Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power inverter" wg kryterium: Temat


Tytuł:
GaN-based soft-switched active power buffer operating at ZCS – problems of start-up and shut-down
Autorzy:
Rąbkowski, J.
Król, K.
Zdanowski, M.
Sochacki, M.
Powiązania:
https://bibliotekanauki.pl/articles/201868.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
GaN
power inverter
active buffer
Opis:
This paper describes practical issues related to control of the active power buffer (APB) developed for a 2 kVA single-phase inverter. The buffer is designed using the latest GaN HEMTs controlled with triangular current mode to reduce switching losses, however, the switching frequency should be limited to 1 MHz. In the case of the presented analogue-digital controller, frequency is influenced by a reference current of the APB and circuit. Therefore, the operation at start-up and shut-down is especially challenging. A modified control algorithm that also includes pre-charging and discharging process of the energy buffer is presented and experimentally verified by series of tests of the 2 kVA GaN based inverter with the APB.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 785-792
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control system in electric tricycle focused on high dynamics of pedals load torque response
Autorzy:
Fabiański, B.
Wicher, B.
Powiązania:
https://bibliotekanauki.pl/articles/377624.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electric vehicle
tricycle
distributed control system
pedaling by wire system
CAN network
electric drive
BLDC motor
power inverter
STM32F4 MCU
Opis:
In the article two different control system structures of electric driven tricycle are presented. The very specific feature of the vehicle is that it works with "pedaling by wire". It means, that there is no mechanical coupling between pedals and any of driven wheels. This structure gives an advantage of achieving wide range of the correlation between the pedals load torque and speed and the driven wheels electromagnetic torque and speed. The challenge is to provide a natural pedaling feels for the rider. Two different approaches for control system signal flow are compared for natural pedaling feel for cyclist. The system architecture bases on CAN network distributed control that links three independent wheel drives, dedicated HMI panel, generator inverter and centralized supervisory board. The modelling methods are presented in the paper with an appropriate analytical base. Simulation results of presented control structures follows experimental ones taken from the electric tricycle.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 85; 233-244
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of space vector modulation strategy on hybrid (Si-SiC) inverter losses
Autorzy:
Bonisławski, M.
Hołub, M.
Powiązania:
https://bibliotekanauki.pl/articles/140592.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik hybrydowy
elektronika energetyczna
urządzenie z szeroką przerwą energetyczną
SVPWM
DPWM
power electronic inverter
SiC diodes
hybrid inverter
wide band gap devices
Opis:
This work summarizes efficiency measurement results of a full bridge, 3 phase inverter composed of state-of-the-art Si IGBT transistors and Si or SiC diodes. Different (symmetrical and discontinuous) space vector modulation strategies were chosen in order to examine their influence (together with modulation frequency) on inverter losses. Induction machine was used as load, different load points were examined. Results clearly show, that proper modulation strategy, minimizing the switching losses of semiconductor switches, can increase the overall output efficiency at about 1% in case of both silicon and hybrid constructions. The drawback of DPWM approach is connected with the decreased quality of inverter output current. Hybrid technology can also improve the output efficiency at about 1% when compared to traditional constructions, but only in case of elevated switching frequencies. At low frequencies (below 10 kHz) modern semiconductor offer comparable results at much lower device costs.
Źródło:
Archives of Electrical Engineering; 2012, 61, 1; 69-75
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part II
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114230.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 325-328
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part I
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114413.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 322-324
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulacja wydajności urządzeń potrzeb własnych elektrowni cieplnych asynchronicznymi napędami falownikowymi średniego napięcia
Variable speed drives with frequency converters in thermal power plant auxiliaries
Autorzy:
Wawszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/173004.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia cieplna
napęd falownikowy
przemiennik
thermal power station
inverter drive
inverter
Opis:
Omówiono możliwości regulacji wydajności urządzeń potrzeb własnych elektrowni cieplnych napędzanych klatkowymi silnikami indukcyjnymi zasilanymi przemiennikami częstotliwości. Skupiono się głównie na napędach średnionapięciowych (6÷10 kV) dużej mocy. Przedstawiono aktualną ofertę przemienników czołowych światowych producentów. Oceniono możliwości wykorzystania tego typu napędów w dużych, nowoczesnych elektrowniach blokowych.
The paper introduces current potential of variable speed drives (VSD) intended for squirrel cage induction motors supplied by frequency converters in thermal power plant auxiliaries. The paper is mostly focused on medium-voltage (6-10 kV) and high-power drives. Current tender of leading world producers in this field has been presented. Possibility to apply this type of drives in large, modern block-power plants has been considered.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 87-99
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Z-source converter in photovoltaic grid-connected transformer-less inverter
Autorzy:
Farhangi, B.
Farhangi, S.
Powiązania:
https://bibliotekanauki.pl/articles/262715.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
photovoltaic power conditioner (PV PCU)
gird-connected systems
Z-source inverter
inverter
Opis:
In PV grid connected power conditioners, usually both stepping-up the PV array voltage, and stepping-down the dc bus voltage for injection of a sinusoidal current to the grid is required. In this paper the design procedure of Z-source converter as a single phase PV grid connected transformer-less inverter is presented. The converter has one switch less than the conventional two stage power conditioner, which leads to reduction of cost. An optimum modulation pattern for the switches is proposed, and the low frequency ripple of the converter is modeled. The design of the converter is verified by simulation.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 41-45
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalne sterowanie falownika przy jego pracy na sieć systemu energetycznego
Optimal inverter controling during its operation for power grid
Autorzy:
Mazur, D.
Powiązania:
https://bibliotekanauki.pl/articles/1369606.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
optymalne sterowanie
system energetyczny
optimal inverter
power grid
Opis:
The inverter circuit is supposed to operate for grid with low internal impedance (for fixed grid). The goal of the presented circuit is to provide the given current of the main harmonic to the grid. The grid can contain higher harmonics of the voltage, which due to the low impedance of the grid lines spreads to the voltage of the inverter output. Therefore we need to calculate the first (main) harmonic of this voltage and find such inverter controlling, that the main harmonic of the current flowing to the grid from the considered circuit would be in the given angle position to it and at the given value. The second important goal of the circuit is, as far as possible, to eliminate the voltage higher harmonics at the circuit output getting there from the grid. Obviously eliminating the ripples from voltage higher harmonics of the receiver is limited by the capabilities of the examined inverter circuit.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 2, 95; 25-30
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intermittent power smoothing control for grid connected hybrid wind/PV system using battery-EDLC storage devices
Autorzy:
Jayalakshmi, N.S.
Gaonkar, D.N.
Karthik, R.P.
Prasanna, P.
Powiązania:
https://bibliotekanauki.pl/articles/141664.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energy storage devices
inverter controller
MPPT controller
power smoothing
PV system
wind power
Opis:
Wind and solar radiation are intermittent with stochastic fluctuations, which can influence the stability of operation of the hybrid system in the grid integrated mode of operation. In this research work, a smoothing control method for mitigating output power variations for a grid integrated wind/PV hybrid system using a battery and electric double layer capacitor (EDLC) is investigated. The power fluctuations of the hybrid system are absorbed by a battery and EDLC during wide variations in power generated from the solar and wind system, subsequently, the power supplied to the grid is smoothened. This makes higher penetration and incorporation of renewable energy resources to the utility system possible. The control strategy of the inverter is realized to inject the power to the utility system with the unity power factor and a constant DC bus voltage. Both photovoltaic (PV) and wind systems are controlled for extracting maximum output power. In order to observe the performance of the hybrid system under practical situations in smoothing the output power fluctuations, one-day practical site wind velocity and irradiation data are considered. The dynamic modeling and effectiveness of this control method are verified in the MATLAB/Simulink environment. The simulation results show that the output power variations of the hybrid wind/PV system can be significantly mitigated using the combination of battery and EDLC based storage systems. The power smoothing controller proposed for the hybrid storage devices is advantageous as compared to the control technique which uses either battery or ultracapacitor used for smoothing the fluctuating power.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 433-453
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A closed-loop power controller model of series-resonant-inverter-fitted induction heating system
Autorzy:
Pal, P.
Roy, D.
Datta, A.
Sadhu, P. K.
Banerjee, A.
Powiązania:
https://bibliotekanauki.pl/articles/141721.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction heating
power controller
PID
series resonant inverter
MATLAB
Opis:
This paper presents a mathematical model of a power controller for a high-frequency induction heating system based on a modified half-bridge series resonant inverter. The output real power is precise over the heating coil, and this real power is processed as a feedback signal that contends a closed-loop topology with a proportional-integral-derivative controller. This technique enables both control of the closed-loop power and determination of the stability of the high-frequency inverter. Unlike the topologies of existing power controllers, the proposed topology enables direct control of the real power of the high-frequency inverter.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 827-841
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca układu napędowego drzwi kabinowych z silnikiem synchronicznym przy zasilaniu awaryjnym
Cabin Door Drive System with Synchronous Motor Powered by Emergency Battery
Autorzy:
Kolano, K.
Powiązania:
https://bibliotekanauki.pl/articles/1368558.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny
zasilanie awaryjne
przekształtnik
synchronous motor
emergency power
inverter
Opis:
The article presents the basic assumptions of technical operation of the propulsion system of a passenger elevator cabin door powered by emergency battery. It is highly reccomended for electric driver system of the lift doors, to open and close several times when supplying by the emergency battery. It is necessary to develop a control algorithm of synchronous motor operation to provide proper operation of the system performance at lower power. The developed procedure has been tested in the laboratory of the Department of Electrical Machines and Drives, and will be implemented into industrial practice in the New cabin door drive system.
W artykule przedstawione zostały podstawowe założenia techniczne pracy układu napędowego drzwi kabinowych dźwigu osobowego przy zasilaniu ze źródła rezerwowego. Podstawowym wymogiem jest umożliwienie otwarcia drzwi dźwigu po wykonaniu zjazdu awaryjnego z możliwie jak najmniejszą mocą przy wykorzystaniu tylko jednego akumulatora rezerwowego. Aby umożliwić poprawną pracę układu przy obniżonych parametrach zasilania konieczne jest opracowanie specjalnego algorytmu sterowania uwzględniającego charakterystykę pracy silnika synchronicznego. Opracowana procedura została przetestowana w laboratorium Katedry Napędów i Maszyn Elektrycznych i zostanie wdrożona do praktyki przemysłowej w nowym układzie napędowym drzwi kabinowych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 251-254
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new circuit topology using Z-source resonant inverter for high power contactless power transfer applications
Autorzy:
Ghosh, P. C.
Sadhu, P. K.
Ghosh, A.
Pal, N.
Powiązania:
https://bibliotekanauki.pl/articles/141006.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
contactless power transfer
mutual inductance
magnetic coupling coefficient
Z-source
resonant inverter
Opis:
In this study, a new circuit topology using a Z-source resonant inverter (ZSRI) for high power applications in large-air-gap contactless power transfer (CPT) systems, has been investigated. The main shortcoming of a large-air-gap CPT system is the poor power transfer efficiency due to low magnetic coupling. In order to minimize this shortcoming and to improve the overall performance of the system by boosting the power transfer capability, in this paper a CPT system with the newly developed circuit topology using high frequency Z-source resonant inverter has been proposed. Using the newly developed circuit topology for the CPT system, it has been observed that the overall performance of the system has been improved to a reasonable level with a purely sinusoidal resonant current flowing through the primary side. Therefore, no harmonics will be injected into the source. The proposed CPT system with an air gap of 16 cm and a misalignment of 3 cm has been simulated using the Maxwell finite element tool and Simplorer circuit simulation software for an output power of 2 kW.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 843-854
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model predictive direct power control of energy storage quasi-Z-source grid-connected inverter
Autorzy:
Tang, Min'an
Yang, Shangmei
Zhang, Kaiyue
Wang, Qianqian
Liu, Chenggang
Dong, Xuewang
Powiązania:
https://bibliotekanauki.pl/articles/2042769.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
quasi Z-Source
inverter
energy storage
power control
model predictive
space vector
Opis:
In order to overcome the shortcoming of large switching losses caused by variable switching frequency appears in the conventional finite control set model predictive control (FCS-MPC) algorithm, a model predictive direct power control (MP-DPC) for an energy storage quasi-Z-source inverter (ES-qZSI) is proposed. Firstly, the power prediction model of the ES-qZSI is established based on the instantaneous power theory. Then the average voltage vector in the coordinate system is optimized by the power cost function. Finally, the average voltage vector is used as the modulation signal, and the corresponding switching signal with fixed frequency is generated by the shoot-through segment space vector pulse width modulation (SVPWM) technology. The simulation results show that the ES-qZSI realizes six shoot-through actions per control cycle and achieves the constant frequency control of the system, which verifies the correctness of the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2022, 71, 1; 21-35
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cyfrowy automat sterujący urządzeń energoelektronicznych z wykorzystaniem modelu czasu rzeczywistego falownika
Digital state machine of power electronic device with the use of inverter’s real-time model
Autorzy:
BINKOWSKI, Tomasz
KWIATKOWSKI, Bogdan
Powiązania:
https://bibliotekanauki.pl/articles/456633.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Rzeszowski
Tematy:
model czasu rzeczywistego
energoelektronika
falownik
sterowanie
real-time model
power electronic
inverter
control
Opis:
Artykuł przedstawia koncepcję stanowiska laboratoryjnego przeznaczonego do badań układów sterowania przekształtników energoelektronicznych. Zakłada się, że przekształtnik energoelektroniczny symulowany jest sprzętowo jako współbieżny proces w stosunku do testowanego układu sterowania. Jako platformę sprzętową wykorzystuje się układ o programowalnej strukturze logicznej umożliwiający testowanie procesu sterowania na modelu czasu rzeczywistego przekształtnika lub bezpośrednie sterowanie modelem laboratoryjnym. Jako przykład przedstawiono cyfrowy model falownika napięcia sterowany automatem realizującym przełączanie półokresowe. Prezentowana koncepcja ma zastosowanie w badaniach naukowych i dydaktyce.
The article presents the concept of the laboratory stand for testing of power electronic control systems. It is assumed that the converter unit and the control process are simulated in parallel as a hardware. The hardware platform uses the programmable logical structure for testing the control process on real time inverter model or can directly control the laboratory inverter model. The digital model of the inverter voltage controlled by digital state machine that makes half-period switching was used as an example. The presented concept is applicable in scientific research and teaching.
Źródło:
Edukacja-Technika-Informatyka; 2016, 7, 4; 387-393
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency comparison between the LLCL and LCL-filters based single-phase grid-tied inverters
Autorzy:
Wu, W.
Huang, M.
Blaabjerg, F.
Powiązania:
https://bibliotekanauki.pl/articles/140537.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCL filter
LLCL-filter
efficiency power loss
modulation
single-phase grid-tied inverter
Opis:
An LLCL-filter is becoming more attractive than an LCL-filter as the interface between the grid-tied inverter and the grid due to possibility of reducing the copper and the magnetic materials. The efficiency of the LLCL-filter based single-phase grid-tied inverter also excites interests for many applications. The operation of the switches of the VSI is various with different modulation methods, which lead to different efficiencies for such a single-phase grid-tied inverter system, and therefore important research has been carried out on the effect of the choice of PWM schemes. Then power losses and efficiencies of the LLCL-filter and the LCL-filter based single-phase grid-tied inverters are analyzed and compared under the discontinuous unipolar, the dual-buck and the bipolar modulations. Results show that the efficiency of LLCL-filter based inverter system is higher than the LCL- filter based independent on the modulation method adopted. Experiments on a 2 kW prototype are in good agreement with results of the theoretical analysis.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 63-79
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies