Tytuł:
Laser interference patterning of diamond-like carbon layers for directed migration and growth of smooth muscle cell depositions
Autorzy:
Marczak, J.
Kusinski, J.
Major, R.
Rycyk, A.
Sarzynski, A
Strzelec, M.
Czyz, K
Powiązania:
https://bibliotekanauki.pl/articles/174984.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
laser interference lithography
Nd
YAG laser
diamond-like carbon (DLC) structuring
biocompatible scaffolds
Opis:
Seeding of cells on functional, biocompatible scaffolds is a crucial step in achieving the desired engineered tissue. The authors show the constructional solutions of the Nd:YAG pulse laser system with the Q-switch modulation for direct and interferential shaping of the surface of biocompatible materials. The two-channel interference system is distinguished by high control, simplicity and repetitiveness regarding laser energy level and dimensions of the surface structures. The experiments were conducted on hard, biocompatible substrates of amorphous carbon (diamond-like carbon, DLC) and were preliminarily tested on smooth muscle cell depositions.
Źródło:
Optica Applicata; 2014, 44, 4; 575-586
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fabrication of Pure Electrospun Materials from Hyaluronic Acid
Materiały z kwasu hialuronowego otrzymywane metodą elektroprzędzenia przeznaczone do zastosowań w inżynierii tkankowej
Autorzy:
Pabjańczyk-Wlazło, E.
Krucińska, I.
Chrzanowski, M.
Szparaga, G.
Chaberska, A.
Kolesińska, B.
Komisarczyk, A.
Boguń, M.
Powiązania:
https://bibliotekanauki.pl/articles/234250.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
biocompatible polymers
natural polymers
biomimetism
biomimetic scaffolds
regenerative medicine
electrospinning
hyaluronic acid
polimery biokompatybilne
polimery naturalne
biomimetyzm
szkielety biomimetyczne
medycyna regeneracyjna
elektrospining
kwas hialuronowy
Opis:
The aim of the research was to develop optimal conditions for manufacturing materials based on hyaluronic acid by the electrospun method. The studies were composed of three stages: the process of selection of the optimal solvent (mixture of solvents), the molecular weight of hyaluronic acid, and the concentration of biopolymer in the spinning solution. The influence of variable parameters on the rheological properties of the spinning solutions and electrospinning trails was tested. Depending on the electrospinning regime applied, the fibers obtained were characterised by a diameter of the order of 20 to 400 nm. As a result of the development works presented, an optimal molecular weight of the polymer, its concentration and system of solvents were determined, together with process parameters, ensuring a stable electrospinning process and relatively homogeneous nanofibers. Additionally studies on the residues of solvents used during electrosun formation were done and parameters of drying of the final materials were examined. This approach (verification of the presence of organic solvent residue in the nanofibrous formed) is important for the suitability of nanofibres as scaffolds for regenerative medicine. This study provides an opportunity for the understanding and identification of process parameters, allowing for predictable manufacturing nanofibers based on natural biopolymers, which makes it tremendously beneficial in terms of customisation.
Celem badań było opracowanie optymalnych warunków otrzymywania nanowłókien z kwasu hialuronowego. Badania obejmowały następujące etapy realizacji pracy: proces doboru optymalnego rozpuszczalnika dla polimeru oraz dobór masy cząsteczkowej kwasu hialuronowego. Zbadano właściwości reologiczne roztworów oraz wpływ zmiennych parametrów procesowych na strukturę mikroskopową włókien. W zależności od zastosowanych parametrów elektroprzędzenia otrzymane włókna charakteryzowały się średnią rzędu od 20 do 400 nm. Dodatkowo przeprowadzono badania dotyczące pozostałości rozpuszczalników stosowanych w przygotowaniu roztworów przędzalniczych, co jest istotne z punktu widzenia wykorzystania tych materiałów w obrębie medycyny regeneracyjnej.
Źródło:
Fibres & Textiles in Eastern Europe; 2017, 3 (123); 45-52
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies