Tytuł:
Improving sensitivity of residual current transformers to high frequency earth fault currents
Autorzy:
Czapp, S.
Dobrzyński, K.
Klucznik, J.
Lubosny, Z.
Kowalak, R.
Powiązania:
https://bibliotekanauki.pl/articles/141169.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformers
earth fault currents
electric devices
electromagnetic couplings
high frequency
Opis:
For protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed the modification in the structure of residual current devices. This modification improves sensitivity of residual current devices when high frequency earth fault current occurs. The test of the modified residual current device proved that the authors’ proposition is appropriate.
Źródło:
Archives of Electrical Engineering; 2017, 66, 3; 485-494
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electric shock hazard in circuits with variable-speed drives
Autorzy:
Czapp, S.
Guzinski, J.
Powiązania:
https://bibliotekanauki.pl/articles/199800.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
variable speed drives
earth fault currents
power electronics converters
protection against electric shock
residual current devices
napędy o zmiennej prędkości
prądy ziemnozwarciowe
zabezpieczenia przed porażeniem elektrycznym
przekształtnik energoelektryczny
Opis:
The conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50‒60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives without inverter output (motor) filter and with one of the two types of inverter output filters being used. The details of both filters are presented, and the effect of harmonics of earth fault current on ventricular fibrillation is evaluated. Furthermore, the effect of harmonics, which occurs in circuit of variable-speed drive, on the tripping current of residual current devices is presented. Residual current devices may be utilized to ensure protection against direct and indirect contact, but limitations in their proper operation, due to harmonics, may exist. Operational characteristics of a proposed residual current device dedicated to circuits with earth fault current containing harmonics, as in the variable-speed circuits, are presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 3; 361-372
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa metoda obliczania rozpływu prądów zwarciowych w przewodach odgromowych linii wysokiego napięcia
A new method of earth wires current calculation in HV transmission lines
Autorzy:
Klucznik, J.
Powiązania:
https://bibliotekanauki.pl/articles/267645.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
linie elektroenergetyczne
przewody odgromowe
zwarcia
fault currents
earth faults
earth wires
overhead transmission lines
Opis:
Referat przedstawia nowatorską metodę obliczania wartości prądów płynących w przewodach odgromowych w czasie zwarć, pozwalającą na dobór przewodów odgromowych pod względem wytrzymałości cieplnej. Proponowana metoda charakteryzuje się większą dokładnością i większą uniwersalnością niż powszechnie stosowane metody, pozwalając tym samym na dobór przewodów odgromowych z mniejszym ryzykiem niepewności. Prezentowana metoda obliczeniowa pozwala również na ocenę ochrony przeciwporażeniowej linii, poprzez wyznaczenie wartości prądów płynących w uziomach słupów.
The paper presents a new method to compute a phase-to-earth fault current distribution in overhead transmission line. The method is based on the tableau analysis of an unbalanced, multi-wire model of a transmission line. The proposed method allows the values of the currents in earth wires to be determined for each span of the line, as well as the current and voltage for every tower of the line. The advantage of this method over others is the possibility of carrying out calculations for any system configuration, regardless of its complexity. The method can be used for analysis of any type of transmission line (single circuit, double circuit and multi-circuit lines) with any number of earth wires. The calculation results may be used for complex designs of transmission line earthing systems, earth wire thermal rating selection, and the evaluation of shock hazards.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 56; 39-45
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of network voltages to insulation monitoring in unearthed AC circuits with rectifiers
Wykorzystanie napięć sieci do kontroli izolacji obwodów AC IT z prostownikami
Autorzy:
Olszowiec, P.
Powiązania:
https://bibliotekanauki.pl/articles/155121.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
unearthed AC networks
rectifiers
earth fault voltages and currents
phase voltage mean value
phase voltages zero sequence component
sieci izolowane AC
prostowniki
napięcia i prądy doziemne
wartość średnia napięcia fazowego
składowa zerowa napięć fazowych
Opis:
Maximum values of possible earth fault currents in low voltage unearthed AC networks supplying DC circuits through diode rectifiers are critical for evaluation of possible electric shock and fire hazards caused by insulation condition deterioration. A method for analytical determination of time functions of earth fault parameters, i.e. wire-to-earth voltages and currents is presented in the paper. Application of two characteristic parameters i.e. the phase voltage mean value and the phase voltages zero sequence component to insulation condition evaluation is discussed. A new method exploiting the phase voltages mean value for insulation resistance monitoring is presented.
Maksymalne wartości prądów zwarć z ziemią w sieciach izolowanych AC zasilających obwody DC przez prostowniki diodowe decydują o ewentualnych ryzykach porażenia osób, pożaru i wybuchu. W artykule przedstawiono metodę analitycznego wyznaczania przebiegów czasowych parametrów ziemnozwarciowych tj. napięć i prądów doziemnych; zagadnienie to było dotychczas pomijane w dostępnej literaturze. Wyznaczono zależności dla charakterystycznego parametru układów AC/DC IT, którym jest wartość średnia napięć fazowych strony AC. Omówiono przydatność tej wielkości dla kontroli izolacji tych sieci oraz lokalizacji doziemień. W oparciu o najczęstsze w praktyce przypadki pokazano, że składowa zerowa napięć fazowych spełnia funkcję sygnalizacji pogorszenia stanu izolacji praktycznie jedynie dla strony AC (rys. 4). Przy uszkodzeniach izolacji po stronie DC napięcie tej składowej w nieznacznym stopniu zależy od rezystancji zwarcia doziemnego. Z użyciem wartości zastępczej rezystancji izolacji całego układu AC/DC IT oszacowano maksymalny poziom prądu upływu decydujący o bezpieczeństwie porażeniowym i pożarowym sieci. W artykule zaproponowano nową metodę wyznaczania wartości zastępczej rezystancji izolacji całego układu. Procedura z użyciem dodatkowego rezystora testowego obejmuje pomiary wartości średniej napięć fazowych, na bazie których oblicza się wartość szukanego parametru. Oprócz prostoty i braku wrażliwości na pojemności doziemne metoda wyróżnia się uniwersalnością, gdyż uwzględnia upływności izolacji całej sieci AC/DC IT.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 12, 12; 1252-1255
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies