Tytuł:
The effect of temperature-dependent viscosity and thermal conductivity on velocity and temperature field: an analytical solution using the perturbation technique
Autorzy:
Panahi-Kalus, H.
Ahmadinejad, M.
Moosaie, A.
Powiązania:
https://bibliotekanauki.pl/articles/38610956.pdf
Data publikacji:
2020
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Tematy:
temperature-dependent material properties
laminar channel flow
anaytical solution
perturbation technique
Opis:
This paper proposes a general form of the perturbation expansion method for the governing equations of viscous flow coupled to the temperature evolution. The effect of the variations of viscosity and thermal conductivity with temperature on the temperature and velocity fields in a steady two-dimensional Couette–Poiseuille flow is examined. The presented analytical solution by the perturbation method is validated against a finite difference solution of the governing equations. The numerical and analytical solutions are in good agreement.
Źródło:
Archives of Mechanics; 2020, 72, 6; 555-576
0373-2029
Pojawia się w:
Archives of Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instability of viscous incompressible flow in a channel with transversely corrugated walls
Zjawisko destabilizacji przepływu laminarnego w kanale z poprzecznie pofalowanymi ścianami
Autorzy:
Szumbarski, J.
Powiązania:
https://bibliotekanauki.pl/articles/279211.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
wavy channel
laminar flow
linear stability
Opis:
Destabilization of the laminar flow in a channel with transversly wavy walls is investigated. The basic flow is determined by a semi-analytical method based on the concept of immersed boundaries. The stability equations are discretized by the spectrally accurate Chebyshev-tau method. It is demonstrated that the transversal wall waviness can be used in order to achieve destabilization of the laminar flow at low Reynolds numbers. Possible applications include the improvement of mixing and heat/mass transfer in various devices used in heat technology, biotechnology and medicine.
Praca poświęcona jest zjawisku destabilizacji przepływu laminarnego w kanale wywołanej poprzecznym pofalowaniem ścian. Przepływ niezaburzony wyznaczono przy pomocy semi-analitycznej metody zanurzonych granic. Wyprowadzono równania stateczności, które następnie poddano dyskretyzacji przy użyciu wielomianów Czebyszewa. Pokazano, że poprzeczne pofalowanie ścian o odpowiedniej geometrii prowadzi do destabilizacji przepływu przy niskich liczbach Reynoldsa i omówiono własności pola zaburzeń. Wydaje się, że opisany efekt może mieć znaczenie dla intensyfikacji mieszania i poprawy efektywności procesów transportu w technice cieplnej, biotechnologii i medycynie.
Źródło:
Journal of Theoretical and Applied Mechanics; 2007, 45, 3; 659-683
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of laminar flow passing through a T-splitter plate and bridge pier.
Autorzy:
Qasim, Rafi Mohammed
Jabbar, Tahseen Ali
Faisal, Safaa Hameed
Powiązania:
https://bibliotekanauki.pl/articles/36063658.pdf
Data publikacji:
2023
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
hydrodynamic
laminar flow
open channel
pier
splitter plate
Opis:
The present analysis focuses on the investigation of the two-dimensional flow passing a bridge pier nearby a splitter plate in different regimes of a laminar flow. The splitter plate is T-shaped and two different cases have been studied based on the form of the splitter plate relative to the bridge pier. The analysis is implemented for steady and incompressible water flow in an open channel. The current study deals with velocity vectors, drag coefficients, lift coefficients, and skin friction. The analysis of the velocity vector gave a good indicator about the separation process and dissipation, which occurs at the splitter plate before the occurrence of these processes at the front face of the pier, especially the flow separation process. Moreover, the velocity vector gave a good image about the flow direction at two regions, the first region is located between the rear portion of the splitter plate and the frontal face of the pier, while the second region is the wake region, which is located at the downstream of the pier. Negative drag coefficient, lift coefficient, and skin friction coefficient values are obtained from the analysis. This happens due to the existence of the splitter plate that leads to the reduction of these values.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2023, 32, 2; 135-154
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical solutions of heat transfer for laminar flow in rectangular channels
Autorzy:
Rybiński, W.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/240574.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analytical solution
heat transfer
rectangular channel
laminar flow
fully developed
rozwiązanie analityczne
wymiana ciepła
kanał prostokątny
przepływ laminarny
Opis:
The paper presents two analytical solutions namely for Fanning friction factor and for Nusselt number of fully developed laminar fluid flow in straight mini channels with rectangular cross-section. This type of channels is common in mini- and microchannel heat exchangers. Analytical formulae, both for velocity and temperature profiles, were obtained in the explicit form of two terms. The first term is an asymptotic solution of laminar flow between parallel plates. The second one is a rapidly convergent series. This series becomes zero as the cross-section aspect ratio goes to infinity. This clear mathematical form is also inherited by the formulae for friction factor and Nusselt number. As the boundary conditions for velocity and temperature profiles no-slip and peripherally constant temperature with axially constant heat flux were assumed (H1 type). The velocity profile is assumed to be independent of the temperature profile. The assumption of constant temperature at the channel’s perimeter is related to the asymptotic case of channel’s wall thermal resistance: infinite in the axial direction and zero in the peripheral one. It represents typical conditions in a minichannel heat exchanger made of metal.
Źródło:
Archives of Thermodynamics; 2014, 35, 4; 29-42
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies