Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "membrany ultrafiltracyjne" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Analiza zjawiska blokowania membran ultrafiltracyjnych w procesie oczyszczania wód
Analyzing the phenomenon of membrane fouling in the course of water treatment by ultafiltration
Autorzy:
Kabsch-Korbutowicz, M.
Majewska-Nowak, K.
Powiązania:
https://bibliotekanauki.pl/articles/237283.pdf
Data publikacji:
1998
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
membrany ultrafiltracyjne
proces oczyszczania wód
Opis:
The drop in the permeate flux during ultrafiltration of agueous solutions containing organic macromolecules was studied,and the intensity of fouling was related to the hydrophilic/hydrophobic properties of the membrane,as well as to the parameters (pH and Ca2+ ion concentration ) of the investigated water.In this study,use was made of strongly hydrophilic ( cellulose acetate) and stongly hydrophobic ( polysulfone or polyamide ) membranes. Thus,the stongly hydrophilic membranes were found to be less prone to fouling produced by the sorption of organic macromolecules,wherewesthe strongly hydrophobic membranes suffered from a consideable drop in pereability,which was associated with their grather proneness to fouling.The presence of mineral salts intensifying the phenomenon of membrane fouling,and reducing permeate flux.
Źródło:
Ochrona Środowiska; 1998, 4; 11-15
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafiltration as a method of natural organic matter separation from water
Ultrafiltracja jako metoda usuwania naturalnych substancji organicznych z wody
Autorzy:
Kabsch-Korbutowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1825951.pdf
Data publikacji:
2008
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ultrafiltracja
oczyszczanie wody
uzdatnianie wody
membrany ultrafiltracyjne
wydajność hydrauliczna membran
Opis:
Pogarszająca się jakość wód oraz rosnące wymagania stawiane wodzie przeznaczonej do spożycia przez ludzi powodują konieczność stosowania nowoczesnych procesów technologicznych ich uzdatniania. Taką techniką jest ultrafiltracja, proces membranowy pozwalający na usunięcie bardzo szerokiego spektrum zanieczyszczeń: zarówno mikroorganizmów jak i makrocząsteczek o wielkości 1 -100 nm. Do tej grupy zanieczyszczeń należą naturalne substancje organiczne, które zarówno niekorzystnie wpływają na jakość wody jak i na wydajność hydrauliczną membran poprzez ich blokowanie (fouling). O skuteczności usuwania naturalnych substancji organicznych z wody w procesie ultrafiltracji oraz podatności membran na blokowanie decyduje bardzo wiele czynników związanych zarówno z właściwościami membran jak i składem oczyszczanej wody. Celem przeprowadzonych badań było określenie wpływu właściwości membran ultrafiltracyjnych; tj. ich granicznej masy molowej (cut-off) oraz polimeru z którego wykonane zostały membrany, jak również właściwości roztworu poddawanego oczyszczeniu na zmianę skuteczności oczyszczania wody, wydajność hydrauliczną membran oraz ich podatność na blokowanie. W badaniach zastosowano membrany ultrafiltracyjne firmy Nadir wykonane z regenerowanej celulozy oraz polieterosulfonu o cut-off 5 - 100 kDa. Testy przeprowadzone zostały dla roztworów modelowych oraz dla wody z rzeki Odry. Przeprowadzone badania wykazały, iż dla wszystkich testowanych membran wzrost wartości ich granicznej masy molowej skutkował wzrostem wydajności hydraulicznej membran. Wykazano też, że zastosowanie membran o większych wymiarach porów skutkuje spadkiem skuteczności usuwania makrocząsteczek organicznych. Zaobserwowano, że charakter hydrofilowo/hydrofobowy polimeru membranotwórczego istotnie wpływał na intensywność blokowania membran. Większy spadek przepuszczalności hydraulicznej membran stwierdzono w przypadku użycia silniej hydrofobowych membran z polieterosulfonu. Analiza uzyskanych wyników badań pozwoliła także wykazać, że wzrost wartości cut-off membran skutkował silniejszym ich blokowaniem, będącym rezultatem zatykania porów membrany.
Źródło:
Rocznik Ochrona Środowiska; 2008, Tom 10; 17-27
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie polimerowych membran ultrafiltracyjnych do usuwania substancji powierzchniowo czynnych z roztworów wodnych
Separation of surface active agents from water solutions using polymer ultrafiltration membranes
Autorzy:
Kowalska, I.
Powiązania:
https://bibliotekanauki.pl/articles/1825969.pdf
Data publikacji:
2008
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
związki powierzchniowo czynne
membrany ultrafiltracyjne
surfaktanty
SPC
dodecylobenzenosulfonian sodu
SDBS
membrany płaskie
Opis:
Celem przeprowadzonych badań było określenie skuteczności polimerowych membran ultrafiltracyjnych w usuwaniu substancji powierzchniowo czynnych z roztworów wodnych w zakresie stężeń poniżej i powyżej krytycznego stężenia micelizacji. Zbadano również wpływ obecności soli mineralnych będących podstawowym wypełniaczem kompozycji detergentowych na skuteczność eliminacji SPC z roztworów wodnych w procesie ultrafiltracji.
Surface active agents, also called surfactants, are amphiphilic compounds that contain both a hydrophobic and a hydrophilic portion. In aqueous solutions, surfactant monomers aggregate into structures called micelles with hydrophobic groups in the interior of the micellar structures. The minimum concentration at which micellization occurs is called the critical micelle concentration (CMC). At higher concentrations than CMC, monomers and micelles coexist in equilibrium. Surface active agents are used in large quantities in household products, detergent formulations, industrial application and as additives to improve the effectiveness of agrochemicals. The consumption of surfactants for both industrial and domestic purpose has resulted in a worldwide production of approximately 17 million tonnes in 2000 (including soap), with expected future growth rates of 3-4% per year globally and of 1.5-2.0% in the EU [19]. As a consequence of their widespread use surfactants may persist in wastewater treatment systems at relatively high concentrations [13, 18]. In order to meet legislative requirements and to discharge effluents into communal systems or directly into the river an efficient treatment process must be applied. Due to the diversity of surfactants and their physico-chemical properties it is difficult to develop a single and an effective treatment method of detergent wastewater. From among techniques which were studied in this research area [3, 5, 10, 14, 16] can be listed biodegradation, coagulation, foaming, oxidation, adsorption, ion-exchange and membrane processes. Numerous reports indicate that membrane technology is emerging as one of the leading contenders in the recovery of water and concentrated products from the rinsing waters used in the batch production of surfactants and detergents or as a polishing step before the effluents are discharged. The aim of the study was to evaluate the removal efficiency of anionic surfactant from water solutions by means of ultrafiltration. Polymer membranes made of polyethersulfone and cellulose with molecular weight cut-off of 5, 10 and 30 kDa were used. Both transport and separation properties of the polymers were tested for surfactant solutions in concentration range of 0.1-3.0 CMC in a presence of mineral salt (NaCl). It was found that the surfactant concentration was a crucial parameter determining effectiveness of ultrafiltration process. With the increase in surfactant concentration, the retention coefficients and hydraulic performance decreased, with a rise around the CMC value. The UP005 membrane was found to be very effective in anionic surfactant removal in a wide range of concentrations - the retention coefficient amounted to 82-90%. During the permeation experiments in the presence of mineral salt, the increase in retention coefficient was observed for a given dose of mineral salt along with the increase in surfactant concentration in the feed
Źródło:
Rocznik Ochrona Środowiska; 2008, Tom 10; 593-604
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie substancji organicznych z roztworów wodnych z wykorzystaniem ceramicznych membran ultrafiltracyjnych
Removal of organic substances from aqueous solutions with the use of ceramic membrane
Autorzy:
Kabsch-Korbutowicz, M.
Urbanowska, A.
Majewska-Nowak, K.
Kawiecka-Skowron, J.
Powiązania:
https://bibliotekanauki.pl/articles/1819673.pdf
Data publikacji:
2010
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
membrany ultrafiltracyjne
roztwór wodny
substancje organiczne
ultrafiltration membranes
aqueous solution
organic substances
Opis:
Procesy membranowe są obecnie szeroko stosowane w wielu gałęziach przemysłu oraz w szeroko pojętej ochronie środowiska do usuwania różnorodnych zanieczyszczeń zarówno o charakterze organicznym jak i nieorganicznym. W eksploatowanych na całym świecie instalacjach membranowych najczęściej stosowane są membrany wytwarzane z materiałów organicznych, np. polisulfonu, polietersulfonu, poliamidu lub materiałów celulozowych. Powszechność stosowania membran polimerowych wynika przede wszystkim z bardzo dużej dostępności membran o różnorodnych możliwościach separacyjnych. W związku z tym, iż polimery wykorzystywane do produkcji membran nie są odporne na działanie czynników chemicznych, termicznych i biologicznych, od dłuższego czasu trwają prace nad wytwarzaniem membran o znacznie większej wytrzymałości na działanie niekorzystnych czynników. Wymogi te spełniają membrany nieorganiczne wytwarzane z materiałów ceramicznych.
Membrane processes are now widely used in many industries and in the widely understood environment protection to remove the various pollutants of both organic and inorganic character. In the operated worldwide membrane installations membranes made from organic materials such as polysulphone, polietersulphone, polyamide or cellulosic materials are most commonly used. The universality of application of polymer membranes is primarily attributed to very high availability of membranes with various separational characteristics. In view of the fact that the polymers used for production of membranes are not resistant to chemical, thermal and biological factors, works in order to produce membranes with a much higher resistance to the action of unfavourable factors have been carried out for a long time. These requirements meets the inorganic membrane made from ceramic materials. The advantages of ceramic membranes, deciding about their their advantage over organic membranes, include primarily their high thermal, chemical, mechanical and biological resistance. Not without significance is the fact that they can be sterilized with steam and cleaned using strong acids or bases, which allows long-term operation of such membranes. The usability of the ultrafiltration ceramic membrane in removal of natural and synthetic organic pollutants from aqueous solutions has been evaluated. The ultrafdtration experiments have been carried out towards Odra river water, model solution containing NOM and model solutions of organic dyes (methyl orange, indigo carmine, hellion blue, direct black). The ultrafiltration ceramic membrane (cut-off 50kDa) made by Tami Industries and laboratory installation ProFlux Ml2 Millipore were applied in the tests. This installation allows to run separation tests in flow system using a filtration modules of any configuration. Installation enables circulation of the solution between the supply tank with a capacity of 3 dm3 and a filter module.The influence of the transmembrane pressure (0.03,0.06, and 0.09 MPa) on the process efficiency was determined. It was stated that the increase of the applied pressure caused the increase of permeate flux. In the course of ultrafiltration of solutions containing organic substances the determined membrane permeability was much lower (by 10-40%) than observed for water. The separation properties were influenced by the composition of the treated solution and the nature of the organic pollutants. The organic dyes of the molecular weight higher than 900 Da were retained in more than 95%. The reduction of color for solutions containing NOM amounted to 46-65%.
Źródło:
Rocznik Ochrona Środowiska; 2010, Tom 12; 467-478
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kwasy halogenooctowe - usuwanie w bioreaktorze z poliamidową, enzymatyczną membraną ultrafiltracyjną
Haloacetic acids - the removal from water in bioreactor with polyamide enzymatic ultrafiltration membran
Autorzy:
Kowalska, M.
Dudziak, M.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/126201.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
kwasy halogenooctowe
immobilizacja
biodegradacja
enzymatyczne membrany ultrafiltracyjne
halogenacetic acids
immobilization
biodegradation
ultrafiltration enzymatic membranes
Opis:
W pracy przedstawiono wyniki badań nad usuwaniem mieszaniny kwasów halogenooctowych z wody, w procesie ultrafiltracyjnej biodegradacji. Badania prowadzono w reaktorze z płaską poliamidową membraną ultrafiltracyjną, na powierzchni której unieruchomiono enzymy rozkładające HAA. Nadawę w procesie biodegradacji stanowił wodny roztwór mieszaniny pięciu HAA (MCAA, DCAA, TCAA, MBAA, DBAA) o stężeniu 1 mg/dm3 każdego z nich. Unieruchamiane na powierzchni membran enzymy były izolowane metodą Hagemana ze szczepów bakterii wyodrębnionych z mieszanej populacji osadu czynnego, adaptowanego do rozkładu HAA. Dominującymi w populacji rodzajami bakterii były: Acinetobacter, Arthobacter, Pseudomonas oraz Bacillius. Badania prowadzone były przy użyciu reaktora o pojemności 500 cm3, zaopatrzonego w mieszadło magnetyczne, pozwalającego na pracę z membraną o powierzchni 50 cm2. Ich celem było wyznaczenie optymalnych warunków prowadzenia procesu ultrafiltracyjnej biodegradacji kwasów halogenooctowych (ciśnienie transmembranowe, liniowa prędkość przepływu, czas prowadzenia procesu) oraz dopracowanie metodyki oznaczania stężenia usuwanych ksenobiotyków metodą HPLC z wykorzystaniem ekstrakcji HAA w eterze tert-butyloetylowym. Optymalnym ciśnieniem okazało się p = 0,1 MPa i liniowa prędkość przepływu - 0,5 m/s. Przy ich zastosowaniu wydajność procesu membranowego i efektywność usuwania HAA były największe. Po 3,5-godzinnym prowadzeniu procesu w takich warunkach z wody modelowej usunięto całkowicie kwas dichlorooctowy i monobromooctowy, a po 4,5 godzinie pozostałe kwasy. Monitorowano również wydajność procesu - objętościowy strumień permeatu nie zmieniał się w czasie.
The results of the study focused on the removal of halogenated acetic acids (HAA) from water by means of the hybrid process ultrafiltration-biodegration are presented in the article. The study was carried out in the reactor equipped with the ultrafiltration membrane, on the surface of which enzymes responsible for degradation of HAA were immobilized. The feed solution introduced to the process comprised of the mixture of five HAA (MCAA, DCAA, TCAA, MBAA, DBAA) of concentration 1 mg/dm3 each. Enzymes immobilized on the support were isolated according to Hageman method from bacteria separated from activated sludge adapted for HAA degradation. Acinetobacter, Arthobacter, Pseudomonas and Bacillius were dominant types of microorganisms. The study was carried out in reactor of volume 500 cm3 equipped with magnetic stirrer and the flat membrane of area 50 cm2. The aim of the experiment was to determine the optimal conditions for the hybrid process ultrafiltration-biodegradation of HAA (transmembrane pressure, linear feed flow rate, length of the process). Additionally, the method of analysis of degraded xenobiotics concentration using HPLC and HAA extraction with ETBE was developed. Obtained results allowed to assign the optimal operating conditions of the hybrid ultrafiltration-biodegradation system ie transmembrane pressure 0.1 MPa and linear feed flow rate 0.5 m/s. The highest membrane process capacity and HAA removal effectiveness were obtained under those conditions. The total removal of dichloroacetic acid and monobromoacetic acid lasted 3.5 h and 4.5 h for the rest of the investigated acids applying optimal operation parameters. The capacity of the process determined by the measurement of volumetric permeate flux did not change in time.
Źródło:
Proceedings of ECOpole; 2012, 6, 1; 349-355
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biodegradacja kwasów halogenooctowych w bioreaktorze z poliamidową, enzymatyczną membraną ultrafiltracyjną
Biodegradation of halogenated acetic acids by means of bioreactor with polyamide ultrafiltration membrane
Autorzy:
Kowalska, M.
Dudziak, M.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/296905.pdf
Data publikacji:
2011
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
kwasy halogenooctowe
immobilizacja
biodegradacja
enzymatyczne membrany ultrafiltracyjne
halogenacetic acids
immobilization
biodegradation
ultrafiltration enzymatic membranes
Opis:
Przedstawiono uzyskane wyniki badań nad usuwaniem mieszaniny kwasów halogenooctowych z wody w procesie ultrafiltracyjnej biodegradacji. Proces ultrafiltracyjnej biodegradacji, oparty na membranach z unieruchomionymi białkami aktywnymi, przebiega w temperaturze otoczenia, charakteryzuje się niską energochłonnością i niewielkimi kosztami eksploatacyjnymi. Pozwala na obniżenie stężenia substancji toksycznych w miejscu ich powstawania do wartości dopuszczalnych i umożliwia doczyszczanie uzdatnianej wody w procesie ultrafiltracji. Badania prowadzono w reaktorze z membraną ultrafiltracyjną, na powierzchni której unieruchomiono enzymy rozkładające HAA. Jako nośników do immobilizacji używano poliamidowych membran płaskich, modyfikowanych aldehydem glutarowym w celu otrzymania trwałych, kowalencyjnych wiązań pomiędzy materiałem membrany a enzymem. Nadawę w procesie biodegradacji stanowił wodny roztwór mieszaniny pięciu HAA (MCAA, DCAA, TCAA, MBAA, DBAA) o stężeniu 1 mg/dm3 każdego z nich. Unieruchamiane na powierzchni membran enzymy były izolowane metodą Hagemana ze szczepów bakterii wyodrębnionych z mieszanej populacji osadu czynnego, adaptowanego do rozkładu HAA. Dominującymi w populacji rodzajami bakterii były: Acinetobacter, Arthobacter, Pseudomonas oraz Bacillius. Celem badań było wyznaczenie optymalnych warunków prowadzenia procesu ultrafiltracyjnej biodegradacji kwasów halogenooctowych (ciśnienie transmembranowe, intensywność mieszania, czas prowadzenia procesu) oraz opracowanie metodyki oznaczania stężenia usuwanych ksenobiotyków metodą HPLC z wykorzystaniem ekstrakcji HAA w eterze tert-butyloetylowym. Podczas filtracji roztworu kwasów przez membrany enzymatyczne wyznaczano również zależności objętościowego strumienia permeatu od ciśnienia transmembranowego, a w oparciu o obliczone stężenia ksenobiotyków w poszczególnych strumieniach ultrafiltracyjnych określano stopień biodegradacji HAA. Otrzymane wyniki pozwoliły na wyznaczenie najkorzystniejszych parametrów operacyjnych procesu ultrafiltracyjnej biodegradacji kwasów halogenooctowych. Przy ich zastosowaniu wydajność procesu membranowego i efektywność usuwania HAA były najwyższe. Po 3,5-godzinnym prowadzeniu procesu w takich warunkach z wody modelowej usunięto całkowicie kwas monochlorooctowy i monobromooctowy, a po 5 godzinach pozostałe kwasy. Monitorowano również wydajność procesu objętościowy strumień permeatu nie zmieniał się w czasie.
The results of the study focused on the removal of halogenated acetic acids (HAA) from water by means of the hybrid process ultrafiltration-biodegration are presented in the article. The hybrid system based on membranes with immobilized active enzymes is run at room temperature and characterizes with low energy consumption and exploitation costs. It allows to decrease the concentration of toxic substances in place of their formation as well to polish the treated water via ultrafiltration. The study was carried out in the reactor equipped with the ultrafiltration membrane, on the surface of which enzymes responsible for degradation of HAA were immobilized. Polyamide flat membranes modified with glutaric aldehyde in order to obtain stable, covalent bonds between membrane and enzymes were used as the immobilization support. The feed solution introduced to the process comprised of the mixture of five HAA (MCAA, DCAA, TCAA, MBAA, DBAA) of concentration 1 mg/dm3 each. Halogenated acetic acids are byproduct of water disinfection. They are formed during the reaction of HAA precursors (mainly humic substances) with chlorine and its derivatives. The presence of HAA in drinking water is already proved to be harmful for animals and humans. Some HAA were recognized as carcinogens e.g. dichloroacetic acid and trichloroacetic acid. It was also found that dichloroacetic acid caused neuropathy, liver cancer and weight reduction. According to their toxic properties, the systematic control of HAA concentration in drinking water during the treatment process is performed in many countries. Besides, standards concerning the permissible concentration of HAA in drinking water are developed. Enzymes immobilized on the support were isolated according to Hageman method from bacteria separated from activated sludge adapted for HAA degradation. Acinetobacter, Arthobacter, Pseudomonas and Bacillius were dominant types of microorganisms. The study were carried out in S-76-400 reactor (by Nuclepore) of volume 500 cm3 equipped with magnetic stirrer and the flat membrane of area 38.5 cm2. The aim of the experiment was to determine the optimal conditions for the hybrid process ultrafiltration-biodegradation of HAA (transmembrane pressure, intensity of stirring, length of the process). Additionally, the method of analysis of degraded xenobiotics concentration using HPLC and HAA extraction with ETBE was developed. The dependence of volumetric permeate flux on the transmembrane pressure was determined during the filtration of HAA solution. The degree of biodegradation of xenobiotics was evaluated basing on the concentration of HAA in particular process streams. Obtained results allowed to assign the optimal operating conditions of the hybrid ultrafiltrationbiodegradation system i.e. transmembrane pressure 0.1 MPa and stirring speed 75 rpm. The highest membrane process capacity and HAA removal effectiveness were obtained under those conditions. The total removal of monochloroacetic acid and monobromoacetic acid lasted 3.5 and 5 h for the remaining investigated acids applying optimal operation parameters. The capacity of the process determined by the measurement of volumetric permeate flux did not change in time.
Źródło:
Inżynieria i Ochrona Środowiska; 2011, 14, 3; 257-266
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the effluent polishing plant using a ultrafiltration membrane installed at a palm oil mill
Autorzy:
Abdul Hadi, Numan
Hawari, Yahaya
Ngatiman, Muzzammil
Jalani, Nor Faizah
Wahab, Noorshamsiana Abdul
Halim, Rohaya Mohamed
Powiązania:
https://bibliotekanauki.pl/articles/208299.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
BOD
palm oil mill
wastewater treatment
ultrafiltration membranes
BZT
olej palmowy
oczyszczanie ścieków
membrany ultrafiltracyjne
Opis:
Palm oil mills discharge raw effluent with high biochemical oxygen demand (BOD) of about 25 000 mg O2/dm3 . Conventional effluent treatment system uses ponds with a long hydraulic retention time of about 55–85 days, but the reduction of BOD is usually halted at 100–250 mg O2/dm 3. Further reduction of BOD to below 20 mg O2/dm3 to meet regulation requirement needs further advanced treatment. This study evaluates the efficiency of an effluent polishing plant installed at a palm oil mill targeting final effluent BOD below 20 mg O2/dm3. Characteristic of the incoming and treated effluent, dissolved oxygen in the aeration ponds and the effluent flow rate of the treatment plant have been determined. Due to low process throughput at the mill, the polishing plant operated at only 60% of its designed capacity. Treatment of effluent showed reduction of BOD from 39.3±5.8 to 6.1±3.8 mg O2/dm3, i.e., a reduction by 80–94%. Colour – a newly proposed regulation parameter – was reduced from 1081±69 to 845±60 ADMI, i.e., by 11–30%. This study indicates that while the treatment of effluent to reduce the BOD to below 20 O2/dm3 O2/dm3 is feasible, reduction of colour to less than 100 ADMI is not achievable.
Źródło:
Environment Protection Engineering; 2019, 45, 1; 155-170
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Membrany polisulfonowe w oczyszczaniu ścieków koksowniczych
Application of polysulfone membranes for coke-making wastewater treatment
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/126367.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
oczyszczanie ścieków koksowniczych
układy zintegrowane
ciśnieniowe techniki membranowe
polisulfonowe membrany ultrafiltracyjne
cokemaking wastewater treatment
membrane pressure techniques
integrated system
polysulfone membranes
Opis:
Z uwagi na złożony i zmienny skład ścieków koksowniczych strategia ich oczyszczania jest trudna do uogólnienia i wymaga prowadzenia tego procesu w układach zintegrowanych, kojarzących biologiczne i fizykochemiczne procesy jednostkowe. W artykule omówiono badania, których celem było określenie efektywności oczyszczania ścieków koksowniczych w układzie łączącym ciśnieniowe techniki membranowe, ultrafiltrację i odwróconą osmozę. W procesie niskociśnieniowej filtracji zastosowano wytwarzane w laboratorium płaskie membrany polisulfonowe różniące się zwartością struktury i porowatością.
The applied more and more often in wastewater treatment technology integrated membranes system are the most often preliminary system purification and final purification. The applied in investigations process of ultarfiltration had for removal from purified coke making wastewater high-molecular organic compounds during when process of reverse osmosis had to provided removing the rest of low-molecular organic compounds and mineral substances. It was showed that direct carrying away cleaned sewages into the natural environment was impossible from the attention to higher, compared with standardized, concentration of ammonia on the level 22.4 mg + NH+4 /dm 3. The applied purification wastewater should be cleaned by ammonia stripping. From prepared ultrafiltration polysulfone membranes the most profitable showed membrane with the polymer content of 16% in solution.
Źródło:
Proceedings of ECOpole; 2009, 3, 1; 185-190
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie membran z tworzyw syntetycznych do czyszczenia soku dyfuzyjnego
Autorzy:
Regiec, P
Powiązania:
https://bibliotekanauki.pl/articles/828197.pdf
Data publikacji:
2004
Wydawca:
Polskie Towarzystwo Technologów Żywności
Tematy:
ultrafiltracja
membrany ultrafiltracyjne
filtracja membranowa
polichlorek winylu
tworzywa sztuczne
oczyszczanie
sok dyfuzyjny
ultrafiltration
ultrafiltration membrane
membrane filtration
polyvinyl chloride
plastic
cleaning
diffusion juice
Opis:
Próby soku dyfuzyjnego o różnej jakości poddano ultrafiltracji w skali laboratoryjnej za pomocą membran z azotanu celulozy (CN) i polichlorku winylu (PCV). W sokach dyfuzyjnych i uzyskanych filtratach oznaczono zawartość: suchej substancji, sacharozy, cukrów redukujących oraz azotu a–aminokwasowego, a także lepkość. Obliczono czystość soków i efekt oczyszczania. Stwierdzono, że w wyniku ultrafiltracji soków, za pomocą membran z azotanu celulozy (CN) i polichlorku winylu (PCV) zawartość sacharozy i cukrów redukujących nie zmieniła się. Soki po ultrafiltracji charakteryzowały się mniejszą zawartością azotu a-aminokwasowego niż soki dyfuzyjne, przy czym filtracja przez membranę CN umożliwiła oddzielenie tych substancji w większym stopniu niż filtracja przez membranę PCV. Lepkość soków po filtracji była mniejsza w zakresie 0,7–1,8 mPa⋅s (membrana CN) i 0,5–1,7 mPa⋅s (membrana PCV) i była zbliżona do lepkości czystych roztworów sacharozy o podobnym stężeniu. Membrana PCV charakteryzowała się większym strumieniem permeatu, zwłaszcza w początkowej fazie filtracji, niż membrana CN. Im większa była czystość i mniejsza lepkość soku dyfuzyjnego, tym strumień permeatu był większy. Zastosowanie filtracji membranowej umożliwiło oczyszczenie soków o złej jakości, co w warunkach przemysłowych jest najczęściej niemożliwe. Soki otrzymane po filtracji przez membranę z azotanu celulozy charakteryzowały się lepszą jakością niż soki po filtracji przez membranę z polichlorku winylu.
Samples of diffusion juice showing varying quality were filtrated using an ultrafiltration process in a laboratory. The process was carried out using membranes made of cellulose nitrate (CN) and polyvinyl chloride (PVC). In the diffusion juices and filtrates obtained there were assayed the contents of dry mass, sucrose, reducing sugars, and α-aminoacid nitrogen, as well as viscosity. The juice purity level achieved and the final purification effect were calculated. It was stated that, owing to the filtration with cellulose nitrate (CN) and polyvinyl chloride (PVC) membranes, the content of sucrose and reducing sugars remained unchanged. After the ultra-filtration the juices had a smaller α-aminoacid content compared with the diffusion juices, and these substances were more accurately separated when filtrated through a CN membrane than through a PCV membrane. The viscosity of juices decreased by 0.7–1.8 mPa⋅s after the completed filtration with CN membranes, and by 0.5–1.7 mPa⋅s when filtrated using PVC membranes; this parameter was close to the viscosity of pure sucrose solutions of a similar concentration value. A PVC membrane was characterized by a greater flux of permeate than a CN membrane, especially in the initial phase of the filtration. The greater the purity and lower the viscosity of the diffusion juice, the greater the permeate flux. The application of membrane filtration made it possible to purify juices of bad quality, which are very hard to purify under industrial conditions. Juices filtered through a cellulose nitrate membrane were characterized by a better quality compared with the juices filtered through a polyvinyl chloride membrane.
Źródło:
Żywność Nauka Technologia Jakość; 2004, 11, 2; 121-133
1425-6959
Pojawia się w:
Żywność Nauka Technologia Jakość
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies