Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power lines" wg kryterium: Temat


Tytuł:
Identification of objects based on metric images as an effective diagnostic tool used in power engineering
Autorzy:
Gasz, R.
Powiązania:
https://bibliotekanauki.pl/articles/377230.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electric power lines
power engineering
Opis:
The paper presents the method for semi-automatic diagnostics of support structures for high voltage lines with use of metrical photographs. Diagnostics of electric power lines is an important component of their operation and consists of determination which components of the support structures need repairs or maintenance. However, it is a very time-consuming and usually really expensive process. Therefore this paper discloses the method that may make it easier to determine current technical condition of poles since it consists in comparison of real photos against virtual patterns that are developed on the basis of 3D models worked out from technical documentation. The proposed method makes it possible to analyze data that have been collected beforehand or can be applied online to carry out real-time investigations. However, application of the method in the on-line mode would enable much faster selection of poles for further assessment of them.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 74; 87-94
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Possibilities to Reduce the Voltages Induced in Multi-circuit and Multi-voltage Overhead Lines
Analiza możliwości redukcji napięć indukowanych w wielotorowych wielonapięciowych liniach napowietrznych
Autorzy:
Tarko, R.
Szpyra, W.
Nowak, W.
Powiązania:
https://bibliotekanauki.pl/articles/396938.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
power lines
multi-circuit power lines
multi-voltage power lines
induced voltage reduction
linie elektroenergetyczne
linie elektroenergetyczne wielotorowe
linie elektroenergetyczne wielonapięciowe
redukcja napięć indukowanych
Opis:
This paper presents the issues of electromagnetic interactions in a four-circuit and dual-voltage power line. Such solutions are increasingly used in practice due to difficulties in land acquisition for the construction of new power lines. Lines of this type, however, have some disadvantages, incl. the electromagnetic interactions between the circuits and voltages induced as their consequence. These issues are considered in relation to an existing four-circuit, 110 kV and 15 kV line. Results of the studies of the interaction effects in a real system, and an analysis of selected ways to reduce the voltage induced in 15 kV line circuits are presented.
W artykule przedstawiono zagadnienia oddziaływań elektromagnetycznych w czterotorowej, dwunapięciowej linii elektroenergetycznej. Rozwiązania takie są coraz częściej stosowane w praktyce, ze względu na trudności w uzyskaniu terenu pod budowę nowych linii elektroenergetycznych. Linie tego typu posiadają jednak również wady, wśród których należy wymienić oddziaływania elektromagnetyczne występujące pomiędzy torami i ich skutki w postaci indukowania napięć. Zagadnienia te rozważono w odniesieniu do istniejącej linii czterotorowej o dwóch poziomach napięć 110 kV i 15 kV. Przedstawiono wyniki badań skutków oddziaływań w układzie rzeczywistym oraz analizę wybranych sposobów redukcji napięć indukowanych w torach linii 15 kV.
Źródło:
Acta Energetica; 2015, 3; 130-141
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elaboration of the 3D Model and Survey of the Power Lines Using Data From Airborne Laser Scanning
Autorzy:
Kwoczyńska, B.
Dobek, J.
Powiązania:
https://bibliotekanauki.pl/articles/124712.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
airborne laser scanning
power lines
survey
Opis:
One of the methods of obtaining highly accurate and current spatial data about the terrain, as well as objects situated on it, is laser scanning. LIDAR (Light Detection and Ranging) is among the most modern, dynamically developing technologies and reveals in surveying new capabilities that have been unachievable in a traditional way so far. The aim of the publication is to show the possibilities of using data from airborne laser scanning to perform the survey and visualization of the energy network, and also identification of hazards which the present network constitutes for the immediate environment using the TerraSolid software package. The survey was conducted for two independent sections of the power line, on the basis of two different clouds of points obtained from the airborne laser scanning. The first one had a density of 16 points/m2, while the other 22 pts/m2. The project was created in an environment of MicroStation V8i software using special overlays – TerraScan and TerraModeler of Finnish TerraSolid Company. The use of the test clouds of different densities was intended to indicate an optimal density of the cloud of points, which allows carrying out a survey and visualization of the energy network based on data derived from airborne laser scanning. The publication presents on particular examples the procedure of vectorization and visualization of the power line and detection of objects within a dangerous distance from it. The possibility of using applied LIDAR data, meeting the industry requirements, to the survey of power lines has been also confirmed.
Źródło:
Journal of Ecological Engineering; 2016, 17, 4; 65-74
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości redukcji napięć indukowanych w wielotorowych liniach napowietrznych
Analysis possibility to reduce tensions induced in multi-circuit overhead lines
Autorzy:
Tarko, R.
Nowak, W.
Szpyra, W.
Powiązania:
https://bibliotekanauki.pl/articles/266594.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
linie elektroenergetyczne wielotorowe
linie elektroenergetyczne wielonapięciowe
redukcja napięć indukowanych
multi-circuit power lines
multi-voltage power lines
reduction of induced voltages
Opis:
W artykule przedstawiono zagadnienia oddziaływań elektromagnetycznych w czterotorowej, dwunapięciowej linii elektroenergetycznej. Rozwiązania takie są coraz częściej stosowane w praktyce, ze względu na istniejące trudności w budowie nowych linii elektroenergetycznych. Rozwiązania takie posiadają również wady, wśród których wymienić należy oddziaływania elektromagnetyczne i ich skutki w postaci indukowania napięć. Zagadnienia te rozważono w odniesieniu do istniejącej linii czterotorowej o dwóch poziomach napięć 110 kV i 15 kV. Przedstawiono wyniki badań skutków oddziaływań w układzie rzeczywistym oraz analizę wybranych sposobów redukcji napięć indukowanych w torach linii 15 kV.
The paper presents the electromagnetic interaction in four-circuit, dual voltage power line. Such solutions are increasingly being applied in practice, due to the difficulties with the acquisition of area for the construction of new power lines. Such solutions have some disadvantages, among which should be mentioned electromagnetic interactions and their consequences in terms of inducing voltage. These issues are considered in relation to the existing four-circuit line of voltage levels of 110 kV and 15 kV. Presents the results of the effects of interactions in a real system and the analysis of selected ways to reduce stress induced in the 15 kV line.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 47-50
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Telescopic Joints in Steel Tube Towers
Autorzy:
Gwóźdź, M..
Kowalski, D.
Powiązania:
https://bibliotekanauki.pl/articles/104741.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
columns
shells
power lines
bearing capacity
reliability
telescopic joint
Opis:
Modeling problems of new generation of steel shell towers supporting overhead power transmission lines and having telescopic joints are presented in this paper. The towers of such structure, designed according to the European standard EN 50341 [8], ensure high reliability even when subjected to high technological and climate loads. In this paper elements of differentiated reliability requirements are verified, and special attention is paid to the values of variable loads coefficients for different reliability classes of the considered structure. Using computer modeling tools and linear, elastic shell theory, the modeling error of telescopic joints in a sample tower supporting overhead power transmission line rated at 110 kV is estimated.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 43-53
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwiększenie możliwości przesyłowych napowietrznych linii elektroenergetycznych z zachowaniem wymaganego poziomu bezpieczeństwa
Increased transmission capabilities of overhead power lines in compliance with the required safety level
Autorzy:
Staszewski, Ł.
Habrych, M.
Powiązania:
https://bibliotekanauki.pl/articles/186015.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
napowietrzne linie elektroenergetyczne
przesył
bezpieczeństwo
overhead power lines
transmission
safety
Opis:
W artykule przedstawiono możliwość wykorzystania Dynamicznej Obciążalności Linii w celu zwiększenia możliwości przesyłowych istniejących linii napowietrznych z jednoczesnym zachowaniem wymaganych norm bezpieczeństwa. Zaprezentowano również poprawione działanie zabezpieczenia odległościowego wyposażonego w nowy algorytm rozpoznający kontrolowane przeciążenie i odróżniający je od sytuacji awaryjnych.
The article presents the possibilities to use Dynamic Power Line Rating to increase transmission capabilities of the existing overhead power lines, in compliance with the required safety standards. Additionally, the authors discussed the revised operation of distance protection equipped with a new algorithm which is able to recognize controlled overload and distinguish it from failures.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2014, R. 52, nr 5, 5; 28-35
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power line magnetic field mitigation using a passive loop conductor
Autorzy:
Budnik, K.
Machczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/376311.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
magnetic field
electric field
electric power lines
Fourier transform
loop conductor
Opis:
The paper presents in a tutorial manner methods of the calculation of magnetic fields in vicinity of overhead electric power lines without and with passive mitigation loops. Exact and simplified methods of the determination of the magnetic field of a straight overhead conductor based on the Fourier transform technique are presented. The mitigation effects due to the passive loop are also investigated, whereas the mitigation loop can be treated as a rectangular loop (two-conductor closed mitigation loop) horizontal located under the power line. The decomposition of the magnetic fields in two components: magnetic field obtained in free space from the Biot-Savart law and the magnetic field produced by earth current shows that in practical cases the effects from earth currents can be neglected as compared with effects from line currents.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 73; 137-145
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High incidence of acute leukemia in the proximity of some industrial facilities in El Bierzo, northwestern Spain
Autorzy:
Rodríguez-García, José A.
Ramos, Fernando
Powiązania:
https://bibliotekanauki.pl/articles/2180111.pdf
Data publikacji:
2012-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
acute leukemia
Benzo(a)pyrene
industrial facilities
electromagnetic radiation
power lines
thermoelectric power plant
Opis:
Objectives: To estimate the incidence of acute leukemia (AL) in El Bierzo (BZ) and to carry out a cross-association analysis in order to suggest some etiological clues. Materials and Methods: We registered all new AL cases diagnosed 2000–2005. Annual standardized incidence rate (SIR) was calculated by the direct method. A cross-association analysis was performed by non-parametric methods and we checked the potential interaction between putative etiological factors by calculating Chi-square-for-trend. Results: SIR was 5.1 cases per 100 000, surpassing the Spanish, European and world average figures and heterogeneous throughout the region. We detected a negative correlation between acute myeloblastic leukemia (AML) SIR in every municipality and both the air distance to the nearest thermoelectric power plant (TPP) (Rho = –0.409; p = 0.01) and to the point of maximum density of the high-power lines (HPL) network (Rho = –0.329; p = 0.04). Accordingly, SIR was higher in the municipalities situated < 7.5 km away from TPP (9.58 vs. 1.72; p = 0.004) or < 10 km away from HPL (3.90 vs. 3.19; p = 0.045). A positive relation between both factors was observed (Chi-square-for-trend = 9.209; p = 0.006). Conclusions: SIR of AL in BZ is higher than the Spanish average and that of most countries in the world. Residing near TPP or HPL confers a higher risk of AML, with synergistic effect between both factors.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2012, 25, 1; 22-30
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal modeling and RMS current measurement in electrical power lines using IR thermography
Autorzy:
Torzyk, B.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114450.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
RMS electrical current measurement
heat transfer modeling
overhead power lines
IR thermography
Opis:
Thermal modeling in frequency domain and experiments using IR thermography are performed to evaluate RMS current in electrical power lines. The model implements interface thermal resistance between the metal core and insulation layer. This allowed matching the results of simulations and measurements with acceptable accuracy. The proposed method requires the use of known values of heat transfer coefficient and thermal parameters of the cable and its insulation. In consequence the proposed method requires calibration.
Źródło:
Measurement Automation Monitoring; 2018, 64, 3; 53-56
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza rozkładu pola elektromagnetycznego pod linią elektroenergetyczną w rzeczywistych warunkach terenowych wolna od błędów wnoszonych przez wahania prądów
Analysis of the Distribution of the Magnetic Component of Electromagnetic Fields Under Power Lines in the Real Field Conditions Free from the Error Brought by Fluctuations of Currents
Autorzy:
Wróblewski, Z.
Sztafrowski, D.
Gumiela, J.
Powiązania:
https://bibliotekanauki.pl/articles/158743.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
pole elektromagnetyczne
linie elektroenergetyczne
symulacje cyfrowe
electromagnetic fields
power lines
digital simulation
Opis:
W artykule przedstawiono nową metodę pomiaru rozkładu pola elektromagnetycznego pod liniami elektroenergetycznymi, która jest wolna od błędu wnoszonego przez wahania napięć, prądów i/lub odchyłki symetrii faz układu wielofazowego. W artykule przeanalizowano powyższe problemy dla wybranej linii 110 kV.
The paper presents a new method for the measuring of the electromagnetic field distribution under power transmission lines in real field conditions. This method is free from errors brought by fluctuations of voltage, current and / or deviation of symmetry of phases of the multiphase system. The article analyzes these problems for a selected line of 110 kV.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 272; 179-188
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostic Symptoms of Corona Audible Noise in Continuous Monitoring Systems
Autorzy:
Wszołek, T.
Powiązania:
https://bibliotekanauki.pl/articles/177366.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
corona audible noise
power lines
continuous monitoring systems
noise indicators
statistical levels
Opis:
Random nature of corona processes in UHV power lines and the accompanying noise is the reason that in practice the best determination of acoustic parameters, necessary for the noise evaluation, is obtained from the continuous monitoring procedure. However because of considerable fluctuations (both the useful signal part and the interfering components), careful selection of monitored parameters is necessary to enable a possibility of automatic determination of the parameters that are required for long-term evaluation of corona noise. In the present work a practical realization is shown for estimation of corona noise parameters, based on the data obtained from continuous monitoring stations, making use of the statistical spectra measurement and characteristic features of corona process acoustic signal. Selected results are presented from continuous monitoring of corona noise generated at a 400 kV power line, with special attention focused on definitions of the measured quantities, which enable automatic estimation of the basic factors required for noise evaluation. Accompanying monitoring of environmental conditions, including humidity, precipitation intensity and fog density, that are well correlated with the corona process intensity, which might definitely increase the filtration efficiency of environmental disturbances and on the other hand, it enables verification of calculation methods applied to corona noise. The paper also contains a description of practical approach to selection signal parameters of corona noise in continuous monitoring stations.
Źródło:
Archives of Acoustics; 2011, 36, 1; 151-160
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Feasibility of Locating 110 kV Line in 400 kV Right-of-way in Terms of Electromagnetic Interaction
Analiza możliwości lokalizacji linii 110 kV w pasie technologicznym linii 400 kV w aspekcie oddziaływań elektromagnetycznych
Autorzy:
Nowak, W.
Tarko, R.
Powiązania:
https://bibliotekanauki.pl/articles/397517.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
overhead power lines
electromagnetic interaction
designing
napowietrzne linie elektroenergetyczne
oddziaływanie elektromagnetyczne
projektowanie
Opis:
In this paper an analysis of the feasibility of locating a 110 kV line in a 400 kV line right-of-way in terms of electromagnetic interaction is presented. The analysis was performed in a model system with the use of the EMTP-ATP simulation program. Construction conditions of the 110 kV line and its subsequent operation were considered. Normal operation conditions and short-circuit in 400 kV line were taken into account. The paper presents the results of the calculation of the prospective touch voltages and touch currents in the 110 kV line.
Przedmiotem artykułu jest analiza możliwości lokalizacji linii 110 kV w pasie technologicznym linii 400 kV w aspekcie oddziaływań elektromagnetycznych. Analizę przeprowadzono w układzie modelowym z wykorzystaniem programu symulacyjnego EMTP-ATP. Rozważono zarówno warunki budowy linii 110 kV, jak i jej późniejszej eksploatacji w stanie pracy normalnej oraz zwarć w linii 400 kV. Wyznaczono spodziewane w tych warunkach w linii 110 kV napięcia dotykowe i prądy rażeniowe.
Źródło:
Acta Energetica; 2013, 1; 102-113
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodology of Determining Scope of Executability of Right of Transmission Easement for Overhead Power Lines
Metodyka określania zakresu wykonywalności prawa służebności przesyłu dla napowietrznych linii elektroenergetycznych
Autorzy:
Sajnóg, N.
Sobolewska-Mikulska, K.
Powiązania:
https://bibliotekanauki.pl/articles/386064.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
służebność przesyłu
urządzenia przesyłowe
linie elektroenergetyczne
transmission easement
transmission devices
power lines
Opis:
Służebność przesyłu, jako podstawowy tytuł prawny pozyskiwany przez przedsiębiorców, umożliwia budowę oraz późniejszą eksploatację urządzeń przesyłowych w przestrzeni cudzej nieruchomości. Pozwala również na regulację tzw. zaszłości, czyli sytuacji, gdy urządzenia zostały wybudowane bez posiadanego tytułu prawnego do gruntu. Wykonywanie służebności przesyłu powinno się odbywać w niezbędnym do tego zakresie. Metodyczne i precyzyjne wyznaczenie jej zasięgu jest więc niezwykle istotne, gdyż przekłada się na ograniczenie konstytucyjnie chronionego prawa własności. Zakres wykonywalności przedmiotowego prawa, tzw. powierzchnia służebności przesyłu, ma z kolei wpływ na wysokość rekompensat przysługujących właścicielowi nieruchomości obciążonej, rozumianych jako odszkodowania za szkody związane z budową i istnieniem urządzeń przesyłowych w przestrzeni cudzych nieruchomości oraz wynagrodzenia za ustanowienie samego prawa. Celem artykułu jest opracowanie metodyki określania zakresu wykonywalności prawa służebności przesyłu na przykładzie napowietrznych linii elektroenergetycznych.
Transmission easement as the basic legal title obtained by entrepreneurs permits the construction and later exploitation of transmission devices in the space of another person’s land property. It also allows for the regulation of unfavorable circumstances; i.e., situations where the devices were constructed without a held legal title to the land. The execution of transmission easement should be implemented in the necessary scope. The methodical and precise determination of its range, therefore, is important, because it also translates into a limitation of the constitutionally-protected ownership right. The scope of executability of the said right (the so-called “area of transmission easement”) in turn affects the amount of compensation payable to the owner of the encumbered land property, defined as compensation for any damage related to the construction and existence of transmission devices in the space of another person’s land property and remuneration for the establishment of the right itself. The objective of the article is to develop a methodology of determining the scope of executability of the right of a transmission easement based on the example of overhead power lines.
Źródło:
Geomatics and Environmental Engineering; 2018, 12, 1; 121-135
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości lokalizacji linii 110 kV w pasie technologicznym linii 400 kV w aspekcie oddziaływań elektromagnetycznych
Analysis of possibility of 110 kv line location in a 400 kv line technology strip in terms of electromagnetic interaction
Autorzy:
Nowak, W.
Tarko, R.
Powiązania:
https://bibliotekanauki.pl/articles/266538.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
napowietrzne linie elektroenergetyczne
oddziaływanie elektromagnetyczne
projektowanie
overhead power lines
electromagnetic interaction
designing
Opis:
Artykuł dotyczy analizy możliwości lokalizacji linii 110 kV w pasie technologicznym linii 400 kV w aspekcie oddziaływań elektromagnetycznych. Analizę przeprowadzono w układzie modelowym z wykorzystaniem programu symulacyjnego EMTP-ATP. Rozważono zarówno warunki budowy linii 110 kV, jak i jej późniejszej eksploatacji, w stanie pracy normalnej oraz zwarć w linii 400 kV. Wyznaczono spodziewane w tych warunkach w linii 110 kV napięcia dotykowe i prądy rażeniowe.
In this paper the analysis of possibility of 110 kV line location in a 400 kV line technology strip in terms of electromagnetic interaction is presented. The analysis was performed in a model system with the usage of the simulation program EMTP-ATP. Construction conditions of the 110 kV line and its subsequent operation were considered. Normal operation conditions and short-circuit in 400 kV line were taken into account. The paper presents the results of the calculation of the prospective touch voltages and touch currents in the 110 kV line.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 19-22
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal Method for Polarization Selection of Stationary Objects Against the Background of the Earth’s Surface
Autorzy:
Volosyuk, Valerii
Zhyla, Simeon
Pavlikov, Vladimir
Ruzhentsev, Nikolay
Tserne, Eduard
Popov, Anatoliy
Shmatko, Oleksandr
Dergachov, Kostiantyn
Havrylenko, Olena
Ostroumov, Ivan
Kuzmenko, Nataliia
Sushchenko, Olga
Averyanova, Yuliya
Zaliskyi, Maksym
Solomentsev, Oleksandr
Kuznetsov, Borys
Nikitina, Tatyana
Powiązania:
https://bibliotekanauki.pl/articles/2055248.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
polarimetric radar
polarization selection
power lines detection
multichannel processing
maximum likelihood method
Opis:
Within the maximum likelihood method an optimal algorithm for polarization target selection against the background of interfering signal reflected from the earth’s surface is synthesized. The algorithm contains joint operations of spectral interference rejection and their polarization compensation by means of certain combinations of interchannel subtraction of signals of different polarizations. The physical features of the elements of the polarization scattering matrix are investigated for the technical implementation of the synthesized algorithm.
Źródło:
International Journal of Electronics and Telecommunications; 2022, 68, 1; 83--89
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies