Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "delivery flow" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Delivery-flow routing and scheduling subject to constraints imposed by vehicle flows in fractal-like networks
Autorzy:
Bocewicz, G.
Banaszak, Z.
Nielsen, I.
Powiązania:
https://bibliotekanauki.pl/articles/229533.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
transport network
fractal structure
declarative modeling
multimodal processes
delivery flow
vehicles flow
Opis:
The problems of designing supply networks and traffic flow routing and scheduling are the subject of intensive research. The problems encompass the management of the supply of a variety of goods using multi-modal transportation. This research also takes into account the various constraints related to route topology, the parameters of the available fleet of vehicles, order values, delivery due dates, etc. Assuming that the structure of a supply network, constrained by a transport network topology that determines its behavior, we develop a declarative model which would enable the analysis of the relationships between the structure of a supply network and its potential behavior resulting in a set of desired delivery-flows. The problem in question can be reduced to determining sufficient conditions that ensure smooth flow in a transport network with a fractal structure. The proposed approach, which assumes a recursive, fractal network structure, enables the assessment of alternative delivery routes and associated schedules in polynomial time. An illustrative example showing the quantitative and qualitative relationships between the morphological characteristics of the investigated supply networks and the functional parameters of the assumed delivery-flows is provided.
Źródło:
Archives of Control Sciences; 2017, 27, 2; 135-150
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel approaches in the post-tracheostomy care of the COVID-19 patient
Nowatorskie podejścia w opiece nad chorym na COVID-19 po zabiegu tracheostomii
Autorzy:
Rai, Ashish
Chang, Anna P
Soo, Steven
Thomas, Joy
Ackerman, Judy
Mitzman, Brian
Bender, Michael T
Powiązania:
https://bibliotekanauki.pl/articles/1033287.pdf
Data publikacji:
2020
Wydawca:
Towarzystwo Pomocy Doraźnej
Tematy:
Covid-19
decannulation.
high flow oxygen delivery
tracheostomy
Opis:
INTRODUCTION: SARS-CoV-2 is a novel strain of coronavirus that has caused illness in over 6 million people worldwide as of June 2020. Patients with severe illness are treated with invasive mechanical ventilation, as such, tracheostomy has become a topic of interest. Traditional schema employed during independent breathing trials in patients with tracheostomies employ the use of a collar mask attached to flexible corrugated tubing with humidified oxygen from a wall source. One drawback of this arrangement is the creation of an open circuit with the potential for viral aerosolization. MATERIAL AND METHODS: We adapted high flow oxygen (HFO) therapy to patient’s tracheostomy tube and devised a rapid decannulation protocol for patients recovering from Covid-19. Corrugated flexible tubing with a heating element is attached to the HFO meter-blender/heated humidifier apparatus and then connected directly to one end of a Y-adapter. An in-line suction kit specified for tracheostomy patients is also placed. Humidified air is delivered to the patient using the heating element of the HFO system obviating the need for a heat moisture exchanger. A second corrugated tube is attached to the free end of the Y-adapter and a non-conductive viral particle filter is attached to its free end to limit viral aerosolization. RESULTS: The mean time to tracheostomy placement is 18 days from initiation of mechanical ventilation (5-39 days). To date 20/52 (38%) patients have undergone tracheostomy tube removal, and of those 13 have been discharged. The mean time to decannulation is 15 days (8-32 days). Three patients failed decannulation requiring repeat endotracheal intubation (5.7%). SARS-CoV-2 was not detected in 22/24 patients undergoing repeat polymerase chain reaction testing on day 45 after initial positive test. CONCLUSIONS: Utilizing HFO to tracheostomy scheme creates a closed circuit theoretically reducing the risk of COVID-19 exposure, while also helping patients breathe independently. This schema coupled with a rapid decannulation protocol is a reasonable alternative in select patients recovering from severe COVID-19.
WSTĘP: SARS-CoV-2 to nowy szczep koronawirusa, który wywołał zakażenia u ponad 6 milionów ludzi na całym świecie od czerwca 2020 r. Pacjenci z ciężkimi chorobami są leczeni za pomocą inwazyjnej wentylacji mechanicznej, której przedmiotem zainteresowania stała się tracheostomia. W tradycyjnym schemacie stosowanym podczas niezależnych prób oddechowych u pacjentów z tracheostomią należy stosować maskę z kołnierzem przymocowaną do elastycznej rurki falistej z nawilżeniem tlenu ze źródła ściennego. Wadą tego układu jest utworzenie obwodu otwartego z potencjałem na aerozol wirusowy. MATERIAŁ I METODY: Dostosowano terapię tlenem o wysokim przepływie (HFO) do rurki tracheostomijnej pacjenta i opracowano protokół szybkiej dekaniulacji dla pacjentów wracających do zdrowia po Covid-19. Rura elastyczna karbowana z elementem grzejnym jest przymocowana do miernika-mieszalnika / podgrzewanego nawilżacza HFO, a następnie podłączona bezpośrednio do jednego końca adaptera Y. Umieszczany jest również zestaw do odsysania liniowego przeznaczony dla pacjentów z tracheostomią. Nawilżone powietrze jest dostarczane do pacjenta korzystając z elementu grzejnego systemu HFO, co eliminuje potrzebę stosowania wymiennika ciepła i wilgoci. Rura karbowana jest przymocowana do wolnego końca trójnika, a nieprzewodzący filtr cząstek wirusowych jest przymocowany do jego wolnego końca, aby ograniczyć aerozolację wirusów. WYNIKI: Średni czas do założenia tracheostomii to 18 dni od rozpoczęcia wentylacji mechanicznej (5-39 dni). Do tej pory usunięto rurkę tracheostomijną u 20/52 (38%) pacjentów, z czego 13 zostało wypisanych do domu. Średni czas do dekaniulacji to 15 dni (8-32 dni). U trzech pacjentów dekaniulacja nie powiodła się, wymagając powtórzenia intubacji dotchawiczej (5,7%). SARS-CoV-2 nie został wykryty u 22/24 pacjentów poddawanych powtórnemu łańcuchowi polimerazy badania reakcji w 45 dniu po wstępnym pozytywnym teście. WNIOSKI: Wykorzystanie HFO do schematu tracheostomii tworzy zamknięty obwód teoretycznie zmniejszając ryzyko ekspozycji na COVID-19, a jednocześnie pomaga pacjentom w samodzielnym oddychaniu. Ten schemat w połączeniu z szybkim protokołem dekaniulacji jest rozsądną alternatywą u wybranych pacjentów po powrocie z ciężkiego COVID-19.
Źródło:
Critical Care Innovations; 2020, 3, 3; 13-19
2545-2533
Pojawia się w:
Critical Care Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wear processes of hydraulic plunger and barrel assemblies connected with the time of their work
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/246273.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
pump delivery
volume flow rate
hydraulic precision pair
avionic technology
Opis:
The article discusses the wear processes of hydraulic plunger assemblies connected with the time of their work and the impact exerted by these processes on the value of parameters of a hydraulic plunger pump. It describes working conditions and loading of a hydraulic plunger assembly. The paper presents also the results of empirical analyses of the wear process of the connection of the plunger base with the working surface of the swivel disk, which is related to time and conditions of its work. It discusses the impact of the loading value and sliding speed on the character and intensity of the wear of the connection between the plunger base and the working surface of a swivel disk. Furthermore, it presents a general characteristic and mechanism responsible for the wear of the hydraulic plunger assembly through oxidation. The article also analyses the impact of the hardness of materials used for producing the hydraulic plunger assembly on the intensity of its wear. Another issue is the dependence of the coefficient of friction in the hydraulic plunger assembly on the contact pressure at different sliding speeds. Finally, the paper discusses the impact of wearing of the cooperating plunger base and the working surface of the swivel disk on the initial parameters of the hydraulic pump at a given working pressure and its volumetric efficiency.
Źródło:
Journal of KONES; 2014, 21, 4; 515-524
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of dynamic properties attributable to hydraulic lines onto operation of avionic
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/247057.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
pump delivery
volume flow rate
hydrostatic (forcing) pressure
compressibility effect
viscous friction effect
Opis:
The present paper is dedicated to discuss how dynamic parameters of a hydraulic line intended to transfer hydraulic power from a source of hydraulic power (a hydraulic pump) to an actuating device (a hydraulic motor) can affect operation of an avionic hydraulic drive. Avionic hydraulic drives are operated with fast-varying waveforms of flow intensities and pressures. It is why analysis of most hydraulic drive systems must take account of compressibility of working fluid and elasticity of hydraulic lines. It leads to a wave model for propagation of energy variation down a hydraulic line (a pipe). The paper deals with flow of a compressible liquid via a hydraulic line with flexible walls. Theoretical deliberations were successfully verified by experimental research studies that were carried out on a dedicated test bench, therefore the presented amplitude vs. frequency characteristic curves of the hydraulic line could be obtained from both theoretical considerations and experimental research studied. The experimental research studies were carried out for hydraulic line terminated with a fixed flow restrictor alone and a flow restrictor combined with a hydraulic accumulator as well as for a hydraulic line supplied from a source of constant pressure and terminated with a valve with adjustable flow together with a hydraulic accumulator. The theoretical calculations for the amplitude vs. frequency characteristic curve are based on a model for a hydraulic line with its resistance depending on frequency.
Źródło:
Journal of KONES; 2011, 18, 4; 535-542
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of dynamic properties of hydraulic lines for fluid power transmission
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/247615.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
delivery of a pump
volume flow rate
hydrostatic (forcing) pressure
compressibility effect
viscous friction effect
Opis:
This paper presents the results of a hydraulic line dynamic properties analysis taking into account inertia of the fluid flowing in rigid and flexible lines, the compressibility effect for this fluid and the viscous friction effect. The following are described and analyzed: solution of the wave equation in the form binding four variables: pressure and flow rate at the line input, and pressure and flow rate and the line output; two of the above-mentioned variables should be regarded as independent (input) and the other two as dependent (output), the accuracy comparison of distributed parameters model to lumped parameters model with regard to applicability range in hydraulic systems analysis, pressure value at given installation points as a response to rapid valve closing (transient response) or to valve opening (waterhammer effect). In these considerations the hydraulic line is regarded as a two-port with two inputs and two outputs with a definite transmittance matrix. Main considerations concern the variable resistance model. A general solution is given as a function of the Laplace operator. Introducing appropriate simplifications into the variable resistance model, the constant resistance model and lossless line model is obtained. Also, general solutions for three different lump parameter models are presented. For the lumped parameters lin presents three equivalent models possible, i.e. as: a symmetrical two-port, a two-port with shared resistance and a two-port with capacitance at the output.
Źródło:
Journal of KONES; 2010, 17, 3; 467-475
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania modelowe strumienia objętości piasku i wody w podnośniku powietrznym
Model studies of sand and water flow rate in an air lift pump
Autorzy:
Kalenik, M.
Powiązania:
https://bibliotekanauki.pl/articles/236558.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
air-lift pump
air injector
three-phase flow
sand flow rate
water flow rate
delivery head
empirical formula
podnośnik powietrzny
mieszacz
przepływ trójfazowy
strumień objętości piasku
strumień objętości wody
wysokość podnoszenia
wzory empiryczne
Opis:
Analysis of results from a study on sand (Qz) and water (Qw) flow rate in an air lift pump was presented as well as the methodology of empirical formulas derivation to calculate those parameters. A comparative analysis of the values of sand and water flow rate from direct measurements and the calculated values was carried out. The scope of laboratory research encompassed derivation of the aforementioned empirical formulas to calculate water and sand flow rate for the plastic air lift pump with internal diameter of the delivery pipe d = 0.04 m, at fixed sand-water mix delivery heads of 0.40 m, 0.80 m and 1.20 m. Dimensional analysis and multiple regression were applied to derive the formulas. It was established that the water and sand flow rate decreased along with the increase of the delivery head, and the values of water flow rate were smaller than those of the sand flow rate. It was demonstrated that the air pressure in such devices cannot be lower than 110 kPa or exceed 175 kPa as at higher pressure values the sand and water flow rate started to fall. The values of sand and water flow rates calculated by the derived formulas coincided very well with the values determined by direct measurements using the 1:1 scale laboratory model.
Przedstawiono analizę wyników badań strumienia objętości piasku (Qz) i wody (Qw) w podnośniku powietrznym oraz omówiono metody wyznaczania wzorów empirycznych do obliczania wartości tych parametrów. Przeprowadzono analizę porównawczą wartości strumienia objętości piasku i wody wyznaczonych w bezpośrednich pomiarach z wartościami obliczonymi za pomocą wzorów empirycznych. Zakres badań laboratoryjnych obejmował wyprowadzenie wzorów do obliczania wartości strumienia objętości piasku i wody w powietrznym podnośniku z tworzywa sztucznego o średnicy wewnętrznej rurociągu tłocznego d=0,04 m, przy zadanych wysokościach podnoszenia mieszaniny piasku i wody równych 0,40 m, 0,80 m i 1,20 m. Do wyznaczenia wzorów empirycznych do obliczania wartości strumienia objętości piasku i wody zastosowano analizę wymiarową i metodę regresji wielokrotnej. W przypadku badanej konstrukcji podnośnika powietrznego stwierdzono, że wraz ze wzrostem wysokości podnoszenia mieszaniny piasku i wody strumień objętości piasku i wody malał, a wartości strumienia objętości wody były mniejsze od wartości strumienia objętości piasku. Wykazano, że w urządzeniu tego typu ciśnienie powietrza nie może być mniejsze niż 110 kPa i nie powinno przekraczać 175 kPa, ponieważ przy wyższych wartościach ciśnienia powietrza strumień objętości piasku i wody zaczynał maleć. Wartości strumienia objętości piasku i wody obliczone za pomocą wyprowadzonych wzorów bardzo dobrze pokrywały się (korelowały?) z wartościami wyznaczonymi w pomiarach bezpośrednich na modelu laboratoryjnym w skali 1:1.
Źródło:
Ochrona Środowiska; 2017, 39, 1; 45-52
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies