Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cement augmentation" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Investigation of pullout strength in different designs of pedicle screws for osteoporotic bone quality using finite element analysis
Autorzy:
Yang, Shih-Chieh
Liu, Pao-Hsin
Tu, Yuan-Kun
Powiązania:
https://bibliotekanauki.pl/articles/306201.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
osteoporoza
cement
FEM
osteoporosis
cement augmentation
pedicle screw
pullout strength
finite element analysis
Opis:
The purpose of this study was to investigate pullout strength of three types of pedicle screws with and without cement augmentation in osteoporotic bone using finite element analysis. Methods: Twelve 3D finite element models were created to investigate the effect of pullout strength when comparing between pedicle screw types and bone cement clouds. The bottom side of bone block model was constrained and U-shape head was applied 1 mm in direction of longitudinal axis of pedicle screw to perform pullout resistance. The material properties of the FEA was set as linear elastic, homogenous, isotropic condition. The element sensitivity of convergence testing has been performed and variation of the sequential analytical results was less than 3%. Results: The results showed that the maximum total reaction force (133.8 N) was detected in the model of cannulated pedicle screw combined with a central pin with 4 ml cement augmentation, but, in contrast, the minimum total reaction force (106.8 N) was discovered in the model of cannulated pedicle screw without cement. A strong relationship (r = 0.9626) is found in comparison with the biomechanical results between pullout strength of sawbone testing and reaction forces of the FEA. Conclusions: The study concludes that the cannulated pedicle screw can not only provide an inner guider for cement flow and increase bending resistance (deflection effect) when a central pin is selected, but also can improve the pullout strength in the osteoporotic bone to add cement augmentation. The design of the cannulated pedicle screw is suggested for poor bone quality to change pullout failure.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 3; 57-66
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pullout evaluation of sawbone experiment in different types of pedicle screws combined with bone cement augmentation for severe osteoporotic spine
Autorzy:
Yang, S.-C.
Liu, P.-H.
Tu, Y.-K.
Powiązania:
https://bibliotekanauki.pl/articles/307271.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
osteoporoza
kości
wytrzymałość
osteoporosis
bone cement augmentation
cannulated pedicle screw
sawbone
pullout strength
Opis:
Purpose: The conventional screw is unable to provide enough screw-bone interface strength for osteoporotic cencellous bone, and complications resulting from loosening or failure of the implants remain a significant clinical problem. Hence, the purpose of this study is to investigate pullout strength and energy in three types of the pedicle screws, including conventional solid pedicle screw, cannulated pedicle screw, and cannulated pedicle screw with a central pin, using osteoporotic sawbone test block with different bone cement volumes through pullout force testing. Methods: The control group (n = 15) of the osteoporotic sawbone test block includes groups A, B, and C to reflect three types of the pedicle screws without bone cement augmentation. The cemented group (n = 45) of the osteoporotic sawbone test block includes groups D1, D2, D3, E1, E2, E3, F1, F2, and F3 to reflect three types of the pedicle screws with PMMA bone cement of 2, 3, and 4 mL augmentation. Results: The results showed that the pullout strength and energy in the cemented group were significantly larger than that in the control group. Moreover, the best performances of the pullout strength and energy in the cemented group were evidenced obviously in the case of cannulated pedicle screw with a central pin with 4 mL bone cement augmentation. Conclusions: This study concludes that cement argumentation in the cannulated pedicle screw with a central pin can increase a pullout strength of pedicle screw for severe osteoporotic patients while bone cement of injective volume is limited.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 55-64
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies