
Opis:
Green high performance fiber reinforced cementitious composites (GHPFRCC) are a new class of sustainable cementitious composites, employing a high volume of fly ash to replace cement. In addition to increasing the sustainability of the construction environment, GHPFRCC exhibits a high tensile ductility and multiple cracking behaviors in the strainhardening state. These materials can effectively improve the structural energy dissipation capacity and structural durability. In this study, the optimum mixture ratio of GHPFRCC is presented established using an orthogonal experiment for a specific engineering application. The described GHPFRCC sustains the mechanical performance of concrete and is employed as the outer cladding to strengthen concrete columns. The finite element analysis of the material was based on the software ABAQUS and pseudo static experiments were conducted to exhibit retrofitting of GHPFRCC applied in the rehabilitation of seismic-damaged concrete columns. The computed and experimental results showed that GHPFRCC, while incorporating high volume fly ash, can retain significant multiple cracking behaviors. The energy dissipation capacity of the GHPFRCC reinforced concrete (RC) column is better than the comparable unreinforced column.
Źródło:
Polish Maritime Research; 2015, S 1; 56-60
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An innovative safety format for structural system robustness checking
Innowacyjny format bezpieczeństwa oceny odporności konstrukcji
Autorzy:
Tur, Andrei
Tur, Viktar
Derechennik, Stanislav
Lizahub, Aliaksandr
Powiązania:
https://bibliotekanauki.pl/articles/390770.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
robustness
progressive collapse
reliability
safety format
pseudo-static response
odporność
katastrofa postępująca
niezawodność
format bezpieczeństwa
technologia pseudostatyczna
Opis:
The estimation of structural robustness remains one of the most important stages of the design of structural systems. Recommended design strategies for the robustness assessment are based on the provisions specified in the actual EN 1991-1-7 and ISO 2394:2015. Currently, the EN 1991-1-7 and ISO2394:2015 allows the use of indirect tie-force method, but normally, non-linear pseudo-static analysis is widely used, because it is based on more realistic constitutive relations for basic variables, which enables a simulation of the real structural behaviour. Implementation of the non-linear pseudo-static analysis for the assessment of a structural system in accidental design situations requires to adopt a different approach to safety format. The paper presents an innovative approach to safety format calibration for non-linear analysis of RC-structures subjected to accidental loads. The proposed method of the robustness estimation is based on the joint energy-saving (conversion) approach and the full probabilistic method for the estimation of a safety format for pseudo-static non-linear response of modified (damaged) structural system. The proposed probabilistic considerations are based on the Order Statistic Theory.
Ocena odporności konstrukcji jest jednym z najważniejszych etapów projektowania konstrukcji budowlanych. Zalecane strategie projektowania odporności kontrukcji bazują na postanowieniach obowiązujących norm: EN 1991-1-7 i ISO 2394:2015. Obecnie normy EN 1991-1-7 i ISO2394:2015 pozwalają na użycie metody pośredniej więzi łączących (TF method), ale zwykle używana jest nielinearna analiza psedostatyczna, ponieważ bazuje na bardziej realistycznych związków konstytutywnych dla podstawowych zmiennych, co umożliwia symulację prawdziwego zachowania konstrukcji. Użycie nielinearnej analizy pseudostatycznej do oceny konstrukcji budowlanych w przypadku oddziaływań wyjątkowych wymaga użycia innego podejścia do formatu bezpieczeństwa. Artykuł przedstawia innowacyjne podejście do kalibracji formatu bezpieczeństwa dla nielinearnej analizy żelbetowych konstrukcji poddanych wyjątkowym obciążeniom. Proponowane metody oceny odporności na zniszczenie bazują na połączony podejściu energooszczędnym (konwersji) i pełnej metodzie probabilistycznej oceny bezpieczeństwa pseudostatycznej, nielinearnej odpowiedzi zmienionej (uszkodzonej) konstrukcji budowlanej. Zaproponowane rozważania bazują na statystykach porządkowych.
Źródło:
Budownictwo i Architektura; 2020, 19, 4; 67-84
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Seismic Bearing Capacity of a Strip Footing Resting on Reinforced Earth Bed using Pseudo-Static Analysis
Autorzy:
Jaiswal, Sagar
Chauchan, Vinay Bhusan
Powiązania:
https://bibliotekanauki.pl/articles/2051717.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
reinforced earth
bearing capacity
strip footing
finite element method
pseudo-static analysis
wzmocnienie podłoża
nośność
ława fundamentowa
metoda elementów skończonych
analiza pseudostatyczna
Opis:
The use of geosynthetic reinforcement to enhance the ultimate load-bearing capacity and reduce the anticipated settlement of the shallow foundation has gained sufficient attention in the geotechnical field. The improved performance of the shallow foundation is achieved by providing one or more layers of geosynthetics below the foundation. The full wraparound technique proved to be efficient for the confinement of soil mass and reduction in settlement of foundation however lacks the literature to ascertain the performances of such footing under dynamic loading. In view of the above, the present study examines the effect of geosynthetic layers having a finite length with full wraparound ends as a reinforcement layer, placed horizontally at a suitable depth below the foundation using the finite element modeling (FEM) and evaluates the ultimate load-bearing capacity of a strip footing resting on loose and dense coarse-grained earth beds under seismic loading and further compared to those of footing resting on unreinforced earth bed. Moreover, the effect of horizontal seismic acceleration coefficient (kh) on the ultimate load-bearing capacity has been investigated by varying kh from 0.1 to 0.6 at an interval of 0.1, for both reinforced and unreinforced earth bed having loose and dense soil strata. Furthermore, this study demonstrates that by adopting the new practice of using the geosynthetic reinforcement with the full wraparound ends in foundations, it is possible to support relatively heavier structures under static as well as dynamic loading without allowing large footing settlements. From the outcomes of the present study, it is noted that the ultimate load-bearing capacity of footing resting on loose and dense sand bed found to be improved by 60% and 18% for soils having friction angle of 25° and 40°, respectively compared to respective unreinforced earth beds under static condition.
Źródło:
Civil and Environmental Engineering Reports; 2021, 31, 2; 117-137
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Critical seismic coefficients of homogeneous earth dams prediction by a FELA-ANN approach
Autorzy:
Abdelatif, Zeroual
Ali, Fourar
Messaoud, Djeddou
Powiązania:
https://bibliotekanauki.pl/articles/122272.pdf
Data publikacji:
2019
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
critical seismic coefficient
pseudo-static analysis
finite element limit analysis
artificial neural network
homogeneous earth dams
sztuczna sieć neuronowa
jednorodne zapory ziemne
współczynnik sejsmiczny
Opis:
In this research study, a combination of lower and upper bound finite element limit analysis (FELA) and artificial neural network (ANN) has been adopted in order to forecast critical seismic coefficients (kc) of homogeneous earth dams (HED) subjected to pseudo-static seismic loading. To achieve this, the results of kc obtained by OptumG2 software were used in the development of the ANN and MR models. The ANN models have shown higher prediction performance than the MR models based on the performance indices. The most appropriate architecture was found 8-14-1, as this gave the best kc predict with the minimum statistical measures of error and the high determination coefficient (> 99%). Consequently, the ANN model can be used to easily and accurately predict kc value of the HED as the best substitute for the conventional methods.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2019, 18, 3; 5-16
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Blast-induced Ground Vibration on Factor of Safety of Pit Wall Stability
Wpływ wibracji gruntu wywołanych podmuchami na współczynnik bezpieczeństwa stabilności zboczy odkrywki
Autorzy:
Jaroonpattanapong, P.
Pantachang, K.
Thungfung, S.
Petthong, N.
Powiązania:
https://bibliotekanauki.pl/articles/319343.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
blast-induced ground vibration
slope stability
factor of safety
limit equilibrium analysis
pseudo-static analysis
wibracje gruntu wywołane podmuchami
stateczność zbocza
współczynnik bezpieczeństwa
analiza równowagi granicznej
analiza pseudostatyczna
Opis:
The regulated maximum peak particle velocity (PPV) from blasting operations of an open-pit coal mine is less than 2 mm/s to prevent mainly any public disturbance such as ground vibration and air blast. However, the blast-induce ground vibration can also decrease the stability of pit slope, which has not been intensively studied. A claystone pit wall, which is geotechnically investigated as having a plane failure type and the natural condition factor of safety (FS), has been selected for this study. The FS is selected to measure the effect of blast-induced ground vibration on the slope stability. The limit equilibrium, pseudo-static 1 (), and pseudo-static 2 () methods are used to determine the FS. The vibration results of blasting monitored at three slope positions: crest, middle, and toe, from two areas at the same pit wall, are recorded by blasting seismographs. Maximum charge weight per delay and the distance from blast areas to seismographs are collected to construct the scaled distance. The percentage change of FS of three methods from both areas compared to natural condition FS are all less than 4 percent considered that the slope stability is safe from blasting vibration (less than 15 percent). The relationship between the FS and maximum PPV from the limit equilibrium, pseudo-static 1 (), and pseudo-static 2 () methods indicate that the adverse maximum PPVs given the unity FS are 16.60 and 4.58, and 4.74 mm/s, respectively. The regulated PPV less than 2 mm/s at the mine is reasonable to prevent any possible plane failure. However, many impact parameters have not been included in this study, and their effects may disturb the pit wall stability.
Regulowana maksymalna szczytowa prędkość cząstek (PPV) z operacji wybuchowych w kopalni odkrywkowej wynosi mniej niż 2 mm / s, aby zapobiec głównie wszelkim zakłóceniom społecznym, takim jak wibracje gruntu i podmuch powietrza. Jednak wibracje gruntu wywołane podmuchami mogą również zmniejszyć stabilność zbocza wykopu, co nie było intensywnie badane. Do badania wybrano ścianę iłowca, która została zbadana geotechnicznie jako mająca typ zniszczenia płaskiego i znana jako naturalny współczynnik bezpieczeństwa (FS). FS jest wybierany do pomiaru wpływu wibracji gruntu wywołanych podmuchami na stabilność zbocza. Równowaga graniczna, metody pseudo-statyczne 1 (kH) i pseudostatyczne 2 (kH, kv) są używane do wyznaczania FS. Wyniki drgań robót strzałowych monitorowane w trzech położeniach zboczy: w wierzchołku, w środku i na palcach z dwóch obszarów na tej samej ścianie wykopu są rejestrowane za pomocą sejsmografów strzałowych. Maksymalny ciężar ładunku na opóźnienie i odległość od obszarów wybuchu do sejsmografów są zbierane w celu obliczenia wyskalowanej odległości. Procentowa zmiana FS trzech metod z obu obszarów w porównaniu ze stanem naturalnym FS wynosi mniej niż 4 procent, co oznacza, że stabilność zbocza jest bezpieczna przed drganiami wybuchowymi (mniej niż 15 procent). Zależność między FS i maksymalnym PPV z równowagi granicznej, pseudo- statyczna 1 (kH) i pseudo-statyczna 2 (kH, kv) wskazuje, że niekorzystne maksymalne PPV przy jednostkowej FS wynoszą 16,60 i 4,58 oraz 4,74 mm / s, odpowiednio. Regulowany PPV poniżej 2 mm / s w kopalni jest rozsądnym rozwiązaniem, aby zapobiec możliwej awarii. Jednak wiele parametrów uderzenia nie zostało uwzględnionych w tym badaniu, a ich wpływ może naruszyć stabilność zboczy odkrywki.
Źródło:
Inżynieria Mineralna; 2020, 1, 2; 147-154
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pseudo-static test of steel-glulam composite beam-to-column exterior joints
Autorzy:
Duan, Shaowei
Liu, Xinglong
Yuan, Jian
Wang, Zhifeng
Powiązania:
https://bibliotekanauki.pl/articles/1853633.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
połączenie belka-słup
połączenie zewnętrzne
belka stalowa klejona
belka kompozytowa
test pseudostatyczny
forma przekroju
rozpraszanie energii
nośność
beam to column joint
exterior joint
steel-glulam beam
composite beam
pseudo-static test
cross-section form
energy dissipation
capacity
Opis:
Steel-glulam structure is a new type of composite structure,glulam have lateral support effect on steel plate, that can prevent premature buckling of steel plate and improve the stability of steel structure. In order to study the influence of column’s cross-section form on the seismic performance of steel-glulam composite beam-to-column exterior joint, the column’s cross-section form was taken as the basic variable (glulam rectangular section , H-beam section and H-beam-glulam rectangular section were used respectively). The pseudo-static tests of three composite beam-to-column joints were carried out to observe the different failure modes, and obtain the mechanical performance indexes. The experiment results demonstrated that: The energy dissipation capacity of beam-to-column exterior joint composed of glulam column was the worst, the ultimate bearing capacity and stiffness were the lowest. The ultimate bearing capacity of the exterior joints formed by the H-beam column and the H-beam-glulam composite column were both high, and their ductility coefficients were similar, while the former had better energy dissipation capacity.
Źródło:
Archives of Civil Engineering; 2021, 67, 1; 147-161
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies